期刊文献+
共找到10篇文章
< 1 >
每页显示 20 50 100
Electrochromism-induced adaptive fresh air pre-handling system for building energy saving
1
作者 Dikai Xu Mingfeng Sheng +4 位作者 Xinpeng Zhao Hua Qian Wenqing Liang Xiaohong Zheng Dongliang Zhao 《Energy and Built Environment》 2024年第2期300-308,共9页
Building fresh air supply needs to meet certain regulations and fit people’s ever-growing indoor air quality de-mand.However,fresh air handling requires huge energy consumption that goes against the goal of net-zero ... Building fresh air supply needs to meet certain regulations and fit people’s ever-growing indoor air quality de-mand.However,fresh air handling requires huge energy consumption that goes against the goal of net-zero energy buildings.Thus,in this work,an adaptive fresh air pre-handling system is designed to reduce the cool-ing and heating loads of HVAC system.The sky-facing surface of the system uses electrochromic mechanism to manipulate the optical properties and thus make full use of solar energy(solar heating)and deep space cold source(radiative cooling)by switching between heating and cooling modes.In the cooling mode,the sky-facing surface shows a transmittance of down to zero,while the reflectance is high at 0.89 on average.In the heating mode,the electrochromic glass is highly transparent,allowing the sunlight to reach the solar heat absorber.To obtain the energy-saving potential under different climates,six cities were selected from various climate regions in China.Results show that the adaptive fresh air pre-handling system can be effective in up to 55.4%time of a year.The maximum energy-saving ratios for medium office,warehouse,and single-family house can reach up to 11.52%,26.62%,and 18.29%,respectively.In addition,the system shows multi-climate adaptability and broad application scenarios,making it a potential solution to building energy saving. 展开更多
关键词 Adaptive fresh air pre-handling ELECTROCHROMISM Radiative sky cooling Solar air heating Building energy saving
原文传递
Dynamic thermal performance of multilayer hollow clay walls filled with insulation materials:Toward energy saving in hot climates
2
作者 Yassine Chihab Mohammed Garoum Najma Laaroussi 《Energy and Built Environment》 2024年第1期70-80,共11页
This study examines the benefits of incorporating passive techniques into multilayer hollow clay brick walls to improve their dynamic thermal performance.The finite element approach was used to solve the incompressibl... This study examines the benefits of incorporating passive techniques into multilayer hollow clay brick walls to improve their dynamic thermal performance.The finite element approach was used to solve the incompressible Navier-Stokes and energy equations to analyze the dynamic thermal response of walls exposed to real thermal excitations of the Marrakesh climate.The results show that increasing the emissivity from 0.1 to 0.9 significantly increases the total heat load over 24 h.Furthermore,filling 100% of the cavities with insulation materials delayed the temperature peak by about 2.3 h and lowered the decrement factor by roughly 43%,with a value smaller than 0.07.In addition,it is demonstrated that the total thermal load is reduced by approximately 28% for improved wall configurations(100% insulation filling cavities)compared to traditional wall configurations(100% air filling cavities),which aids in improving building energy efficiency. 展开更多
关键词 Time lag Decrement factor Coupled heat transfer Analytical solution Hollow clay brick Insulation filling cavities energy savings in building
原文传递
Energy saving analysis of a transparent radiative cooling film for buildings with roof glazing 被引量:1
3
作者 Zhitong Yi Yingyan lv +4 位作者 Dikai Xu Jingtao Xu Hua Qian Dongliang Zhao Ronggui Yang 《Energy and Built Environment》 2021年第2期214-222,共9页
A transparent radiative cooling(T-RC)film with low transmittance in solar spectra and selectively high emissivity in the atmospheric window(8-13𝜇m)is applied on roof glazing for building energy saving.To evalu... A transparent radiative cooling(T-RC)film with low transmittance in solar spectra and selectively high emissivity in the atmospheric window(8-13𝜇m)is applied on roof glazing for building energy saving.To evaluate the per-formance of the T-RC film,two identical model boxes(1.0 m×0.6 m×1.2 m,L×W×H)were constructed and the inside air temperatures were measured in August in Ningbo,China.Results show that the maximum temperature difference between the two model boxes with and without the T-RC film was 21.6℃during the experiment.A whole building model was built in EnergyPlus for the model box.With a good agreement achieved between the calculation results and the measured temperature data,the experimentally validated EnergyPlus model was then extended to an 815.1 m^(2)exhibition building with roof glazing to analyze the annual air conditioning(AC)energy consumption.The results show that by incorporating both the T-RC film’s cooling benefit in summer and heating penalty in winter,the annual AC energy consumption of the exhibition building can be reduced by 40.9-63.4%,varying with different climate conditions. 展开更多
关键词 Transparent radiative cooling film Spectrum selective Window film Building energy saving
原文传递
Energy saving potential of a fresh air pre-cooling system using radiative sky cooling 被引量:3
4
作者 Dikai Xu Sebastien Boncoeur +3 位作者 Gang Tan Jingtao Xu Hua Qian Dongliang Zhao 《Building Simulation》 SCIE EI CSCD 2022年第2期167-178,共12页
To achieve required indoor air quality,fresh air supply in buildings should meet relevant standards and regulations.However,the handling of fresh air introduced a cooling load that takes up a large portion of building... To achieve required indoor air quality,fresh air supply in buildings should meet relevant standards and regulations.However,the handling of fresh air introduced a cooling load that takes up a large portion of building energy consumption,especially in tropical and subtropical areas.A proper way should be employed to reduce the cooling load of fresh air.Radiative sky cooling,which is the process that an object cools itself by emitting thermal radiation to outer space without any energy input,is a cost-effective and eco-friendly technology.In this work,a fresh air pre-cooling system using radiative sky cooling is proposed to reduce fresh air cooling load.The system,consisting of filters,a radiative air-cooling system,an air handling unit(AHU),fans,etc.,is installed on the rooftop of the modeled building.Six cities in low-latitude areas are selected and investigated.Results show that with the radiative air-cooling system installed,annual cooling energy consumption of the modeled building can be reduced by around 10%in most cities.For arid areas,e.g.,Abu Dhabi,the system has even better performance with 19.34%annual cooling energy saving. 展开更多
关键词 fresh air pre-cooling radiative sky cooling building energy saving
原文传递
Energy and comfort performance of occupant-centric air conditioning strategy in office buildings with personal comfort devices 被引量:2
5
作者 Jingsi Zhang Xiang Zhou +1 位作者 Song Lei Maohui Luo 《Building Simulation》 SCIE EI CSCD 2022年第5期899-911,共13页
The personal comfort system(PCS)aims to meet individual thermal comfort demands efficiently to achieve higher thermal comfort satisfaction while reducing air conditioning energy consumption.To date,many PCS devices ha... The personal comfort system(PCS)aims to meet individual thermal comfort demands efficiently to achieve higher thermal comfort satisfaction while reducing air conditioning energy consumption.To date,many PCS devices have been developed and evaluated from the perspective of thermal comfort.It will be useful for future PCS development if an approach to quantify the thermal comfort and energy performance of certain PCS devices and their combinations with consideration of user behaviors can be established.This study attempted to fill this gap by integrating thermal comfort experiments,occupancy simulations,usage behavior modeling,and building energy simulation technologies.First,human subject experiments were conducted to quantify the thermal comfort effects of the PCS.Then,the Markov chain model and conditional probability model were employed to describe the room occupancy and PCS usage behaviors.Finally,the extended comfort temperature range and user behavior models were imported into the building energy simulation tool to analyze the energy-saving potential of the PCS.The results show that the use of PCS can significantly improve occupants,thermal comfort and satisfaction rate under both warm and cool conditions.Using a cooling cushion and desktop fan can lift the upper limit of the comfortable temperature to 29.5℃while the heated cushion can extend the lower limit to 15℃.By increasing the air conditioning temperature setpoint by 2℃in summer and reducing by 2.5℃the heating temperature setpoint in winter,PCS devices can reduce heating and air conditioning energy consumption by 25%-40%while maintaining occupants’thermal comfort. 展开更多
关键词 thermal comfort personal comfort system occupant behavior building energy simulation building energy saving
原文传递
Applications of Low-Emissivity Hybrid Insulation in South Korea
6
作者 Young Cheol Kwon 《Journal of Power and Energy Engineering》 2016年第7期8-14,共7页
Low-Emissivity Hybrid Insulation has been developed in South Korea. It combines both resistive and reflective insulating principle. It is composed with many layers of reflective aluminum foils and honeycomb-structure ... Low-Emissivity Hybrid Insulation has been developed in South Korea. It combines both resistive and reflective insulating principle. It is composed with many layers of reflective aluminum foils and honeycomb-structure air cells with polyethylene foam. This paper introduces recent South Korean building insulation code and the applications of Low-Emissivity Hybrid Insulation to meet the code. 展开更多
关键词 Low-Emissivity Hybrid Insulation Building energy saving Building Insulation Code Insulation Application Overall Thermal Transmittance
下载PDF
Deep learning for estimating energy savings of early-stage facade design decisions
7
作者 B.Abediniangerabi A.Makhmalbaf M.Shahandashti 《Energy and AI》 2021年第3期91-103,共13页
The selection of high-performance building facade systems is essential to promote building energy efficiency.However,this selection is highly dependent on early-stage design decisions,which are extremely challenging c... The selection of high-performance building facade systems is essential to promote building energy efficiency.However,this selection is highly dependent on early-stage design decisions,which are extremely challenging considering numerous design parameters with early-stage uncertainties.This paper aims to evaluate the appli-cability of deep learning networks in estimating the energy savings of different facade alternatives in the early-stage design of buildings.The energy performance of two competing façade systems(i.e.,Ultra-High-Performance Fiber-Reinforced-Concrete and conventional panels)was estimated for different scenarios through building en-ergy simulations using EnergyPlusTM.Three deep learning networks were trained using the collected data from the simulation of fourteen buildings in fourteen different locations to estimate the heating,cooling,and total site energy savings.The accuracy of trained deep networks was compared with the accuracy of three common data-driven prediction models including,Gradient Boosting Machines,Random Forest,and Generalized Linear Regression.The results showed that the deep learning network trained to predict building total site energy savings had the highest accuracy among other models with a mean absolute error of 1.59 and a root mean square error of 3.48,followed by Gradient Boosting Machines,Random Forest,and last Generalized Linear Regression.Similarly,deep networks trained to predict building cooling and heating energy savings had the lowest mean average error of 0.20 and 1.17,respectively,compared to other predictive models.It is expected the decision support system developed based on this methodology helps architects and designers to quantify the energy savings of different facade systems in early stages of design decisions. 展开更多
关键词 Early-stage building facade design Building energy savings estimation Deep learning Deep neural networks
原文传递
Heating load reduction characteristics of passive solar buildings in Tibet,China 被引量:1
8
作者 Yanfeng Liu Zuoxiang Yu +1 位作者 Cong Song Dengjia Wang 《Building Simulation》 SCIE EI CSCD 2022年第6期975-994,共20页
China’s Tibet autonomous region has abundant solar energy resources,cold winters,and cool summers.These are ideal conditions for the application of passive solar heating methods.However,differences in climatic condit... China’s Tibet autonomous region has abundant solar energy resources,cold winters,and cool summers.These are ideal conditions for the application of passive solar heating methods.However,differences in climatic conditions and building types can significantly affect passive solar technology’s feasibility,which makes it challenging to promote passive solar buildings in Tibet.In this study,the suitability zone for passive solar technology is categorized based on the sub-zoning indicators for Tibet.By modeling between direct gain windows,Trombe walls,and attached sunspaces,the effect of indoor thermal environments and the capacity for heating load reduction is compared for different passive solar technologies.The climate-difference impact analysis shows that the I-B-1 zone is better suited for passive solar technology than other climate zones.More specifically,this zone has an average energy-saving rate difference of up to 28.61%compared to the II-A-1 zone.The analysis of the impact of building type differences indicates that residential buildings have higher Trombe wall-to-wall ratio limits and more significant potential for energy savings than office buildings.The study also clarifies the implications of Tibet’s climate conditions and building type differences on the effectiveness of passive solar technology.Moreover,it recommends appropriate passive solar technology adoption methods for every climate zone.This study can be used as a reference and engineering guide to improving the indoor thermal environment of Tibetan buildings,tailored to the highly variable local conditions. 展开更多
关键词 passive solar technology building energy saving indoor thermal environment numerical simulation
原文传递
The effects of cool materials,façade orientation,and morphological parameters on energy consumption at the residential neighborhood scale
9
作者 Fusuo Xu Dongdong Tian +1 位作者 Zhi Gao Jianshun Jensen Zhang 《Building Simulation》 SCIE EI 2024年第4期525-542,共18页
Building surface cool materials are novel materials that can reduce urban heat island intensity and decrease building energy consumption.This study investigated the impact of radiative properties of materials,faç... Building surface cool materials are novel materials that can reduce urban heat island intensity and decrease building energy consumption.This study investigated the impact of radiative properties of materials,façade orientation,and morphological parameters on energy consumption in six typical residential neighborhoods in Nanjing,China.The neighborhood energy consumption of 16 application schemes considering the façade orientation factor is compared to determine the best energy-saving scheme.Seasonal and annual energy-saving rates,savings in electricity costs,and the price ceiling for materials per unit area are analyzed.The results show that for low-rise buildings,using cool materials only on the roof can reduce the annual energy consumption by 1%.When cool or super cool materials are also used on the building façade,the annual energy saving rate can be up to 3.4%and 4.3%,respectively.Using cool materials on the south façade of buildings is not recommended due to significant heat loss in winter.Considering savings in electricity costs and the price ceiling for materials per unit area,the price of cool and super cool materials should be less than 3.0 and 3.7 RMB/m2,respectively,assuming a lifespan of eight years in Nanjing. 展开更多
关键词 cool materials building energy saving neighborhood morphology façade orientation
原文传递
Optical and thermal performance analysis of aerogel glazing technology in a commercial building of Hong Kong 被引量:1
10
作者 C.K.Leung L.Lu +2 位作者 Y.Liu H.S.Cheng Jeff H.Tse 《Energy and Built Environment》 2020年第2期215-223,共9页
Improving the thermal insulation of glazing units is a common strategy of reducing building energy use for spacing cooling.This paper newly examined the application of aerogel glazing technology in Hong Kong by the me... Improving the thermal insulation of glazing units is a common strategy of reducing building energy use for spacing cooling.This paper newly examined the application of aerogel glazing technology in Hong Kong by the means of laboratory testing and simulation.Nine prototypes of granular aerogel glazing were selected to examine their optical properties,and the measured optical properties of aerogel were used to calculate the total window thermal performance indices.A typical 40-story commercial office building was chosen for energy simulation to compare the thermal performance of aerogel glazing with different glazing technologies in Hong Kong.The results showed that aerogel glazing could achieve the promising reduction of window heat gain up to 57%and cooling energy up to 8.5%compared with double glazing.The heat insulation performance of aerogel glazing is even better than the double glazing with low-E coating in Hong Kong.Therefore,aerogel glazing can be a good alternative of glazing to comply with the existing local Overall Thermal Transfer Value(OTTV)requirement and to reduce the building energy use for space cooling in Hong Kong and other regions. 展开更多
关键词 Glazing technology Aerogel glazing Building energy saving
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部