The High-energy Fragment Separator(HFRS),which is currently under construction,is a leading international radioactive beam device.Multiple sets of position-sensitive twin time projection chamber(TPC)detectors are dist...The High-energy Fragment Separator(HFRS),which is currently under construction,is a leading international radioactive beam device.Multiple sets of position-sensitive twin time projection chamber(TPC)detectors are distributed on HFRS for particle identification and beam monitoring.The twin TPCs'readout electronics system operates in a trigger-less mode due to its high counting rate,leading to a challenge of handling large amounts of data.To address this problem,we introduced an event-building algorithm.This algorithm employs a hierarchical processing strategy to compress data during transmission and aggregation.In addition,it reconstructs twin TPCs'events online and stores only the reconstructed particle information,which significantly reduces the burden on data transmission and storage resources.Simulation studies demonstrated that the algorithm accurately matches twin TPCs'events and reduces more than 98%of the data volume at a counting rate of 500 kHz/channel.展开更多
This article focuses on the challenges ofmodeling energy supply systems for buildings,encompassing both methods and tools for simulating thermal regimes and engineering systems within buildings.Enhancing the comfort o...This article focuses on the challenges ofmodeling energy supply systems for buildings,encompassing both methods and tools for simulating thermal regimes and engineering systems within buildings.Enhancing the comfort of living or working in buildings often necessitates increased consumption of energy and material,such as for thermal upgrades,which consequently incurs additional economic costs.It is crucial to acknowledge that such improvements do not always lead to a decrease in total pollutant emissions,considering emissions across all stages of production and usage of energy and materials aimed at boosting energy efficiency and comfort in buildings.In addition,it explores the methods and mechanisms for modeling the operating modes of electric boilers used to collectively improve energy efficiency and indoor climatic conditions.Using the developed mathematical models,the study examines the dynamic states of building energy supply systems and provides recommendations for improving their efficiency.These dynamic models are executed in software environments such as MATLAB/Simscape and Python,where the component detailing schemes for various types of controllers are demonstrated.Additionally,controllers based on reinforcement learning(RL)displayed more adaptive load level management.These RL-based controllers can lower instantaneous power usage by up to 35%,reduce absolute deviations from a comfortable temperature nearly by half,and cut down energy consumption by approximately 1%while maintaining comfort.When the energy source produces a constant energy amount,the RL-based heat controllermore effectively maintains the temperature within the set range,preventing overheating.In conclusion,the introduced energydynamic building model and its software implementation offer a versatile tool for researchers,enabling the simulation of various energy supply systems to achieve optimal energy efficiency and indoor climate control in buildings.展开更多
Collisions between a moving mass and an anti-collision device increase structural responses and threaten structural safety.An active mass damper(AMD)with stroke limitations is often used to avoid collisions.However,a ...Collisions between a moving mass and an anti-collision device increase structural responses and threaten structural safety.An active mass damper(AMD)with stroke limitations is often used to avoid collisions.However,a strokelimited AMD control system with a fixed limited area shortens the available AMD stroke and leads to significant control power.To solve this problem,the design approach with variable gain and limited area(VGLA)is proposed in this study.First,the boundary of variable-limited areas is calculated based on the real-time status of the moving mass.The variable gain(VG)expression at the variable limited area is deduced by considering the saturation of AMD stroke.Then,numerical simulations of a stroke-limited AMD control system with VGLA are conducted on a high-rise building structure.These numerical simulations show that the proposed approach has superior strokelimitation performance compared with a stroke-limited AMD control system with a fixed limited area.Finally,the proposed approach is validated through experiments on a four-story steel frame.展开更多
Building emission reduction is an important way to achieve China’s carbon peaking and carbon neutrality goals.Aiming at the problem of low carbon economic operation of a photovoltaic energy storage building system,a ...Building emission reduction is an important way to achieve China’s carbon peaking and carbon neutrality goals.Aiming at the problem of low carbon economic operation of a photovoltaic energy storage building system,a multi-time scale optimal scheduling strategy based on model predictive control(MPC)is proposed under the consideration of load optimization.First,load optimization is achieved by controlling the charging time of electric vehicles as well as adjusting the air conditioning operation temperature,and the photovoltaic energy storage building system model is constructed to propose a day-ahead scheduling strategy with the lowest daily operation cost.Second,considering inter-day to intra-day source-load prediction error,an intraday rolling optimal scheduling strategy based on MPC is proposed that dynamically corrects the day-ahead dispatch results to stabilize system power fluctuations and promote photovoltaic consumption.Finally,taking an office building on a summer work day as an example,the effectiveness of the proposed scheduling strategy is verified.The results of the example show that the strategy reduces the total operating cost of the photovoltaic energy storage building system by 17.11%,improves the carbon emission reduction by 7.99%,and the photovoltaic consumption rate reaches 98.57%,improving the system’s low-carbon and economic performance.展开更多
The functionality of buildings depends on the climate they are subjected to,this means buildings constructed these days need to be built to perform efficiently within the current and future climate and with the aim of...The functionality of buildings depends on the climate they are subjected to,this means buildings constructed these days need to be built to perform efficiently within the current and future climate and with the aim of reducing the greenhouse emission induced on the environment.In order to lower CO_(2) emissions and assist in reinforcing the capability of cities to adapt to climate change whilst enhancing the quality of the built environment,it is vital to improve the environmental performance and energy efficiency in buildings.This study aims to identify and compare existing GBRS(green building rating system)with Nigerian climatic condition.Proposal criteria weighting was developed from the questionnaire supplying expert opinions.It began with a comparative analysis of GBRS.The analysis was conducted to find the similarities and differences between existing rating systems and come up with an appropriate rating system for Nigeria.These approaches included a fieldwork approach(pilot study,survey);questionnaire;and interviews,both structured and unstructured.Then,the information generated in this pre-test investigation formed the conversational guide and described the decision to determine the main factors that should be involved in the new assessment system for Nigeria.展开更多
With the advancement of the transformation,the contradiction between the residents’demand for a better living environment and the convenience of living in the settlements comes to the fore.Effective identification,or...With the advancement of the transformation,the contradiction between the residents’demand for a better living environment and the convenience of living in the settlements comes to the fore.Effective identification,organic integration,timely adoption,and correct decision-making for the transformation of old neighborhoods are pressing issues in the transformation of old neighborhoods.Therefore,this paper takes the green building evaluation standards of various countries as the research basis and support for the construction of the transformation strategy of old neighborhoods.Through the collection and comparative analysis of the indicators of green building evaluation standards,the index system of transformation is formed,and it also provides a certain foundation for the subsequent related research.展开更多
Green energy conservation is the mainstream trend in the current development of the construction industry.The application of energy-saving technology in building electrical system design can effectively reduce energy ...Green energy conservation is the mainstream trend in the current development of the construction industry.The application of energy-saving technology in building electrical system design can effectively reduce energy consumption,avoid unnecessary energy consumption,and truly achieve energy conservation and environmental protection.Based on this,the article elaborates on the principles of energy-saving design in building electrical systems,and actively explores the application of energy-saving technologies from different perspectives such as optimizing power supply and distribution system design,adopting high-efficiency energy-saving lighting equipment,applying renewable energy,promoting smart home technology,and improving the efficiency of building electrical equipment.展开更多
The central air conditioning system in an intelligent building (IB) was analyzed and modeled in order to perform the optimization scheduling strategy of the central air conditioning system. A set of models proposed ...The central air conditioning system in an intelligent building (IB) was analyzed and modeled in order to perform the optimization scheduling strategy of the central air conditioning system. A set of models proposed and a type of periodically autoregressive model (PAR) based on the improved genetic algorithms (IGA) were used to perform the optimum energy saving scheduling. The example of the Liangmahe Plaza was taken to show the effectiveness of the methods.展开更多
A water loop variable refrigerant flow(WLVRF)air-conditioning system is designed to be applied in large-scale buildings in northern China.The system is energy saving and it is an integrated system consisting of a va...A water loop variable refrigerant flow(WLVRF)air-conditioning system is designed to be applied in large-scale buildings in northern China.The system is energy saving and it is an integrated system consisting of a variable refrigerant flow(VRF)air-conditioning unit,a water loop and an air source heat pump.The water loop transports energy among different regions in the buildings instead of refrigerant pipes,decreasing the scale of the VRF air-conditioning unit and improving the performance.Previous models for refrigerants and building loads are cited in this investigation.Mathematical models of major equipment and other elements of the system are established using the lumped parameter method based on the DATAFIT software and the MATLAB software.The performance of the WLVRF system is simulated.The initial investments and the running costs are calculated based on the results of market research.Finally,a contrast is carried out between the WLVRF system and the traditional VRF system.The results show that the WLVRF system has a better working condition and lower running costs than the traditional VRF system.展开更多
An optimum energy saving scheduling strategy of the central air conditioning system in an intelligent building (IB) was proposed. Based on the system analysis a set of models of the central air conditioning system w...An optimum energy saving scheduling strategy of the central air conditioning system in an intelligent building (IB) was proposed. Based on the system analysis a set of models of the central air conditioning system was established. The periodically autoregressive models (PARM) based on genetic algorithms (GA) were used to predict the next day’s cold load. The improved genetic algorithms (IGA) with stochastic real number coding were used to finish the optimum energy saving scheduling of the system. The simulation results for the building of the Liangmahe Plaza show that the proposed strategy can save energy up to about 24 5%.展开更多
This paper describes a set of on-site earthquake safety evaluation systems for buildings, which were developed based on a network platform. The system embedded into the quantitative research results which were complet...This paper describes a set of on-site earthquake safety evaluation systems for buildings, which were developed based on a network platform. The system embedded into the quantitative research results which were completed in accordance with the provisions from Post-earthquake Field Works, Part 2: Safety Assessment of Buildings, GB18208.2 -2001, and was further developed into an easy-to-use software platform. The system is aimed at allowing engineering professionals, civil engineeing technicists or earthquake-affected victims on site to assess damaged buildings through a network after earthquakes. The authors studied the function structure, process design of the safety evaluation module, and hierarchical analysis algorithm module of the system in depth, and developed the general architecture design, development technology and database design of the system. Technologies such as hierarchical architecture design and Java EE were used in the system development, and MySQL5 was adopted in the database development. The result is a complete evaluation process of information collection, safety evaluation, and output of damage and safety degrees, as well as query and statistical analysis of identified buildings. The system can play a positive role in sharing expert post-earthquake experience and promoting safety evaluation of buildings on a seismic field.展开更多
To date, the high power arc plasma technology is widely used. A next generation high power arc plasma system based on building block structure is presented. The whole arc plasma inverter system is composed of 12 paral...To date, the high power arc plasma technology is widely used. A next generation high power arc plasma system based on building block structure is presented. The whole arc plasma inverter system is composed of 12 paralleled units to increase the system output capability. The hierarchical control system is adopted to improve the reliability and flexibility of the high power arc plasma inverter. To ensure the reliable turn on and off of the IGBT module in each building block unit, a special pulse drive circuit is designed by using pulse transformer. The experimental result indicates that the high power arc plasma inverter system can transfer 300 kW arc plasma energy reliably with high efficiency.展开更多
A multistage assessment index set is chosen based on the analysis of building fire safety system, whereby the weight of each index is determined through an analy tie.hierarchy process; a fuzzy synthetic assessment mod...A multistage assessment index set is chosen based on the analysis of building fire safety system, whereby the weight of each index is determined through an analy tie.hierarchy process; a fuzzy synthetic assessment model for the building fire safety system is constructed, and the quantified result was obtained by using hierarchy parameter judgment. This fuzzy synthetic assessment method can quantify assessment result of the building fire safety system, so thatthe fire precautions may be accurately adopted, and the serious potential risk may be avoided. The application shows that this method possesses both objectivity and feasibility.展开更多
For the carbon-neutral,a multi-carrier renewable energy system(MRES),driven by the wind,solar and geothermal,was considered as an effective solution to mitigate CO2emissions and reduce energy usage in the building sec...For the carbon-neutral,a multi-carrier renewable energy system(MRES),driven by the wind,solar and geothermal,was considered as an effective solution to mitigate CO2emissions and reduce energy usage in the building sector.A proper sizing method was essential for achieving the desired 100%renewable energy system of resources.This paper presented a bi-objective optimization formulation for sizing the MRES using a constrained genetic algorithm(GA)coupled with the loss of power supply probability(LPSP)method to achieve the minimal cost of the system and the reliability of the system to the load real time requirement.An optimization App has been developed in MATLAB environment to offer a user-friendly interface and output the optimized design parameters when given the load demand.A case study of a swimming pool building was used to demonstrate the process of the proposed design method.Compared to the conventional distributed energy system,the MRES is feasible with a lower annual total cost(ATC).Additionally,the ATC decreases as the power supply reliability of the renewable system decreases.There is a decrease of 24%of the annual total cost when the power supply probability is equal to 8%compared to the baseline case with 0%power supply probability.展开更多
In the face of climate change and with the vision for the future of humanity represented by the Sustainability Development Goals,sustainability has become associated with the major and rapid transformation of global s...In the face of climate change and with the vision for the future of humanity represented by the Sustainability Development Goals,sustainability has become associated with the major and rapid transformation of global systems and the resilience of transformed systems to adapt over time.This dynamic view of transformation has implications for both the design of tran sformatio nal energy in itiatives and their evaluation.As there is an urge nt n eed to evaluate the scale,scope,nature,and sufficiency of transformation toward planetary sustainability,a framework(model)is proposed to determine the most effective en ergy evaluati on capacity buildi ng strategies for achievi ng various in dividual and group level outcomes,most effective strategies for certain types of participants,and design of different strategies to maximize their impact in a sustainable way.Furthermore,a new energy evaluation organization is identified,which is expected to lead us into this new era.展开更多
Underground pipeline networks constitute a major component of urban infrastructure,and thus,it is imperative to have an efficient mechanism to manage them.This study introduces a secondary development system to effici...Underground pipeline networks constitute a major component of urban infrastructure,and thus,it is imperative to have an efficient mechanism to manage them.This study introduces a secondary development system to efficiently model underground pipeline networks,using the building information modeling(BIM)-based software Revit.The system comprises separate pipe point and tubulation models.Using a Revit application programming interface(API),the spatial position and attribute data of the pipe points are extracted from a pipeline database,and the corresponding tubulation data are extracted from a tubulation database.Using the Family class in Revit API,the cluster in the self-built library of pipe point is inserted into the spatial location and the attribute data is added;in the same way,all pipeline instances in the pipeline system are created.The extension and localization of the model accelerated the modeling speed.The system was then used in a real construction project.The expansion of the model database and rapid modeling made the application of BIM technology in three-dimensional visualization of underground pipeline networks more convenient.Furthermore,it has applications in pipeline engineering construction and management.展开更多
The energy saving issue of chilled water system in an intelligent building is analyzed from the systematic point of view, and an optimum scheduling scheme which can save energy of the system facilities and satisfy the...The energy saving issue of chilled water system in an intelligent building is analyzed from the systematic point of view, and an optimum scheduling scheme which can save energy of the system facilities and satisfy the constraints of the real time cold loads and system running is also proposed. It can make the minimum cost of the system by optimizing the number of running chillers, running parameters and the distribution of real time loads of running chillers. The improved genetic algorithm is used in the optimum scheduling scheme. The computation results show that the building energy consumption can be decreased by about 10%.展开更多
Two building factors-a longer thermal lag of more than one hour for building envelops and a lag of indoor radiation to convert into cooling load-have impact on the instantaneous heat input and instantaneous cooling lo...Two building factors-a longer thermal lag of more than one hour for building envelops and a lag of indoor radiation to convert into cooling load-have impact on the instantaneous heat input and instantaneous cooling load.So the two factors should be taken into account when selecting the weather parameters for air-conditioning system design.This paper developed a new statistic method for the rational selection of coincident solar irradiance,dry-bulb and wet-bulb temperatures.The method was applied to historic weather records of 25 years in Hong Kong to generate coincident design weather data.And the results show that traditional design solar irradiance,dry-bulb and wet-bulb temperatures may be significantly overestimated in many conditions,and the design weather data for the three different constructions is not kept constant.展开更多
An experimental method is introduced in this paper to build the dynamics of AMSS (the active magnetic suspension system), which doesn’t depend on system’s physical parameters. The rotor can be reliably suspended und...An experimental method is introduced in this paper to build the dynamics of AMSS (the active magnetic suspension system), which doesn’t depend on system’s physical parameters. The rotor can be reliably suspended under the unit feedback control system designed with the primary dynamic model obtained. Online identification in frequency domain is processed to give the precise model. Comparisons show that the experimental method is much closer to the precise model than the theoretic method based on magnetic circuit law. So this experimental method is a good choice to build the primary dynamic model of AMSS.展开更多
The present building facility management status in China resulted in many problems such as high energy consumption,failure of automation control,services failure and poor indoor air quality.Based on questionnaires and...The present building facility management status in China resulted in many problems such as high energy consumption,failure of automation control,services failure and poor indoor air quality.Based on questionnaires and interviews to professional engineers and building users,a comprehensive evaluation index system was established on facility management of high-rise office buildings.A Fuzzy AHP based upon hierarchy criteria system was established.A Fuzzy AHP Evaluation Model on Facility Management System was set up;α-cut analysis was introduced and incorporated with expert knowledge together,which made up the optimism index λ.The fuzzy optimum crisp weight of each criterion was resulted from data-mining.Case investigations were processed in high-rise office buildings in Shenyang.The results illustrated that indoor air quality,thermal comfort and life cycle cost were the most important indexes in the evaluation of Facility Management System of high rise office buildings.Residents in high-rise buildings in Shenyang pay less attention to maintenance management and environment protection.By comparison with the analysis result of Export Choice,Fuzzy AHP-based evaluation model could act as a scientific reference for the establishment of governmental standards in facility management area in building.展开更多
基金partially supported by the Strategic Priority Research Program of Chinese Academy of Science(No.XDB 34030000)the National Natural Science Foundation of China(Nos.11975293 and 12205348)。
文摘The High-energy Fragment Separator(HFRS),which is currently under construction,is a leading international radioactive beam device.Multiple sets of position-sensitive twin time projection chamber(TPC)detectors are distributed on HFRS for particle identification and beam monitoring.The twin TPCs'readout electronics system operates in a trigger-less mode due to its high counting rate,leading to a challenge of handling large amounts of data.To address this problem,we introduced an event-building algorithm.This algorithm employs a hierarchical processing strategy to compress data during transmission and aggregation.In addition,it reconstructs twin TPCs'events online and stores only the reconstructed particle information,which significantly reduces the burden on data transmission and storage resources.Simulation studies demonstrated that the algorithm accurately matches twin TPCs'events and reduces more than 98%of the data volume at a counting rate of 500 kHz/channel.
文摘This article focuses on the challenges ofmodeling energy supply systems for buildings,encompassing both methods and tools for simulating thermal regimes and engineering systems within buildings.Enhancing the comfort of living or working in buildings often necessitates increased consumption of energy and material,such as for thermal upgrades,which consequently incurs additional economic costs.It is crucial to acknowledge that such improvements do not always lead to a decrease in total pollutant emissions,considering emissions across all stages of production and usage of energy and materials aimed at boosting energy efficiency and comfort in buildings.In addition,it explores the methods and mechanisms for modeling the operating modes of electric boilers used to collectively improve energy efficiency and indoor climatic conditions.Using the developed mathematical models,the study examines the dynamic states of building energy supply systems and provides recommendations for improving their efficiency.These dynamic models are executed in software environments such as MATLAB/Simscape and Python,where the component detailing schemes for various types of controllers are demonstrated.Additionally,controllers based on reinforcement learning(RL)displayed more adaptive load level management.These RL-based controllers can lower instantaneous power usage by up to 35%,reduce absolute deviations from a comfortable temperature nearly by half,and cut down energy consumption by approximately 1%while maintaining comfort.When the energy source produces a constant energy amount,the RL-based heat controllermore effectively maintains the temperature within the set range,preventing overheating.In conclusion,the introduced energydynamic building model and its software implementation offer a versatile tool for researchers,enabling the simulation of various energy supply systems to achieve optimal energy efficiency and indoor climate control in buildings.
基金This research was founded by the Funds for Creative Research Groups of National Natural Science Foundation of China(Grant No.51921006)the National Natural Science Foundations of China(Grant No.51978224)+2 种基金the National Major Scientific Research Instrument Development Program of China(Grant No.51827811)the National Natural Science Foundation of China,(Grant No.52008141)the Shenzhen Technology Innovation Program(Grant Nos.JCYJ20170811160003571,JCYJ20180508152238111 and JCYJ20200109112803851).
文摘Collisions between a moving mass and an anti-collision device increase structural responses and threaten structural safety.An active mass damper(AMD)with stroke limitations is often used to avoid collisions.However,a strokelimited AMD control system with a fixed limited area shortens the available AMD stroke and leads to significant control power.To solve this problem,the design approach with variable gain and limited area(VGLA)is proposed in this study.First,the boundary of variable-limited areas is calculated based on the real-time status of the moving mass.The variable gain(VG)expression at the variable limited area is deduced by considering the saturation of AMD stroke.Then,numerical simulations of a stroke-limited AMD control system with VGLA are conducted on a high-rise building structure.These numerical simulations show that the proposed approach has superior strokelimitation performance compared with a stroke-limited AMD control system with a fixed limited area.Finally,the proposed approach is validated through experiments on a four-story steel frame.
文摘Building emission reduction is an important way to achieve China’s carbon peaking and carbon neutrality goals.Aiming at the problem of low carbon economic operation of a photovoltaic energy storage building system,a multi-time scale optimal scheduling strategy based on model predictive control(MPC)is proposed under the consideration of load optimization.First,load optimization is achieved by controlling the charging time of electric vehicles as well as adjusting the air conditioning operation temperature,and the photovoltaic energy storage building system model is constructed to propose a day-ahead scheduling strategy with the lowest daily operation cost.Second,considering inter-day to intra-day source-load prediction error,an intraday rolling optimal scheduling strategy based on MPC is proposed that dynamically corrects the day-ahead dispatch results to stabilize system power fluctuations and promote photovoltaic consumption.Finally,taking an office building on a summer work day as an example,the effectiveness of the proposed scheduling strategy is verified.The results of the example show that the strategy reduces the total operating cost of the photovoltaic energy storage building system by 17.11%,improves the carbon emission reduction by 7.99%,and the photovoltaic consumption rate reaches 98.57%,improving the system’s low-carbon and economic performance.
文摘The functionality of buildings depends on the climate they are subjected to,this means buildings constructed these days need to be built to perform efficiently within the current and future climate and with the aim of reducing the greenhouse emission induced on the environment.In order to lower CO_(2) emissions and assist in reinforcing the capability of cities to adapt to climate change whilst enhancing the quality of the built environment,it is vital to improve the environmental performance and energy efficiency in buildings.This study aims to identify and compare existing GBRS(green building rating system)with Nigerian climatic condition.Proposal criteria weighting was developed from the questionnaire supplying expert opinions.It began with a comparative analysis of GBRS.The analysis was conducted to find the similarities and differences between existing rating systems and come up with an appropriate rating system for Nigeria.These approaches included a fieldwork approach(pilot study,survey);questionnaire;and interviews,both structured and unstructured.Then,the information generated in this pre-test investigation formed the conversational guide and described the decision to determine the main factors that should be involved in the new assessment system for Nigeria.
文摘With the advancement of the transformation,the contradiction between the residents’demand for a better living environment and the convenience of living in the settlements comes to the fore.Effective identification,organic integration,timely adoption,and correct decision-making for the transformation of old neighborhoods are pressing issues in the transformation of old neighborhoods.Therefore,this paper takes the green building evaluation standards of various countries as the research basis and support for the construction of the transformation strategy of old neighborhoods.Through the collection and comparative analysis of the indicators of green building evaluation standards,the index system of transformation is formed,and it also provides a certain foundation for the subsequent related research.
文摘Green energy conservation is the mainstream trend in the current development of the construction industry.The application of energy-saving technology in building electrical system design can effectively reduce energy consumption,avoid unnecessary energy consumption,and truly achieve energy conservation and environmental protection.Based on this,the article elaborates on the principles of energy-saving design in building electrical systems,and actively explores the application of energy-saving technologies from different perspectives such as optimizing power supply and distribution system design,adopting high-efficiency energy-saving lighting equipment,applying renewable energy,promoting smart home technology,and improving the efficiency of building electrical equipment.
文摘The central air conditioning system in an intelligent building (IB) was analyzed and modeled in order to perform the optimization scheduling strategy of the central air conditioning system. A set of models proposed and a type of periodically autoregressive model (PAR) based on the improved genetic algorithms (IGA) were used to perform the optimum energy saving scheduling. The example of the Liangmahe Plaza was taken to show the effectiveness of the methods.
文摘A water loop variable refrigerant flow(WLVRF)air-conditioning system is designed to be applied in large-scale buildings in northern China.The system is energy saving and it is an integrated system consisting of a variable refrigerant flow(VRF)air-conditioning unit,a water loop and an air source heat pump.The water loop transports energy among different regions in the buildings instead of refrigerant pipes,decreasing the scale of the VRF air-conditioning unit and improving the performance.Previous models for refrigerants and building loads are cited in this investigation.Mathematical models of major equipment and other elements of the system are established using the lumped parameter method based on the DATAFIT software and the MATLAB software.The performance of the WLVRF system is simulated.The initial investments and the running costs are calculated based on the results of market research.Finally,a contrast is carried out between the WLVRF system and the traditional VRF system.The results show that the WLVRF system has a better working condition and lower running costs than the traditional VRF system.
文摘An optimum energy saving scheduling strategy of the central air conditioning system in an intelligent building (IB) was proposed. Based on the system analysis a set of models of the central air conditioning system was established. The periodically autoregressive models (PARM) based on genetic algorithms (GA) were used to predict the next day’s cold load. The improved genetic algorithms (IGA) with stochastic real number coding were used to finish the optimum energy saving scheduling of the system. The simulation results for the building of the Liangmahe Plaza show that the proposed strategy can save energy up to about 24 5%.
基金Major Research Plan of the National Natural Science Foundation of China under Grant No.91315301-10Project of Earthquake Code Compilation and Revising:Postearthquake Field Works-Part 2:Safety Assessment of Buildings under Grant No.14410024701Basic Scientific Research Special Project of IEM,CEA under Grant No.2009A01
文摘This paper describes a set of on-site earthquake safety evaluation systems for buildings, which were developed based on a network platform. The system embedded into the quantitative research results which were completed in accordance with the provisions from Post-earthquake Field Works, Part 2: Safety Assessment of Buildings, GB18208.2 -2001, and was further developed into an easy-to-use software platform. The system is aimed at allowing engineering professionals, civil engineeing technicists or earthquake-affected victims on site to assess damaged buildings through a network after earthquakes. The authors studied the function structure, process design of the safety evaluation module, and hierarchical analysis algorithm module of the system in depth, and developed the general architecture design, development technology and database design of the system. Technologies such as hierarchical architecture design and Java EE were used in the system development, and MySQL5 was adopted in the database development. The result is a complete evaluation process of information collection, safety evaluation, and output of damage and safety degrees, as well as query and statistical analysis of identified buildings. The system can play a positive role in sharing expert post-earthquake experience and promoting safety evaluation of buildings on a seismic field.
基金supported by National Natural Science Foundation of China (50805051)Guangdong Provincial Science and Technology Project (2008B010400041)
文摘To date, the high power arc plasma technology is widely used. A next generation high power arc plasma system based on building block structure is presented. The whole arc plasma inverter system is composed of 12 paralleled units to increase the system output capability. The hierarchical control system is adopted to improve the reliability and flexibility of the high power arc plasma inverter. To ensure the reliable turn on and off of the IGBT module in each building block unit, a special pulse drive circuit is designed by using pulse transformer. The experimental result indicates that the high power arc plasma inverter system can transfer 300 kW arc plasma energy reliably with high efficiency.
文摘A multistage assessment index set is chosen based on the analysis of building fire safety system, whereby the weight of each index is determined through an analy tie.hierarchy process; a fuzzy synthetic assessment model for the building fire safety system is constructed, and the quantified result was obtained by using hierarchy parameter judgment. This fuzzy synthetic assessment method can quantify assessment result of the building fire safety system, so thatthe fire precautions may be accurately adopted, and the serious potential risk may be avoided. The application shows that this method possesses both objectivity and feasibility.
基金Project(52108101)supported by the National Natural Science Foundation of ChinaProjects(2020GK4057,2021JJ40759)supported by the Hunan Provincial Science and Technology Department,China。
文摘For the carbon-neutral,a multi-carrier renewable energy system(MRES),driven by the wind,solar and geothermal,was considered as an effective solution to mitigate CO2emissions and reduce energy usage in the building sector.A proper sizing method was essential for achieving the desired 100%renewable energy system of resources.This paper presented a bi-objective optimization formulation for sizing the MRES using a constrained genetic algorithm(GA)coupled with the loss of power supply probability(LPSP)method to achieve the minimal cost of the system and the reliability of the system to the load real time requirement.An optimization App has been developed in MATLAB environment to offer a user-friendly interface and output the optimized design parameters when given the load demand.A case study of a swimming pool building was used to demonstrate the process of the proposed design method.Compared to the conventional distributed energy system,the MRES is feasible with a lower annual total cost(ATC).Additionally,the ATC decreases as the power supply reliability of the renewable system decreases.There is a decrease of 24%of the annual total cost when the power supply probability is equal to 8%compared to the baseline case with 0%power supply probability.
文摘In the face of climate change and with the vision for the future of humanity represented by the Sustainability Development Goals,sustainability has become associated with the major and rapid transformation of global systems and the resilience of transformed systems to adapt over time.This dynamic view of transformation has implications for both the design of tran sformatio nal energy in itiatives and their evaluation.As there is an urge nt n eed to evaluate the scale,scope,nature,and sufficiency of transformation toward planetary sustainability,a framework(model)is proposed to determine the most effective en ergy evaluati on capacity buildi ng strategies for achievi ng various in dividual and group level outcomes,most effective strategies for certain types of participants,and design of different strategies to maximize their impact in a sustainable way.Furthermore,a new energy evaluation organization is identified,which is expected to lead us into this new era.
基金supported by a grant(No.14DZ2292800,http://www.greengeo.net/)from“Technology Service Platform of Civil Engineering”of Science and Technology Commission of Shanghai Municipality.
文摘Underground pipeline networks constitute a major component of urban infrastructure,and thus,it is imperative to have an efficient mechanism to manage them.This study introduces a secondary development system to efficiently model underground pipeline networks,using the building information modeling(BIM)-based software Revit.The system comprises separate pipe point and tubulation models.Using a Revit application programming interface(API),the spatial position and attribute data of the pipe points are extracted from a pipeline database,and the corresponding tubulation data are extracted from a tubulation database.Using the Family class in Revit API,the cluster in the self-built library of pipe point is inserted into the spatial location and the attribute data is added;in the same way,all pipeline instances in the pipeline system are created.The extension and localization of the model accelerated the modeling speed.The system was then used in a real construction project.The expansion of the model database and rapid modeling made the application of BIM technology in three-dimensional visualization of underground pipeline networks more convenient.Furthermore,it has applications in pipeline engineering construction and management.
文摘The energy saving issue of chilled water system in an intelligent building is analyzed from the systematic point of view, and an optimum scheduling scheme which can save energy of the system facilities and satisfy the constraints of the real time cold loads and system running is also proposed. It can make the minimum cost of the system by optimizing the number of running chillers, running parameters and the distribution of real time loads of running chillers. The improved genetic algorithm is used in the optimum scheduling scheme. The computation results show that the building energy consumption can be decreased by about 10%.
文摘Two building factors-a longer thermal lag of more than one hour for building envelops and a lag of indoor radiation to convert into cooling load-have impact on the instantaneous heat input and instantaneous cooling load.So the two factors should be taken into account when selecting the weather parameters for air-conditioning system design.This paper developed a new statistic method for the rational selection of coincident solar irradiance,dry-bulb and wet-bulb temperatures.The method was applied to historic weather records of 25 years in Hong Kong to generate coincident design weather data.And the results show that traditional design solar irradiance,dry-bulb and wet-bulb temperatures may be significantly overestimated in many conditions,and the design weather data for the three different constructions is not kept constant.
基金Supported by the National Nature Foundation of China (No.59975073)
文摘An experimental method is introduced in this paper to build the dynamics of AMSS (the active magnetic suspension system), which doesn’t depend on system’s physical parameters. The rotor can be reliably suspended under the unit feedback control system designed with the primary dynamic model obtained. Online identification in frequency domain is processed to give the precise model. Comparisons show that the experimental method is much closer to the precise model than the theoretic method based on magnetic circuit law. So this experimental method is a good choice to build the primary dynamic model of AMSS.
文摘The present building facility management status in China resulted in many problems such as high energy consumption,failure of automation control,services failure and poor indoor air quality.Based on questionnaires and interviews to professional engineers and building users,a comprehensive evaluation index system was established on facility management of high-rise office buildings.A Fuzzy AHP based upon hierarchy criteria system was established.A Fuzzy AHP Evaluation Model on Facility Management System was set up;α-cut analysis was introduced and incorporated with expert knowledge together,which made up the optimism index λ.The fuzzy optimum crisp weight of each criterion was resulted from data-mining.Case investigations were processed in high-rise office buildings in Shenyang.The results illustrated that indoor air quality,thermal comfort and life cycle cost were the most important indexes in the evaluation of Facility Management System of high rise office buildings.Residents in high-rise buildings in Shenyang pay less attention to maintenance management and environment protection.By comparison with the analysis result of Export Choice,Fuzzy AHP-based evaluation model could act as a scientific reference for the establishment of governmental standards in facility management area in building.