To establish bonding stress—slip constitutive model between bars and grout concrete,13 test specimens were employed to study the bonding behavior and the force transfer of bars adhered to grout concrete. The bonding ...To establish bonding stress—slip constitutive model between bars and grout concrete,13 test specimens were employed to study the bonding behavior and the force transfer of bars adhered to grout concrete. The bonding stress development of bars adhered to grout concrete was analyzed. The local bonding stress—slip curve was obtained. Based on the test results,a new bonding stress— slip constitutive model between bars and grout concrete was proposed. The results show that the maximum bonding stress is not influenced by the bar bond length,but it is strengthened when the splitting strength of grout concrete is increased. The model matches the experimental results well,and the regressing coefficient equals 1.7.展开更多
A new analytical study on stresses around a post-tensioned anchor in rocks with two perpendicular joint sets is presented. The assumptions of orthotropic elastic rock with plane strain conditions are made in derivatio...A new analytical study on stresses around a post-tensioned anchor in rocks with two perpendicular joint sets is presented. The assumptions of orthotropic elastic rock with plane strain conditions are made in derivation of the formulations. A tri-linear bond-slip constitutive law is used for modeling the tendon-grout interface behavior and debonding of this interface. The bearing plate width is also considered in the analysis. The obtained solutions are in the integral forms and numerical techniques that have been used for evaluation. In the illustrative example given, the major principal stress is compressive in the anchor free zone and compressive stress concentrations of 815 k Pa and 727 k Pa(for the anchor load of 300 k N) are observed under the bearing plate and the bond length proximal end, respectively. However, large values of tensile stresses with the maximum of-434 k Pa are formed at the bond length distal end. The results obtained using the proposed solution are compared very those of numerical method(FEM).展开更多
The impact of fly ash content on bond performance of steel bars and their surrounding concrete is studied by means of sticking strain gauges on steel bars. The average bond stress-slip curves, the steel strain-anchor ...The impact of fly ash content on bond performance of steel bars and their surrounding concrete is studied by means of sticking strain gauges on steel bars. The average bond stress-slip curves, the steel strain-anchor location curves, and the bond stress-anchor position curves of the pullout specimens with various fly ash contents are obtained. Results indicate that the bond performance of concrete and steel bars can be improved and the distribution of steel strain along the anchorage length tends to be more uniform by adding fly ash in concrete specimens, and both ultimate bond stress and ultimate slip deformation increase the most when 20% of specimens′ content is fly ash.展开更多
-Based on the experimental data, a stress variation model of the bond stress-slip relationship between steel bar and concrete is established. The characteristic of the model is that the boundary conditions are satisfi...-Based on the experimental data, a stress variation model of the bond stress-slip relationship between steel bar and concrete is established. The characteristic of the model is that the boundary conditions are satisfied very well; the effects of the material properties, the concrete cover, the crack spacing and the distance from the cracked cross section are considered. Good agreement between measured and calculated bond stress-slip relationship is found. This model is useful for the study of the stiffness, deformation and crack width of reinforced concrete members, and for the nonlinear analysis of reinforced concrete structures by the finite element method.展开更多
This study investigates the bond between seawater scoria aggregate concrete(SSAC)and stainless reinforcement(SR)through a series of pull-out tests.A total of 39 specimens,considering five experimental parameters—con-...This study investigates the bond between seawater scoria aggregate concrete(SSAC)and stainless reinforcement(SR)through a series of pull-out tests.A total of 39 specimens,considering five experimental parameters—con-crete type(SSAC,ordinary concrete(OC)and seawater coral aggregate concrete(SCAC)),reinforcement type(SR,ordinary reinforcement(OR)),bond length(3,5 and 8 times bar diameter),concrete strength(C25 and C30)and concrete cover thickness(42 and 67 mm)—were prepared.The typical bond properties(failure pattern,bond strength,bond-slip curves and bond stress distribution,etc.)of seawater scoria aggregate concrete-stainless rein-forcement(SSAC-SR)specimen were systematically studied.Generally,the failure pattern changed with the con-crete type used,and the failure surface of SSAC specimen was different from that of OC specimen.SSAC enhanced the bond strength of specimen,while its effect on the deformation of SSAC-SR was negative.On aver-age,the peak slip of SSAC specimens was 20%lower while the bond strength was 6.7%higher compared to OC specimens under the similar conditions.The effects of variables on the bond strength of SSAC–SR in increasing order are concrete type,bond length,concrete strength and cover thickness.The bond-slip curve of SSAC-SR specimen consisted of micro-slipping,slipping and declining stages.It can be obtained that SSAC reduced the curve curvature of bond-slip,and the decline of curve became steep after adopting SR.The typical distribution of bond stress along bond length changed with the types of concrete and reinforcement used.Finally,a specific expression of the bond stress-slip curve considering the effects of various variables was established,which could provide a basis for the practical application of reinforced SSAC.展开更多
The shear bond of interface between concrete and basalt fiber reinforced polymer(BFRP)bars during freeze–thaw(F–T)cycles is crucial for the application of BFRP bar-reinforced concrete structures in cold regions.In t...The shear bond of interface between concrete and basalt fiber reinforced polymer(BFRP)bars during freeze–thaw(F–T)cycles is crucial for the application of BFRP bar-reinforced concrete structures in cold regions.In this study,48 groups of pull-out specimens were designed to test the shear bond of the BFRP-concrete interface subjected to F–T cycles.The effects of concrete strength,diameter,and embedment length of BFRP rebar were investigated under numerous F–T cycles.Test results showed that a larger diameter or longer embedment length of BFRP rebar resulted in lower interfacial shear bond behavior,such as interfacial bond strength,initial stiffness,and energy absorption,after the interface goes through F–T cycles.However,higher concrete strength and fewer F–T cycles were beneficial for enhancing the interfacial bond behavior.Subsequently,a three-dimensional(3D)interfacial model based on the finite element method was developed,and the interfacial bond behavior of the specimens was analyzed in-depth.Finally,a degradation bond strength subjected to F–T cycles was predicted by a proposed mechanical model.The predictions were fully consistent with the tested results.The model demonstrated accuracy in describing the shear bond behavior of the interface under numerous F–T cycles.展开更多
基金Project(2006BAJ03A01-05) supported by National Science and Technology Pillar Program during the 11th Five-Year Plan Period of ChinaProject (JG200705) supported by Key Laboratory of Structural Engineering of Shenyang Jianzhu University, China
文摘To establish bonding stress—slip constitutive model between bars and grout concrete,13 test specimens were employed to study the bonding behavior and the force transfer of bars adhered to grout concrete. The bonding stress development of bars adhered to grout concrete was analyzed. The local bonding stress—slip curve was obtained. Based on the test results,a new bonding stress— slip constitutive model between bars and grout concrete was proposed. The results show that the maximum bonding stress is not influenced by the bar bond length,but it is strengthened when the splitting strength of grout concrete is increased. The model matches the experimental results well,and the regressing coefficient equals 1.7.
文摘A new analytical study on stresses around a post-tensioned anchor in rocks with two perpendicular joint sets is presented. The assumptions of orthotropic elastic rock with plane strain conditions are made in derivation of the formulations. A tri-linear bond-slip constitutive law is used for modeling the tendon-grout interface behavior and debonding of this interface. The bearing plate width is also considered in the analysis. The obtained solutions are in the integral forms and numerical techniques that have been used for evaluation. In the illustrative example given, the major principal stress is compressive in the anchor free zone and compressive stress concentrations of 815 k Pa and 727 k Pa(for the anchor load of 300 k N) are observed under the bearing plate and the bond length proximal end, respectively. However, large values of tensile stresses with the maximum of-434 k Pa are formed at the bond length distal end. The results obtained using the proposed solution are compared very those of numerical method(FEM).
基金Supported by the Program of Excellent Talents in Six Fields of Jiangsu Province(2008183)~~
文摘The impact of fly ash content on bond performance of steel bars and their surrounding concrete is studied by means of sticking strain gauges on steel bars. The average bond stress-slip curves, the steel strain-anchor location curves, and the bond stress-anchor position curves of the pullout specimens with various fly ash contents are obtained. Results indicate that the bond performance of concrete and steel bars can be improved and the distribution of steel strain along the anchorage length tends to be more uniform by adding fly ash in concrete specimens, and both ultimate bond stress and ultimate slip deformation increase the most when 20% of specimens′ content is fly ash.
文摘-Based on the experimental data, a stress variation model of the bond stress-slip relationship between steel bar and concrete is established. The characteristic of the model is that the boundary conditions are satisfied very well; the effects of the material properties, the concrete cover, the crack spacing and the distance from the cracked cross section are considered. Good agreement between measured and calculated bond stress-slip relationship is found. This model is useful for the study of the stiffness, deformation and crack width of reinforced concrete members, and for the nonlinear analysis of reinforced concrete structures by the finite element method.
基金funded by the National Natural Science Foundation of China(Nos.51408346,51978389)the Systematic Project of Guangxi Key Laboratory of Disaster Prevention and Structural Safety(2019ZDK035)the Opening Foundation of Shandong Key Laboratory of Civil Engineering Disaster Prevention and Mitigation(No.CDPM2019KF12).
文摘This study investigates the bond between seawater scoria aggregate concrete(SSAC)and stainless reinforcement(SR)through a series of pull-out tests.A total of 39 specimens,considering five experimental parameters—con-crete type(SSAC,ordinary concrete(OC)and seawater coral aggregate concrete(SCAC)),reinforcement type(SR,ordinary reinforcement(OR)),bond length(3,5 and 8 times bar diameter),concrete strength(C25 and C30)and concrete cover thickness(42 and 67 mm)—were prepared.The typical bond properties(failure pattern,bond strength,bond-slip curves and bond stress distribution,etc.)of seawater scoria aggregate concrete-stainless rein-forcement(SSAC-SR)specimen were systematically studied.Generally,the failure pattern changed with the con-crete type used,and the failure surface of SSAC specimen was different from that of OC specimen.SSAC enhanced the bond strength of specimen,while its effect on the deformation of SSAC-SR was negative.On aver-age,the peak slip of SSAC specimens was 20%lower while the bond strength was 6.7%higher compared to OC specimens under the similar conditions.The effects of variables on the bond strength of SSAC–SR in increasing order are concrete type,bond length,concrete strength and cover thickness.The bond-slip curve of SSAC-SR specimen consisted of micro-slipping,slipping and declining stages.It can be obtained that SSAC reduced the curve curvature of bond-slip,and the decline of curve became steep after adopting SR.The typical distribution of bond stress along bond length changed with the types of concrete and reinforcement used.Finally,a specific expression of the bond stress-slip curve considering the effects of various variables was established,which could provide a basis for the practical application of reinforced SSAC.
基金The authors acknowledge the financial support from the Key Laboratory of Performance Evolution and Control for Engineering Structures of the Ministry of Education of China(No.2019KF-4)the National Key Research Program of China(No.2021YFC1909901).
文摘The shear bond of interface between concrete and basalt fiber reinforced polymer(BFRP)bars during freeze–thaw(F–T)cycles is crucial for the application of BFRP bar-reinforced concrete structures in cold regions.In this study,48 groups of pull-out specimens were designed to test the shear bond of the BFRP-concrete interface subjected to F–T cycles.The effects of concrete strength,diameter,and embedment length of BFRP rebar were investigated under numerous F–T cycles.Test results showed that a larger diameter or longer embedment length of BFRP rebar resulted in lower interfacial shear bond behavior,such as interfacial bond strength,initial stiffness,and energy absorption,after the interface goes through F–T cycles.However,higher concrete strength and fewer F–T cycles were beneficial for enhancing the interfacial bond behavior.Subsequently,a three-dimensional(3D)interfacial model based on the finite element method was developed,and the interfacial bond behavior of the specimens was analyzed in-depth.Finally,a degradation bond strength subjected to F–T cycles was predicted by a proposed mechanical model.The predictions were fully consistent with the tested results.The model demonstrated accuracy in describing the shear bond behavior of the interface under numerous F–T cycles.