期刊文献+
共找到383篇文章
< 1 2 20 >
每页显示 20 50 100
In vivo pilot study into superficial microcirculatory characteristics of colorectal adenomas using novel high-resolution magnifying endoscopy with blue laser imaging
1
作者 Hai-Bin Dong Tao Chen +2 位作者 Xiao-Fei Zhang Yu-Tang Ren Bo Jiang 《World Journal of Gastrointestinal Endoscopy》 2024年第4期206-213,共8页
BACKGROUND No studies have yet been conducted on changes in microcirculatory hemody-namics of colorectal adenomas in vivo under endoscopy.The microcirculation of the colorectal adenoma could be observed in vivo by a n... BACKGROUND No studies have yet been conducted on changes in microcirculatory hemody-namics of colorectal adenomas in vivo under endoscopy.The microcirculation of the colorectal adenoma could be observed in vivo by a novel high-resolution magnification endoscopy with blue laser imaging(BLI),thus providing a new insight into the microcirculation of early colon tumors.AIM To observe the superficial microcirculation of colorectal adenomas using the novel magnifying colonoscope with BLI and quantitatively analyzed the changes in hemodynamic parameters.METHODS From October 2019 to January 2020,11 patients were screened for colon adenomas with the novel high-resolution magnification endoscope with BLI.Video images were recorded and processed with Adobe Premiere,Adobe Photoshop and Image-pro Plus software.Four microcirculation parameters:Microcirculation vessel density(MVD),mean vessel width(MVW)with width standard deviation(WSD),and blood flow velocity(BFV),were calculated for adenomas and the surrounding normal mucosa.RESULTS A total of 16 adenomas were identified.Compared with the normal surrounding mucosa,the superficial vessel density in the adenomas was decreased(MVD:0.95±0.18 vs 1.17±0.28μm/μm2,P<0.05).MVW(5.11±1.19 vs 4.16±0.76μm,P<0.05)and WSD(11.94±3.44 vs 9.04±3.74,P<0.05)were both increased.BFV slowed in the adenomas(709.74±213.28 vs 1256.51±383.31μm/s,P<0.05).CONCLUSION The novel high-resolution magnification endoscope with BLI can be used for in vivo study of adenoma superficial microcirculation.Superficial vessel density was decreased,more irregular,with slower blood flow. 展开更多
关键词 ADENOMA MICROCIRCULATION High-resolution magnification endoscopy blue laser imaging
下载PDF
GaN-based blue laser diode with 6.0 W of output power under continuous-wave operation at room temperature 被引量:6
2
作者 Feng Liang Degang Zhao +5 位作者 Zongshun Liu Ping Chen Jing Yang Lihong Duan Yongsheng Shi Hai Wang 《Journal of Semiconductors》 EI CAS CSCD 2021年第11期70-72,共3页
In this work,we reported the room-temperature continuous-wave operation of 6.0 W GaN-based blue laser diode(LD),and its stimulated emission wavelength is around 442 nm.The GaN-based high power blue LD is grown on a c-... In this work,we reported the room-temperature continuous-wave operation of 6.0 W GaN-based blue laser diode(LD),and its stimulated emission wavelength is around 442 nm.The GaN-based high power blue LD is grown on a c-plane GaN substrate by metal organic chemical vapor deposition(MOCVD),and the width and length of the ridge waveguide structure are 30 and 1200μm,respectively.The threshold current is about 400 mA,and corresponding threshold current density is 1.1 kA/cm2. 展开更多
关键词 GAN blue laser diode high power
下载PDF
Effect of Droop Phenomenon in InGaN/GaN Blue Laser Diodes on Threshold Current
3
作者 范晓望 刘建平 +8 位作者 张峰 池田昌夫 李德尧 张书明 张立群 田爱琴 温鹏雁 马国宏 杨辉 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第9期109-111,共3页
Electroluminescence (EL) and temperature-dependent photolumineseenee measurements are performed to study the internal quantum efficiency droop phenomenon of blue laser diodes (LDs) before lasing. Based on the ABC ... Electroluminescence (EL) and temperature-dependent photolumineseenee measurements are performed to study the internal quantum efficiency droop phenomenon of blue laser diodes (LDs) before lasing. Based on the ABC mode, the EL result demonstrates that non-radiative recombination rates of LDs with threshold current densities of 4 and 6kA/cm2 are similar, while LD with threshold current density of 4kA/cm2 exhibits a smaller auger- like recombination rate compared with the one of 6kA/cm2. The internal quantum efficiency droop is more serious for LD with higher threshold current density. temperature-dependent photoluminescence is consistent The internal quantum efficiency value estimated from with EL measurements. 展开更多
关键词 INGAN LD Effect of Droop Phenomenon in InGaN/GaN blue laser Diodes on Threshold Current
下载PDF
Short Pulse Width and High Peak Power 457 nm Deep Blue Laser with V-Type Cavity
4
作者 Zhibin Zhao Cheng Cheng +5 位作者 Hao Chen Quan Li Yi Qu Guojun Liu Zhongliang Qiao Baoxue Bo 《Journal of Applied Mathematics and Physics》 2021年第11期2987-2994,共8页
<div style="text-align:justify;"> An intracavity frequency doubling acousto-optically Q-switched Neodymium-doped Yttrium Orthvanadate (Nd:YVO<sub>4</sub>) 457 nm blue laser by employing a t... <div style="text-align:justify;"> An intracavity frequency doubling acousto-optically Q-switched Neodymium-doped Yttrium Orthvanadate (Nd:YVO<sub>4</sub>) 457 nm blue laser by employing a three-mirror folded cavity was demonstrated. With the incident pump power of 40.4 W, the maximum average output power of 439 mW 457 nm laser, and the minimum pulse duration of 86.14 ns and the maximum peak power of 510 W were achieved at 10 kHz. The M<sup>2</sup> factors are 1.23 and 1.61 in X and Y directions, respectively. The power stability in two hours is better than 2%. </div> 展开更多
关键词 laser All-Solid-State laser Pulse Wave Deep blue laser 457 nm laser
下载PDF
Infrared Laser Pumped Green and Blue Laser Emissions from a Single Solid State Material Doped by Rare Earth Ions
5
作者 黄艺东 黄妙良 +1 位作者 陈雨金 罗遵度 《Journal of Rare Earths》 SCIE EI CAS CSCD 2003年第3期307-314,共8页
The possible ways and progress of infrared or red laser pumped green and blue laser emissions from a single solid state material doped by rare earth ions are outlined. The green and blue lasers realized from infrared ... The possible ways and progress of infrared or red laser pumped green and blue laser emissions from a single solid state material doped by rare earth ions are outlined. The green and blue lasers realized from infrared laser pumped rare earth doped nonlinear laser crystals by means of self frequency conversion and from infrared laser pumped rare earth doped bulk, fiber and microsphere materials by means of frequency upconversion are introduced in detail. Other kinds of devices and methods are also compared. The typical nonlinear laser crystals such as YAl 3(BO 3) 4, GdAl 3(BO 3) 4, YCa 4O(BO 3) 3 , GdCa 4O(BO 3) 3, and the typical upconversion fluoride fibers are compared and analyzed. The major problems remaining to be solved and the developing trends in the area are also discussed. 展开更多
关键词 OPTICS solid state laser material blue and green lasers rare earth
下载PDF
20.231 Gbit/s tricolor red/green/blue laser diode based bidirectional signal remodulation visible-light communication system 被引量:5
6
作者 LIANG-YU WEI CHIN-WEI HSU +1 位作者 CHI-WAI CHOW CHIEN-HUNG YEH 《Photonics Research》 SCIE EI 2018年第5期422-426,共5页
We propose and experimentally demonstrate a recorded 1-m bidirectional 20.231-Gbit/s tricolor R/G/B laser diode(LD) based visible-light communication(VLC) system supporting signal remodulation. In the signal remodulat... We propose and experimentally demonstrate a recorded 1-m bidirectional 20.231-Gbit/s tricolor R/G/B laser diode(LD) based visible-light communication(VLC) system supporting signal remodulation. In the signal remodulation system, an LD source is not needed at the client side. The client reuses the downstream signal sent from the central office(CO) and remodulates it to produce the upstream signal. As the LD sources are located at the CO, the laser wavelength and temperature managements at the cost-sensitive client side are not needed.This is the first demonstration, to our knowledge, of a >20 Gbit∕s data rate tricolor R/G/B VLC signal transmission supporting upstream remodulation. 展开更多
关键词 VLC LD Gbit/s tricolor red/green/blue laser diode based bidirectional signal remodulation visible-light communication system OOK
原文传递
Low-pump sum frequency generation of frequency- stabilized 453 nm blue laser for photonic quantum interface
7
作者 王健 潘宇豪 +2 位作者 黄运锋 李传锋 郭光灿 《Chinese Optics Letters》 SCIE EI CAS CSCD 2017年第12期82-85,共4页
Generation of a cavity-enhanced nondegenerate narrow-band photon pair source is a potential way to realize a perfect photonic quantum interface for a hybrid quantum network. However, to ensure the high quality of the ... Generation of a cavity-enhanced nondegenerate narrow-band photon pair source is a potential way to realize a perfect photonic quantum interface for a hybrid quantum network. However, to ensure the high quality of the photon source, the pump laser for the narrow-band photon source should be generated in a special way. Here, we experimentally generate the blue 453 nm laser with a sum frequency generation process in a periodically poled lithium niobate waveguide. A 13 mW laser at 453 nm can be achieved with a low-power 880 nm laser and 935 nm laser input, and the internal conversion efficiency is 21.6% after calculation. The frequency of a 453 nm laser is stabilized by locking two pump lasers on one ultrastable optical cavity. The single pass process without employ- ing cavity enhancement can ensure a good robustness of the whole system. 展开更多
关键词 Low-pump sum frequency generation of frequency-stabilized 453 nm blue laser for photonic quantum interface
原文传递
Room-temperature continuous-wave operation of GaN-based blue-violet laser diodes with a lifetime longer than 1000h 被引量:4
8
作者 Feng Liang Jing Yang +9 位作者 Degang Zhao Zongshun Liu Jianjun Zhu Ping Chen Desheng Jiang Yongsheng Shi Hai Wang Lihong Duan Liqun Zhang Hui Yang 《Journal of Semiconductors》 EI CAS CSCD 2019年第2期39-42,共4页
GaN-based continuous-wave operated blue-violet laser diodes(LDs) with long lifetime are demonstrated, which are grown on a c-plane GaN substrate by metal organic chemical vapor deposition with a 10 × 600 μm^2 ri... GaN-based continuous-wave operated blue-violet laser diodes(LDs) with long lifetime are demonstrated, which are grown on a c-plane GaN substrate by metal organic chemical vapor deposition with a 10 × 600 μm^2 ridge waveguide structure.The electrical and optical characteristics of a blue-violet LD are investigated under direct-current injection at room temperature(25 °C). The stimulated emission wavelength and peak optical power of the LD are around 413 nm and over 600 mW, respectively.In addition, the threshold current density and voltage are as small as 1.46 kA/cm^2 and 4.1 V, respectively. Moreover, the lifetime is longer than 1000 hours under room-temperature continuous-wave operation. 展开更多
关键词 GAN-BASED blue-violet laser DIODES long LIFETIME THRESHOLD voltage
下载PDF
Design of NO2 photoacoustic sensor with high reflective mirror based on low power blue diode laser 被引量:1
9
作者 靳华伟 谢品华 +3 位作者 胡仁志 黄崇崇 林川 王凤阳 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第6期139-145,共7页
An NO2 photoacoustic sensor system with a high reflective mirror based on a low power blue diode laser is developed in this work. The excitation power is enhanced by increasing the number of reflections. Comparing wit... An NO2 photoacoustic sensor system with a high reflective mirror based on a low power blue diode laser is developed in this work. The excitation power is enhanced by increasing the number of reflections. Comparing with a traditional photoacoustic system, the pool constant is improved from 300.24(Pa·cm)/W to 1450.64(Pa·cm)/W, and the signal sensitivity of the photoacoustic sensor is increased from 0.016 μV/ppb to 0.2562 μV/ppb. The characteristics of temperature and humidity of the new photoacoustic sensor are also obtained, and the algorithm is adjusted to provide a quantitative response and drift of the resonance frequency. The results of this research provide a new method and concept for further developing the NO2 photoacoustic sensors. 展开更多
关键词 NO2 photoacoustic sensor high reflective mirror blue diode laser
下载PDF
A 420nm Blue Diode Laser for the Potential Rubidium Optical Frequency Standard
10
作者 张盛楠 张晓刚 +6 位作者 涂建辉 蒋招杰 商浩森 祝传文 杨炜 崔敬忠 陈景标 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第7期118-121,共4页
We report a 42Ohm external cavity diode laser with an interference filter (IF) of 0.5am narrow-bandwidth and 79% high transmission, which is first used for Rb optical frequency standard. The IF and the cat-eye refle... We report a 42Ohm external cavity diode laser with an interference filter (IF) of 0.5am narrow-bandwidth and 79% high transmission, which is first used for Rb optical frequency standard. The IF and the cat-eye reflector are used for selecting wavelength and light feedback, respectively. The measured laser linewidth is 24 kHz when the diode laser is free running. Using this narrow-linewidth IF blue diode laser, we realize a compact Rb optical frequency standard without a complicated PDH system. The preliminary stability of the Rb optical frequency standard is 2 × 10^-13 at I s and decreases to 1.9 ×10^-14 at 1000s. The narrow-linewidth characteristic makes the IF blue diode laser a well suited candidate for the compact Rb optical frequency standard. 展开更多
关键词 A 420nm blue Diode laser for the Potential Rubidium Optical Frequency Standard RB KHZ
下载PDF
The Photopolymerization Kinetics of Acryl amide Sensitized with Toluidine Blue-Alcoholamine Induced by He-Ne Laser
11
作者 FENG Min-hui, HE Wei-qiang, HE Yi and LIANG Zhao-xi (Institute of Polymer Science, Zhongshan University, Guangzhou, 510275) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1993年第4期329-334,共6页
Toluidine blue(TB) is a good sensitizer for the polymerization of acrylnmide(AM) induced by He-Ne laser. With TB as a sensitizer and various alcoholamine as donors, the photoredox of TB and the polymerization kinetics... Toluidine blue(TB) is a good sensitizer for the polymerization of acrylnmide(AM) induced by He-Ne laser. With TB as a sensitizer and various alcoholamine as donors, the photoredox of TB and the polymerization kinetics of AM induced by He-Ne laser were investigated. It was found that either for the photoredox of TB or for the polymerization of AM, the activity of alcoholamine increases in the order of EOA<DEOA <TEOA in TB-alcoholamine sensitized system. The overall apparent kinetic equations of AM polymerization at 30℃ have been determined. In addition, the molecular weights under various conditions was measured. 展开更多
关键词 He-Ne laser PHOTOPOLYMERIZATION Acryiamide Toluidine blue Alcoho-lamine
下载PDF
超声内镜结合LCI/BLI-ME判断根除幽门螺杆菌后早期胃癌浸润深度的研究
12
作者 周晓黎 舒磊 +3 位作者 杨林 杨健 廖艳 时昭红 《华中科技大学学报(医学版)》 CAS CSCD 北大核心 2024年第1期39-44,51,共7页
目的 探讨超声内镜结合联动成像技术/蓝激光成像技术-放大内镜(LCI/BLI-ME)对根除幽门螺杆菌后早期胃癌浸润深度的判断及其准确性的影响因素,评价其临床应用价值。方法 收集2017年10月至2023年6月武汉市第一医院收治的91例根除幽门螺杆... 目的 探讨超声内镜结合联动成像技术/蓝激光成像技术-放大内镜(LCI/BLI-ME)对根除幽门螺杆菌后早期胃癌浸润深度的判断及其准确性的影响因素,评价其临床应用价值。方法 收集2017年10月至2023年6月武汉市第一医院收治的91例根除幽门螺杆菌后早期胃癌患者的临床资料,以病理学检查结果作为判断标准,总结根除幽门螺杆菌后胃黏膜及早期胃癌在内镜下的特征表现,分析超声内镜结合LCI/BLI-ME对根除幽门螺杆菌后早期胃癌浸润深度的判断准确性及影响其判断准确性的相关因素。诊断效能的统计学描述采用灵敏度、特异度、准确度表示;采用χ^(2)检验和多因素Logistic回归分析对超声内镜的诊断结果与术后病理学检查结果进行比较。结果 超声内镜结合LCI/BLI-ME对根除幽门螺杆菌后早期胃癌浸润深度判断的总体准确率77.08%,对uT1a期及uT1b期的判断准确率分别为82.86%和61.53%。分期不足12例,占17.14%;分期过度10例,占38.46%。对黏膜层病变判断的诊断敏感度85.29%,诊断特异度57.14%,阳性预测值82.86%,阴性预测值61.5%。单因素和多因素Logistic回归分析结果表明,病变最大径、组织分化类型是影响判断准确性的因素,而病变部位、病灶形态与判断准确性无相关性。病灶越大,对浸润深度判断的准确性越低;组织分化程度越低,对浸润深度判断的准确性越低。结论 超声内镜结合LCI/BLI-ME对根除幽门螺杆菌后早期胃癌uT1a期的浸润深度判断具有较好的临床应用价值,病灶大小及组织分化程度对判断的准确性有影响。 展开更多
关键词 早期胃癌 超声内镜 联动成像技术 蓝激光成像技术
下载PDF
区级医院开展经尿道450 nm蓝激光前列腺汽化术的初步报道
13
作者 李涛 陈礼达 +3 位作者 王忠义 田永峰 曹琦瑞 聂杨波 《现代泌尿外科杂志》 CAS 2024年第4期324-326,341,共4页
目的初步探讨在区级医院开展经尿道450 nm蓝激光前列腺汽化术治疗良性前列腺增生(BPH)的临床效果,为区级医院BPH治疗方法的选择提供参考。方法回顾性分析2023年1月—9月在西安市长安区医院泌尿外科接受手术治疗的39例BPH患者的临床资料... 目的初步探讨在区级医院开展经尿道450 nm蓝激光前列腺汽化术治疗良性前列腺增生(BPH)的临床效果,为区级医院BPH治疗方法的选择提供参考。方法回顾性分析2023年1月—9月在西安市长安区医院泌尿外科接受手术治疗的39例BPH患者的临床资料。根据手术方式分为两组,其中蓝激光组(n=19)行经尿道450 nm蓝激光前列腺汽化术,电切组(n=20)行经尿道前列腺电切术(TURP)。比较两组患者的手术时间、血红蛋白下降值、术后膀胱冲洗时间、术后留置尿管时间及并发症发生情况。结果所有患者的手术均顺利完成。两组的手术时间[(45.11±22.08)min vs.(81.25±29.37)min]、术后膀胱冲洗时间[(34.05±9.41)h vs.(47.60±9.05)h]及血红蛋白下降值[(7.79±5.86)g/L vs.(16.40±10.23)g/L]比较,蓝激光组明显低于电切组(P<0.05)。蓝激光组术后尿潴留1例,两组术后留置尿管时间差异无统计学意义(P>0.05)。结论采用450 nm蓝激光前列腺汽化术治疗BPH具有出血量少、手术时间短及术后膀胱冲洗时间少的特点,值得在基层医院推广应用。 展开更多
关键词 良性前列腺增生 450 nm蓝激光 前列腺汽化切除术 经尿道前列腺电切术
下载PDF
高转换效率腔内倍频外腔面发射蓝光激光器
14
作者 伍亚东 朱仁江 +6 位作者 晏日 彭雪芳 王涛 蒋丽丹 佟存柱 宋晏蓉 张鹏 《物理学报》 SCIE EI CAS CSCD 北大核心 2024年第1期174-180,共7页
高功率高光束质量的蓝色激光在激光显示与照明、水下通信和成像、有色金属加工等许多领域具有广泛应用前景.本文利用增益芯片底部的高反镜分布布拉格反射镜、折叠镜以及后端反射镜构成V型谐振腔,通过腔内插入非线性晶体LBO,获得了高转... 高功率高光束质量的蓝色激光在激光显示与照明、水下通信和成像、有色金属加工等许多领域具有广泛应用前景.本文利用增益芯片底部的高反镜分布布拉格反射镜、折叠镜以及后端反射镜构成V型谐振腔,通过腔内插入非线性晶体LBO,获得了高转换效率的高功率、高光束质量蓝光输出.实验研究了非线性晶体的长度、基频激光的线宽、倍频走离角的补偿等不同因素对外腔面发射激光器腔内倍频蓝光输出功率的影响.在LBO的Ⅰ类相位匹配条件下,当晶体长度为5 mm,所用双折射滤波片厚度为1 mm时,获得超过6 W的491 nm波长蓝光输出,x和y方向的光束质量M2因子均为1.08,倍频转换效率为63%. 展开更多
关键词 腔内倍频 外腔面发射蓝光激光器 Ⅰ类相位匹配 走离角补偿
下载PDF
450 nm蓝激光半导体治疗机6点位置定位法治疗中叶增生型良性前列腺增生的疗效观察
15
作者 屠凡倬 郝晓航 +6 位作者 胡燕 胡遵杰 李松 高文举 刘飞 王昊星 赵永伟 《现代泌尿外科杂志》 CAS 2024年第4期320-323,共4页
目的评估450 nm蓝激光半导体治疗机6点位置定位法治疗中叶增生型良性前列腺增生(BPH)的疗效及安全性,以期推广该术式的临床应用。方法回顾性分析2023年3月—8月在泰安市中心医院迎胜院区泌尿肾病激光治疗中心行450 nm蓝激光半导体治疗机... 目的评估450 nm蓝激光半导体治疗机6点位置定位法治疗中叶增生型良性前列腺增生(BPH)的疗效及安全性,以期推广该术式的临床应用。方法回顾性分析2023年3月—8月在泰安市中心医院迎胜院区泌尿肾病激光治疗中心行450 nm蓝激光半导体治疗机6点位置定位法治疗20例中叶增生型BPH患者的临床资料,记录手术时间、术后膀胱冲洗时间、尿管留置时间、术后住院时间、手术并发症。比较患者术前及术后1个月最大尿流率(Qmax)、膀胱残余尿量(PVR)、生活质量评分(QoL)、国际前列腺症状评分(IPSS)变化情况。结果本组患者手术时间为(26.80±7.22)min,术后膀胱冲洗时间为(20.50±1.79)h,所有患者术后次日拔除导尿管,术后2 d顺利出院。与术前比较,患者术后1个月的Qmax显著升高[(7.40±1.05)mL/s vs.(19.60±1.76)mL/s]、PVR[(73.50±12.26)mL vs.(9.25±4.94)mL]、QoL[(4.55±1.19)分vs.(1.95±0.95)分]、IPSS[(26.55±1.88)分vs.(10.05±1.36)分]均显著降低,差异具有统计学意义(P<0.05)。术中及术后1个月随访期间无任何并发症发生。结论450 nm蓝激光半导体治疗机6点位置定位法治疗中叶增生型BPH是一种新型、安全、有效的手术方式,值得在临床推广应用。 展开更多
关键词 450 nm蓝激光 前列腺汽化术 6点位置定位法 中叶增生型前列腺 良性前列腺增生
下载PDF
450 nm半导体蓝激光“打沟去垄法”治疗大体积良性前列腺增生的疗效 观察
16
作者 屠凡倬 陈宪艳 +5 位作者 曲亚萍 李松 胡燕 满超 葛长官 赵永伟 《现代泌尿外科杂志》 CAS 2024年第5期435-439,共5页
目的分析450 nm半导体蓝激光“打沟去垄法”治疗大体积良性前列腺增生(BPH)的疗效及安全性,以期在临床推广应用。方法回顾性分析2023年9—12月泰安市中心医院迎胜院区泌尿肾病激光治疗中心行450 nm半导体蓝激光“打沟去垄法”治疗30例... 目的分析450 nm半导体蓝激光“打沟去垄法”治疗大体积良性前列腺增生(BPH)的疗效及安全性,以期在临床推广应用。方法回顾性分析2023年9—12月泰安市中心医院迎胜院区泌尿肾病激光治疗中心行450 nm半导体蓝激光“打沟去垄法”治疗30例大体积BPH患者的临床资料,记录患者术中激光出光做功时间、术前及术后血红蛋白(Hb)水平、术后膀胱冲洗时间、尿管留置时间、术后住院时间、术中及术后并发症发生情况。对比患者术前及术后1个月国际前列腺症状评分(IPSS)、生活质量评定量表(QoL)评分、最大尿流率(Qmax)、膀胱残余尿量(PVR)变化情况。结果患者术前前列腺体积为(104.5±14.52)mL,术中激光出光做功时间(20.13±2.98)min,术后膀胱冲洗时间(20.27±2.56)h。所有患者术后2 d拔除导尿管,术后3 d顺利出院。术后1个月IPSS、QoL评分、Qmax、PVR均较术前明显改善,差异有统计学意义(P<0.05)。在随访期间未观察到任何并发症发生。结论采用450 nm半导体蓝激光“打沟去垄法”治疗大体积BPH是一种新型、安全、有效的手术方式。 展开更多
关键词 450 nm蓝激光 前列腺汽化术 打沟去垄法 大体积 良性前列腺增生
下载PDF
蓝激光前列腺汽化切除术对良性前列腺增生患者术后性功能及下尿路症状的影响
17
作者 徐晓龙 满超 +2 位作者 岳传超 赵永伟 郝晓航 《现代泌尿外科杂志》 CAS 2024年第6期501-504,509,共5页
目的分析蓝激光前列腺汽化切除术治疗良性前列腺增生(BPH)的临床效果及对患者术后性功能及下尿路症状(LUTS)的影响。方法回顾性分析2023年3—8月在泰安市中心医院迎胜院区泌尿肾病激光治疗中心接受手术治疗的91例BPH患者的临床资料,根... 目的分析蓝激光前列腺汽化切除术治疗良性前列腺增生(BPH)的临床效果及对患者术后性功能及下尿路症状(LUTS)的影响。方法回顾性分析2023年3—8月在泰安市中心医院迎胜院区泌尿肾病激光治疗中心接受手术治疗的91例BPH患者的临床资料,根据不同手术方式分为两组,蓝激光组(n=46)采用经尿道蓝激光前列腺汽化切除术,PKRP组(n=45)采用经尿道前列腺等离子电切术(PKRP)。比较两组患者的手术时间、膀胱冲洗时间、留置尿管时间、住院时间,术前、术后6个月的残余尿量(PVR)、最大尿流率(Qmax)、国际前列腺症状评分(IPSS)、生活质量评分(QoL)、国际勃起功能指数-5(IIEF-5)问卷、射精功能评分量表(CIPE)评分以及逆行射精发生率。结果两组手术时间[(24.66±5.38)min vs.(62.50±3.85)min]、膀胱冲洗时间[(20.40±2.78)h vs.(51.93±5.02)h]、留置尿管时间[(1.65±0.89)d vs.(6.73±2.98)d]及住院时间[(4.26±1.57)d vs.(8.45±2.28)d]比较,蓝激光组均明显短于PKRP组(P<0.05)。两组患者术前及术后6个月Qmax、PVR、QoL及IPSS比较差异无统计学意义(P>0.05)。术后6个月蓝激光组较PKRP组的IIEF-5问卷[(20.02±2.63)分vs.(17.64±1.75)分]及CIPE评分更高[(30.88±3.45)分vs.(26.25±3.51)分],差异具有统计学意义(P<0.05)。蓝激光组术后6个月的逆行射精发生率低于PKRP组(4.35%vs.35.60%,P<0.05)。结论蓝激光前列腺汽化切除术能够改善BPH患者LUTS,并且更好的保护了患者的性功能。 展开更多
关键词 蓝激光前列腺汽化切除术 性功能 逆行射精 经尿道前列腺等离子电切术 良性前列腺增生 下尿路症状
下载PDF
450 nm蓝激光汽化术治疗良性前列腺增生患者30例初步经验
18
作者 张栋邦 胡森 +3 位作者 童占表 马有才 尚梦蕾 景钦香 《现代泌尿外科杂志》 CAS 2024年第6期497-500,共4页
目的分析450 nm蓝激光汽化术治疗良性前列腺增生(BPH)患者的临床效果并总结初步经验。方法选取2023年6—9月青海红十字医院泌尿外科收治的接受经尿道450 nm蓝激光汽化术治疗的30例BPH患者的临床资料。记录手术操作时间、血红蛋白下降值... 目的分析450 nm蓝激光汽化术治疗良性前列腺增生(BPH)患者的临床效果并总结初步经验。方法选取2023年6—9月青海红十字医院泌尿外科收治的接受经尿道450 nm蓝激光汽化术治疗的30例BPH患者的临床资料。记录手术操作时间、血红蛋白下降值、膀胱冲洗时间、导尿管留置时间及并发症发生情况。比较患者术前、术后3个月的国际前列腺症状评分(IPSS)、生活质量评分(QoL)、膀胱残余尿量(PVR)和最大尿流率(Qmax)指标变化。结果患者均顺利完成手术,术中无中转经尿道前列腺电切术(TURP)及开放手术。手术操作时间(38.2±7.5)min,术后24 h血红蛋白下降值(10.4±3.5)g/L,膀胱冲洗时间(15.1±3.3)h,导尿管留置时间(4.5±0.5)d。相较于术前,术后3个月患者的IPSS[(26.28±2.22)分vs.(6.29±2.10)分]、QoL[(5.25±0.85)分vs.(2.33±0.95)分]、PVR均显著降低[(397.89±8.47)mL vs.(15.62±2.17)mL],Qmax显著升高[(8.15±2.09)mL/s vs.(19.50±2.51)mL/s],差异均具有统计学意义(P<0.05)。术中膀胱黏膜轻度损伤2例(6.6%),术后二次留置导尿管1例(3.3%),术后肉眼血尿1例(3.3%),未发生严重并发症。结论采用450 nm蓝激光汽化术治疗BPH患者具有快速高效、止血可靠、并发症低的优点,可有效改善患者排尿情况,值得临床推广应用。 展开更多
关键词 良性前列腺增生 450 nm蓝激光 经尿道前列腺电切术 前列腺汽化切除
下载PDF
BLI-ME对早期食管癌的诊断价值及B2型血管对浸润深度的判断
19
作者 刘黎 魏文俊 《蚌埠医学院学报》 CAS 2024年第5期619-622,共4页
目的:探讨蓝激光成像联合放大内镜(BLI-ME)观察下食管病变上皮内乳头状毛细血管环(IPCLs)分型对早期食管癌(EEC)的诊断价值及预估病变浸润深度的能力。方法:回顾性分析168例(174处病灶)可疑食管病变病人的临床资料,分析IPCLs对食管病变... 目的:探讨蓝激光成像联合放大内镜(BLI-ME)观察下食管病变上皮内乳头状毛细血管环(IPCLs)分型对早期食管癌(EEC)的诊断价值及预估病变浸润深度的能力。方法:回顾性分析168例(174处病灶)可疑食管病变病人的临床资料,分析IPCLs对食管病变性质及浸润深度的预判作用。结果:BLI-ME诊断IPCLs A型病变中92.98%(53/57)病理诊断为食管炎,IPCLs B型病变中97.44%(114/117)病理诊断为EEC及癌前病变。BLI-ME观察下,术前活检病理与术后完整病理一致度尚可(Kappa=0.573>0.4,P<0.01);B1、B2、B3型IPCLs分型预判食管病变浸润深度的准确率分别为89.86%、61.90%、100.00%。结论:BLI-ME观察下对可疑食管病变黏膜IPCLs改变进行分型,有助于对食管黏膜性质及病变浸润深度的判断,同时在BLI-ME下靶向活检可实现对病变的精准预估,从而为治疗方案提供参考。 展开更多
关键词 早期食管癌 癌前病变 蓝激光成像
下载PDF
450 nm半导体蓝激光前列腺汽化切除术治疗40例良性前列腺增生患者的疗效观察
20
作者 王宇 徐炜 +4 位作者 周发友 徐瑞 谢辉 崔强 郭松林 《现代泌尿外科杂志》 CAS 2024年第5期432-434,444,共4页
目的评估450 nm半导体蓝激光前列腺汽化切除术治疗良性前列腺增生(BPH)的手术疗效及安全性。方法回顾性分析皖南医学院第二附属医院泌尿外科2023年3—11月40例采用450 nm半导体蓝激光前列腺汽化切除术治疗的BPH患者临床资料,比较患者手... 目的评估450 nm半导体蓝激光前列腺汽化切除术治疗良性前列腺增生(BPH)的手术疗效及安全性。方法回顾性分析皖南医学院第二附属医院泌尿外科2023年3—11月40例采用450 nm半导体蓝激光前列腺汽化切除术治疗的BPH患者临床资料,比较患者手术前后的最大尿流率(Qmax)、残余尿量(PVR)、国际前列腺症状评分(IPSS)、生活质量评定量表(QoL)评分变化及手术时间、术后膀胱冲洗时间和术后血红蛋白下降值。结果40例患者均顺利完成手术。患者术后1月Qmax明显高于术前[(16.8±2.5)mL/s vs.(7.9±2.1)mL/s,P<0.05],术后PVR明显低于术前[(14.6±11.4)mL vs.(110.0±42.1)mL,P<0.05],术后IPSS[(11.8±4.0)分vs.(25.0±3.1)分,P<0.05]及QoL评分均明显低于术前[(2.5±0.6)分vs.(5.1±0.9)分,P<0.05]。患者手术时间(52.5±15.5)min,术后膀胱冲洗时间(22.3±4.9)h,术后血红蛋白下降值(6.5±3.8)g/L。2例患者拔除尿管后再次予以导尿,1例患者出院后出现血尿。结论450 nm半导体蓝激光前列腺汽化切除术可显著改善BPH患者的临床症状,提高围手术期的安全性,具有汽化效率高、止血效果好等特点,值得在临床推广应用。 展开更多
关键词 450 nm蓝激光 前列腺汽化切除术 良性前列腺增生
下载PDF
上一页 1 2 20 下一页 到第
使用帮助 返回顶部