The district cooling system (DCS) with ice storage can reduce the peak electricity demand of the business district buildings it serves, improve system efficiency, and lower operational costs. This study utilizes a mon...The district cooling system (DCS) with ice storage can reduce the peak electricity demand of the business district buildings it serves, improve system efficiency, and lower operational costs. This study utilizes a monitoring and control platform for DCS with ice storage to analyze historical parameter values related to system operation and executed operations. We assess the distribution of cooling loads among various devices within the DCS, identify operational characteristics of the system through correlation analysis and principal component analysis (PCA), and subsequently determine key parameters affecting changes in cooling loads. Accurate forecasting of cooling loads is crucial for determining optimal control strategies. The research process can be summarized briefly as follows: data preprocessing, parameter analysis, parameter selection, and validation of load forecasting performance. The study reveals that while individual devices in the system perform well, there is considerable room for improving overall system efficiency. Six principal components have been identified as input parameters for the cold load forecasting model, with each of these components having eigenvalues greater than 1 and contributing to an accumulated variance of 87.26%, and during the dimensionality reduction process, we obtained a confidence ellipse with a 95% confidence interval. Regarding cooling load forecasting, the Relative Absolute Error (RAE) value of the light gradient boosting machine (lightGBM) algorithm is 3.62%, Relative Root Mean Square Error (RRMSE) is 42.75%, and R-squared value (R<sup>2</sup>) is 92.96%, indicating superior forecasting performance compared to other commonly used cooling load forecasting algorithms. This research provides valuable insights and auxiliary guidance for data analysis and optimizing operations in practical engineering applications. .展开更多
An actively water-cooled limiter has been designed for the long pulse operation of an HT-7 device, by adopting an integrated structure-doped graphite and a copper alloy heat sink with a super carbon sheet serving as a...An actively water-cooled limiter has been designed for the long pulse operation of an HT-7 device, by adopting an integrated structure-doped graphite and a copper alloy heat sink with a super carbon sheet serving as a compliant layer between them. The behaviors of the integrated structure were evaluated in an electron beam facility under different heat loads and cooling conditions. The surface temperature and bulk temperature distribution were carefully measured by optical pyrometers and thermocouples under a steady state heat flux of 1 to 5 MW/m^2 and a water flow rate of 3 m^3/h, 4.5 m^3/h and 6 m^3/h, respectively. It was found that the surface temperature increased rapidly with the heat flux rising, but decreased only slightly with the water flow rate rising. The surface temperature reached approximately 1200℃ at 5 MW/m^2 of heat flux and 6 m^3/h of water flow. The primary experimental results indicate that the integrated design meets the requirements for the heat expelling capacity of the HT-7 device. A set of numerical simulations was also completed, whose outcome was in good accord with the experimental results.展开更多
The prediction of the heating and cooling loads of a building is an essential aspect in studies involving the analysis of energy consumption in buildings. An accurate estimation of heating and cooling load leads to be...The prediction of the heating and cooling loads of a building is an essential aspect in studies involving the analysis of energy consumption in buildings. An accurate estimation of heating and cooling load leads to better management of energy related tasks and progressing towards an energy efficient building. With increasing global energy demands and buildings being major energy consuming entities, there is renewed interest in studying the energy performance of buildings. Alternative technologies like Artificial Intelligence (AI) techniques are being widely used in energy studies involving buildings. This paper presents a review of research in the area of forecasting the heating and cooling load of buildings using AI techniques. The results discussed in this paper demonstrate the use of AI techniques in the estimation of the thermal loads of buildings. An accurate prediction of the heating and cooling loads of buildings is necessary for forecasting the energy expenditure in buildings. It can also help in the design and construction of energy efficient buildings.展开更多
The heat transfer performance of the phase change materials used in free cooling and air conditioning applications is low,due to the poor thermal conductivity of the materials.The recent phenomenal advancement in nano...The heat transfer performance of the phase change materials used in free cooling and air conditioning applications is low,due to the poor thermal conductivity of the materials.The recent phenomenal advancement in nano technology provides an opportunity for an appreciable enhancement in the thermal conductivity of the phase change materials.In order to explore the possibilities of using nano technology for various applications,a detailed parametric study is carried out,to analyse the heat transfer enhancement potential with the thermal conductivity of the conventional phase change materials and nano enhanced phase change materials under various flow conditions of the heat transfer fluid.Initially,the theoretical equation,used to determine the time for outward cylindrical solidification of the phase change material,is validated with the experimental results.It is inferred from the parametric studies,that for paraffinic phase change materials with air as the heat transfer fluid,the first step should be to increase the heat transfer coefficient to the maximum extent,before making any attempt to increase the thermal conductivity of the phase change materials,with the addition of nano particles.When water is used as the phase change material,the addition of nano particles is recommended to achieve better heat transfer,when a liquid is used as the heat transfer fluid.展开更多
This paper demonstrates the application of a design tool called BioTRIZ. Its developers claim that it can be used to access biological strategies for solving engineering problems. Our aim is to design a roof for hot c...This paper demonstrates the application of a design tool called BioTRIZ. Its developers claim that it can be used to access biological strategies for solving engineering problems. Our aim is to design a roof for hot climates that gets free cooling through radiant coupling with the sky. The insulation in a standard roof stops the sun and convection from warming the thermal mass. But it also restricts the mass's longwave view of the cool sky. Different solutions to this conflict are offered by BioTRIZ. The chosen solution is to replace the standard insulation component with an open cell honeycomb. The vertical cells would allow longwave radiation to pass, while arresting convection. The solutions offered by BioTRIZ's technological counterpart include no such changes in structure. It is estimated that the thermal mass in the biomimetic roof would remain on average 4.5℃ cooler than in a standard roof over a year in Riyadh, Saudi Arabia.展开更多
To find the deformation properties of chloride saline soil under the influence of a low temperature environment and different loads,two types of chloride saline soil were selected and their deformation process was tes...To find the deformation properties of chloride saline soil under the influence of a low temperature environment and different loads,two types of chloride saline soil were selected and their deformation process was tested in the laboratory and analyzed during the cooling process in the sensitive cryogenic temperature range.The research results show that high-chloride-salt saline soil underwent little volume change under the no-load condition during the cooling process.Under staticload and dynamic-load conditions,different degrees of settlement deformation occurred;throughout the entire cooling process,another chloride saline soil with a high proportion of sulfate salt underwent volume expansion under no-load and static-load conditions.Under the no-load condition,a certain degree of settlement deformation occurred.Deformation properties were evaluated at different time points during the cooling process for two kinds of chloride saline soil.Finally,deformation characteristics of chloride saline soil were analyzed from the perspective of salt type and crystallization variation under the action of a low-temperature environment and different loads.展开更多
Progressive collapse of building structures under blast and impact loads has attracted great attention all over the world. Progressive collapse analysis is essential for an economic and safe design of building structu...Progressive collapse of building structures under blast and impact loads has attracted great attention all over the world. Progressive collapse analysis is essential for an economic and safe design of building structures against progressive collapse to blast and impact loads. Because of the catastrophic nature of progressive collapse and the potentially high cost of constructing or retrofitting buildings to resist it, it is imperative that the progressive collapse analysis methods be reliable. For engineers, their methodology to carry out progressive collapse evaluation need not only be accurate and concise, but also be easily used and works fast. Thus, many researchers have been spending lots of effort in developing reliable, efficient and straightforward progressive collapse analysis methods recently. In the present paper, current progressive collapse analysis methods available in the literature are reviewed. Their suitability, applicability and reliability are discussed. Our recent proposed new method for progressive collapse analysis of reinforced concrete frames under blast loads is also introduced.展开更多
This paper reviews recent research on the demand flexibility of residential buildings in regard to definitions,flexible loads,and quantification methods.A systematic distinction of the terminology is made,including th...This paper reviews recent research on the demand flexibility of residential buildings in regard to definitions,flexible loads,and quantification methods.A systematic distinction of the terminology is made,including the demand flexibility,operation flexibility,and energy flexibility of buildings.A comprehensive definition of building demand flexibility is proposed based on an analysis of the existing definitions.Moreover,the flexibility capabilities and operation characteristics of the main residential flexible loads are summarized and compared.Models and evaluation indicators to quantify the flexibility of these flexible loads are reviewed and summarized.Current research gaps and challenges are identified and analyzed as well.The results indicate that previous studies have focused on the flexibility of central air conditioning,electric water heaters,wet appliances,refrigerators,and lighting,where the proportion of studies focusing on each of these subjects is 36.7%,25.7%,14.7%,9.2%,and 8.3%,respectively.These flexible loads are different in running modes,usage frequencies,seasons,and capabilities for shedding,shifting,and modulation,while their response characteristics are not yet clear.Furthermore,recommendations are given for the application of white-,black-,and grey-box models for modeling flexible loads in different situations.Numerous static flexibility evaluation indicators that are based on the aspects of power,temporality,energy,efficiency,economics,and the environment have been proposed in previous publications,but a consensus and standardized evaluation framework is lacking.This review can help readers better understand building demand flexibility and learn about the characteristics of different residential flexible loads,while also providing suggestions for future research on the modeling techniques and evaluation metrics of residential building demand flexibility.展开更多
The reliability of the numerical K ε model for determining wind pressure on building surfaces is evaluated. The solution algorithm is based on a body fitted non orthogonal curvilinear coordinate system and a st...The reliability of the numerical K ε model for determining wind pressure on building surfaces is evaluated. The solution algorithm is based on a body fitted non orthogonal curvilinear coordinate system and a staggered grid arrangement. The covariant velocity components are chosen as dependent variables. Convective fluxes are described by the Power Law Scheme. The grids are generated with an elliptic grid generator using control functions. The results compare favorably with those by Oxford wind tunnel measurements.展开更多
A building model with radiant cooling system was established and the cooling load, indoor temperature, surface temperature of the wails and other parameters in non-cooling and radiant cooling room were calculated by T...A building model with radiant cooling system was established and the cooling load, indoor temperature, surface temperature of the wails and other parameters in non-cooling and radiant cooling room were calculated by TRNSYS. The comparative analysis of the characteristics of attenuation and delay proves that the operation of radiant cooling system increases the degree of temperature attenuation of the room and reduces the inner surface temperature of the wall significantly, but has little effect on the attenuation coefficient and delay time of wall heat transfer. The simulation results also show that the inner surface temperature of the walls in the radiant cooling room is much lower than that in non-cooling room in the day with the maximum cooling load, which reduces the indoor operation temperature largely, and improves the thermal comfort. Finally, according to the analysis of indoor temperature of the rooms with different operation schedules of cooling system, it can be derived that the indoor mean temperature changes with the working time of radiant cooling system, and the operation schedule can be adjusted in practice according to the actual indoor temperature to achieve the integration of energy efficiency and thermal comfort.展开更多
Building emission reduction is an important way to achieve China’s carbon peaking and carbon neutrality goals.Aiming at the problem of low carbon economic operation of a photovoltaic energy storage building system,a ...Building emission reduction is an important way to achieve China’s carbon peaking and carbon neutrality goals.Aiming at the problem of low carbon economic operation of a photovoltaic energy storage building system,a multi-time scale optimal scheduling strategy based on model predictive control(MPC)is proposed under the consideration of load optimization.First,load optimization is achieved by controlling the charging time of electric vehicles as well as adjusting the air conditioning operation temperature,and the photovoltaic energy storage building system model is constructed to propose a day-ahead scheduling strategy with the lowest daily operation cost.Second,considering inter-day to intra-day source-load prediction error,an intraday rolling optimal scheduling strategy based on MPC is proposed that dynamically corrects the day-ahead dispatch results to stabilize system power fluctuations and promote photovoltaic consumption.Finally,taking an office building on a summer work day as an example,the effectiveness of the proposed scheduling strategy is verified.The results of the example show that the strategy reduces the total operating cost of the photovoltaic energy storage building system by 17.11%,improves the carbon emission reduction by 7.99%,and the photovoltaic consumption rate reaches 98.57%,improving the system’s low-carbon and economic performance.展开更多
The distributed energy system has achieved significant attention in respect of its application for singlebuilding cooling and heating.Researching on the life cycle environmental impact of distributed energy systems(DE...The distributed energy system has achieved significant attention in respect of its application for singlebuilding cooling and heating.Researching on the life cycle environmental impact of distributed energy systems(DES)is of great significance to encourage and guide the development of DES in China.However,the environmental performance of distributed energy systems in a building cooling and heating has not yet been carefully analyzed.In this study,based on the standards of ISO14040-2006 and ISO14044-2006,a life-cycle assessment(LCA)of a DES was conducted to quantify its environmental impact and a conventional energy system(CES)was used as the benchmark.GaBi 8 software was used for the LCA.And the Centre of Environmental Science(CML)method and Eco-indicator 99(EI 99)method were used for environmental impact assessment of midpoint and endpoint levels respectively.The results indicated that the DES showed a better life-cycle performance in the usage phase compared to the CES.The life-cycle performance of the DES was better than that of the CES both at the midpoint and endpoint levels in view of the whole lifespan.It is because the CES to DES indicator ratios for acidification potential,eutrophication potential,and global warming potential are 1.5,1.5,and 1.6,respectively at the midpoint level.And about the two types of impact indicators of ecosystem quality and human health at the endpoint level,the CES and DES ratios of the other indicators are greater than1 excepting the carcinogenicity and ozone depletion indicators.The human health threat for the DES was mainly caused by energy consumption during the usage phase.A sensitivity analysis showed that the climate change and inhalable inorganic matter varied by 1.3%and 6.1%as the electricity increased by 10%.When the natural gas increased by 10%,the climate change and inhalable inorganic matter increased by 6.3%and 3.4%,respectively.The human health threat and environmental damage caused by the DES could be significantly reduced by the optimization of natural gas and electricity consumption.展开更多
The main purpose of this paper is to investigate the effect of core eccentricity on the structural behavior of concrete tall buildings.Concrete buildings of 55 floors with plan dimensions 48.0×48.0 m2 were invest...The main purpose of this paper is to investigate the effect of core eccentricity on the structural behavior of concrete tall buildings.Concrete buildings of 55 floors with plan dimensions 48.0×48.0 m2 were investigated.Three cases of main core locations are studied:centric(A),eccentric by one sixth(B)and one third(C)of building width.The three-dimensional finite element method has been used in conducting structural analysis through ETABS software.Gravity and lateral(wind and seismic)loadings are applied to all building cases.It has been concluded that the core location is the prime parameter governing the structural behavior of tall buildings.Although the first two cases(A,B)have acceptable and similar structural behaviors conforming to code limits,in the third case(C),the building behavior came beyond code limits.The author introduced remedial action by adding two secondary cores in the opposite direction of the main core(C-R)to restore the building behavior to the code limits.The results of this action were satisfactory.展开更多
This paper presents an experimental study of a new designed Trombe wall in combination with solar chimney and water spraying system in a test room under Yazd(Iran) desert climate.The Trombe wall area is 50% of that of...This paper presents an experimental study of a new designed Trombe wall in combination with solar chimney and water spraying system in a test room under Yazd(Iran) desert climate.The Trombe wall area is 50% of that of the southern wall of the building that occupies less space and reduces the implementation costs. The new design of the channel has caused the absorber to receive the solar radiation from three directions. Based on the results, the optimum mass flow rate and the nozzle diameter of the water spraying system has been obtained 10 l/h and 30 μm, respectively. The results indicate that the water spraying system decreases indoor temperature and increases indoor relative humidity by about 8 ℃ and 17%, respectively. The most effect of outdoor relative humidity variation is on indoor relative humidity, rather than indoor temperature. When outdoor temperature increases, both indoor relative humidity and the difference between indoor and outdoor relative humidity decreases. The results also showed that theTrombe wall; Solar chimney; Water spraying system(2) Prediction of energy performance of residential buildings:A genetic programming approach, P67-74, by Mauro Castelli,Leonardo Trujillo, Leonardo Vanneschi, Ale觢 Popovic Abstract: Energy consumption has long been emphasized as an important policy issue in today's economies. In particular, the energy efficiency of residential buildings is considered a top priority of a country's energy policy. The paper proposes a genetic programming-based framework for estimating the energy performance of residential buildings. The objective is to build a model able to predict the heating load and the cooling load of residential buildings. An accurate prediction of these parameters facilitates a better control of energy consumption and, moreover, it helps choosing the energy supplier that better fits the energy needs,which is considered an important issue in the deregulated energy market. The proposed framework blends a recently developed version of genetic programming with a local search method and linear scaling. The resulting system enables us to build a model that produces an accurate estimation of both considered parameters. Extensive simulations on 768 diverse residential buildings confirm the suitability of the proposed method in predicting heating load and cooling load. In particular, the proposed method is more accurate than the existing state-of-the-art techniques.展开更多
In this paper, we study the influence ofeco materials for roof insulation and fiber-reinforced mortar coatings on cooling loads of a home in dry tropical climate. The walls of the house are made of cinderblock or late...In this paper, we study the influence ofeco materials for roof insulation and fiber-reinforced mortar coatings on cooling loads of a home in dry tropical climate. The walls of the house are made of cinderblock or laterite and the insulating material of a roof panel is made with lime (24%), cement (6%), water (50%) of vegetable fibers hibiscus sabdariffa (16%), tree widespread in Burkina Faso and sugar cane bagasse (4%). This panel roof insulation and the fiber-reinforced mortar were characterized at the Laboratory of Physics and Chemistry of the environment by the hot plate method. The building is modeled in TRNSYS using climate data from the city of Ouagadougou. The results obtained show that in the warmer months of the year, that is to say in March and April, the relative differences between heat gains the configurations "breeze block-coating mortar and roof not insulated" and "laterite- fiber-reinforced mortar coating and insulated roof' vary between 15.6% and 16.8%. The configuration "laterite-fiber-reinforced mortar coating and insulated roof allows a reduction of annual heat gains of 15.5% compared to the configuration "breeze block-coating mortar and roof not insulated".展开更多
The thermal properties of different clay samples obtained from locations in Akwa Ibom State, Nigeria were investigated and compared, and in order to establish their suitability as building material from energy conserv...The thermal properties of different clay samples obtained from locations in Akwa Ibom State, Nigeria were investigated and compared, and in order to establish their suitability as building material from energy conservation point of view. The results showed that stoneware clay has the highest solar radiation absorptivity of 22 32 m -1 while kaolin clay has the lowest radiation absoptivity of 14 46 m -1 A model for the prediction of temperature variation with thickness of the samples was developed. Results showed that kaolin would make the best choice for the design of a naturally cooled building.展开更多
In the quest to minimize energy waste,the energy performance of buildings(EPB)has been a focus because building appliances,such as heating,ventilation,and air conditioning,consume the highest energy.Therefore,effectiv...In the quest to minimize energy waste,the energy performance of buildings(EPB)has been a focus because building appliances,such as heating,ventilation,and air conditioning,consume the highest energy.Therefore,effective design and planning for estimating heating load(HL)and cooling load(CL)for energy saving have become paramount.In this vein,efforts have been made to predict the HL and CL using a univariate approach.However,this approach necessitates two models for learning HL and CL,requiring more computational time.Moreover,the one-dimensional(1D)convolutional neural network(CNN)has gained popularity due to its nominal computa-tional complexity,high performance,and low-cost hardware requirement.In this paper,we formulate the prediction as a multivariate regression problem in which the HL and CL are simultaneously predicted using the 1D CNN.Considering the building shape characteristics,one kernel size is adopted to create the receptive fields of the 1D CNN to extract the feature maps,a dense layer to interpret the maps,and an output layer with two neurons to predict the two real-valued responses,HL and CL.As the 1D data are not affected by excessive parameters,the pooling layer is not applied in this implementation.Besides,the use of pooling has been questioned by recent studies.The performance of the proposed model displays a comparative advantage over existing models in terms of the mean squared error(MSE).Thus,the proposed model is effective for EPB prediction because it reduces computational time and significantly lowers the MSE.展开更多
The cooling and heating load distribution of large area air-conditioned room such as “open” offices, shopping malls and waiting rooms is usually assumed to be even in air conditioning system design. However, it is n...The cooling and heating load distribution of large area air-conditioned room such as “open” offices, shopping malls and waiting rooms is usually assumed to be even in air conditioning system design. However, it is not the case in reality, and a low efficient air conditioning system results from this assumption. A simulation and analysis of the cooling load distribution of an office building in Hong Kong with TRANSYS software is provided in this paper. A typical office is divided into 13 zones for simulation, including external zone, medial zone and internal zone in the north, the south, the east and the west respectively and a central zone, instead of 4 directional zone. The result shows there is much cooling load difference between each zone, and more attention should be paid to uneven indoor cooling and heating load distribution to further guide the design.展开更多
Efficient Air Conditioning (A/C) system is the key to reducing energy consumption in building operation. In order to decrease the energy consumption in an A/C system, a method to calculate the optimal tube row number ...Efficient Air Conditioning (A/C) system is the key to reducing energy consumption in building operation. In order to decrease the energy consumption in an A/C system, a method to calculate the optimal tube row number of a direct expansion (DX) cooling coil for minimizing the entropy generation in the DX cooling which functioned as evaporator in the A/C system was developed. The optimal tube row numbers were determined based on the entropy generation minimization (EGM) approach. Parametric studies were conducted to demonstrate the application of the analytical calculation method. Optimal tube row number for different air mass flow rates, inlet air temperatures and sensible cooling loads were investigated. It was found that the optimal tube row number of a DX cooling coil was in the range of 5 - 9 under normal operating conditions. The optimal tube row number was less when the mass flow rate and inlet air temperature were increased. The tube row number increased when the sensible cooling load was increased. The exergy loss when using a non-optimal and optimal tube row numbers was compared to show the advantage of using the optimal tube row number. The decrease of exery loss ranged from around 24% to 70%. Therefore the new analytical method developed in this paper offers a good practice guide for the design of DX cooling coils for energy conservation.展开更多
Solar energy powered organic Rankine cycle vapor compression cycle(ORC-VCC)is a good alternative to convert solar heat into a cooling effect.In this study,an ORC-VCC system driven by solar energy combined with electri...Solar energy powered organic Rankine cycle vapor compression cycle(ORC-VCC)is a good alternative to convert solar heat into a cooling effect.In this study,an ORC-VCC system driven by solar energy combined with electric motor is proposed to ensure smooth operation under the conditions that solar radiation is unstable and discontinuous,and an office building located in Guangzhou,China is selected as a case study.The results show that beam solar radiation and generation temperature have considerable effects on the system performance.There is an optimal generation temperature at which the system achieves optimum performance.Also,as a key indicator,the cooling power per square meter collector should be considered in the hybrid solar cooling system in design process.Compared to the vapor compression cooling system,the hybrid cooling system can save almost 68.23%of electricity consumption.展开更多
文摘The district cooling system (DCS) with ice storage can reduce the peak electricity demand of the business district buildings it serves, improve system efficiency, and lower operational costs. This study utilizes a monitoring and control platform for DCS with ice storage to analyze historical parameter values related to system operation and executed operations. We assess the distribution of cooling loads among various devices within the DCS, identify operational characteristics of the system through correlation analysis and principal component analysis (PCA), and subsequently determine key parameters affecting changes in cooling loads. Accurate forecasting of cooling loads is crucial for determining optimal control strategies. The research process can be summarized briefly as follows: data preprocessing, parameter analysis, parameter selection, and validation of load forecasting performance. The study reveals that while individual devices in the system perform well, there is considerable room for improving overall system efficiency. Six principal components have been identified as input parameters for the cold load forecasting model, with each of these components having eigenvalues greater than 1 and contributing to an accumulated variance of 87.26%, and during the dimensionality reduction process, we obtained a confidence ellipse with a 95% confidence interval. Regarding cooling load forecasting, the Relative Absolute Error (RAE) value of the light gradient boosting machine (lightGBM) algorithm is 3.62%, Relative Root Mean Square Error (RRMSE) is 42.75%, and R-squared value (R<sup>2</sup>) is 92.96%, indicating superior forecasting performance compared to other commonly used cooling load forecasting algorithms. This research provides valuable insights and auxiliary guidance for data analysis and optimizing operations in practical engineering applications. .
基金The project partially supported by National Natural Science Foundation of China (No. 10275069)
文摘An actively water-cooled limiter has been designed for the long pulse operation of an HT-7 device, by adopting an integrated structure-doped graphite and a copper alloy heat sink with a super carbon sheet serving as a compliant layer between them. The behaviors of the integrated structure were evaluated in an electron beam facility under different heat loads and cooling conditions. The surface temperature and bulk temperature distribution were carefully measured by optical pyrometers and thermocouples under a steady state heat flux of 1 to 5 MW/m^2 and a water flow rate of 3 m^3/h, 4.5 m^3/h and 6 m^3/h, respectively. It was found that the surface temperature increased rapidly with the heat flux rising, but decreased only slightly with the water flow rate rising. The surface temperature reached approximately 1200℃ at 5 MW/m^2 of heat flux and 6 m^3/h of water flow. The primary experimental results indicate that the integrated design meets the requirements for the heat expelling capacity of the HT-7 device. A set of numerical simulations was also completed, whose outcome was in good accord with the experimental results.
文摘The prediction of the heating and cooling loads of a building is an essential aspect in studies involving the analysis of energy consumption in buildings. An accurate estimation of heating and cooling load leads to better management of energy related tasks and progressing towards an energy efficient building. With increasing global energy demands and buildings being major energy consuming entities, there is renewed interest in studying the energy performance of buildings. Alternative technologies like Artificial Intelligence (AI) techniques are being widely used in energy studies involving buildings. This paper presents a review of research in the area of forecasting the heating and cooling load of buildings using AI techniques. The results discussed in this paper demonstrate the use of AI techniques in the estimation of the thermal loads of buildings. An accurate prediction of the heating and cooling loads of buildings is necessary for forecasting the energy expenditure in buildings. It can also help in the design and construction of energy efficient buildings.
文摘The heat transfer performance of the phase change materials used in free cooling and air conditioning applications is low,due to the poor thermal conductivity of the materials.The recent phenomenal advancement in nano technology provides an opportunity for an appreciable enhancement in the thermal conductivity of the phase change materials.In order to explore the possibilities of using nano technology for various applications,a detailed parametric study is carried out,to analyse the heat transfer enhancement potential with the thermal conductivity of the conventional phase change materials and nano enhanced phase change materials under various flow conditions of the heat transfer fluid.Initially,the theoretical equation,used to determine the time for outward cylindrical solidification of the phase change material,is validated with the experimental results.It is inferred from the parametric studies,that for paraffinic phase change materials with air as the heat transfer fluid,the first step should be to increase the heat transfer coefficient to the maximum extent,before making any attempt to increase the thermal conductivity of the phase change materials,with the addition of nano particles.When water is used as the phase change material,the addition of nano particles is recommended to achieve better heat transfer,when a liquid is used as the heat transfer fluid.
文摘This paper demonstrates the application of a design tool called BioTRIZ. Its developers claim that it can be used to access biological strategies for solving engineering problems. Our aim is to design a roof for hot climates that gets free cooling through radiant coupling with the sky. The insulation in a standard roof stops the sun and convection from warming the thermal mass. But it also restricts the mass's longwave view of the cool sky. Different solutions to this conflict are offered by BioTRIZ. The chosen solution is to replace the standard insulation component with an open cell honeycomb. The vertical cells would allow longwave radiation to pass, while arresting convection. The solutions offered by BioTRIZ's technological counterpart include no such changes in structure. It is estimated that the thermal mass in the biomimetic roof would remain on average 4.5℃ cooler than in a standard roof over a year in Riyadh, Saudi Arabia.
基金supported by National Natural Science Foundation of China (No. 41501062)
文摘To find the deformation properties of chloride saline soil under the influence of a low temperature environment and different loads,two types of chloride saline soil were selected and their deformation process was tested in the laboratory and analyzed during the cooling process in the sensitive cryogenic temperature range.The research results show that high-chloride-salt saline soil underwent little volume change under the no-load condition during the cooling process.Under staticload and dynamic-load conditions,different degrees of settlement deformation occurred;throughout the entire cooling process,another chloride saline soil with a high proportion of sulfate salt underwent volume expansion under no-load and static-load conditions.Under the no-load condition,a certain degree of settlement deformation occurred.Deformation properties were evaluated at different time points during the cooling process for two kinds of chloride saline soil.Finally,deformation characteristics of chloride saline soil were analyzed from the perspective of salt type and crystallization variation under the action of a low-temperature environment and different loads.
基金Supported by National Natural Science Foundation of China(No.50638030and No.50528808)National Key Technologies R&D Program of China(No.2006BAJ13B02)
文摘Progressive collapse of building structures under blast and impact loads has attracted great attention all over the world. Progressive collapse analysis is essential for an economic and safe design of building structures against progressive collapse to blast and impact loads. Because of the catastrophic nature of progressive collapse and the potentially high cost of constructing or retrofitting buildings to resist it, it is imperative that the progressive collapse analysis methods be reliable. For engineers, their methodology to carry out progressive collapse evaluation need not only be accurate and concise, but also be easily used and works fast. Thus, many researchers have been spending lots of effort in developing reliable, efficient and straightforward progressive collapse analysis methods recently. In the present paper, current progressive collapse analysis methods available in the literature are reviewed. Their suitability, applicability and reliability are discussed. Our recent proposed new method for progressive collapse analysis of reinforced concrete frames under blast loads is also introduced.
基金the financial support of the Science and Technology Innovation Program of Hunan Province(2020RC5003)the research and application of key technologies for zero-energy buildings based on distributed energy storage and air conditioning demand response(2020-K-165)+1 种基金the Technology Innovation Program of Hunan Province(2017XK2015)the Technology Innovation Program of Hunan Province(2020RC2017)。
文摘This paper reviews recent research on the demand flexibility of residential buildings in regard to definitions,flexible loads,and quantification methods.A systematic distinction of the terminology is made,including the demand flexibility,operation flexibility,and energy flexibility of buildings.A comprehensive definition of building demand flexibility is proposed based on an analysis of the existing definitions.Moreover,the flexibility capabilities and operation characteristics of the main residential flexible loads are summarized and compared.Models and evaluation indicators to quantify the flexibility of these flexible loads are reviewed and summarized.Current research gaps and challenges are identified and analyzed as well.The results indicate that previous studies have focused on the flexibility of central air conditioning,electric water heaters,wet appliances,refrigerators,and lighting,where the proportion of studies focusing on each of these subjects is 36.7%,25.7%,14.7%,9.2%,and 8.3%,respectively.These flexible loads are different in running modes,usage frequencies,seasons,and capabilities for shedding,shifting,and modulation,while their response characteristics are not yet clear.Furthermore,recommendations are given for the application of white-,black-,and grey-box models for modeling flexible loads in different situations.Numerous static flexibility evaluation indicators that are based on the aspects of power,temporality,energy,efficiency,economics,and the environment have been proposed in previous publications,but a consensus and standardized evaluation framework is lacking.This review can help readers better understand building demand flexibility and learn about the characteristics of different residential flexible loads,while also providing suggestions for future research on the modeling techniques and evaluation metrics of residential building demand flexibility.
文摘The reliability of the numerical K ε model for determining wind pressure on building surfaces is evaluated. The solution algorithm is based on a body fitted non orthogonal curvilinear coordinate system and a staggered grid arrangement. The covariant velocity components are chosen as dependent variables. Convective fluxes are described by the Power Law Scheme. The grids are generated with an elliptic grid generator using control functions. The results compare favorably with those by Oxford wind tunnel measurements.
基金Project(2010DFA72740) supported by the International Science & Technology Cooperation Program of China
文摘A building model with radiant cooling system was established and the cooling load, indoor temperature, surface temperature of the wails and other parameters in non-cooling and radiant cooling room were calculated by TRNSYS. The comparative analysis of the characteristics of attenuation and delay proves that the operation of radiant cooling system increases the degree of temperature attenuation of the room and reduces the inner surface temperature of the wall significantly, but has little effect on the attenuation coefficient and delay time of wall heat transfer. The simulation results also show that the inner surface temperature of the walls in the radiant cooling room is much lower than that in non-cooling room in the day with the maximum cooling load, which reduces the indoor operation temperature largely, and improves the thermal comfort. Finally, according to the analysis of indoor temperature of the rooms with different operation schedules of cooling system, it can be derived that the indoor mean temperature changes with the working time of radiant cooling system, and the operation schedule can be adjusted in practice according to the actual indoor temperature to achieve the integration of energy efficiency and thermal comfort.
文摘Building emission reduction is an important way to achieve China’s carbon peaking and carbon neutrality goals.Aiming at the problem of low carbon economic operation of a photovoltaic energy storage building system,a multi-time scale optimal scheduling strategy based on model predictive control(MPC)is proposed under the consideration of load optimization.First,load optimization is achieved by controlling the charging time of electric vehicles as well as adjusting the air conditioning operation temperature,and the photovoltaic energy storage building system model is constructed to propose a day-ahead scheduling strategy with the lowest daily operation cost.Second,considering inter-day to intra-day source-load prediction error,an intraday rolling optimal scheduling strategy based on MPC is proposed that dynamically corrects the day-ahead dispatch results to stabilize system power fluctuations and promote photovoltaic consumption.Finally,taking an office building on a summer work day as an example,the effectiveness of the proposed scheduling strategy is verified.The results of the example show that the strategy reduces the total operating cost of the photovoltaic energy storage building system by 17.11%,improves the carbon emission reduction by 7.99%,and the photovoltaic consumption rate reaches 98.57%,improving the system’s low-carbon and economic performance.
基金Projects(51676209,22008265)supported by the National Natural Science Foundation of ChinaProjects(2020JJ6072,2021JJ50007)supported by the Hunan Province Natural Science Foundation,China。
文摘The distributed energy system has achieved significant attention in respect of its application for singlebuilding cooling and heating.Researching on the life cycle environmental impact of distributed energy systems(DES)is of great significance to encourage and guide the development of DES in China.However,the environmental performance of distributed energy systems in a building cooling and heating has not yet been carefully analyzed.In this study,based on the standards of ISO14040-2006 and ISO14044-2006,a life-cycle assessment(LCA)of a DES was conducted to quantify its environmental impact and a conventional energy system(CES)was used as the benchmark.GaBi 8 software was used for the LCA.And the Centre of Environmental Science(CML)method and Eco-indicator 99(EI 99)method were used for environmental impact assessment of midpoint and endpoint levels respectively.The results indicated that the DES showed a better life-cycle performance in the usage phase compared to the CES.The life-cycle performance of the DES was better than that of the CES both at the midpoint and endpoint levels in view of the whole lifespan.It is because the CES to DES indicator ratios for acidification potential,eutrophication potential,and global warming potential are 1.5,1.5,and 1.6,respectively at the midpoint level.And about the two types of impact indicators of ecosystem quality and human health at the endpoint level,the CES and DES ratios of the other indicators are greater than1 excepting the carcinogenicity and ozone depletion indicators.The human health threat for the DES was mainly caused by energy consumption during the usage phase.A sensitivity analysis showed that the climate change and inhalable inorganic matter varied by 1.3%and 6.1%as the electricity increased by 10%.When the natural gas increased by 10%,the climate change and inhalable inorganic matter increased by 6.3%and 3.4%,respectively.The human health threat and environmental damage caused by the DES could be significantly reduced by the optimization of natural gas and electricity consumption.
文摘The main purpose of this paper is to investigate the effect of core eccentricity on the structural behavior of concrete tall buildings.Concrete buildings of 55 floors with plan dimensions 48.0×48.0 m2 were investigated.Three cases of main core locations are studied:centric(A),eccentric by one sixth(B)and one third(C)of building width.The three-dimensional finite element method has been used in conducting structural analysis through ETABS software.Gravity and lateral(wind and seismic)loadings are applied to all building cases.It has been concluded that the core location is the prime parameter governing the structural behavior of tall buildings.Although the first two cases(A,B)have acceptable and similar structural behaviors conforming to code limits,in the third case(C),the building behavior came beyond code limits.The author introduced remedial action by adding two secondary cores in the opposite direction of the main core(C-R)to restore the building behavior to the code limits.The results of this action were satisfactory.
文摘This paper presents an experimental study of a new designed Trombe wall in combination with solar chimney and water spraying system in a test room under Yazd(Iran) desert climate.The Trombe wall area is 50% of that of the southern wall of the building that occupies less space and reduces the implementation costs. The new design of the channel has caused the absorber to receive the solar radiation from three directions. Based on the results, the optimum mass flow rate and the nozzle diameter of the water spraying system has been obtained 10 l/h and 30 μm, respectively. The results indicate that the water spraying system decreases indoor temperature and increases indoor relative humidity by about 8 ℃ and 17%, respectively. The most effect of outdoor relative humidity variation is on indoor relative humidity, rather than indoor temperature. When outdoor temperature increases, both indoor relative humidity and the difference between indoor and outdoor relative humidity decreases. The results also showed that theTrombe wall; Solar chimney; Water spraying system(2) Prediction of energy performance of residential buildings:A genetic programming approach, P67-74, by Mauro Castelli,Leonardo Trujillo, Leonardo Vanneschi, Ale觢 Popovic Abstract: Energy consumption has long been emphasized as an important policy issue in today's economies. In particular, the energy efficiency of residential buildings is considered a top priority of a country's energy policy. The paper proposes a genetic programming-based framework for estimating the energy performance of residential buildings. The objective is to build a model able to predict the heating load and the cooling load of residential buildings. An accurate prediction of these parameters facilitates a better control of energy consumption and, moreover, it helps choosing the energy supplier that better fits the energy needs,which is considered an important issue in the deregulated energy market. The proposed framework blends a recently developed version of genetic programming with a local search method and linear scaling. The resulting system enables us to build a model that produces an accurate estimation of both considered parameters. Extensive simulations on 768 diverse residential buildings confirm the suitability of the proposed method in predicting heating load and cooling load. In particular, the proposed method is more accurate than the existing state-of-the-art techniques.
文摘In this paper, we study the influence ofeco materials for roof insulation and fiber-reinforced mortar coatings on cooling loads of a home in dry tropical climate. The walls of the house are made of cinderblock or laterite and the insulating material of a roof panel is made with lime (24%), cement (6%), water (50%) of vegetable fibers hibiscus sabdariffa (16%), tree widespread in Burkina Faso and sugar cane bagasse (4%). This panel roof insulation and the fiber-reinforced mortar were characterized at the Laboratory of Physics and Chemistry of the environment by the hot plate method. The building is modeled in TRNSYS using climate data from the city of Ouagadougou. The results obtained show that in the warmer months of the year, that is to say in March and April, the relative differences between heat gains the configurations "breeze block-coating mortar and roof not insulated" and "laterite- fiber-reinforced mortar coating and insulated roof' vary between 15.6% and 16.8%. The configuration "laterite-fiber-reinforced mortar coating and insulated roof allows a reduction of annual heat gains of 15.5% compared to the configuration "breeze block-coating mortar and roof not insulated".
文摘The thermal properties of different clay samples obtained from locations in Akwa Ibom State, Nigeria were investigated and compared, and in order to establish their suitability as building material from energy conservation point of view. The results showed that stoneware clay has the highest solar radiation absorptivity of 22 32 m -1 while kaolin clay has the lowest radiation absoptivity of 14 46 m -1 A model for the prediction of temperature variation with thickness of the samples was developed. Results showed that kaolin would make the best choice for the design of a naturally cooled building.
基金supported in part by the Institute of Information and Communications Technology Planning and Evaluation(IITP)Grant by the Korean Government Ministry of Science and ICT(MSITArtificial Intelligence Innovation Hub)under Grant 2021-0-02068in part by the NationalResearch Foundation of Korea(NRF)Grant by theKorean Government(MSIT)under Grant NRF-2021R1I1A3060565.
文摘In the quest to minimize energy waste,the energy performance of buildings(EPB)has been a focus because building appliances,such as heating,ventilation,and air conditioning,consume the highest energy.Therefore,effective design and planning for estimating heating load(HL)and cooling load(CL)for energy saving have become paramount.In this vein,efforts have been made to predict the HL and CL using a univariate approach.However,this approach necessitates two models for learning HL and CL,requiring more computational time.Moreover,the one-dimensional(1D)convolutional neural network(CNN)has gained popularity due to its nominal computa-tional complexity,high performance,and low-cost hardware requirement.In this paper,we formulate the prediction as a multivariate regression problem in which the HL and CL are simultaneously predicted using the 1D CNN.Considering the building shape characteristics,one kernel size is adopted to create the receptive fields of the 1D CNN to extract the feature maps,a dense layer to interpret the maps,and an output layer with two neurons to predict the two real-valued responses,HL and CL.As the 1D data are not affected by excessive parameters,the pooling layer is not applied in this implementation.Besides,the use of pooling has been questioned by recent studies.The performance of the proposed model displays a comparative advantage over existing models in terms of the mean squared error(MSE).Thus,the proposed model is effective for EPB prediction because it reduces computational time and significantly lowers the MSE.
文摘The cooling and heating load distribution of large area air-conditioned room such as “open” offices, shopping malls and waiting rooms is usually assumed to be even in air conditioning system design. However, it is not the case in reality, and a low efficient air conditioning system results from this assumption. A simulation and analysis of the cooling load distribution of an office building in Hong Kong with TRANSYS software is provided in this paper. A typical office is divided into 13 zones for simulation, including external zone, medial zone and internal zone in the north, the south, the east and the west respectively and a central zone, instead of 4 directional zone. The result shows there is much cooling load difference between each zone, and more attention should be paid to uneven indoor cooling and heating load distribution to further guide the design.
文摘Efficient Air Conditioning (A/C) system is the key to reducing energy consumption in building operation. In order to decrease the energy consumption in an A/C system, a method to calculate the optimal tube row number of a direct expansion (DX) cooling coil for minimizing the entropy generation in the DX cooling which functioned as evaporator in the A/C system was developed. The optimal tube row numbers were determined based on the entropy generation minimization (EGM) approach. Parametric studies were conducted to demonstrate the application of the analytical calculation method. Optimal tube row number for different air mass flow rates, inlet air temperatures and sensible cooling loads were investigated. It was found that the optimal tube row number of a DX cooling coil was in the range of 5 - 9 under normal operating conditions. The optimal tube row number was less when the mass flow rate and inlet air temperature were increased. The tube row number increased when the sensible cooling load was increased. The exergy loss when using a non-optimal and optimal tube row numbers was compared to show the advantage of using the optimal tube row number. The decrease of exery loss ranged from around 24% to 70%. Therefore the new analytical method developed in this paper offers a good practice guide for the design of DX cooling coils for energy conservation.
基金This work was supported by the National Key Research and Development Program of China(No.2017YFB0903201)the Science and Technology Project of China Southern Power Grid(No.GDKJXM20172171).
文摘Solar energy powered organic Rankine cycle vapor compression cycle(ORC-VCC)is a good alternative to convert solar heat into a cooling effect.In this study,an ORC-VCC system driven by solar energy combined with electric motor is proposed to ensure smooth operation under the conditions that solar radiation is unstable and discontinuous,and an office building located in Guangzhou,China is selected as a case study.The results show that beam solar radiation and generation temperature have considerable effects on the system performance.There is an optimal generation temperature at which the system achieves optimum performance.Also,as a key indicator,the cooling power per square meter collector should be considered in the hybrid solar cooling system in design process.Compared to the vapor compression cooling system,the hybrid cooling system can save almost 68.23%of electricity consumption.