期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
MODES COMPUTATION AND ANALYSIS FOR LONG MULTI-SPAN BUNDLE CONDUCTORS OF POWER TRANSMISSION LINES WITH GALLOPING CONTROL DEVICES 被引量:1
1
作者 Zhao Gaoyu He Zeng 《Acta Mechanica Solida Sinica》 SCIE EI 2002年第4期350-357,共8页
A new type of element which is suitable for solving the modes of thegalloping long multi-span bundle conductor structures is presented. The element is composed of allsub-conductor segments between two spacers. Based o... A new type of element which is suitable for solving the modes of thegalloping long multi-span bundle conductor structures is presented. The element is composed of allsub-conductor segments between two spacers. Based on the linearized governing differential equationsof the conductors, the mass matrix and stiffness matrix of the element in consideration of theconstrained relations imposed on the conductors by spacers are derived. The dynamic characteristicsof the galloping control devices can be directly added to the element. The modes for an actual powerline structure are computed by using the element formula and FEM procedures, where seven cases ofdifferent galloping control device allocations are considered. Compared with the measured data, themethod is shown to be reliable and effective. Analysis and discussions of the computational resultsare given. Some hints that are helpful to further investigation of galloping are also obtained . 展开更多
关键词 bundle conductors galloping control devices finite element method modes of free vibration
下载PDF
Corona Onset Voltage Gradient of Bundle Conductors for EHV/UHV AC Power Lines in Corona Cages Considering Altitude Correction 被引量:1
2
作者 Shilong Huang Yunpeng Liu +3 位作者 Shaoshuai Chen Daran Liu Wangling He Baoquan Wan 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2020年第3期693-703,共11页
The corona onset voltage gradient(COG)of conductors is a key parameter in the design of overhead transmission lines.The commonly used semi-empirical calculation formula proposed by Peek(1910s)at present can roughly es... The corona onset voltage gradient(COG)of conductors is a key parameter in the design of overhead transmission lines.The commonly used semi-empirical calculation formula proposed by Peek(1910s)at present can roughly estimate the COG of single conductors and is not applicable to large cross-section bundle conductors.In this paper,experiments are conducted to investigate the corona characteristics of a whole series of bundle conductors at different altitudes,and a prediction formula is proposed for the COG of large cross-section bundle conductors on AC transmission lines considering the altitude correction.The calculated values using the proposed prediction formula are compared with the experimental values of the COG in two cases:UHV eight-bundle conductors at an altitude of 19 m;500 kV UHV four-bundle conductors in Wuhan,Xining,Geermu,and Nachitai at four different altitudes.The results show that the use of the formula can predict the COG of bundle conductors with the radius of 1.34 cm to 1.995 cm and the number of subconductors of 4 to 12 at altitudes of 19 m to 4000 m above the mean sea level.The research findings can provide a reference for the design of EHV and UHV overhead transmission lines and even those in higher voltage levels. 展开更多
关键词 bundle conductor corona onset voltage gradient EHV and UHV transmission lines prediction formula
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部