Accurate estimates of ductility demands on buckling-restrained braced frames(BRBFs)are crucial to performance-based design of BRBFs.An analytical study on the seismic behavior of BRBFs has been conducted at the ATLSS ...Accurate estimates of ductility demands on buckling-restrained braced frames(BRBFs)are crucial to performance-based design of BRBFs.An analytical study on the seismic behavior of BRBFs has been conducted at the ATLSS Center,Lehigh University to prepare for an upcoming experimental program.The analysis program DRAIN-2DX was used to model a one-bay,four-story prototype BRBF including material and geometric nonlinearities.The buckling- restrained brace(BRB)model incorporates both isotropic and kinematic hardening.Nonlinear static pushover and time- history analyses were performed on the prototype BRBF.Performance objectives for the BRBs were defined and used to evaluate the time-history analysis results.Particular emphasis was placed on global ductility demands and ductility demands on the BRBs.These demands were compared with anticipated ductility capacities.The analysis results,along with results from similar previous studies,are used to evaluate the BRBF design provisions that have been recommended for codification in the United States.The results show that BRB maximum ductility demands can be as high as 20 to 25.These demands significantly exceed those anticipated by the BRBF recommended provisions.Results from the static pushover and time- history analyses are used to demonstrate why the ductility demands exceed those anticipated by the recommended provisions. The BRB qualification testing protocol contained in the BRBF recommended provisions is shown to be inadequate because it requires only a maximum ductility demand of at most 7.5.Modifications to the testing protocol are recommended.展开更多
This paper describes shaking table tests of a 1:12 scale model of a special concentrically braced steel frame with pinned connections, which was fabricated according to a one-bay braced frame selected from a typical ...This paper describes shaking table tests of a 1:12 scale model of a special concentrically braced steel frame with pinned connections, which was fabricated according to a one-bay braced frame selected from a typical main factory building of a large thermal power plant. In order to investigate the seismic performance of this type of structure, several ground motion accelerations with different levels for seismic intensity Ⅷ, based on the Chinese Code for Seismic Design of Buildings, were selected to excite the model. The results show that the design methods of the members and the connections are adequate and that the structural system will perform well in regions of high seismicity. In addition to the tests, numerical simulations were also conducted and the results showed good agreement with the test results. Thus, the numerical model is shown to be accurate and the beam element can be used to model this structural system.展开更多
A 15-storey K-braced reinforced concrete model frame with irregular columns, i.e., T-shaped, L-shaped, as well as +-shaped columns, was constructed and tested on the six-degree-of-freedom shaking table at the State K...A 15-storey K-braced reinforced concrete model frame with irregular columns, i.e., T-shaped, L-shaped, as well as +-shaped columns, was constructed and tested on the six-degree-of-freedom shaking table at the State Key Laboratory for Disaster Reduction in Civil Engineering in Tongji, China. Two types of earthquake records, El-Centro wave (south-north direction) and Shanghai artificial wave (SHAW) with various peak accelerations and principal-secondary sequences, were input and experimentally studied. Based on the shaking table tests and theoretical analysis, several observations can be made. The failure sequence of the model structure is brace→beam→column→joints, so that the design philosophy for several lines of defense has been achieved. Earthquake waves with different spectrums not only influence the magnitude and distribution of the earthquake force and the storey shear force, but also obviously affect the magnitude of the displacement response. The aftershock seismic response of previously damaged reinforced concrete braced frames with irregular columns possesses the equivalent elastic performance characteristic. Generally speaking, from the aspects of failure features and drift ratio, this type of reinforced concrete structure provides adequate earthquake resistance and can be promoted for use in China.展开更多
Performance-based seismic design(PBSD) aims to assess structures at different damage states. Since damage can be directly associated to displacements, seismic design with consideration of displacement seems to be logi...Performance-based seismic design(PBSD) aims to assess structures at different damage states. Since damage can be directly associated to displacements, seismic design with consideration of displacement seems to be logical. In this study, simple formulae to estimate the peak floor displacement patterns of eccentrically braced frames(EBFs) at different performance levels subjected to earthquake ground motions are proposed. These formulae are applicable in a PBSD and especially in direct displacement-based design(DDBD). Parametric study is conducted on a group of 30 EBFs under a set of 15 far field and near field accelerograms which they scaled to different amplitudes to adapt various performance levels. The results of thousands of nonlinear dynamic analyses of EBFs have been post-processed by nonlinear regression analysis in order to recognize the major parameters that influence the peak displacement pattern of these frames. Results show that suggested displacement patterns have relatively good agreement with those acquired by an exact nonlinear dynamic analysis.展开更多
A controlled rocking concentrically steel braced frame(CR-CSBF)is introduced as an alternative to conventional methods to prevent major structural damage during large earthquakes.It is equipped with elastic post-tensi...A controlled rocking concentrically steel braced frame(CR-CSBF)is introduced as an alternative to conventional methods to prevent major structural damage during large earthquakes.It is equipped with elastic post-tensioned(PT)cables and replaceable devices or fuses to provide overturning resistance and dissipate energy,respectively.Although CR-CSBFs are not officially legalized in globally valid codes for new buildings,it is expected to be presented in them in the near future.The main goal of this study is to determine the optimal design parameters consist of the yield strength and modulus of elasticity of the fuse,the initial force of the PT cable,and the gravity load on the rocking column,considering different heights of the frame,spanning ratios and ground motion types for dual-configuration CR-CSBF.Nonlinear time-history analyses are performed in OpenSees.This study aims to define the optimal input variables as effective design parameters of CR-CSBFs by comparing four seismic responses consisting of story drift,roof displacement,roof acceleration and base shear,and also using the Euclidean metric optimization method.Despite the previous research,this study is innovative and first of its kind.The results demonstrate that the optimal design parameters are variable for various conditions.展开更多
A satisfactory ductile performance of moment-resisting reinforced concrete concentric braced frame structures (RC-MRCBFs) is not warranted by only following the provisions proposed in Mexico’s Federal District Code (...A satisfactory ductile performance of moment-resisting reinforced concrete concentric braced frame structures (RC-MRCBFs) is not warranted by only following the provisions proposed in Mexico’s Federal District Code (MFDC-04). The nonlinear behavior of low to medium rise ductile RC-MRCBFs using steel X-bracing susceptible to buckling is evaluated in this study. The height of the studied structures ranges from 4 to 20 stories and they were located for design in the lakebed zone of Mexico City. The design of RC-MRCBFs was carried out considering variable contribution of the two main lines of defense of the dual system (RC columns and steel braces). In order to observe the principal elements responsible for dissipating the earthquake input energy, yielding mappings for diff erent load-steps were obtained using both nonlinear static and dynamic analyses. Some design parameters currently proposed in MFDC-04 as global ductility capacities, overstrength reduction factors and story drifts corresponding to diff erent limit states were assessed as a function of both the considered shear strength and slenderness ratios for the studied RC-MRCBFs using pushover analyses. Additionally, envelopes of response maxima of dynamic parameters were obtained from the story and global hysteresis curves. Finally, a brief discussion regarding residual drifts, residual drift ratios, mappings of residual deformations in steel braces and residual rotations in RC beams and columns is presented. From the analysis of the obtained results, it is concluded that when a suitable design criterion is considered, good structural behavior of RC-MRCBFs with steel-X bracing can be obtained. It is also observed that the shear strength balance has an impact in the height-wise distribution of residual drifts, and an important “shake-down” eff ect is obtained for all cases. There is a need to improve design parameters currently proposed in MFDC to promote an adequate seismic performance of RC-MRCBFs.展开更多
In present paper application of Endurance Time Analysis (ETA) method in nonlinear seismic assessment of steel concentrically braced frames is studied. In this method structure is subjected to a set of predesigned in...In present paper application of Endurance Time Analysis (ETA) method in nonlinear seismic assessment of steel concentrically braced frames is studied. In this method structure is subjected to a set of predesigned increasing acceleration functions and various responses of the structure are recorded during synthetic seismic excitation. The averages of maximum values for various responses in Nonlinear Time-History Analyses (NTHA) extracted from real ground motions are expected to be close to those obtained from ETA up to equivalent target time. For this purpose a set of 9, 11, 13 and 15 stories steel frames were designed and plastic hinge method was selected as source of nonlinearity in all cases. Responses were compared based on interstory drift ratio and story shear in two methods and results show satisfactory consistency between two methods. Finally, it was concluded that the ETA method can be used as alternative method in nonlinear seismic analysis of concentrically braced steel frames.展开更多
The object of this study is to determine the seismic response of regular high-rise steel buildings with chevron-braced frames. Mechanics models of three buildings of 14, 18 and 20 stories are studied, all of them with...The object of this study is to determine the seismic response of regular high-rise steel buildings with chevron-braced frames. Mechanics models of three buildings of 14, 18 and 20 stories are studied, all of them with similar geometric characteristics in plant and elevation. These models are realized using prescriptions and parameters from venezuelan design codes. The seismic action is carry on through varius synthetic design spectrum compatible accelerograms defined by the seismic codes in this study, with three levels of intensity corresponding to three specific Limit States. Dynamic analysis is used to compute parameters of ductility, over strength and maximum displacements. From these results it can be concluded that chevron-braced frames presented a good overall performance and non V-braced frames show greater damage due to dynamic actions, validating non linear dynamic analysis as a very powerful tool to seismic-resistance design and chevron-braced frames as a very useful choice in improving the response of tall steel structures. since this lateral bracing system is absent from Venezuelan seismic codes.展开更多
This paper presents a new type of structural bracing intended for seismic retrofitting use in framed structures. This special composite brace, termed glass-fiber-reinforced-polymer (GFRP)-tube-confined-concrete comp...This paper presents a new type of structural bracing intended for seismic retrofitting use in framed structures. This special composite brace, termed glass-fiber-reinforced-polymer (GFRP)-tube-confined-concrete composite brace, is comprised of concrete confined by a GFRP tube and an inner steel core for energy dissipation. Together with a contribution from the GFRP-tube confined concrete, the composite brace shows a substantially increased stiffness to control story drift, which is often a preferred feature in seismic retrofitting. An analysis model is established and implemented in a general finite element analysis program - OpenSees, for simulating the load-displacement behavior of the composite brace. Using this model, a parametric study of the hysteretic behavior (energy dissipation, stiffness, ductility and strength) of the composite brace was conducted under static cyclic loading and it was found that the area ratio of steel core to concrete has the greatest influence among all the parameters considered. To demonstrate the application of the composite brace in seismic retrofitting, a three-story nonductile reinforced concrete (RC) frame structure was retrofitted with the composite braces. Pushover analysis and nonlinear time-history analyses of the retrofitted RC frame structure was performed by employing a suite of 20 strong ground motion earthquake records. The analysis results show that the composite braces can effectively reduce the peak seismic responses of the RC frame structure without significantly increasing the base shear demand.展开更多
To improve wind resistance capacity of cable-braced steel portal frames,a double-braced portal frame was proposed by adding two pre-stressed knee braces to a cable-braced portal frame. To study the reasonable range of...To improve wind resistance capacity of cable-braced steel portal frames,a double-braced portal frame was proposed by adding two pre-stressed knee braces to a cable-braced portal frame. To study the reasonable range of application and method of cable parameter determination for this novel structure,the influences of load condition, span, base constraint, and cable parameters on structural performance were investigated by using the finite element code SAP2000. The results show that pre-stressed knee braces can effectively resist both uplifted and lateral wind loads,so this cablestayed and knee-braced steel portal frame is suitable for large wind.When the vertical load is comparable with the wind load,this novel type of portal frames is suitable for a medium span( 21-48 m). The cables in the cable brace can be determined by structural vertical stiffness,and the cables in the knee brace can be designed as the same as those in the cable-stayed part for the reason that their cross sectional area has only a weak effect on the structure. If no cable fails,the pretension variation of the cable does not affect the stiffness of the portal frame. The cable in the cable brace,working together with the cables in the knee braces,can ease uneven distribution of internal force,and their pretensions can be determined according to actual engineering projects.展开更多
文摘Accurate estimates of ductility demands on buckling-restrained braced frames(BRBFs)are crucial to performance-based design of BRBFs.An analytical study on the seismic behavior of BRBFs has been conducted at the ATLSS Center,Lehigh University to prepare for an upcoming experimental program.The analysis program DRAIN-2DX was used to model a one-bay,four-story prototype BRBF including material and geometric nonlinearities.The buckling- restrained brace(BRB)model incorporates both isotropic and kinematic hardening.Nonlinear static pushover and time- history analyses were performed on the prototype BRBF.Performance objectives for the BRBs were defined and used to evaluate the time-history analysis results.Particular emphasis was placed on global ductility demands and ductility demands on the BRBs.These demands were compared with anticipated ductility capacities.The analysis results,along with results from similar previous studies,are used to evaluate the BRBF design provisions that have been recommended for codification in the United States.The results show that BRB maximum ductility demands can be as high as 20 to 25.These demands significantly exceed those anticipated by the BRBF recommended provisions.Results from the static pushover and time- history analyses are used to demonstrate why the ductility demands exceed those anticipated by the recommended provisions. The BRB qualification testing protocol contained in the BRBF recommended provisions is shown to be inadequate because it requires only a maximum ductility demand of at most 7.5.Modifications to the testing protocol are recommended.
基金Northeast Electric Power Design Institute of China Under Grant No.K07-T716
文摘This paper describes shaking table tests of a 1:12 scale model of a special concentrically braced steel frame with pinned connections, which was fabricated according to a one-bay braced frame selected from a typical main factory building of a large thermal power plant. In order to investigate the seismic performance of this type of structure, several ground motion accelerations with different levels for seismic intensity Ⅷ, based on the Chinese Code for Seismic Design of Buildings, were selected to excite the model. The results show that the design methods of the members and the connections are adequate and that the structural system will perform well in regions of high seismicity. In addition to the tests, numerical simulations were also conducted and the results showed good agreement with the test results. Thus, the numerical model is shown to be accurate and the beam element can be used to model this structural system.
文摘A 15-storey K-braced reinforced concrete model frame with irregular columns, i.e., T-shaped, L-shaped, as well as +-shaped columns, was constructed and tested on the six-degree-of-freedom shaking table at the State Key Laboratory for Disaster Reduction in Civil Engineering in Tongji, China. Two types of earthquake records, El-Centro wave (south-north direction) and Shanghai artificial wave (SHAW) with various peak accelerations and principal-secondary sequences, were input and experimentally studied. Based on the shaking table tests and theoretical analysis, several observations can be made. The failure sequence of the model structure is brace→beam→column→joints, so that the design philosophy for several lines of defense has been achieved. Earthquake waves with different spectrums not only influence the magnitude and distribution of the earthquake force and the storey shear force, but also obviously affect the magnitude of the displacement response. The aftershock seismic response of previously damaged reinforced concrete braced frames with irregular columns possesses the equivalent elastic performance characteristic. Generally speaking, from the aspects of failure features and drift ratio, this type of reinforced concrete structure provides adequate earthquake resistance and can be promoted for use in China.
文摘Performance-based seismic design(PBSD) aims to assess structures at different damage states. Since damage can be directly associated to displacements, seismic design with consideration of displacement seems to be logical. In this study, simple formulae to estimate the peak floor displacement patterns of eccentrically braced frames(EBFs) at different performance levels subjected to earthquake ground motions are proposed. These formulae are applicable in a PBSD and especially in direct displacement-based design(DDBD). Parametric study is conducted on a group of 30 EBFs under a set of 15 far field and near field accelerograms which they scaled to different amplitudes to adapt various performance levels. The results of thousands of nonlinear dynamic analyses of EBFs have been post-processed by nonlinear regression analysis in order to recognize the major parameters that influence the peak displacement pattern of these frames. Results show that suggested displacement patterns have relatively good agreement with those acquired by an exact nonlinear dynamic analysis.
文摘A controlled rocking concentrically steel braced frame(CR-CSBF)is introduced as an alternative to conventional methods to prevent major structural damage during large earthquakes.It is equipped with elastic post-tensioned(PT)cables and replaceable devices or fuses to provide overturning resistance and dissipate energy,respectively.Although CR-CSBFs are not officially legalized in globally valid codes for new buildings,it is expected to be presented in them in the near future.The main goal of this study is to determine the optimal design parameters consist of the yield strength and modulus of elasticity of the fuse,the initial force of the PT cable,and the gravity load on the rocking column,considering different heights of the frame,spanning ratios and ground motion types for dual-configuration CR-CSBF.Nonlinear time-history analyses are performed in OpenSees.This study aims to define the optimal input variables as effective design parameters of CR-CSBFs by comparing four seismic responses consisting of story drift,roof displacement,roof acceleration and base shear,and also using the Euclidean metric optimization method.Despite the previous research,this study is innovative and first of its kind.The results demonstrate that the optimal design parameters are variable for various conditions.
基金National Science and Technology Council of Mexico (Conacyt)
文摘A satisfactory ductile performance of moment-resisting reinforced concrete concentric braced frame structures (RC-MRCBFs) is not warranted by only following the provisions proposed in Mexico’s Federal District Code (MFDC-04). The nonlinear behavior of low to medium rise ductile RC-MRCBFs using steel X-bracing susceptible to buckling is evaluated in this study. The height of the studied structures ranges from 4 to 20 stories and they were located for design in the lakebed zone of Mexico City. The design of RC-MRCBFs was carried out considering variable contribution of the two main lines of defense of the dual system (RC columns and steel braces). In order to observe the principal elements responsible for dissipating the earthquake input energy, yielding mappings for diff erent load-steps were obtained using both nonlinear static and dynamic analyses. Some design parameters currently proposed in MFDC-04 as global ductility capacities, overstrength reduction factors and story drifts corresponding to diff erent limit states were assessed as a function of both the considered shear strength and slenderness ratios for the studied RC-MRCBFs using pushover analyses. Additionally, envelopes of response maxima of dynamic parameters were obtained from the story and global hysteresis curves. Finally, a brief discussion regarding residual drifts, residual drift ratios, mappings of residual deformations in steel braces and residual rotations in RC beams and columns is presented. From the analysis of the obtained results, it is concluded that when a suitable design criterion is considered, good structural behavior of RC-MRCBFs with steel-X bracing can be obtained. It is also observed that the shear strength balance has an impact in the height-wise distribution of residual drifts, and an important “shake-down” eff ect is obtained for all cases. There is a need to improve design parameters currently proposed in MFDC to promote an adequate seismic performance of RC-MRCBFs.
文摘In present paper application of Endurance Time Analysis (ETA) method in nonlinear seismic assessment of steel concentrically braced frames is studied. In this method structure is subjected to a set of predesigned increasing acceleration functions and various responses of the structure are recorded during synthetic seismic excitation. The averages of maximum values for various responses in Nonlinear Time-History Analyses (NTHA) extracted from real ground motions are expected to be close to those obtained from ETA up to equivalent target time. For this purpose a set of 9, 11, 13 and 15 stories steel frames were designed and plastic hinge method was selected as source of nonlinearity in all cases. Responses were compared based on interstory drift ratio and story shear in two methods and results show satisfactory consistency between two methods. Finally, it was concluded that the ETA method can be used as alternative method in nonlinear seismic analysis of concentrically braced steel frames.
文摘The object of this study is to determine the seismic response of regular high-rise steel buildings with chevron-braced frames. Mechanics models of three buildings of 14, 18 and 20 stories are studied, all of them with similar geometric characteristics in plant and elevation. These models are realized using prescriptions and parameters from venezuelan design codes. The seismic action is carry on through varius synthetic design spectrum compatible accelerograms defined by the seismic codes in this study, with three levels of intensity corresponding to three specific Limit States. Dynamic analysis is used to compute parameters of ductility, over strength and maximum displacements. From these results it can be concluded that chevron-braced frames presented a good overall performance and non V-braced frames show greater damage due to dynamic actions, validating non linear dynamic analysis as a very powerful tool to seismic-resistance design and chevron-braced frames as a very useful choice in improving the response of tall steel structures. since this lateral bracing system is absent from Venezuelan seismic codes.
文摘This paper presents a new type of structural bracing intended for seismic retrofitting use in framed structures. This special composite brace, termed glass-fiber-reinforced-polymer (GFRP)-tube-confined-concrete composite brace, is comprised of concrete confined by a GFRP tube and an inner steel core for energy dissipation. Together with a contribution from the GFRP-tube confined concrete, the composite brace shows a substantially increased stiffness to control story drift, which is often a preferred feature in seismic retrofitting. An analysis model is established and implemented in a general finite element analysis program - OpenSees, for simulating the load-displacement behavior of the composite brace. Using this model, a parametric study of the hysteretic behavior (energy dissipation, stiffness, ductility and strength) of the composite brace was conducted under static cyclic loading and it was found that the area ratio of steel core to concrete has the greatest influence among all the parameters considered. To demonstrate the application of the composite brace in seismic retrofitting, a three-story nonductile reinforced concrete (RC) frame structure was retrofitted with the composite braces. Pushover analysis and nonlinear time-history analyses of the retrofitted RC frame structure was performed by employing a suite of 20 strong ground motion earthquake records. The analysis results show that the composite braces can effectively reduce the peak seismic responses of the RC frame structure without significantly increasing the base shear demand.
基金Fund of Jiangsu Province Key Laboratory of Structure Engineering,China(No.ZD1302)
文摘To improve wind resistance capacity of cable-braced steel portal frames,a double-braced portal frame was proposed by adding two pre-stressed knee braces to a cable-braced portal frame. To study the reasonable range of application and method of cable parameter determination for this novel structure,the influences of load condition, span, base constraint, and cable parameters on structural performance were investigated by using the finite element code SAP2000. The results show that pre-stressed knee braces can effectively resist both uplifted and lateral wind loads,so this cablestayed and knee-braced steel portal frame is suitable for large wind.When the vertical load is comparable with the wind load,this novel type of portal frames is suitable for a medium span( 21-48 m). The cables in the cable brace can be determined by structural vertical stiffness,and the cables in the knee brace can be designed as the same as those in the cable-stayed part for the reason that their cross sectional area has only a weak effect on the structure. If no cable fails,the pretension variation of the cable does not affect the stiffness of the portal frame. The cable in the cable brace,working together with the cables in the knee braces,can ease uneven distribution of internal force,and their pretensions can be determined according to actual engineering projects.