The modular multilevel matrix converter(M3C)is a potential frequency converter for low-frequency AC transmission.However,capacitor voltage control of high-voltage and largecapacity M3C is more difficult,especially for...The modular multilevel matrix converter(M3C)is a potential frequency converter for low-frequency AC transmission.However,capacitor voltage control of high-voltage and largecapacity M3C is more difficult,especially for voltage balancing between branches.To solve this problem,this paper defines sequence circulating components and theoretically analyzes the influence mechanism of different sequence circulating components on branch capacitor voltage.A fully decoupled branch energy balancing control method based on four groups of sequence circulating components is proposed.This method can control capacitor voltages of nine branches in horizontal,vertical and diagonal directions.Considering influences of both circulating current and voltage,a cross decoupled control is designed to improve control precision.Simulation results are taken from a low-frequency transmission system based on PSCAD/EMTDC,and effectiveness and precision of the proposed branch energy balancing control method are verified in the case of nonuniform parameters and an unbalanced power system.展开更多
A potential energy framework for assessment of grid vulnerability was presented.In the framework,the branch potential energy function model was constructed.Two indexes,current vulnerability and forecasting vulnerabili...A potential energy framework for assessment of grid vulnerability was presented.In the framework,the branch potential energy function model was constructed.Two indexes,current vulnerability and forecasting vulnerability,were calculated.The current vulnerability was used to identify the current vulnerable area through calculating the distance between the current transmitted power and initial transmitted power;and the forecast vulnerability under variation of power injection was used to predict the vulnerable area of next step and verify the current vulnerable area.Numerical simulation was performed under variant operating conditions with IEEE-30 bus system,which shows that almost area of 90% overlaps between current vulnerable area and forecasting vulnerable area,the overlapped area is termed as inherent vulnerable area of grid.When considering N-1 contingency,the assessment results of this method proposed agree with those of optimal power flow.When considering N-2 contingency,optimal power flow fails to obtain correct results,while the method based on energy framework gives reliable results.展开更多
基金supported by National Key R&D Program of China(No.2021YFB2401100).
文摘The modular multilevel matrix converter(M3C)is a potential frequency converter for low-frequency AC transmission.However,capacitor voltage control of high-voltage and largecapacity M3C is more difficult,especially for voltage balancing between branches.To solve this problem,this paper defines sequence circulating components and theoretically analyzes the influence mechanism of different sequence circulating components on branch capacitor voltage.A fully decoupled branch energy balancing control method based on four groups of sequence circulating components is proposed.This method can control capacitor voltages of nine branches in horizontal,vertical and diagonal directions.Considering influences of both circulating current and voltage,a cross decoupled control is designed to improve control precision.Simulation results are taken from a low-frequency transmission system based on PSCAD/EMTDC,and effectiveness and precision of the proposed branch energy balancing control method are verified in the case of nonuniform parameters and an unbalanced power system.
基金Project(51007006) supported by the National Natural Science Foundation of ChinaProject(20090185120023) supported by the Ph.D Programs Foundation for New Teacher of Ministry of Education of China
文摘A potential energy framework for assessment of grid vulnerability was presented.In the framework,the branch potential energy function model was constructed.Two indexes,current vulnerability and forecasting vulnerability,were calculated.The current vulnerability was used to identify the current vulnerable area through calculating the distance between the current transmitted power and initial transmitted power;and the forecast vulnerability under variation of power injection was used to predict the vulnerable area of next step and verify the current vulnerable area.Numerical simulation was performed under variant operating conditions with IEEE-30 bus system,which shows that almost area of 90% overlaps between current vulnerable area and forecasting vulnerable area,the overlapped area is termed as inherent vulnerable area of grid.When considering N-1 contingency,the assessment results of this method proposed agree with those of optimal power flow.When considering N-2 contingency,optimal power flow fails to obtain correct results,while the method based on energy framework gives reliable results.