Ensuring the health and safety of drinking water is crucial for both nations and their citizens.Since the 20th century,the disinfection of drinking water,effectively controlling pathogens in water sources,has become o...Ensuring the health and safety of drinking water is crucial for both nations and their citizens.Since the 20th century,the disinfection of drinking water,effectively controlling pathogens in water sources,has become one of the significant advances in public health.However,the disinfectants used in the process,such as chlorine and chlorine dioxide,react with natural organic matter in the water to produce disinfection by-products(DBPs).Most of these DBPs contain chlorine,and if the source water contains bromine or iodine,brominated or iodinated DBPs,collectively referred to as Halogenated disinfection byproducts(X-DBPs),are formed.Numerous studies have found that X-DBPs pose potential risks to human health and the environment,leading to widespread concern.Mass spectrometry has become an important means of discovering new types of X-DBPs.This paper focuses on the study of methods for analyzing X-DBPs in drinking water using mass spectrometry.展开更多
Tracing the contamination origins in water sources and identifying the impacts of natural and human processes are essential for ecological safety and public health.However,current analysis approaches are not ideal,as ...Tracing the contamination origins in water sources and identifying the impacts of natural and human processes are essential for ecological safety and public health.However,current analysis approaches are not ideal,as they tend to be laborious,time-consuming,or technically difficult.Disinfection byproducts(DBPs)are a family of well-known secondary pollutants formed by the reactions of chemical disinfectants with DBP precursors during water disinfection treatment.Since DBP precursors have various origins(e.g.,natural,domestic,industrial,and agricultural sources),and since the formation of DBPs from different precursors in the presence of specific disinfectants is distinctive,we argue that DBPs and DBP precursors can serve as alternative indicators to assess the contamination in water sources and identify pollution origins.After providing a retrospective of the origins of DBPs and DBP precursors,as well as the specific formation patterns of DBPs from different precursors,this article presents an overview of the impacts of various natural and anthropogenic factors on DBPs and DBP precursors in drinking water sources.In practice,the DBPs(i.e.,their concentration and speciation)originally present in source water and the DBP precursors determined using DBP formation potential tests—in which water samples are dosed with a stoichiometric excess of specific disinfectants in order to maximize DBP formation under certain reaction conditions—can be considered as alternative metrics.When jointly used with other water quality parameters(e.g.,dissolved organic carbon,dissolved organic nitrogen,fluorescence,and molecular weight distribution)and specific contaminants of emerging concern(e.g.,certain pharmaceuticals and personal care products),DBPs and DBP precursors in drinking water sources can provide a more comprehensive picture of water pollution for better managing water resources and ensuring human health.展开更多
BACKGROUND Aerosols containing disease-causing microorganisms are produced during oral diagnosis and treatment can cause secondary contamination.AIM To investigate the use of graphene material for air disinfection in ...BACKGROUND Aerosols containing disease-causing microorganisms are produced during oral diagnosis and treatment can cause secondary contamination.AIM To investigate the use of graphene material for air disinfection in dental clinics by leveraging its adsorption and antibacterial properties.METHODS Patients who received ultrasonic cleaning at our hospital from April 2023 to April 2024.They were randomly assigned to three groups(n=20 each):Graphene nanocomposite material suction group(Group A),ordinary filter suction group(Group B),and no air suction device group(Group C).The air quality and air colony count in the clinic rooms were assessed before,during,and after the procedure.Additionally,bacterial colony counts were obtained from the air outlets of the suction devices and the filter screens in Groups A and B.RESULTS Before ultrasonic cleaning,no significant differences in air quality PM2.5 and colony counts were observed among the three groups.However,significant differences in air quality PM2.5 and colony counts were noted among the three groups during ultrasonic cleaning and after ultrasonic treatment.Additionally,the number of colonies on the exhaust port of the suction device and the surface of the filter were significantly lower in Group A than in Group B(P=0.000 and P=0.000,respectively).CONCLUSION Graphene nanocomposites can effectively sterilize the air in dental clinics by exerting their antimicrobial effects and may be used to reduce secondary pollution.展开更多
This study aimed to examine the effect of different disinfection methods on the callus of Amorphophallus albus in the tissue culture and rapid propagation system.The calluses induced from buds of A.albus were disinfec...This study aimed to examine the effect of different disinfection methods on the callus of Amorphophallus albus in the tissue culture and rapid propagation system.The calluses induced from buds of A.albus were disinfected with benzalkonium bromide,mercury bichloride,sodium hypochlorite,and ethanol,respectively,for different time periods.The growth of calluses was compared between different treatments and observed in detail by dissection.The results showed that the disinfection with 0.1% mercury bichloride for 5 min and 75% ethanol for 5 s had mild effect on the callus,with the lowest browning rates of 16.32% and 15.46% and the lowest vitrification rates of 3.24% and 9.72%,respectively,after 20 d.The disinfection with benzalkonium bromide and sodium hypochlorite had strong effect on the callus cells,with the lowest browning rate of 50.69% and 25.12% and the lowest vitrification rates of 28.47% and 28.43%,respectively.The cytological observation result showed that the calluses disinfected with ethanol and mercury bichloride showcased compact structures,while those disinfected with sodium hypochlorite and benzalkonium bromide exhibited loose structures.To sum up,it is recommended that 75% ethanol or 0.1% mercury bichloride can be used for disinfection in the tissue culture and rapid propagation of A.albus,while the use of benzalkonium bromide and sodium hypochlorite should be avoided as much as possible.展开更多
Objective:To evaluate the application value of a refined quality control management model for a sterilization supply center.Methods:A retrospective analysis was conducted on the work situation of the sterilization sup...Objective:To evaluate the application value of a refined quality control management model for a sterilization supply center.Methods:A retrospective analysis was conducted on the work situation of the sterilization supply center from January 2021 to January 2023.The work situation before January 31,2022,was classified as the control group;a routine quality control management model was implemented,and the work situation after January 31,2022,was classified as the observation group.The quality of medical device management and department satisfaction between the two groups were compared.Results:The timely recovery and supply rate,classification and cleaning pass rate,disinfection pass rate,packaging pass rate,sterilization pass rate,and department satisfaction score in the observation group were all higher than those of the control group(P<0.05).Conclusion:Implementing a refined quality control management model in the sterilization supply center can improve the quality management level of medical devices and department satisfaction and is worthy of promotion.展开更多
Since the catalytic activity of most nanozymes is still far lower than the corresponding natural enzymes,there is urgent need to discover novel highly efficient enzyme-like materials.In this work,Co_(3)V_(2)O_(8)with ...Since the catalytic activity of most nanozymes is still far lower than the corresponding natural enzymes,there is urgent need to discover novel highly efficient enzyme-like materials.In this work,Co_(3)V_(2)O_(8)with hollow hexagonal prismatic pencil structures were prepared as novel artificial enzyme mimics.They were then decorated by photo-depositing Ag nanoparticles(Ag NPs)on the surface to further improve its catalytic activities.The Ag NPs decorated Co_(3)V_(2)O_(8)(ACVPs)showed both excellent oxidase-and peroxidase-like catalytic activities.They can oxidize the colorless 3,3’,5,5’-tetramethylbenzidine rapidly to induce a blue change.The enhanced enzyme mimetic activities can be attributed to the surface plasma resonance(SPR)effect of Ag NPs as well as the synergistic catalytic effect between Ag NPs and Co_(3)V_(2)O_(8),accelerating electron transfer and promoting the catalytic process.ACVPs were applied in constructing a colorimetric sensor,validating the occurrence of the Fenton reaction,and disinfection,presenting favorable catalytic performance.The enzyme-like catalytic mechanism was studied,indicating the chief role of⋅O_(2)-radicals in the catalytic process.This work not only discovers a novel functional material with double enzyme mimetic activity but also provides a new insight into exploiting artificial enzyme mimics with highly efficient catalytic ability.展开更多
BACKGROUND Pelvic floor dysfunction(PFD)is related to muscle fiber tearing during childbirth,negatively impacting postpartum quality of life of parturient.Appropriate and effective intervention is necessary to promote...BACKGROUND Pelvic floor dysfunction(PFD)is related to muscle fiber tearing during childbirth,negatively impacting postpartum quality of life of parturient.Appropriate and effective intervention is necessary to promote PFD recovery.AIM To analyze the use of hydrogen peroxide and silver ion disinfection for vaginal electrodes in conjunction with comprehensive rehabilitation therapy for postpartum women with PFD.METHODS A total of 59 women with PFD who were admitted to the hospital from May 2019 to July 2022 were divided into two groups:Control group(n=27)received comprehensive rehabilitation therapy and observation group(n=32)received intervention with pelvic floor biostimulation feedback instrument in addition to comprehensive rehabilitation therapy.The vaginal electrodes were disinfected with hydrogen peroxide and silver ion before treatment.Intervention for both groups was started 6 weeks postpartum,and rehabilitation lasted for 3 months.Pelvic floor muscle voltage,pelvic floor muscle strength,vaginal muscle voltage,vaginal muscle tone,pelvic floor function,quality of life,and incidence of postpartum PFD were compared between the two groups.RESULTS Before comprehensive rehabilitation treatment,basic data and pelvic floor function were not significantly different between the two groups.After treatment,the observation group showed significant improvements in the maximum voltage and average voltage of pelvic floor muscles,contraction time of type I and type II fibers,pelvic floor muscle strength,vaginal muscle tone,vaginal muscle voltage,and quality of life(GQOLI-74 reports),compared with the control group.The observation group had lower scores on the pelvic floor distress inventory(PFDI-20)and a lower incidence of postpartum PFD,indicating the effectiveness of the pelvic floor biostimulation feedback instrument in promoting the recovery of maternal pelvic floor function.CONCLUSION The combination of the pelvic floor biostimulation feedback instrument and comprehensive rehabilitation nursing can improve pelvic floor muscle strength,promote the recovery of vaginal muscle tone,and improve pelvic floor function and quality of life.The use of hydrogen peroxide and silver ion disinfectant demonstrated favorable antibacterial efficacy and is worthy of clinical application.展开更多
The UV irradiation is used for removing Antibiotic Resistant Bacteria(ARB)and Antibiotic Resistance Genes(ARG)from wastewater treatment.Bacteriophages are viruses that infect within bacteria,are recognized for bacteri...The UV irradiation is used for removing Antibiotic Resistant Bacteria(ARB)and Antibiotic Resistance Genes(ARG)from wastewater treatment.Bacteriophages are viruses that infect within bacteria,are recognized for bacterial control.The influence of some parameters in quantification and performance influencing of pathogen demobilization could be considered in disinfection of wastewater.The comparison of Polyvalent phage(NE1)versus Coliphage(NE4)in suppressing a bacterium Escherichia coli(NDM-1:b-lactam-resistant)with UV irradiation was observed the efficacy in reduction of cells in the disinfection and parameter process.The results with the effect of UV-C irradiation on NDM-1 infected with 1%of NE4 showed a decrease of cells from 8×10^(6)to 2×10^(5)in 60 min with UV-C dose.The NDM1(E.coli)was infected with 1%of NE4(Polyvalent Phage)under magnetic stirring for 1 h,the cells count was 8×10^(6).After 1 h in UV-C e×posure,the cells number reached 3×10^(5).The NDM1 that was e×posed in 1 h of UV-C irradiation and then was infected with 1%of NE4.Cells counting were done 24 h after this procedure.These cells were e×posed in UV-C and showed a reduction in the number of cells from 1×10^(8)to 4×10^(5)after 60 min.The results indicate that bacteriophages can mitigate bacteria species,and combined the conventional water disinfection technologies that can support the microbial safety control strategies.展开更多
Dissolved organic matter (DOM) has been identified as precursor for disinfection by-products (DBPs) formation during chlorination. Recently, it has been demonstrated that the characteristics of DOM influence the D...Dissolved organic matter (DOM) has been identified as precursor for disinfection by-products (DBPs) formation during chlorination. Recently, it has been demonstrated that the characteristics of DOM influence the DBPs formation mechanism. A study was, therefore, initiated to investigate the effects of DOM fractions on DBPs formation mechanism. In the chlorination process, organic acids are dominant precursors of total thihalomethanes (TTHM) because of the vc-o and unsaturated structures. Furthermore, the TTHM formation of organic acids was affected by pH more greatly. Based on the fluorescence spectroscopy analysis, DOM fractions contained several fluorescence substances. During chlorination, humic acid-like substances were found to exhibit high chlorine reactivity and hydrophobic organics decomposed to smaller molecules faster than hydrophilic organics even at lower chlorine dosages. Unlike hydrophobic fractions, hydrophilic organics showed no toxicity following chlorination, suggesting that the toxic structures in hydrophihc organics showed high chlorine reactivity during chlorination.展开更多
Objective To introduce a new sequential chlorination disinfection process in which short-term free chlorine and chloramine are sequentially added. Methods Pilot tests of this sequential chlorination were carried out i...Objective To introduce a new sequential chlorination disinfection process in which short-term free chlorine and chloramine are sequentially added. Methods Pilot tests of this sequential chlorination were carried out in a drinking water plant. Results The sequential chlorination disinfection process had the same or better efficiency on microbe (including virus) inactivation compared with the free chlorine disinfection process. There seemed to be some synergetic disinfection effect between free chlorine and monochloramine because they attacked different targets. The sequential chlorination disinfection process resulted in 35.7%-77.0% TTHM formation and 36.6%-54.8% THAA5 formation less than the free chlorination process. The poorer the water quality was, the more advantage the sequential chlorination disinfection had over the free chlorination. Conclusion This process takes advantages of free chlorine's quick inactivation of microorganisms and chloramine's low disinfection by-product (DBP) yield and long-term residual effect, allowing simultaneous control of microbes and DBPs in an effective and economic way.展开更多
The removal of disinfection by-products formation potential(DBPFP) in artificially intensified biological activated carbon(IBAC) process which is developed on the basis of traditional ozone granular activated carbon w...The removal of disinfection by-products formation potential(DBPFP) in artificially intensified biological activated carbon(IBAC) process which is developed on the basis of traditional ozone granular activated carbon was evaluated. By IBAC removals of 31% and 68% for THMFP and HAAFP were obtained respectively. Under identical conditions, the removals of the same substances were 4% and 32% respectively only by the granular activated carbon(GAC) process. Compared with GAC, the high removal rates of the two formed potential substances were due to the increasing of bioactivity of the media and the synergistic capabilities of biological degradation cooperating with activated carbon adsorption of organic compounds. A clear linear correlation(R 2=0.9562 and R 2=0.9007) between DOC HAAFP removal rate and Empty Bed Contact Time(EBCT) of IBAC process was observed, while that between THMFP removal rate and EBCT of GAC was R 2=0.9782. In addition certain linear correlations between THMFP, HAAFP and UV 254 (R 2=0.855 and R 2=0.7702) were found for the treated water. For IBAC process there are also more advantages such as long backwashing cycle time, low backwashing intensity and prolonging activated carbon lifetime and so on.展开更多
Practicability of method for the Hydra regeneration assay on the prescreening teratogenic potential of chlorinated drinking water disinfection by products was studied through both the assays of toxicity of adult ...Practicability of method for the Hydra regeneration assay on the prescreening teratogenic potential of chlorinated drinking water disinfection by products was studied through both the assays of toxicity of adult Hydra (T) and inhibition of the growth of regeneration Hydra (I) by using chloroform, dichloromethane and chloroacetic acid. The results showed that T 50 / I 50 ratios of chloroform and chloroacetic acid were 2 77 and 6 16 respectively, with teratogenic potential. T 50 / I 50 ratio of dichloromethane was 1.69, with weaker teratogenic potential. These experimental results indicated preliminarily that the Hydra regeneration assay has certainly applied value as a prescreening assay for developmental toxicity.展开更多
Background: Laboratory personnel is at risk of biological contamination leading to laboratory-acquired infections (LAIs). The use of disinfection products is essential in the prevention of these infections. This work ...Background: Laboratory personnel is at risk of biological contamination leading to laboratory-acquired infections (LAIs). The use of disinfection products is essential in the prevention of these infections. This work aimed to evaluate the effectiveness of antimicrobial agents used in disinfection in bacteriology laboratories in Togo. Methods: This was a cross-sectional study conducted from June to December 2021 in all bacteriology laboratories in Togo. Swabs taken before and after disinfection of surfaces and staff hands were immediately plated on agar media. Counting and identification of isolated colonies were done after 24 hours of incubation. The ANOVA test was used to compare calculated means, prevalence ratio (PR) and 95% confidence intervals (CI) to compare bacterial frequencies. Results: A total of 393 samples were taken, of which 41.2% were from hands. Before disinfection, surfaces were more contaminated than hands with respectively 40.4% and 29.6% (PR = 1.3;CI 95% = [0.9 - 1.9]). After surface disinfection with 0.5% of chlorine solution, bacterial elimination was total, but partial on hands washed with soap, with residual contamination of 3.7%. A total of 108 strains were isolated before disinfection of which Klebsiella spp. 38.9% and Staphylococcus spp. 25.0%;after disinfection 4 strains were isolated of which: Staphylococcus spp. 75.0% and Klebsiella spp. 25.0%. Conclusion: Surface disinfection was more effective than hand washing with soap and water. We recommend proper hand washing.展开更多
It is necessary to treat pathogen-infected water before its utilisation.Of conventionally used treatment methods,solar photocatalysis has gained considerable momentum owing to its operational simplicity and capacity t...It is necessary to treat pathogen-infected water before its utilisation.Of conventionally used treatment methods,solar photocatalysis has gained considerable momentum owing to its operational simplicity and capacity to use freely and abundantly available solar energy.This article systematically reviewed the disinfection of water with photocatalysis.It addressed the concerns of microbial infection of water and the fundamentals behind its treatment with photocatalysis.It presented an in-depth description of pathogenic deactivation with powerful reactive oxygen species.Special emphasis was given to process intensification as it is an attractive technique that provides multifunctionality and/or equipment miniaturisation.Solar reactor design regarding mobilised/immobilised photocatalysts and compound parabolic concentrators were elucidated.Finally,key parameters governing photoperformance,corresponding trade-offs,and the need for their optimisation were discussed.Overall,this article is a single point of reference for researchers,environmentalists,and industrialists who address the ever-severing challenge of providing clean water whilst also maintaining energy sustainability.展开更多
Objective Chlorination is often used to disinfect recreational water in large amusement parks;however,the health hazards of chlorination disinfection by-products(DBPs)to occupational populations are unknown.This study...Objective Chlorination is often used to disinfect recreational water in large amusement parks;however,the health hazards of chlorination disinfection by-products(DBPs)to occupational populations are unknown.This study aimed to assess the exposure status of chlorinated DBPs in recreational water and the health risks to employees of large amusement parks.Methods Exposure parameters of employees of three large amusement parks in Shanghai were investigated using a questionnaire.Seven typical chlorinated DBPs in recreational water and spray samples were quantified by gas chromatography,and the health risks to amusement park employees exposed to chlorinated DBPs were evaluated according to the WHO's risk assessment framework.Results Trichloroacetic acid,dibromochloromethane,bromodichloromethane,and dichloroacetic acid were detected predominantly in recreational water.The carcinogenic and non-carcinogenic risks of the five DBPs did not exceed the risk thresholds.In addition,the carcinogenic and non-carcinogenic risks of mixed exposure to DBPs were within the acceptable risk limits.Conclusion Typical DBPs were widely detected in recreational water collected from three large amusement parks in Shanghai;however,the health risks of DBPs and their mixtures were within acceptable limits.展开更多
The potential role of personal items in the transmission of pathogens is poorly understood. In this study, we cultured bacteria of public health importance found on wristbands, determined whether there is a correlatio...The potential role of personal items in the transmission of pathogens is poorly understood. In this study, we cultured bacteria of public health importance found on wristbands, determined whether there is a correlation between wristband material and prevalence, and tested three household disinfectants for efficacy in reducing bacteria on wristbands made of plastic, rubber, metal, and cloth, using standard microbiological assays. Total cultivable bacteria, Staphylococci, Enterobacteria (Escherichia coli), and Pseudomonas on 20 smartwatch wristbands were cultured from randomly recruited subjects. Nearly all wristbands (95%) were contaminated, with the highest average numbers of 3.46E+4 cfu/cm<sup>2</sup> and 1.52E+4 cfu/cm<sup>2</sup> on rubber and plastic bands respectively. Metallic gold and silver wristbands had zero to 18 cfu/cm<sup>2</sup>. While the high prevalence of Staphylococcus spp (85% of wristbands)—skin microbiota;was not unexpected, the occurrence of Pseudomonas spp (30%), and enteric bacteria (60%), even at relatively low numbers is of public health significance. Bacterial load on individual subjects varied remarkably with males and females harboring average total bacteria of 4.045 and 3.42 log<sub>10</sub>cfu/cm<sup>2</sup> of wristband, respectively. The most important predictor of wristband bacteria load was the texture of wristband material and activity (hygiene) of the subject at sampling time. Potential pathogens—Staphylococcus aureus (8143 cfu/cm<sup>2</sup>) and Pseudomonas spp. (1126 cfu/cm<sup>2</sup>) were most abundant on cloth and rubber wristbands, respectively, while the presence of the E. coli group was associated with animal handling activity by a veterinarian. Lysol Disinfectant Spray and 70% Ethanol were highly effective regardless of wristband material with >99.99% kill rate and a log cfu/cm<sup>2</sup> reduction of 3 - 4.0 and 3 - 4.5 respectively within 30 seconds. Apple Cider Vinegar (ACV) was not as potent. Only 2 - 3.5 log cfu/cm<sup>2</sup> drop was obtained after 120 seconds of exposure. Further susceptibility assays with standard reference bacteria showed that Lysol and 70% alcohol effectively killed > 99.99% (>8 log CFU drop) of Escherichia coli strain 7001, Staphylococcus aureus strain 6538, and Pseudomonas aeruginosa strain 10662 within 30 seconds of contact. Vinegar had a similar efficacy on the gram negatives but little or no effect on Staph aureus (only a 2-log CFU/ml reduction in 5 minutes!) The high prevalence of potential pathogens, some of which could be reservoirs of antibiotic resistance reveals a weak link in infection control and underscores the need for regular cleaning of personal and hand-held accessories with adequate considerations of their texture.展开更多
The high-active bacteria were screened from 8 dominant bacteria obtained from the natural water body,and then the bioaugmentation activated carbon was formed by hydraulic immobilization of the high-active bacteria. Pl...The high-active bacteria were screened from 8 dominant bacteria obtained from the natural water body,and then the bioaugmentation activated carbon was formed by hydraulic immobilization of the high-active bacteria. Plant-scale studies on removal characteristics of disinfection by-products formation potentials (DBPFP) by bioaugmentation activated carbon process were conducted for micro-polluted raw water treatment. The results show that the bioaugmentation activated carbon process has adopted better purification efficiency to THMFP and HAAFP than traditional biological activated carbon process,and that average removal efficiencies of THMFP and HAAFP can reach 35% and 39.7% during the test period,increasing by more than 10% compared with traditional biological activated carbon process. The removal efficiencies of THMFP and HAAFP are stable because of the biodegradation of the high-active bacteria and the adsorption of active carbon. The biodegradability of CHCl3 formation potential is better as compared with that of CHCl2Br and CHClBr2 formation potentials among THMFP,and high removal efficiency of CHCl3formation potential is obtained by bioaugmentation degradation of the high-active bacteria. The biodegradability of HAAFP is better in comparison with that of THMFP,and the chemical properties of HAAFP are propitious to adsorption of activated carbon. Thus,HAAFP is on predominance during the competitive removal process with THMFP.展开更多
Sodium hypochlorite has significant potential as a sanitation solution in hard-to-reach areas.Few studies have investigated the optimal electrolysis parameters for its production with volumes greater than 1o L.This st...Sodium hypochlorite has significant potential as a sanitation solution in hard-to-reach areas.Few studies have investigated the optimal electrolysis parameters for its production with volumes greater than 1o L.This study evaluated sodium hypochlorite production through electrolysis in a 22-L prototype and identified the optimal operating parameters.Tests were performed using graphite electrodes with areas of 68.4 cm^(2) at the laboratory scale and 1865.0 cm^(2) at the prototype scale.A design for experiments with different operating times,chloride concentrations,and electric current intensities was developed.The optimal operating time,sodium chloride concentration,and current intensity at the laboratory scale were 120 min,150 g of chloride per liter,and 3 A,respectively,leading to the production of 5.02 g/L of the disinfectant with an energy efficiency of 12.21 mg of Cl_(2) per kilojoule.At the prototype scale,the maximum sodium hypochlorite concentration of 3.99 g of chloride per liter was achieved with an operating time of 120 min,a sodium chloride concentration of 100 g of chloride per liter,and a current intensity of 70 A,reaching an energy efficiency of 42.56 mg of Cl_(2) per kilojoule.In addition,this study evaluated the influences of the chloride concentration,current intensity,and operating time on the production of sodium hypochlorite at the two scales,and formulated the equations showing the trends of sodium hypochlorite production and energy efficiency in the electrochemical systems.The 22-L prototype model for production of this oxidizing substance is promising for disinfection of large volumes of water in areas that are difficult to access.展开更多
Objective:To analyze the effect of sanitary wipes and medical alcohol+gauze disinfection methods on the management and use of medical equipment in hospitals.Methods:From February 2023 to August 2023,80 anorectal surge...Objective:To analyze the effect of sanitary wipes and medical alcohol+gauze disinfection methods on the management and use of medical equipment in hospitals.Methods:From February 2023 to August 2023,80 anorectal surgery medical instruments and equipment were randomly sampled as observation samples,and they were grouped using the random number table method(40 instruments in each group).One group was managed with sanitary wipes and medical alcohol+gauze disinfection method(observation group),and the other group was managed with medical alcohol+gauze disinfection method(control group).The degree of contamination on the surface of instruments and equipment and the staff satisfaction of both groups was noted and compared.Results:After cleaning and disinfection,the relative luminescence luminosity(RLU)value of the surface contamination of the sample instruments and equipment decreased significantly(P<0.05);and after cleaning and disinfection,the relative luminescence luminosity(RLU)of the observation group’s instruments and equipment decreased significantly,and the value was lower than that of the control group,(P<0.05);the results of the nursing job satisfaction questionnaire showed that the scores of each survey item in the observation group were higher than those in the control group,(P<0.05).Conclusion:Integrating sanitary wipes and medical alcohol+gauze disinfection method into the management and use of medical equipment not only improves the disinfection of medical instruments but also improves the job satisfaction of nursing staff.Therefore,this method should be popularized.展开更多
[Objective] The aim was to provide reference for the production technolo- gy of cold fresh chicken. [Method] Lactic acid was used as the disinfectant in cooling water, so as to study the effect of disinfection time on...[Objective] The aim was to provide reference for the production technolo- gy of cold fresh chicken. [Method] Lactic acid was used as the disinfectant in cooling water, so as to study the effect of disinfection time on the microbial content and quality of cold fresh chicken. [Result] With disinfection of 20 min, the removal rates of the total colonies, coliforms and moulds reached over 95%. As the disinfec- tion time was further extended, it had no significant effect on the removal effects of the microbial content and could affect the tenderness and color of cold fresh chick- en. [Cendusion] The study provides references for the design and optimization of the production process of cold fresh chicken.展开更多
文摘Ensuring the health and safety of drinking water is crucial for both nations and their citizens.Since the 20th century,the disinfection of drinking water,effectively controlling pathogens in water sources,has become one of the significant advances in public health.However,the disinfectants used in the process,such as chlorine and chlorine dioxide,react with natural organic matter in the water to produce disinfection by-products(DBPs).Most of these DBPs contain chlorine,and if the source water contains bromine or iodine,brominated or iodinated DBPs,collectively referred to as Halogenated disinfection byproducts(X-DBPs),are formed.Numerous studies have found that X-DBPs pose potential risks to human health and the environment,leading to widespread concern.Mass spectrometry has become an important means of discovering new types of X-DBPs.This paper focuses on the study of methods for analyzing X-DBPs in drinking water using mass spectrometry.
基金supported by the National Natural Science Foundation of China(52325001,52170009,and 52091542)the National Key Research and Development Program of China(2021YFC3200700)+3 种基金the Program of Shanghai Academic Research Leader,China(21XD1424000)the International Cooperation Project of Shanghai Science and Technology Commission(20230714100)the Key-Area Research and Development Program of Guangdong Province(2020B1111350001)Tongji University Youth 100 Program.
文摘Tracing the contamination origins in water sources and identifying the impacts of natural and human processes are essential for ecological safety and public health.However,current analysis approaches are not ideal,as they tend to be laborious,time-consuming,or technically difficult.Disinfection byproducts(DBPs)are a family of well-known secondary pollutants formed by the reactions of chemical disinfectants with DBP precursors during water disinfection treatment.Since DBP precursors have various origins(e.g.,natural,domestic,industrial,and agricultural sources),and since the formation of DBPs from different precursors in the presence of specific disinfectants is distinctive,we argue that DBPs and DBP precursors can serve as alternative indicators to assess the contamination in water sources and identify pollution origins.After providing a retrospective of the origins of DBPs and DBP precursors,as well as the specific formation patterns of DBPs from different precursors,this article presents an overview of the impacts of various natural and anthropogenic factors on DBPs and DBP precursors in drinking water sources.In practice,the DBPs(i.e.,their concentration and speciation)originally present in source water and the DBP precursors determined using DBP formation potential tests—in which water samples are dosed with a stoichiometric excess of specific disinfectants in order to maximize DBP formation under certain reaction conditions—can be considered as alternative metrics.When jointly used with other water quality parameters(e.g.,dissolved organic carbon,dissolved organic nitrogen,fluorescence,and molecular weight distribution)and specific contaminants of emerging concern(e.g.,certain pharmaceuticals and personal care products),DBPs and DBP precursors in drinking water sources can provide a more comprehensive picture of water pollution for better managing water resources and ensuring human health.
基金The Natural Science Research Project of Minhang District,No.2021MHZ070.
文摘BACKGROUND Aerosols containing disease-causing microorganisms are produced during oral diagnosis and treatment can cause secondary contamination.AIM To investigate the use of graphene material for air disinfection in dental clinics by leveraging its adsorption and antibacterial properties.METHODS Patients who received ultrasonic cleaning at our hospital from April 2023 to April 2024.They were randomly assigned to three groups(n=20 each):Graphene nanocomposite material suction group(Group A),ordinary filter suction group(Group B),and no air suction device group(Group C).The air quality and air colony count in the clinic rooms were assessed before,during,and after the procedure.Additionally,bacterial colony counts were obtained from the air outlets of the suction devices and the filter screens in Groups A and B.RESULTS Before ultrasonic cleaning,no significant differences in air quality PM2.5 and colony counts were observed among the three groups.However,significant differences in air quality PM2.5 and colony counts were noted among the three groups during ultrasonic cleaning and after ultrasonic treatment.Additionally,the number of colonies on the exhaust port of the suction device and the surface of the filter were significantly lower in Group A than in Group B(P=0.000 and P=0.000,respectively).CONCLUSION Graphene nanocomposites can effectively sterilize the air in dental clinics by exerting their antimicrobial effects and may be used to reduce secondary pollution.
文摘This study aimed to examine the effect of different disinfection methods on the callus of Amorphophallus albus in the tissue culture and rapid propagation system.The calluses induced from buds of A.albus were disinfected with benzalkonium bromide,mercury bichloride,sodium hypochlorite,and ethanol,respectively,for different time periods.The growth of calluses was compared between different treatments and observed in detail by dissection.The results showed that the disinfection with 0.1% mercury bichloride for 5 min and 75% ethanol for 5 s had mild effect on the callus,with the lowest browning rates of 16.32% and 15.46% and the lowest vitrification rates of 3.24% and 9.72%,respectively,after 20 d.The disinfection with benzalkonium bromide and sodium hypochlorite had strong effect on the callus cells,with the lowest browning rate of 50.69% and 25.12% and the lowest vitrification rates of 28.47% and 28.43%,respectively.The cytological observation result showed that the calluses disinfected with ethanol and mercury bichloride showcased compact structures,while those disinfected with sodium hypochlorite and benzalkonium bromide exhibited loose structures.To sum up,it is recommended that 75% ethanol or 0.1% mercury bichloride can be used for disinfection in the tissue culture and rapid propagation of A.albus,while the use of benzalkonium bromide and sodium hypochlorite should be avoided as much as possible.
文摘Objective:To evaluate the application value of a refined quality control management model for a sterilization supply center.Methods:A retrospective analysis was conducted on the work situation of the sterilization supply center from January 2021 to January 2023.The work situation before January 31,2022,was classified as the control group;a routine quality control management model was implemented,and the work situation after January 31,2022,was classified as the observation group.The quality of medical device management and department satisfaction between the two groups were compared.Results:The timely recovery and supply rate,classification and cleaning pass rate,disinfection pass rate,packaging pass rate,sterilization pass rate,and department satisfaction score in the observation group were all higher than those of the control group(P<0.05).Conclusion:Implementing a refined quality control management model in the sterilization supply center can improve the quality management level of medical devices and department satisfaction and is worthy of promotion.
基金supported by National Natural Science Foundation of China(52208272,41706080 and 51702328)the Basic Scientific Fund for National Public Research Institutes of China(2020S02 and 2019Y03)+3 种基金the Basic Frontier Science Research Program of Chinese Academy of Sciences(ZDBS-LY-DQC025)the Young Elite Scientists Sponsorship Program by CAST(No.YESS20210201)the Strategic Leading Science&Technology Program of the Chinese Academy of Sciences(XDA13040403)the Key Research and Development Program of Shandong Province(Major Scientific and Technological Innovation Project)(2019JZZY020711).
文摘Since the catalytic activity of most nanozymes is still far lower than the corresponding natural enzymes,there is urgent need to discover novel highly efficient enzyme-like materials.In this work,Co_(3)V_(2)O_(8)with hollow hexagonal prismatic pencil structures were prepared as novel artificial enzyme mimics.They were then decorated by photo-depositing Ag nanoparticles(Ag NPs)on the surface to further improve its catalytic activities.The Ag NPs decorated Co_(3)V_(2)O_(8)(ACVPs)showed both excellent oxidase-and peroxidase-like catalytic activities.They can oxidize the colorless 3,3’,5,5’-tetramethylbenzidine rapidly to induce a blue change.The enhanced enzyme mimetic activities can be attributed to the surface plasma resonance(SPR)effect of Ag NPs as well as the synergistic catalytic effect between Ag NPs and Co_(3)V_(2)O_(8),accelerating electron transfer and promoting the catalytic process.ACVPs were applied in constructing a colorimetric sensor,validating the occurrence of the Fenton reaction,and disinfection,presenting favorable catalytic performance.The enzyme-like catalytic mechanism was studied,indicating the chief role of⋅O_(2)-radicals in the catalytic process.This work not only discovers a novel functional material with double enzyme mimetic activity but also provides a new insight into exploiting artificial enzyme mimics with highly efficient catalytic ability.
文摘BACKGROUND Pelvic floor dysfunction(PFD)is related to muscle fiber tearing during childbirth,negatively impacting postpartum quality of life of parturient.Appropriate and effective intervention is necessary to promote PFD recovery.AIM To analyze the use of hydrogen peroxide and silver ion disinfection for vaginal electrodes in conjunction with comprehensive rehabilitation therapy for postpartum women with PFD.METHODS A total of 59 women with PFD who were admitted to the hospital from May 2019 to July 2022 were divided into two groups:Control group(n=27)received comprehensive rehabilitation therapy and observation group(n=32)received intervention with pelvic floor biostimulation feedback instrument in addition to comprehensive rehabilitation therapy.The vaginal electrodes were disinfected with hydrogen peroxide and silver ion before treatment.Intervention for both groups was started 6 weeks postpartum,and rehabilitation lasted for 3 months.Pelvic floor muscle voltage,pelvic floor muscle strength,vaginal muscle voltage,vaginal muscle tone,pelvic floor function,quality of life,and incidence of postpartum PFD were compared between the two groups.RESULTS Before comprehensive rehabilitation treatment,basic data and pelvic floor function were not significantly different between the two groups.After treatment,the observation group showed significant improvements in the maximum voltage and average voltage of pelvic floor muscles,contraction time of type I and type II fibers,pelvic floor muscle strength,vaginal muscle tone,vaginal muscle voltage,and quality of life(GQOLI-74 reports),compared with the control group.The observation group had lower scores on the pelvic floor distress inventory(PFDI-20)and a lower incidence of postpartum PFD,indicating the effectiveness of the pelvic floor biostimulation feedback instrument in promoting the recovery of maternal pelvic floor function.CONCLUSION The combination of the pelvic floor biostimulation feedback instrument and comprehensive rehabilitation nursing can improve pelvic floor muscle strength,promote the recovery of vaginal muscle tone,and improve pelvic floor function and quality of life.The use of hydrogen peroxide and silver ion disinfectant demonstrated favorable antibacterial efficacy and is worthy of clinical application.
基金Fundação de Amparo a Pesquisa do Estado de São Paulo(FAPESP)and the Conselho Nacional de Desenvolvimento Científico e Tecnológico(CNPq),São Paulo,Brazil for PhD scholarship(Process N°.141086/2015-7)financial support(Process No.870243/1997-7).
文摘The UV irradiation is used for removing Antibiotic Resistant Bacteria(ARB)and Antibiotic Resistance Genes(ARG)from wastewater treatment.Bacteriophages are viruses that infect within bacteria,are recognized for bacterial control.The influence of some parameters in quantification and performance influencing of pathogen demobilization could be considered in disinfection of wastewater.The comparison of Polyvalent phage(NE1)versus Coliphage(NE4)in suppressing a bacterium Escherichia coli(NDM-1:b-lactam-resistant)with UV irradiation was observed the efficacy in reduction of cells in the disinfection and parameter process.The results with the effect of UV-C irradiation on NDM-1 infected with 1%of NE4 showed a decrease of cells from 8×10^(6)to 2×10^(5)in 60 min with UV-C dose.The NDM1(E.coli)was infected with 1%of NE4(Polyvalent Phage)under magnetic stirring for 1 h,the cells count was 8×10^(6).After 1 h in UV-C e×posure,the cells number reached 3×10^(5).The NDM1 that was e×posed in 1 h of UV-C irradiation and then was infected with 1%of NE4.Cells counting were done 24 h after this procedure.These cells were e×posed in UV-C and showed a reduction in the number of cells from 1×10^(8)to 4×10^(5)after 60 min.The results indicate that bacteriophages can mitigate bacteria species,and combined the conventional water disinfection technologies that can support the microbial safety control strategies.
基金supported by the National Natural Science Foundation of China (No. 50538090)the Funds for Creative Research Groups of China (No. 50621804)the High-Tech Research and Development Program (863) of China (No. 2007AA06Z338).
文摘Dissolved organic matter (DOM) has been identified as precursor for disinfection by-products (DBPs) formation during chlorination. Recently, it has been demonstrated that the characteristics of DOM influence the DBPs formation mechanism. A study was, therefore, initiated to investigate the effects of DOM fractions on DBPs formation mechanism. In the chlorination process, organic acids are dominant precursors of total thihalomethanes (TTHM) because of the vc-o and unsaturated structures. Furthermore, the TTHM formation of organic acids was affected by pH more greatly. Based on the fluorescence spectroscopy analysis, DOM fractions contained several fluorescence substances. During chlorination, humic acid-like substances were found to exhibit high chlorine reactivity and hydrophobic organics decomposed to smaller molecules faster than hydrophilic organics even at lower chlorine dosages. Unlike hydrophobic fractions, hydrophilic organics showed no toxicity following chlorination, suggesting that the toxic structures in hydrophihc organics showed high chlorine reactivity during chlorination.
基金This work was sponsored by National Natural Science Fundation Committee (No. 50238020).
文摘Objective To introduce a new sequential chlorination disinfection process in which short-term free chlorine and chloramine are sequentially added. Methods Pilot tests of this sequential chlorination were carried out in a drinking water plant. Results The sequential chlorination disinfection process had the same or better efficiency on microbe (including virus) inactivation compared with the free chlorine disinfection process. There seemed to be some synergetic disinfection effect between free chlorine and monochloramine because they attacked different targets. The sequential chlorination disinfection process resulted in 35.7%-77.0% TTHM formation and 36.6%-54.8% THAA5 formation less than the free chlorination process. The poorer the water quality was, the more advantage the sequential chlorination disinfection had over the free chlorination. Conclusion This process takes advantages of free chlorine's quick inactivation of microorganisms and chloramine's low disinfection by-product (DBP) yield and long-term residual effect, allowing simultaneous control of microbes and DBPs in an effective and economic way.
文摘The removal of disinfection by-products formation potential(DBPFP) in artificially intensified biological activated carbon(IBAC) process which is developed on the basis of traditional ozone granular activated carbon was evaluated. By IBAC removals of 31% and 68% for THMFP and HAAFP were obtained respectively. Under identical conditions, the removals of the same substances were 4% and 32% respectively only by the granular activated carbon(GAC) process. Compared with GAC, the high removal rates of the two formed potential substances were due to the increasing of bioactivity of the media and the synergistic capabilities of biological degradation cooperating with activated carbon adsorption of organic compounds. A clear linear correlation(R 2=0.9562 and R 2=0.9007) between DOC HAAFP removal rate and Empty Bed Contact Time(EBCT) of IBAC process was observed, while that between THMFP removal rate and EBCT of GAC was R 2=0.9782. In addition certain linear correlations between THMFP, HAAFP and UV 254 (R 2=0.855 and R 2=0.7702) were found for the treated water. For IBAC process there are also more advantages such as long backwashing cycle time, low backwashing intensity and prolonging activated carbon lifetime and so on.
文摘Practicability of method for the Hydra regeneration assay on the prescreening teratogenic potential of chlorinated drinking water disinfection by products was studied through both the assays of toxicity of adult Hydra (T) and inhibition of the growth of regeneration Hydra (I) by using chloroform, dichloromethane and chloroacetic acid. The results showed that T 50 / I 50 ratios of chloroform and chloroacetic acid were 2 77 and 6 16 respectively, with teratogenic potential. T 50 / I 50 ratio of dichloromethane was 1.69, with weaker teratogenic potential. These experimental results indicated preliminarily that the Hydra regeneration assay has certainly applied value as a prescreening assay for developmental toxicity.
文摘Background: Laboratory personnel is at risk of biological contamination leading to laboratory-acquired infections (LAIs). The use of disinfection products is essential in the prevention of these infections. This work aimed to evaluate the effectiveness of antimicrobial agents used in disinfection in bacteriology laboratories in Togo. Methods: This was a cross-sectional study conducted from June to December 2021 in all bacteriology laboratories in Togo. Swabs taken before and after disinfection of surfaces and staff hands were immediately plated on agar media. Counting and identification of isolated colonies were done after 24 hours of incubation. The ANOVA test was used to compare calculated means, prevalence ratio (PR) and 95% confidence intervals (CI) to compare bacterial frequencies. Results: A total of 393 samples were taken, of which 41.2% were from hands. Before disinfection, surfaces were more contaminated than hands with respectively 40.4% and 29.6% (PR = 1.3;CI 95% = [0.9 - 1.9]). After surface disinfection with 0.5% of chlorine solution, bacterial elimination was total, but partial on hands washed with soap, with residual contamination of 3.7%. A total of 108 strains were isolated before disinfection of which Klebsiella spp. 38.9% and Staphylococcus spp. 25.0%;after disinfection 4 strains were isolated of which: Staphylococcus spp. 75.0% and Klebsiella spp. 25.0%. Conclusion: Surface disinfection was more effective than hand washing with soap and water. We recommend proper hand washing.
文摘It is necessary to treat pathogen-infected water before its utilisation.Of conventionally used treatment methods,solar photocatalysis has gained considerable momentum owing to its operational simplicity and capacity to use freely and abundantly available solar energy.This article systematically reviewed the disinfection of water with photocatalysis.It addressed the concerns of microbial infection of water and the fundamentals behind its treatment with photocatalysis.It presented an in-depth description of pathogenic deactivation with powerful reactive oxygen species.Special emphasis was given to process intensification as it is an attractive technique that provides multifunctionality and/or equipment miniaturisation.Solar reactor design regarding mobilised/immobilised photocatalysts and compound parabolic concentrators were elucidated.Finally,key parameters governing photoperformance,corresponding trade-offs,and the need for their optimisation were discussed.Overall,this article is a single point of reference for researchers,environmentalists,and industrialists who address the ever-severing challenge of providing clean water whilst also maintaining energy sustainability.
基金funded by the Foundation of State Environmental Protection Key Laboratory of Environmental Health Impact Assessment of Emerging Contaminants(Grant No.SEPKL-EHIAEC-202210)the Foundation of Shanghai Municipal Health Commission(Grant No.202240327)the Key Discipline Project of the Three-year Action Plan for Strengthening Public Health System Construction in Shanghai(2023-2025)(Grant No.GWVI-11.1-38)。
文摘Objective Chlorination is often used to disinfect recreational water in large amusement parks;however,the health hazards of chlorination disinfection by-products(DBPs)to occupational populations are unknown.This study aimed to assess the exposure status of chlorinated DBPs in recreational water and the health risks to employees of large amusement parks.Methods Exposure parameters of employees of three large amusement parks in Shanghai were investigated using a questionnaire.Seven typical chlorinated DBPs in recreational water and spray samples were quantified by gas chromatography,and the health risks to amusement park employees exposed to chlorinated DBPs were evaluated according to the WHO's risk assessment framework.Results Trichloroacetic acid,dibromochloromethane,bromodichloromethane,and dichloroacetic acid were detected predominantly in recreational water.The carcinogenic and non-carcinogenic risks of the five DBPs did not exceed the risk thresholds.In addition,the carcinogenic and non-carcinogenic risks of mixed exposure to DBPs were within the acceptable risk limits.Conclusion Typical DBPs were widely detected in recreational water collected from three large amusement parks in Shanghai;however,the health risks of DBPs and their mixtures were within acceptable limits.
文摘The potential role of personal items in the transmission of pathogens is poorly understood. In this study, we cultured bacteria of public health importance found on wristbands, determined whether there is a correlation between wristband material and prevalence, and tested three household disinfectants for efficacy in reducing bacteria on wristbands made of plastic, rubber, metal, and cloth, using standard microbiological assays. Total cultivable bacteria, Staphylococci, Enterobacteria (Escherichia coli), and Pseudomonas on 20 smartwatch wristbands were cultured from randomly recruited subjects. Nearly all wristbands (95%) were contaminated, with the highest average numbers of 3.46E+4 cfu/cm<sup>2</sup> and 1.52E+4 cfu/cm<sup>2</sup> on rubber and plastic bands respectively. Metallic gold and silver wristbands had zero to 18 cfu/cm<sup>2</sup>. While the high prevalence of Staphylococcus spp (85% of wristbands)—skin microbiota;was not unexpected, the occurrence of Pseudomonas spp (30%), and enteric bacteria (60%), even at relatively low numbers is of public health significance. Bacterial load on individual subjects varied remarkably with males and females harboring average total bacteria of 4.045 and 3.42 log<sub>10</sub>cfu/cm<sup>2</sup> of wristband, respectively. The most important predictor of wristband bacteria load was the texture of wristband material and activity (hygiene) of the subject at sampling time. Potential pathogens—Staphylococcus aureus (8143 cfu/cm<sup>2</sup>) and Pseudomonas spp. (1126 cfu/cm<sup>2</sup>) were most abundant on cloth and rubber wristbands, respectively, while the presence of the E. coli group was associated with animal handling activity by a veterinarian. Lysol Disinfectant Spray and 70% Ethanol were highly effective regardless of wristband material with >99.99% kill rate and a log cfu/cm<sup>2</sup> reduction of 3 - 4.0 and 3 - 4.5 respectively within 30 seconds. Apple Cider Vinegar (ACV) was not as potent. Only 2 - 3.5 log cfu/cm<sup>2</sup> drop was obtained after 120 seconds of exposure. Further susceptibility assays with standard reference bacteria showed that Lysol and 70% alcohol effectively killed > 99.99% (>8 log CFU drop) of Escherichia coli strain 7001, Staphylococcus aureus strain 6538, and Pseudomonas aeruginosa strain 10662 within 30 seconds of contact. Vinegar had a similar efficacy on the gram negatives but little or no effect on Staph aureus (only a 2-log CFU/ml reduction in 5 minutes!) The high prevalence of potential pathogens, some of which could be reservoirs of antibiotic resistance reveals a weak link in infection control and underscores the need for regular cleaning of personal and hand-held accessories with adequate considerations of their texture.
基金Sponsered by the National Natural Science Foundation of China (Grant No. 50678046)
文摘The high-active bacteria were screened from 8 dominant bacteria obtained from the natural water body,and then the bioaugmentation activated carbon was formed by hydraulic immobilization of the high-active bacteria. Plant-scale studies on removal characteristics of disinfection by-products formation potentials (DBPFP) by bioaugmentation activated carbon process were conducted for micro-polluted raw water treatment. The results show that the bioaugmentation activated carbon process has adopted better purification efficiency to THMFP and HAAFP than traditional biological activated carbon process,and that average removal efficiencies of THMFP and HAAFP can reach 35% and 39.7% during the test period,increasing by more than 10% compared with traditional biological activated carbon process. The removal efficiencies of THMFP and HAAFP are stable because of the biodegradation of the high-active bacteria and the adsorption of active carbon. The biodegradability of CHCl3 formation potential is better as compared with that of CHCl2Br and CHClBr2 formation potentials among THMFP,and high removal efficiency of CHCl3formation potential is obtained by bioaugmentation degradation of the high-active bacteria. The biodegradability of HAAFP is better in comparison with that of THMFP,and the chemical properties of HAAFP are propitious to adsorption of activated carbon. Thus,HAAFP is on predominance during the competitive removal process with THMFP.
基金supported by the America University,the Swiss Agency for Development and Cooperation,and the Central Technical Institute.
文摘Sodium hypochlorite has significant potential as a sanitation solution in hard-to-reach areas.Few studies have investigated the optimal electrolysis parameters for its production with volumes greater than 1o L.This study evaluated sodium hypochlorite production through electrolysis in a 22-L prototype and identified the optimal operating parameters.Tests were performed using graphite electrodes with areas of 68.4 cm^(2) at the laboratory scale and 1865.0 cm^(2) at the prototype scale.A design for experiments with different operating times,chloride concentrations,and electric current intensities was developed.The optimal operating time,sodium chloride concentration,and current intensity at the laboratory scale were 120 min,150 g of chloride per liter,and 3 A,respectively,leading to the production of 5.02 g/L of the disinfectant with an energy efficiency of 12.21 mg of Cl_(2) per kilojoule.At the prototype scale,the maximum sodium hypochlorite concentration of 3.99 g of chloride per liter was achieved with an operating time of 120 min,a sodium chloride concentration of 100 g of chloride per liter,and a current intensity of 70 A,reaching an energy efficiency of 42.56 mg of Cl_(2) per kilojoule.In addition,this study evaluated the influences of the chloride concentration,current intensity,and operating time on the production of sodium hypochlorite at the two scales,and formulated the equations showing the trends of sodium hypochlorite production and energy efficiency in the electrochemical systems.The 22-L prototype model for production of this oxidizing substance is promising for disinfection of large volumes of water in areas that are difficult to access.
文摘Objective:To analyze the effect of sanitary wipes and medical alcohol+gauze disinfection methods on the management and use of medical equipment in hospitals.Methods:From February 2023 to August 2023,80 anorectal surgery medical instruments and equipment were randomly sampled as observation samples,and they were grouped using the random number table method(40 instruments in each group).One group was managed with sanitary wipes and medical alcohol+gauze disinfection method(observation group),and the other group was managed with medical alcohol+gauze disinfection method(control group).The degree of contamination on the surface of instruments and equipment and the staff satisfaction of both groups was noted and compared.Results:After cleaning and disinfection,the relative luminescence luminosity(RLU)value of the surface contamination of the sample instruments and equipment decreased significantly(P<0.05);and after cleaning and disinfection,the relative luminescence luminosity(RLU)of the observation group’s instruments and equipment decreased significantly,and the value was lower than that of the control group,(P<0.05);the results of the nursing job satisfaction questionnaire showed that the scores of each survey item in the observation group were higher than those in the control group,(P<0.05).Conclusion:Integrating sanitary wipes and medical alcohol+gauze disinfection method into the management and use of medical equipment not only improves the disinfection of medical instruments but also improves the job satisfaction of nursing staff.Therefore,this method should be popularized.
基金Supported by the Jiangsu Agricultural Science and Technology Innovation Foundation(CX(15)1009)~~
文摘[Objective] The aim was to provide reference for the production technolo- gy of cold fresh chicken. [Method] Lactic acid was used as the disinfectant in cooling water, so as to study the effect of disinfection time on the microbial content and quality of cold fresh chicken. [Result] With disinfection of 20 min, the removal rates of the total colonies, coliforms and moulds reached over 95%. As the disinfec- tion time was further extended, it had no significant effect on the removal effects of the microbial content and could affect the tenderness and color of cold fresh chick- en. [Cendusion] The study provides references for the design and optimization of the production process of cold fresh chicken.