AIM: To check the usefulness of blue mode (BM) review in lewis score (LS) calculation, by comparing it with respective LS results obtained by white light (WL) small-bowel capsule endoscopy (SBCE) review and mucosal in...AIM: To check the usefulness of blue mode (BM) review in lewis score (LS) calculation, by comparing it with respective LS results obtained by white light (WL) small-bowel capsule endoscopy (SBCE) review and mucosal inflammation as reflected by faecal calprotectin (FC) levels, considered as ‘gold standard’ for this study. METHODS: Computational analysis of our SBCE database to identify patients who underwent SBCE with PillCam? and had FC measured within a 30-day period from their test. Only patients with prior colonoscopy were included, to exclude any colon pathology-associated FC rise. Each small bowel tertile was reviewed (viewing speed 8 fps) with WL and BM, in a back-to-back mode, by a single experienced reviewer. LS were calculated after each WL and BM reviews. Pearson rank correlation (rho, r) statistic was applied. RESULTS: Twenty-seven (n = 27, 20F/7M) patients were included. Thirteen (n = 13) had SBCE with PillCam?SB1, and the remainder (n = 14) with PillCam?SB2. The median level of FC in this cohort was 125 μg/g. LS (calculated in WL SBCE review) correlation with FC levels was r = 0.490 (P = 0.01), while for BM review and LS correlation with FC was r = 0.472 (P = 0.013). CONCLUSION: Although BM is believed to enhance mucosal details i.e., small mucosal breaks, it did not perform better than WL in the calculation of LS in our cohort.展开更多
In this study, two-section mode-locked semiconductor lasers with different numbers of quantum wells and different types of waveguide structures are made. Their ultrashort pulse features are presented. The spectral dyn...In this study, two-section mode-locked semiconductor lasers with different numbers of quantum wells and different types of waveguide structures are made. Their ultrashort pulse features are presented. The spectral dynamical behaviors in these lasers are studied in detail. In the simulation part, a two-band compressive-strained quantum well(QW) model is used to study thermally induced band-edge detuning in the amplifier and saturable absorber(SA). A sudden blue shift in laser spectrum is expected by calculating the peak of the net gain. In the experiment part, the sudden blue shift in the emission spectrum is observed in triple QW samples under certain operating conditions but remains absent in single QW samples.Experimental results reveal that blue shift phenomenon is connected with the difference between currents in two sections.Additionally, a threshold current ratio for blue-shift is also demonstrated.展开更多
A helicon wave plasma source in a tube of ring permanent magnets(PMs)has been constructed to study the effect of the conflguration of the magnetic fleld with zero magnetic points on plasma parameters.This device also ...A helicon wave plasma source in a tube of ring permanent magnets(PMs)has been constructed to study the effect of the conflguration of the magnetic fleld with zero magnetic points on plasma parameters.This device also serves as an exploration platform for a simple,compact helicon wave plasma source adaptable to engineering applications.A small-diameter(26 mm)highdensity(~10^(18)m^(-3))blue core plasma is produced in~1 Pa argon by helicon RF(radiofrequency)discharge using a NagoyaⅢantenna under magnetic fleld(~2 k G)of compact ring PMs(length~204 mm).Operational parameters,i.e.RF power and neutral gas pressure are scanned and plasma density is measured by an RF compensated probe to explore the operating characteristics of the device.Iconic feature of a helicon discharge,such as blue core plasmas and E-H-W mode transitions are well observed in the device,despite the wavelength calculated using the conventional dispersion relation of a bounded whistler waves(Chen 1991 Plasma Phys.Control.Fusion 33339)is order of magnitudes longer than the length of the plasma in this device which seems to suggest that such helicon device is impossible.Surprisingly,the wavelength calculated by the unbounded whistle wave dispersion formula in turn suggests the occurrence of a half wavelength resonance.展开更多
We report a direct blue-diode-pumped wavelength tunable Kerr-lens mode-locked Ti: sapphire laser.Central wavelength tunability as broad as 89 nm(736-825 nm) is achieved by adjusting the insertion of the prism.Pulses a...We report a direct blue-diode-pumped wavelength tunable Kerr-lens mode-locked Ti: sapphire laser.Central wavelength tunability as broad as 89 nm(736-825 nm) is achieved by adjusting the insertion of the prism.Pulses as short as 17 fs are generated at a central wavelength of 736 nm with an average output power of 31 mW.The maximum output power is 46.8 mW at a central wavelength of 797 nm with a pulse duration of 46 fs.展开更多
文摘AIM: To check the usefulness of blue mode (BM) review in lewis score (LS) calculation, by comparing it with respective LS results obtained by white light (WL) small-bowel capsule endoscopy (SBCE) review and mucosal inflammation as reflected by faecal calprotectin (FC) levels, considered as ‘gold standard’ for this study. METHODS: Computational analysis of our SBCE database to identify patients who underwent SBCE with PillCam? and had FC measured within a 30-day period from their test. Only patients with prior colonoscopy were included, to exclude any colon pathology-associated FC rise. Each small bowel tertile was reviewed (viewing speed 8 fps) with WL and BM, in a back-to-back mode, by a single experienced reviewer. LS were calculated after each WL and BM reviews. Pearson rank correlation (rho, r) statistic was applied. RESULTS: Twenty-seven (n = 27, 20F/7M) patients were included. Thirteen (n = 13) had SBCE with PillCam?SB1, and the remainder (n = 14) with PillCam?SB2. The median level of FC in this cohort was 125 μg/g. LS (calculated in WL SBCE review) correlation with FC levels was r = 0.490 (P = 0.01), while for BM review and LS correlation with FC was r = 0.472 (P = 0.013). CONCLUSION: Although BM is believed to enhance mucosal details i.e., small mucosal breaks, it did not perform better than WL in the calculation of LS in our cohort.
基金Project supported by the National Basic Research Program of China(Grant Nos.2013CB933304 and 2012CB932701)the National Natural Science Foundation of China(Grant Nos.61274125 and 61435012)the Strategic Priority Research Program(B)of the Chinese Academy of Sciences(Grant No.XDB01010200)
文摘In this study, two-section mode-locked semiconductor lasers with different numbers of quantum wells and different types of waveguide structures are made. Their ultrashort pulse features are presented. The spectral dynamical behaviors in these lasers are studied in detail. In the simulation part, a two-band compressive-strained quantum well(QW) model is used to study thermally induced band-edge detuning in the amplifier and saturable absorber(SA). A sudden blue shift in laser spectrum is expected by calculating the peak of the net gain. In the experiment part, the sudden blue shift in the emission spectrum is observed in triple QW samples under certain operating conditions but remains absent in single QW samples.Experimental results reveal that blue shift phenomenon is connected with the difference between currents in two sections.Additionally, a threshold current ratio for blue-shift is also demonstrated.
基金supported by National Natural Science Foundation of China(No.U19A20113)。
文摘A helicon wave plasma source in a tube of ring permanent magnets(PMs)has been constructed to study the effect of the conflguration of the magnetic fleld with zero magnetic points on plasma parameters.This device also serves as an exploration platform for a simple,compact helicon wave plasma source adaptable to engineering applications.A small-diameter(26 mm)highdensity(~10^(18)m^(-3))blue core plasma is produced in~1 Pa argon by helicon RF(radiofrequency)discharge using a NagoyaⅢantenna under magnetic fleld(~2 k G)of compact ring PMs(length~204 mm).Operational parameters,i.e.RF power and neutral gas pressure are scanned and plasma density is measured by an RF compensated probe to explore the operating characteristics of the device.Iconic feature of a helicon discharge,such as blue core plasmas and E-H-W mode transitions are well observed in the device,despite the wavelength calculated using the conventional dispersion relation of a bounded whistler waves(Chen 1991 Plasma Phys.Control.Fusion 33339)is order of magnitudes longer than the length of the plasma in this device which seems to suggest that such helicon device is impossible.Surprisingly,the wavelength calculated by the unbounded whistle wave dispersion formula in turn suggests the occurrence of a half wavelength resonance.
基金Project supported by the National Key R&D Program of China(Grant No.2016YFB0402105)
文摘We report a direct blue-diode-pumped wavelength tunable Kerr-lens mode-locked Ti: sapphire laser.Central wavelength tunability as broad as 89 nm(736-825 nm) is achieved by adjusting the insertion of the prism.Pulses as short as 17 fs are generated at a central wavelength of 736 nm with an average output power of 31 mW.The maximum output power is 46.8 mW at a central wavelength of 797 nm with a pulse duration of 46 fs.