Numerical Optimization by Finite Element Method of Stainless Steel/Glass-Epoxy Composite Bolted Joint under Tension and Compression
1
作者 Christian Schmitt Arnaud Kremeur +1 位作者 Pawel Lipinski Julien Capelle 《Engineering(科研)》 2024年第4期102-122,共21页
The aim of this study was to optimize the geometry and the design of metallic/composite single bolted joints subjected to tension-compression loading. For this purpose, it was necessary to evaluate the stress state in... The aim of this study was to optimize the geometry and the design of metallic/composite single bolted joints subjected to tension-compression loading. For this purpose, it was necessary to evaluate the stress state in each component of the bolted join. The multi-material assembly was based on the principle of double lap bolted joint. It was composed of a symmetrical balanced woven glass-epoxy composite material plate fastened to two stainless sheets using a stainless pre-stressed bolt. In order to optimize the design and the geometry of the assembly, ten configurations were proposed and studied: a classical simple bolted joint, two joints with an insert (a BigHead<sup>R</sup> insert and a stair one) embedded in the composite, two “waved” solutions, three symmetrical configurations composed of a succession of metallic and composites layers, without a sleeve, with one and with two sleeves, and two non-symmetrical constituted of metallic and composites layers associated with a stair-insert (one with a sleeve and one without). A tridimensional Finite Element Method (FEM) was used to model each configuration mentioned above. The FE models taked into account the different materials, the effects of contact between the different sheets of the assembly and the pre-stress in the bolt. The stress state was analyzed in the composite part. The concept of stress concentration factor was used in order to evaluate the stress increase in the highly stressed regions and to compare the ten configurations studied. For this purpose, three stress concentration factors were defined: one for a monotonic loading in tension, another for a monotonic loading in compression, and the third for a tension-compression cyclic loading. The results of the FEM computations showed that the use of alternative metallic and composite layers associated with two sleeves gived low values of stress concentration factors, smaller than 1.4. In this case, there was no contact between the bolt and the composite part and the most stressed region was not the vicinity of the hole but the end of the longest layers of the metallic inserts. 展开更多
关键词 bolted Joint Glass-Epoxy Composite CLEARANCE Hybrid Steel-Composite
下载PDF
Experimental study on the shear performance of quasi-NPR steel bolted rock joints 被引量:4
2
作者 Manchao He Shulin Ren +3 位作者 Haotian Xu Senlin Luo Zhigang Tao Chun Zhu 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2023年第2期350-362,共13页
Quasi-NPR(negative Poisson’s ratio)steel is a new type of super bolt material with high strength,high ductility,and a micro-negative Poisson’s effect.This material overcomes the contrasting characteristics of the hi... Quasi-NPR(negative Poisson’s ratio)steel is a new type of super bolt material with high strength,high ductility,and a micro-negative Poisson’s effect.This material overcomes the contrasting characteristics of the high strength and high ductility of steel and it has significant energy-absorbing characteristics,which is of high value in deep rock and soil support engineering.However,research on the shear resistance of quasi-NPR steel has not been carried out.To study the shear performance of quasi-NPR steel bolted rock joints,indoor shear tests of bolted rock joints under different normal stress conditions were carried out.Q235 steel and#45 steel,two representative ordinary bolt steels,were set up as a control group for comparative tests to compare and analyze the shear strength,deformation and instability mode,shear energy absorption characteristics,and bolting contribution of different types of bolts.The results show that the jointed rock masses without bolt reinforcement undergo brittle failure under shear load,while the bolted jointed rock masses show obvious ductile failure characteristics.The shear deformation ca-pacity of quasi-NPR steel is more than 3.5 times that of Q235 steel and#45 steel.No fracture occurs in the quasi-NPR steel during large shear deformation and it can provide stable shear resistance.However,the other two types of control bolts become fractured under the same conditions.Quasi-NPR steel has significant energy-absorbing characteristics under shear load and has obvious advantages in terms of absorbing the energy released by shear deformation of jointed rock masses as compared with ordinary steel.In particular,the shear force plays a major role in resisting the shear deformation of Q235 steel and#45 steel,therefore,fracture failure occurs under small bolt deformation.However,the axial force of quasi-NPR steel can be fully exerted when resisting joint shear deformation;the steel itself does not break when large shear deformation occurs,and the supporting effect of the jointed rock mass is effectively guaranteed. 展开更多
关键词 Energy absorption bolt Quasi-NPR(Negative Poisson’s ratio)steel bolted rock joints Shear test Shear performance
下载PDF
Residual Capacity of Friction⁃Type High⁃Strength Bolted T⁃stub Connection with Nut Corrosion Damage
3
作者 Gangnian Xu Baoyao Lin Yefeng Du 《Journal of Harbin Institute of Technology(New Series)》 CAS 2023年第3期68-84,共17页
Corrosion is a primary cause of the slippage of friction⁃type high⁃strength bolted(FHSB)T⁃stub connections.This paper attempts to quantify the residual capacity of FHSB T⁃stub connections with corroded nuts.Firstly,co... Corrosion is a primary cause of the slippage of friction⁃type high⁃strength bolted(FHSB)T⁃stub connections.This paper attempts to quantify the residual capacity of FHSB T⁃stub connections with corroded nuts.Firstly,corrosion simulation tests were conducted on 48 manually cut nuts to find out the relationship between the damage degree of nut section and the residual clamping force(RCF)of bolt.Then,static load tests were carried out on 24 FHSB T⁃stub connections with nuts of different degrees of damage to obtain the failure modes.By finite⁃element(FE)models,a comparative analysis was performed on the initial friction load(IFL)and ultimate strength(US)of each connection with corroded nuts.Finally,the parameters of 96 FE models for FHSB T⁃stub connections were analyzed and used to derive the calculation formulas for the degree of damage for each nut and the IFL and US of each connection.The results show that the RCF decay of a bolt is a quadratic function of the equivalent radius loss ratio and the shear failure after nut corrosion;the IFL of each connection had a clear linear correlation with the RCF of the corresponding bolts,and the correlation depends on the applied load and static friction on connecting plate interface induced by the clamping force;the static friction had little impact on the US of the connection;the proposed IFL and US formulas can effectively derive the residual anti⁃slip capacity of FHSB T⁃stub connections from the degree of damage of the corroded nut section.The research results provide a scientific basis for the replacement and maintenance of corroded bolts of FHSB T⁃stub connections. 展开更多
关键词 nut corrosion T⁃stub connection high⁃strength bolt sectional damage residual clamping force(RCF) anti⁃slip capacity
下载PDF
Theory,technology and application of grouted bolting in soft rock roadways of deep coal mines
4
作者 Hongpu Kang Jianwei Yang +4 位作者 Pengfei Jiang Fuqiang Gao Wenzhou Li Jiafeng Li Huiyuan Chen 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2024年第7期1463-1479,共17页
The grouted bolt,combining rock bolting with grouting techniques,provides an effective solution for controlling the surrounding rock in deep soft rock and fractured roadways.It has been extensively applied in numerous... The grouted bolt,combining rock bolting with grouting techniques,provides an effective solution for controlling the surrounding rock in deep soft rock and fractured roadways.It has been extensively applied in numerous deep mining areas characterized by soft rock roadways,where it has demonstrated remarkable control results.This article systematically explores the evolution of grouted bolting,covering its theoretical foundations,design methods,materials,construction processes,monitoring measures,and methods for assessing its effectiveness.The overview encompassed several key elements,delving into anchoring theory and grouting reinforcement theory.The new principle of high pretensioned high-pressure splitting grouted bolting collaborative active control is introduced.A fresh method for dynamic information design is also highlighted.The discussion touches on both conventional grouting rock bolts and cable bolts,as well as innovative grouted rock bolts and cables characterized by their high pretension,strength,and sealing hole pressure.An examination of the merits and demerits of standard inorganic and organic grouting materials versus the new inorganic–organic composite materials,including their specific application conditions,was conducted.Additionally,the article presents various methods and instruments to assess the support effect of grouting rock bolts,cable bolts,and grouting reinforcement.Furthermore,it provides a foundation for understanding the factors influencing decisions on grouted bolting timing,the sequence of grouting,the pressure applied,the volume of grout used,and the strategic arrangement of grouted rock bolts and cable bolts.The application of the high pretensioned high-pressure splitting grouted bolting collaborative control technology in a typical kilometer-deep soft rock mine in China—the soft coal seam and soft rock roadway in the Kouzidong coal mine,Huainan coal mining area,was introduced.Finally,the existing problems in grouted bolting control technology for deep soft rock roadways are analyzed,and the future development trend of grouted bolting control technology is anticipated. 展开更多
关键词 deep coal mine soft rock roadway grouted bolting rock bolt and cable grouting material high-pressure splitting grouting collaborative control technology
下载PDF
Mechanical behavior and failure mechanisms of rock bolts subjected to static-dynamic loads
5
作者 Hongpu Kang Guiyang Yuan +4 位作者 Linpo Si Fuqiang Gao Jinfu Lou Jinghe Yang Shuangyong Dong 《International Journal of Mining Science and Technology》 SCIE EI CAS CSCD 2024年第3期281-288,共8页
This study explores the effects of dynamic and static loading on rock bolt performance a key factor in maintaining the structural safety of coal mine roadways susceptible to coal bursts.Employing a housemade load fram... This study explores the effects of dynamic and static loading on rock bolt performance a key factor in maintaining the structural safety of coal mine roadways susceptible to coal bursts.Employing a housemade load frame to simulate various failure scenarios,pretension-impact-pull tests on rock bolts were conducted to scrutinize their dynamic responses under varied static load conditions and their failure traits under combined loads.The experimental results denote that with increased impact energy,maximum and average impact loads on rock bolts escalate significantly under pretension,initiating plastic deformation beyond a certain threshold.Despite minor reductions in the yield load due to impactinduced damage,pretension aids in constraining post-impact deformation rate and fluctuation degree of rock bolts.Moreover,impact-induced plastic deformation causes internal microstructure dislocation,fortifying the stiffness of the rock bolt support system.The magnitude of this fortification is directly related to the plastic deformation induced by the impact.These findings provide crucial guidance for designing rock bolt support in coal mine roadway excavation,emphasizing the necessity to consider both static and dynamic loads for improved safety and efficiency. 展开更多
关键词 Rock bolt PRETENSION Static and dynamic load IMPACT
下载PDF
State-of-the-art on the anchorage performance of rock bolts subjected to shear load
6
作者 Yu Chen Haodong Xiao 《International Journal of Coal Science & Technology》 EI CAS CSCD 2024年第1期1-30,共30页
Rock bolts are extensively utilized in underground engineering as a means of offering support and stability to rock masses in tunnels,mines,and other underground structures.In environments of high ground stress,faults... Rock bolts are extensively utilized in underground engineering as a means of offering support and stability to rock masses in tunnels,mines,and other underground structures.In environments of high ground stress,faults or weak zones can frequently arise in rock formations,presenting a significant challenge for engineering and potentially leading to underground engineering collapse.Rock bolts serve as a crucial structural element for the transmission of tensile stress and are capable of withstanding shear loads to prevent sliding of weak zones within rock mass.Therefore,a complete understanding of the behavior of rock bolts subjected to shear loads is essential.This paper presents a state-of-the-art review of the research progress of rock bolts subjected to shear load in three categories:experiment,numerical simulation,and analytical model.The review focuses on the research studies and developments in this area since the 1970s,providing a comprehensive overview of numerous factors that influence the anchorage performance of rock bolts.These factors include the diameter and angle of the rock bolt installation,rock strength,grouting material,bolt material,borehole diameter,rock bolt preload,normal stress,joint surface roughness and joint expansion angle.The paper reviews the improvement of mechanical parameter setting in numerical simulation of rock bolt shear.Furthermore,it delves into the optimization of the analytical model concerning rock bolt shear theory,approached from the perspectives of both Elastic foundation beam theory coupled with Elastoplasticity theory and Structural mechanic methods.The significance of this review lies in its ability to provide insights into the mechanical behavior of rock bolts.The paper also highlights the limitations of current research and guidelines for further research of rock bolts. 展开更多
关键词 Rock bolt Shear load Shear test Numerical simulation Analytical model
下载PDF
Failure characterization of fully grouted rock bolts under triaxial testing
7
作者 Hadi Nourizadeh Ali Mirzaghorbanali +3 位作者 Mehdi Serati Elamin Mutaz Kevin McDougall Naj Aziz 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第3期778-789,共12页
Confining stresses serve as a pivotal determinant in shaping the behavior of grouted rock bolts.Nonetheless,prior investigations have oversimplified the three-dimensional stress state,primarily assuming hydrostatic st... Confining stresses serve as a pivotal determinant in shaping the behavior of grouted rock bolts.Nonetheless,prior investigations have oversimplified the three-dimensional stress state,primarily assuming hydrostatic stress conditions.Under these conditions,it is assumed that the intermediate principal stress(σ_(2))equals the minimum principal stress(σ_(3)).This assumption overlooks the potential variations in magnitudes of in situ stress conditions along all three directions near an underground opening where a rock bolt is installed.In this study,a series of push tests was meticulously conducted under triaxial conditions.These tests involved applying non-uniform confining stresses(σ_(2)≠σ_(3))to cubic specimens,aiming to unveil the previously overlooked influence of intermediate principal stresses on the strength properties of rock bolts.The results show that as the confining stresses increase from zero to higher levels,the pre-failure behavior changes from linear to nonlinear forms,resulting in an increase in initial stiffness from 2.08 kN/mm to 32.51 kN/mm.The load-displacement curves further illuminate distinct post-failure behavior at elevated levels of confining stresses,characterized by enhanced stiffness.Notably,the peak load capacity ranged from 27.9 kN to 46.5 kN as confining stresses advanced from σ_(2)=σ_(3)=0 to σ_(2)=20 MPa and σ_(3)=10 MPa.Additionally,the outcomes highlight an influence of confining stress on the lateral deformation of samples.Lower levels of confinement prompt overall dilation in lateral deformation,while higher confinements maintain a state of shrinkage.Furthermore,diverse failure modes have been identified,intricately tied to the arrangement of confining stresses.Lower confinements tend to induce a splitting mode of failure,whereas higher loads bring about a shift towards a pure interfacial shear-off and shear-crushed failure mechanism. 展开更多
关键词 Rock bolts bolt-grout interface Bond strength Push test Triaxial tests
下载PDF
Stability analysis of tunnel face reinforced with face bolts
8
作者 TIAN Chongming JIANG Yin +3 位作者 YE Fei OUYANG Aohui HAN Xingbo SONG Guifeng 《Journal of Mountain Science》 SCIE CSCD 2024年第7期2445-2461,共17页
Face bolting has been widely utilized to enhance the stability of tunnel face,particularly in soft soil tunnels.However,the influence of bolt reinforcement and its layout on tunnel face stability has not been systemat... Face bolting has been widely utilized to enhance the stability of tunnel face,particularly in soft soil tunnels.However,the influence of bolt reinforcement and its layout on tunnel face stability has not been systematically studied.Based on the theory of linear elastic mechanics,this study delved into the specific mechanisms of bolt reinforcement on the tunnel face in both horizontal and vertical dimensions.It also identified the primary failure types of bolts.Additionally,a design approach for tunnel face bolts that incorporates spatial layout was established using the limit equilibrium method to enhance the conventional wedge-prism model.The proposed model was subsequently validated through various means,and the specific influence of relevant bolt design parameters on tunnel face stability was analyzed.Furthermore,design principles for tunnel face bolts under different geological conditions were presented.The findings indicate that bolt failure can be categorized into three stages:tensile failure,pullout failure,and comprehensive failure.Increasing cohesion,internal friction angle,bolt density,and overlap length can effectively enhance tunnel face stability.Due to significant variations in stratum conditions,tailored design approaches based on specific failure stages are necessary for bolt design. 展开更多
关键词 Highway tunnels Tunnel face Face bolts Limit equilibrium method Slice method
下载PDF
Numerical simulation on bolted rock joint shearing performance 被引量:18
9
作者 SONG Hongwei DUAN Yanyan YANG Jing 《Mining Science and Technology》 EI CAS 2010年第3期460-465,共6页
A Double Shear Model(DSM) was used in a numerical simulation on bolted rock joint shearing performance.An entire bolt deformed as the letter'U'under a shear load between two joints.Near the bolt-joint intersec... A Double Shear Model(DSM) was used in a numerical simulation on bolted rock joint shearing performance.An entire bolt deformed as the letter'U'under a shear load between two joints.Near the bolt-joint intersection,the bolt partly deformed as the letter'Z'.There were two critical points along the bolt:one was at the bolt-joint intersection with zero bending moment and the other at the maximum bending moment(plastic hinge) with zero shear stress.The blocks on two sides slid along the bolt as it deformed. A separation area was found between the two joint contact surfaces of the middle rock block and sided block.This area of separation was related to bolt diameter and external forces.We assume that this area is related to the work of external forces.Further research is needed. 展开更多
关键词 bolt rock joint SHEAR numerical simulation
下载PDF
A global-local finite element analysis of hybrid composite-to-metal bolted connections used in aerospace engineering 被引量:1
10
作者 梁珂 《Journal of Central South University》 SCIE EI CAS CSCD 2017年第6期1225-1232,共8页
Efficient bolted joint design is an essential part of designing the minimum weight aerospace structures, since structural failures usually occur at connections and interface. A comprehensive numerical study of three-d... Efficient bolted joint design is an essential part of designing the minimum weight aerospace structures, since structural failures usually occur at connections and interface. A comprehensive numerical study of three-dimensional(3D) stress variations is prohibitively expensive for a large-scale structure where hundreds of bolts can be present. In this work, the hybrid composite-to-metal bolted connections used in the upper stage of European Ariane 5ME rocket are analyzed using the global-local finite element(FE) approach which involves an approximate analysis of the whole structure followed by a detailed analysis of a significantly smaller region of interest. We calculate the Tsai-Wu failure index and the margin of safety using the stresses obtained from ABAQUS. We find that the composite part of a hybrid bolted connection is prone to failure compared to the metal part. We determine the bolt preload based on the clamp-up load calculated using a maximum preload to make the composite part safe. We conclude that the unsuitable bolt preload may cause the failure of the composite part due to the high stress concentration in the vicinity of the bolt. The global-local analysis provides an efficient computational tool for enhancing 3D stress analysis in the highly loaded region. 展开更多
关键词 bolted connection global-local FINITE element approach failure bolt PRELOAD
下载PDF
Finite Element Modeling and Modal Analysis of Complicated Structure with Bolted Joints 被引量:3
11
作者 蒲大宇 廖日东 +1 位作者 左正兴 冯慧华 《Journal of Beijing Institute of Technology》 EI CAS 2009年第3期273-277,共5页
A contact bolt model is proposed as a new modeling technique to investigate the complex structure with bolted joints for modal analysis and compared with the coupled bolt model, and the test results are given. Among t... A contact bolt model is proposed as a new modeling technique to investigate the complex structure with bolted joints for modal analysis and compared with the coupled bolt model, and the test results are given. Among these models, the coupled bolt model provides the best accurate responses compared with the experimental results. The contact bolt model shows the best effectiveness and usefulness in view of operational time. The bolt models proposed in this study are adopted for a dynamic characteristic analysis of a large diesel engine consisting of several parts which are connected by many bolts. The dynamic behavior of the entire engine structure was investigated by experiment. The coupled bolt model and the contact bolt model were applied to model the assembly of engine with high preload. The experimental results are in good agreement with the finite element method (FEM) results. Compared with the other models, the contact bolt model presented in this paper is more effective and useful in view of operational time and experience of analysts. 展开更多
关键词 finite element method(FEM) bolted joints modal analysis internal combustion engine
下载PDF
Influence of Shim Layers on Progressive Failure of a Composite Componentin Composite-Aluminum Bolted Joint in Aerospace Structural Assembly 被引量:2
12
作者 Cephas Yaw Attahu An Luling +1 位作者 Li Zhaoqing Gao Guoqiang 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2018年第1期188-202,共15页
The influence of varying shim layers on the progressive damage/failure of a composite component in a bolted composite-aluminum aerospace structural assembly was investigated using a non-linear three-dimensional(3 D)st... The influence of varying shim layers on the progressive damage/failure of a composite component in a bolted composite-aluminum aerospace structural assembly was investigated using a non-linear three-dimensional(3 D)structural solid elements assembled model of a carbon fiber-reinforced polymer(CFRP)-aluminum single-lap joint with a titanium(Ti-6 Al-4 V)fastener and a washer generated with the commercial finite element(FE)software package,ABAQUS/Standard.A progressive failure algorithm written in Fortran code with a set of appropriate degradation rules was incorporated as a user subroutine in ABAQUS to simulate the non-linear damage behavior of the composite component in the composite-aluminum bolted aerospace structure.The assembled 3 DFE model simulated,as well as the specimen for the experimental testing consisted of a carbon-epoxy IMS-977-2 substrate,aluminum alloy 7075-T651 substrate,liquid shim(Hysol EA 9394),solid peelable fiberglass shim,a titanium fastener,and a washer.In distinction to previous investigations,the influence of shim layers(liquid shim and solid peelable fiberglass shim)inserted in-between the faying surfaces(CFRP and aluminum alloy substrates)were investigated by both numerical simulations and experimental work.The simulated model and test specimens conformed to the standard test configurations for both civil and military standards.The numerical simulations correlated well with the experimental results and it has been found that:(1)The shimming procedure as agreed upon by the aerospace industry for the resolution of assembly gaps in bolted joints for composite materials is the same for a composite-aluminum structure;liquid shim series(0.3,0.5 and 0.7 mm thicknesses)prolonged the service life of the composite component whereas a solid peelable fiberglass shim most definitely had a better influence on the 0.9 assembly gap compared with the liquid shim;(2)The shim layers considerably influenced the structural strength of the composite component by delaying its ultimate failure thereby increasing its service life;and(3)Increasing the shim layer′s thickness led to a significant corresponding effect on the stiffness but with minimal effect on the ultimate load. 展开更多
关键词 composite-aluminum progressive failure MODELING finite element MODELING single-lap bolted joint SHIMMING AEROSPACE structures
下载PDF
STRESS-STRAIN FINITE ELEMENT ANALYSIS AND FATIGUE LIFE PREDICTION FOR BOLTED CONNECTIONS 被引量:1
13
作者 Wang Ziqin Xie Qingsheng Mechanical Engineering Department,Guizhou University of Technology,Guiyang 550003,China 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2002年第1期75-78,共4页
A cyclic plasticity model is used into finite element (FE) method to obtainthe details of elastic-plastic stress-strain in the bolts under cyclic axial loading. Two criteriain multiaxial fatigue are employed to predic... A cyclic plasticity model is used into finite element (FE) method to obtainthe details of elastic-plastic stress-strain in the bolts under cyclic axial loading. Two criteriain multiaxial fatigue are employed to predict fatigue lives of bolts. The predicted fatigue livesare in favorable agreement with the experimental results for machined bolts. 展开更多
关键词 Finite element FATIGUE bolted connection
下载PDF
Experimental study on anti-penetration mechanism of bolted composite protective structure with limited span under impact of low-velocity projectile 被引量:3
14
作者 Yu-jia Liu Dian Li +2 位作者 Hai-liang Hou Zhu-jie Zhao Yue Xie 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2022年第6期995-1005,共11页
In order to study the influence of the bolt joint mode on low-velocity projectiles penetrating the composite protective structure,two bolt joint models which connect the composite target to the fixed frame were design... In order to study the influence of the bolt joint mode on low-velocity projectiles penetrating the composite protective structure,two bolt joint models which connect the composite target to the fixed frame were designed,the ballistic test of the bolted composite protective structure with limited span was carried out,and the bearing and failure characteristics of the bolted region,as well as the energy dissipation of each part of the structure,were analyzed.The results show that in the condition of lowvelocity impact,there are three failure modes for the bolted composite protective structure subjected to projectile penetration,including failure of the impact point of the composite target,failure of protective structure connecting components and failure of the holes in the bolted region of the composite target;the failure mode of bolt holes in the bolted region has a great influence on the protection performance,and the allowable value of the bearing capacity of the bolted region depends on the sum of the minimum failure load in the failure modes and the friction force;shear-out failure occurring in the bolt holes in the bolted region exerts the greatest effect on ballistic performance,which should be avoided;When simultaneous failure occurs in the bolted region and the free deformation region of the composite protective structure,the energy absorption per unit surface density of the composite protective structure reaches the maximum,which can give full play to its anti-penetration efficiency. 展开更多
关键词 Impact dynamics Composite protective structure bolt joint Ballistic test Failure modes
下载PDF
Bolt Design of Ceramic Matrix Composite and Superalloy Bolted Joint Based on Damage Failure Load 被引量:2
15
作者 Chao Lv Shuyuan Zhao +4 位作者 Zhengyu Li Zeliang Pu Jianglong Dong Xinyang Sun Wenjiao Zhang 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2021年第2期55-61,共7页
Ceramic matrix composite(CMC)and superalloy bolted joints are commonly used high temperature connection structures in aerospace and aeronautical fields.In this paper,a finite element model coupled with progressive dam... Ceramic matrix composite(CMC)and superalloy bolted joints are commonly used high temperature connection structures in aerospace and aeronautical fields.In this paper,a finite element model coupled with progressive damage analysis of 2D C/SiC composites and superalloy bolted joint was implemented to simulate the uniaxial tensile loading process by using the ABAQUS finite element software.The parametric effects of raised head bolt on stress distribution,tensile performance,and damage process were studied for the CMC⁃superalloy bolted joint structures.The results showed that the final failure load increased first to the maximum value,and then decreased with the rise of bolt diameter,bolt head diameter,and bolt head thickness,respectively.When the three parameters were 5.0 mm,9.5 mm,and 2.8 mm for the current studied bolt configuration,the joint structure gave the maximum load bearing capacity for the considered parameter ranges.It was also found that around 42%potential improvement in load bearing capacity could be achieved by very small adjustments in bolt parameters of the joints. 展开更多
关键词 2D C/SiC composite progressive damage analysis tensile properties bolted joint bolt parameters
下载PDF
Bearing Failure Optimization of Composite Double-Lap Bolted Joints Based on a Three-Step Strategy Marked By Feasible Region Reduction and Model Decoupling 被引量:1
16
作者 Fengrui Liu Wanting Yao +2 位作者 Xinhong Shi Libin Zhao Jianyu Zhang 《Computers, Materials & Continua》 SCIE EI 2020年第2期977-999,共23页
To minimize the mass and increase the bearing failure load of composite double-lap bolted joints,a three-step optimization strategy including feasible region reduction,optimization model decoupling and optimization wa... To minimize the mass and increase the bearing failure load of composite double-lap bolted joints,a three-step optimization strategy including feasible region reduction,optimization model decoupling and optimization was presented.In feasible region reduction,the dimensions of the feasible design region were reduced by selecting dominant design variables from numerous multilevel parameters by sensitivity analyses,and the feasible regions of variables were reduced by influence mechanism analyses.In model decoupling,the optimization model with a large number of variables was divided into various sub-models with fewer variables by variance analysis.In the third step,the optimization sub-models were solved one by one using a genetic algorithm,and the modified characteristic curve method was adopted as the failure prediction method.Based on the proposed optimization method,optimization of a double-lap single-bolt joint was performed using the ANSYS®code.The results show that the bearing failure load increased by 13.5%and that the mass decreased by 8.7%compared with those of the initial design of the joint,which validated the effectiveness of the three-step optimization strategy. 展开更多
关键词 COMPOSITE bolted joints sensitivity analysis OPTIMIZATION
下载PDF
Stress Analysis of Bolted Joints Part II. Contact and Slip Analysis of a Four Bolt Joint 被引量:1
17
作者 László Molnár Károly Váradi +1 位作者 János Holubán Andor Tamási 《Modern Mechanical Engineering》 2014年第1期46-55,共10页
For up-to-date bolted joints, first of all in vehicles, high strength bolts of 10.9 or even 12.9 are used, which are preloaded up to 90% or even 100% of the yield strength. The primary aim of this high degree utilizat... For up-to-date bolted joints, first of all in vehicles, high strength bolts of 10.9 or even 12.9 are used, which are preloaded up to 90% or even 100% of the yield strength. The primary aim of this high degree utilization is the weight reduction. For the analytic dimensioning of bolted joints, the VDI 2230 Richtlinien German standard [1] provides support. However, the analytic model can mostly consider the true structural characteristics only in a limited way. The analytic modeling is especially uncertain in case of multiple bolted joints when the load distribution among the bolts depends reasonably upon the elastic deformation of the participating elements in the joints over the geometry of the bolted joint. The first part of this paper deals with the problems of numerical modeling and stress analysis, respectively specifying the analytic dimensioning procedure by applying elastic or rather elastic-plastic material law. The error magnitude in bolted joint calculation was examined in case of omitting the existing threaded connection—between the bolt and the nut—in order to simplify the model. The second part of the paper deals with the dimensioning of stands and cantilevers’ multi-bolt fixing problems, first of all, with the load distribution among the bolts keeping in view the analysis of the local slipping relations. For demonstrating the above technique, an elaborated numeric procedure is presented for a four-bolted cantilever, having bolted joints pre-tightened to the yield strength. 展开更多
关键词 bolted JOINTS Numerical Modeling Stress ANALYSIS
下载PDF
Effect Mechanisms of Hygrothermal Environments on Failure of Single-Lap and Double-Lap CFRP-Aluminum Bolted Joints 被引量:1
18
作者 Meijuan Shan Libin Zhao +2 位作者 Wei Huang Fengrui Liu Jianyu Zhang 《Computer Modeling in Engineering & Sciences》 SCIE EI 2020年第4期101-127,共27页
The high demands for load-carrying capability and structural efficiency of composite-metal bolted joints trigger in-depth investigations on failure mechanisms of the joints in hygrothermal environments.However,few stu... The high demands for load-carrying capability and structural efficiency of composite-metal bolted joints trigger in-depth investigations on failure mechanisms of the joints in hygrothermal environments.However,few studies have been presented to exhaustively reveal hygrothermal effects on the failure of CFRP-metal bolted joints,which differ from CFRP-CFRP or metal-metal bolted joints because of the remarkably different material properties of CFRPs and metals.In this paper,hygrothermal effects on tensile failures of single-lap and double-lap CFRP-aluminum bolted joints were experimentally and numerically investigated.A novel numerical model,in which a hygrothermal-included progressive damage model of composites was established and elastic-plastic models of metals were built,was proposed to predict the failures of the CFRP-metal bolted joints in hygrothermal environments and validated by corresponding experiments.Different failure mechanisms of single-lap and double-lap CFRP-aluminum bolted joints,under 23°C/Dry and 70°C/Wet conditions,were revealed,respectively.It follows that both the collapse failures of the single-lap and double-lap bolted joints were dominated by the bearing failure of the CFRP hole laminate in the two conditions,indicating that the hygrothermal environment did not change the macro failure modes of the joints.However,the hygrothermal environment considerably shortened the damage propagation processes and reduced the strength of the joints.Besides,the hygrothermal environment weakened the load-transfer capability of the single-lap joint more severely than the double-lap joint because it aggravated the secondary bending effects of the single-lap joint obviously. 展开更多
关键词 CFRP-metal hybrid structure bolted joint hygrothermal environment effect mechanism numerical model
下载PDF
Analytical large deformation shear strength for bolted rough discontinuous rock 被引量:1
19
作者 刘波 陶龙光 岳中琦 《Journal of Coal Science & Engineering(China)》 2004年第1期24-28,共5页
Presented a new analytical model for studying the shear-tensile large deforma-tion behavior near the vicinity of joint interface for bolted rough discontinuous rock, and presented the formulation estimating global she... Presented a new analytical model for studying the shear-tensile large deforma-tion behavior near the vicinity of joint interface for bolted rough discontinuous rock, and presented the formulation estimating global shear strength for bolted joints under shear-ing-tensile loads. The analytical strength curves of bolts contribution on reinforced discon-tinuous rocks as the function of joint displacements or deformation angle of a bolt at rock joints was obtained. Based on Barton’s equation on JRC roughness profiles, the theoreti-cal shearing strength of bolted rough joints was also established. Test results on bolted granite and marble specimen confirm the validity of the analytical approach. 展开更多
关键词 bolt rough rock joints large strain deformation shear strength analytical model
下载PDF
Modal Experiments and Finite Element Analysis of the Bolted Structure Considering Interface Stiffness and Prtension 被引量:2
20
作者 WEI Li-dui DUAN Shu-lin WU Ji WU Qi-li XING Hui 《International Journal of Plant Engineering and Management》 2012年第2期87-94,共8页
It is particularly important to evaluate natural frequencies and natural modes of the structure of bolted joints to avoid the failures of the structure due to the resonance. The vibration characteristics of bolted str... It is particularly important to evaluate natural frequencies and natural modes of the structure of bolted joints to avoid the failures of the structure due to the resonance. The vibration characteristics of bolted structures are closely connected to surface roughness of contact interfaces, the magnitude of pretension of the bolts and the number of clamping bolts. In this paper, the effect of the factors above on the natural frequencies of bolted structures is sys- tematically investigated by experiments. Then, the finite element method is applied to analyze the effect. Finally, the numerical method is validated by experimental measurements of the natural frequencies. 展开更多
关键词 surface roughness PRETENSION natural frequency FEM bolted structures