This study investigated the effect of velocity encoding on measurement of brain blood flow and blood volume of inflow and outflow using phase-contrast magnetic resonance angiography. A single two-dimensional phase-con...This study investigated the effect of velocity encoding on measurement of brain blood flow and blood volume of inflow and outflow using phase-contrast magnetic resonance angiography. A single two-dimensional phase-contrast magnetic resonance angiography slice was applied perpendicular to the internal carotid artery and the vertebral artery at C2 level. For each subject, the velocity encoding was set from 30 to 90 cm/s with an interval of 10 cm/s for a total of seven settings. Various velocity encodings greatly affected blood flow volume, maximal blood flow velocity and mean blood flow velocity in the internal carotid artery, but did not significantly affect vertebral arteries and jugular veins. When velocity encoding was 60-80 cm/s, the inflow blood volume was 655 _+ 118 mL/min, and the outflow volume was 506 _+ 186 mL/min. The ratio of outflow/inflow was steady at 0.78-0.83, and there was no aliasing in any of the images. These findings suggest that velocity encodings of 60 80 cm/s should be selected during measurement of cerebral blood flow volume using phase-contrast magnetic resonance angiography.展开更多
The optimal velocity encoding of phase-contrast magnetic resonance angiography (PC MRA) in measuring cerebral blood flow volume (BFV) ranges from 60 to 80 cm/s. To verify the accuracy of two-dimensional (2D) PC ...The optimal velocity encoding of phase-contrast magnetic resonance angiography (PC MRA) in measuring cerebral blood flow volume (BFV) ranges from 60 to 80 cm/s. To verify the accuracy of two-dimensional (2D) PC MRA, the present study localized the region of interest at blood vessels of the neck using PC MRA based on three-dimensional time-of-flight sequences, and the velocity encoding was set to 80 cm/s. Results of the measurements showed that the error rate was 7.0±6.0% in the estimation of BFV in the internal carotid artery, the external carotid artery and the ipsilateral common carotid artery. There was no significant difference, and a significant correlation in BFV between internal carotid artery + external carotid artery and ipsilateral common carotid artery. In addition, the BFV of the common carotid artery was correlated with that of the ipsilateral internal carotid artery. The main error was attributed to the external carotid artery and its branches. Therefore, after selecting the appropriate scanning parameters and protocols, 2D PC MRA is more accurate in the determination of BFV in the carotid arteries.展开更多
Background: The hepatic hemodynamics is an essential parameter in surgical planning as well as in various disease processes. The transit time ultrasound(TTUS) perivascular flow probe technology is widely used in clini...Background: The hepatic hemodynamics is an essential parameter in surgical planning as well as in various disease processes. The transit time ultrasound(TTUS) perivascular flow probe technology is widely used in clinical practice to evaluate the hepatic inflow, yet invasive. The phase-contrast-MRI(PC-MRI) is not invasive and potentially applicable in assessing the hepatic blood flow. In the present study, we compared the hepatic inflow rates using the PC-MRI and the TTUS probe, and evaluated their predictive value of post-hepatectomy adverse events. Methods: Eighteen large white pigs were anaesthetized for PC-MRI and approximately 75% hepatic resection was performed under a unified protocol. The blood flow was measured in the hepatic artery(Qha), the portal vein(Qpv), and the aorta above the celiac trunk(Qca) using PC-MRI, and was compared to the TTUS probe. The Bland-Altman method was conducted and a partial least squares regression(PLS) model was implemented. Results: The mean Qpv measured in PC-MRI was 0.55 ± 0.12 L/min, and in the TTUS probe was 0.74 ± 0.17 L/min. Qca was 1.40 ± 0.47 L/min in the PC-MRI and 2.00 ± 0.60 L/min in the TTUS probe. Qha was 0.17 ± 0.10 L/min in the PC-MRI, and 0.13 ± 0.06 L/min in the TTUS probe. The Bland-Altman method revealed that the estimated bias of Qca in the PC-MRI was 32%(95% CI:-49% to 15%); Qha 17%(95% CI:-15% to 51%); and Qpv 40%(95% CI:-62% to 18%). The TTUS probe had a higher weight in predicting adverse outcomes after 75% resection compared to the PC-MRI( β= 0.35 and 0.43 vs β = 0.22 and 0.07, for tissue changes and premature death, respectively). Conclusions: There is a tendency of the PC-MRI to underestimate the flow measured by the TTUS probes. The TTUS probe measures are more predictive of relevant post-hepatectomy outcomes.展开更多
基金the Medical Program of the Scientific & Technical Foundation in Xiamen(MRI study of chronic cerebrovascular insufficiency) in 2008,No.3502Z20084028
文摘This study investigated the effect of velocity encoding on measurement of brain blood flow and blood volume of inflow and outflow using phase-contrast magnetic resonance angiography. A single two-dimensional phase-contrast magnetic resonance angiography slice was applied perpendicular to the internal carotid artery and the vertebral artery at C2 level. For each subject, the velocity encoding was set from 30 to 90 cm/s with an interval of 10 cm/s for a total of seven settings. Various velocity encodings greatly affected blood flow volume, maximal blood flow velocity and mean blood flow velocity in the internal carotid artery, but did not significantly affect vertebral arteries and jugular veins. When velocity encoding was 60-80 cm/s, the inflow blood volume was 655 _+ 118 mL/min, and the outflow volume was 506 _+ 186 mL/min. The ratio of outflow/inflow was steady at 0.78-0.83, and there was no aliasing in any of the images. These findings suggest that velocity encodings of 60 80 cm/s should be selected during measurement of cerebral blood flow volume using phase-contrast magnetic resonance angiography.
基金the Medical Program of Scientific & Technical Foundation in Xiamen in 2008, No. 3502Z20084028
文摘The optimal velocity encoding of phase-contrast magnetic resonance angiography (PC MRA) in measuring cerebral blood flow volume (BFV) ranges from 60 to 80 cm/s. To verify the accuracy of two-dimensional (2D) PC MRA, the present study localized the region of interest at blood vessels of the neck using PC MRA based on three-dimensional time-of-flight sequences, and the velocity encoding was set to 80 cm/s. Results of the measurements showed that the error rate was 7.0±6.0% in the estimation of BFV in the internal carotid artery, the external carotid artery and the ipsilateral common carotid artery. There was no significant difference, and a significant correlation in BFV between internal carotid artery + external carotid artery and ipsilateral common carotid artery. In addition, the BFV of the common carotid artery was correlated with that of the ipsilateral internal carotid artery. The main error was attributed to the external carotid artery and its branches. Therefore, after selecting the appropriate scanning parameters and protocols, 2D PC MRA is more accurate in the determination of BFV in the carotid arteries.
基金supported mainly by the “Agence de la Biomedecine” through its program of Research(AOR 2009)BM,AC,BP,WM,VCI and VE acknowledged funding of project ANR-13-TECS-0006 by the Agence Nationale de la Recherche
文摘Background: The hepatic hemodynamics is an essential parameter in surgical planning as well as in various disease processes. The transit time ultrasound(TTUS) perivascular flow probe technology is widely used in clinical practice to evaluate the hepatic inflow, yet invasive. The phase-contrast-MRI(PC-MRI) is not invasive and potentially applicable in assessing the hepatic blood flow. In the present study, we compared the hepatic inflow rates using the PC-MRI and the TTUS probe, and evaluated their predictive value of post-hepatectomy adverse events. Methods: Eighteen large white pigs were anaesthetized for PC-MRI and approximately 75% hepatic resection was performed under a unified protocol. The blood flow was measured in the hepatic artery(Qha), the portal vein(Qpv), and the aorta above the celiac trunk(Qca) using PC-MRI, and was compared to the TTUS probe. The Bland-Altman method was conducted and a partial least squares regression(PLS) model was implemented. Results: The mean Qpv measured in PC-MRI was 0.55 ± 0.12 L/min, and in the TTUS probe was 0.74 ± 0.17 L/min. Qca was 1.40 ± 0.47 L/min in the PC-MRI and 2.00 ± 0.60 L/min in the TTUS probe. Qha was 0.17 ± 0.10 L/min in the PC-MRI, and 0.13 ± 0.06 L/min in the TTUS probe. The Bland-Altman method revealed that the estimated bias of Qca in the PC-MRI was 32%(95% CI:-49% to 15%); Qha 17%(95% CI:-15% to 51%); and Qpv 40%(95% CI:-62% to 18%). The TTUS probe had a higher weight in predicting adverse outcomes after 75% resection compared to the PC-MRI( β= 0.35 and 0.43 vs β = 0.22 and 0.07, for tissue changes and premature death, respectively). Conclusions: There is a tendency of the PC-MRI to underestimate the flow measured by the TTUS probes. The TTUS probe measures are more predictive of relevant post-hepatectomy outcomes.