Thermal performance is the most important factor in the development of a borehole heat exchanger utilizing geothermal energy.The thermal performance is affected by many different design parameters and different operat...Thermal performance is the most important factor in the development of a borehole heat exchanger utilizing geothermal energy.The thermal performance is affected by many different design parameters and different operating conditions such as bleeding.This eventually determines the operation and cost efficiency of the borehole heat exchanger system.The thermal performance of an open standing column well (SCW) type geothermal heat exchanger was assessed under the influence of bleeding.For this,a thermal response test rig was established with line-source theory.The test rig also had a bleeding function by releasing fluid while taking additional underground water through the heat exchanger.The thermal response test was performed with an additional constant input heat source.Effective thermal conductivity and thermal resistance were obtained from the measured data.From the measurement,the effective thermal conductivity is found to have 1.47 times higher value when bleeding is applied.The thermal resistance also increases by 1.58 times compared to a non-bleeding case.This trend indicates enhanced heat transfer in the SCW type heat exchanger with a bleeding function.Bleeding,therefore,could be an effective method of achieving a high heat transfer rate in the SCW type heat exchanger with sufficient underground water supply.展开更多
Reticulocytosls in rats was induced by repetitive bleeding. Both the in vitro and the in vivo studies showed that the detected reductive speed of methemoglobin of the bleeding group was faster than that of the control...Reticulocytosls in rats was induced by repetitive bleeding. Both the in vitro and the in vivo studies showed that the detected reductive speed of methemoglobin of the bleeding group was faster than that of the control group at all time intervals. At the same time, the NADH-cytochrome b5 methemoglobin reductase activity and the molybdenum content in erythrocytes of the bleeding group were significantly increased. Regressional analysis showed that there was a significantly positive correlation between the enzyme activity and the molybdenum content. It is proposed that molybdenum might be required for the enzyme activity展开更多
基金Project supported by the Second Stage of Brain Korea 21 Projects and Changwon National University in2011-2012
文摘Thermal performance is the most important factor in the development of a borehole heat exchanger utilizing geothermal energy.The thermal performance is affected by many different design parameters and different operating conditions such as bleeding.This eventually determines the operation and cost efficiency of the borehole heat exchanger system.The thermal performance of an open standing column well (SCW) type geothermal heat exchanger was assessed under the influence of bleeding.For this,a thermal response test rig was established with line-source theory.The test rig also had a bleeding function by releasing fluid while taking additional underground water through the heat exchanger.The thermal response test was performed with an additional constant input heat source.Effective thermal conductivity and thermal resistance were obtained from the measured data.From the measurement,the effective thermal conductivity is found to have 1.47 times higher value when bleeding is applied.The thermal resistance also increases by 1.58 times compared to a non-bleeding case.This trend indicates enhanced heat transfer in the SCW type heat exchanger with a bleeding function.Bleeding,therefore,could be an effective method of achieving a high heat transfer rate in the SCW type heat exchanger with sufficient underground water supply.
文摘Reticulocytosls in rats was induced by repetitive bleeding. Both the in vitro and the in vivo studies showed that the detected reductive speed of methemoglobin of the bleeding group was faster than that of the control group at all time intervals. At the same time, the NADH-cytochrome b5 methemoglobin reductase activity and the molybdenum content in erythrocytes of the bleeding group were significantly increased. Regressional analysis showed that there was a significantly positive correlation between the enzyme activity and the molybdenum content. It is proposed that molybdenum might be required for the enzyme activity