Through the development of marine energy,marine cables are the key equipment for transmission of electrical energy between surface platforms and underwater facilities.Fatigue failure is a critical failure mode of mari...Through the development of marine energy,marine cables are the key equipment for transmission of electrical energy between surface platforms and underwater facilities.Fatigue failure is a critical failure mode of marine cables.The bending performance of the cable conductor has a major influence on both bending and fatigue performances of the overall cable structure.To study the influence of different types of the conductor cross-section on the bending performances of marine cable conductors,three types of copper conductors with the same cross-sectional area,i.e.,noncompressed round,compressed round,and shaped wire conductors,were selected.The experimental results demonstrated that the cross-section type significantly affects the bending performances of copper conductors.In particular,the bending stiffness of the shaped wire conductor is the highest among the three conductor types.Four key evaluation parameters,i.e.,the bending stiffness,maximum bending moment,envelope area,and engineering critical slip point,were selected to compare and analyze the bending hysteresis curves of the three copper conductors.The differences in the key evaluation parameters were analyzed based on the structural dimensional parameters,processing methods,and classical bending stiffness theoretical models of the three copper conductor types.The results provide an important theoretical guidance for the structural design and engineering applications of marine cable conductors.展开更多
The central solenoid(CS)is one of the key components of the International Thermonuclear Experimental Reactor(ITER)tokamak and which is often considered as the heart of this fusion reactor.This solenoid will be bui...The central solenoid(CS)is one of the key components of the International Thermonuclear Experimental Reactor(ITER)tokamak and which is often considered as the heart of this fusion reactor.This solenoid will be built by using Nb3Sn cablein-conduit conductors(CICC),capable of generating a 13 T magnetic field.In order to assess the performance of the Nb3Sn CICC in nearly the ITER condition,many short samples have been evaluated at the SULTAN test facility(the background magnetic field is of 10.85 T with the uniform length of 400 mm at 1%homogeneity)in Centre de Recherches en Physique des Plasma(CRPP).It is found that the samples with pseudo-long twist pitch(including baseline specimens)show a significant degradation in the current-sharing temperature(Tcs),while the qualification tests of all short twist pitch(STP)samples,which show no degradation versus electromagnetic cycling,even exhibits an increase of Tcs.This behavior was perfectly reproduced in the coil experiments at the central solenoid model coil(CSMC)facility last year.In this paper,the complex structure of the Nb3Sn CICC would be simplified into a wire rope consisting of six petals and a cooling spiral.An analytical formula for the Tcs behavior as a function of the axial strain of the cable is presented.Based on this,the effects of twist pitch,axial and transverse stiffness,thermal mismatch,cycling number,magnetic distribution,etc.,on the axial strain are discussed systematically.The calculated Tcs behavior with cycle number show consistency with the previous experimental results qualitatively and quantitatively.Lastly,we focus on the relationship between Tcs and axial strain of the cable,and we conclude that the Tcs behavior caused by electromagnetic cycles is determined by the cable axial strain.Once the cable is in a compression situation,this compression strain and its accumulation would lead to the Tcs degradation.The experimental observation of the Tcs enhancement in the CS STP samples should be considered as a contribution of the shorter length of the high field zone in SULTAN and CSMC devices,as well as the tight cable structure.展开更多
In order to verify the feasibility of applying high-Jc Nb_(3)Sn strand in fusion magnet,a full-size cable-in-conduit conductor(CICC)with short twist pitch(STP)cable pattern was manufactured and tested in SULTAN facili...In order to verify the feasibility of applying high-Jc Nb_(3)Sn strand in fusion magnet,a full-size cable-in-conduit conductor(CICC)with short twist pitch(STP)cable pattern was manufactured and tested in SULTAN facility at SPC,Switzerland.Three levels of cyclic electromagnetic(EM)load were applied on the sample stepwise,no visible decrease of current sharing temperature(TcsT was observed until the EM load increased to 80 kA×10.8 T,after that the Tcs decreased dramatically with the EM cycles,which suggested that irreversible deformation,causing a change in the strain state,or even damage has occurred in the superconducting strands.For investigating the reason which caused the conductor performance degradation,the tested conductor was dissected for metallographic observation.Eight segments which subjected to different EM loads were extracted from one of the legs,the geometric feature changes of the cable cross-sections were analyzed and compared.A good correlation was found between the decrease of the Tcs and deformation of the cable cross section.A mass of cracks were found on the sub-elements of strands in the segment which subjected to highest EM load,but the amount of crack is much lower in other segments.Combining the analyses,it is speculated that the critical EM load which causes irreversible degradation is between 850 kN/m and 870 kN/m for this conductor.The results could be a reference in high-Jc Nb_(3)Sn CICC design.展开更多
Superconducting (SC) tokamak HT-7U has seven pairs of buslines connecting toroidal/poloidal coils and the current leads. These SC buslines (SCBLs) share a common cryostat and are made of the cable in conduit conductor...Superconducting (SC) tokamak HT-7U has seven pairs of buslines connecting toroidal/poloidal coils and the current leads. These SC buslines (SCBLs) share a common cryostat and are made of the cable in conduit conductors (CICCs) arranged as a decoupling configuration. In order to reduce the heat loads conducted from the seven current leads with a capacity of 15 kA during the magnets cooldown, the buslines with a much lower thermal conduction were employed in comparison with the current leads, and a special cooling loop was designed.展开更多
基金financially supported by the National Natural Science Foundation of China(Grant No.U1906233)the Key R&D Program of Shandong Province(Grant No.2019JZZY010801)+1 种基金the Development Projects in Key Areas of Guangdong Province(Grant No.2020B1111040002)the Fundamental Research Funds for the Central Universities(Grant Nos.DUT20ZD213 and DUT20LAB308)。
文摘Through the development of marine energy,marine cables are the key equipment for transmission of electrical energy between surface platforms and underwater facilities.Fatigue failure is a critical failure mode of marine cables.The bending performance of the cable conductor has a major influence on both bending and fatigue performances of the overall cable structure.To study the influence of different types of the conductor cross-section on the bending performances of marine cable conductors,three types of copper conductors with the same cross-sectional area,i.e.,noncompressed round,compressed round,and shaped wire conductors,were selected.The experimental results demonstrated that the cross-section type significantly affects the bending performances of copper conductors.In particular,the bending stiffness of the shaped wire conductor is the highest among the three conductor types.Four key evaluation parameters,i.e.,the bending stiffness,maximum bending moment,envelope area,and engineering critical slip point,were selected to compare and analyze the bending hysteresis curves of the three copper conductors.The differences in the key evaluation parameters were analyzed based on the structural dimensional parameters,processing methods,and classical bending stiffness theoretical models of the three copper conductor types.The results provide an important theoretical guidance for the structural design and engineering applications of marine cable conductors.
基金supported by the National Natural Science Foundation of China(Grant 11622217)the National Key Project of Scientific Instrument and Equipment Development(Grant 11327802)supported by the Fundamental Research Funds for the Central Universities(Grants lzujbky-2017-ot18,lzujbky-2017-k18)
文摘The central solenoid(CS)is one of the key components of the International Thermonuclear Experimental Reactor(ITER)tokamak and which is often considered as the heart of this fusion reactor.This solenoid will be built by using Nb3Sn cablein-conduit conductors(CICC),capable of generating a 13 T magnetic field.In order to assess the performance of the Nb3Sn CICC in nearly the ITER condition,many short samples have been evaluated at the SULTAN test facility(the background magnetic field is of 10.85 T with the uniform length of 400 mm at 1%homogeneity)in Centre de Recherches en Physique des Plasma(CRPP).It is found that the samples with pseudo-long twist pitch(including baseline specimens)show a significant degradation in the current-sharing temperature(Tcs),while the qualification tests of all short twist pitch(STP)samples,which show no degradation versus electromagnetic cycling,even exhibits an increase of Tcs.This behavior was perfectly reproduced in the coil experiments at the central solenoid model coil(CSMC)facility last year.In this paper,the complex structure of the Nb3Sn CICC would be simplified into a wire rope consisting of six petals and a cooling spiral.An analytical formula for the Tcs behavior as a function of the axial strain of the cable is presented.Based on this,the effects of twist pitch,axial and transverse stiffness,thermal mismatch,cycling number,magnetic distribution,etc.,on the axial strain are discussed systematically.The calculated Tcs behavior with cycle number show consistency with the previous experimental results qualitatively and quantitatively.Lastly,we focus on the relationship between Tcs and axial strain of the cable,and we conclude that the Tcs behavior caused by electromagnetic cycles is determined by the cable axial strain.Once the cable is in a compression situation,this compression strain and its accumulation would lead to the Tcs degradation.The experimental observation of the Tcs enhancement in the CS STP samples should be considered as a contribution of the shorter length of the high field zone in SULTAN and CSMC devices,as well as the tight cable structure.
基金supported by the National Key R&D Program of China(Grant No.2017YFE0301404)the Comprehensive Research Facility for Fusion Technology Program of China under Contract No.2018-000052-73-01-001228。
文摘In order to verify the feasibility of applying high-Jc Nb_(3)Sn strand in fusion magnet,a full-size cable-in-conduit conductor(CICC)with short twist pitch(STP)cable pattern was manufactured and tested in SULTAN facility at SPC,Switzerland.Three levels of cyclic electromagnetic(EM)load were applied on the sample stepwise,no visible decrease of current sharing temperature(TcsT was observed until the EM load increased to 80 kA×10.8 T,after that the Tcs decreased dramatically with the EM cycles,which suggested that irreversible deformation,causing a change in the strain state,or even damage has occurred in the superconducting strands.For investigating the reason which caused the conductor performance degradation,the tested conductor was dissected for metallographic observation.Eight segments which subjected to different EM loads were extracted from one of the legs,the geometric feature changes of the cable cross-sections were analyzed and compared.A good correlation was found between the decrease of the Tcs and deformation of the cable cross section.A mass of cracks were found on the sub-elements of strands in the segment which subjected to highest EM load,but the amount of crack is much lower in other segments.Combining the analyses,it is speculated that the critical EM load which causes irreversible degradation is between 850 kN/m and 870 kN/m for this conductor.The results could be a reference in high-Jc Nb_(3)Sn CICC design.
基金This work was supported by National Meg-Science Engineering Project of Chinese Government
文摘Superconducting (SC) tokamak HT-7U has seven pairs of buslines connecting toroidal/poloidal coils and the current leads. These SC buslines (SCBLs) share a common cryostat and are made of the cable in conduit conductors (CICCs) arranged as a decoupling configuration. In order to reduce the heat loads conducted from the seven current leads with a capacity of 15 kA during the magnets cooldown, the buslines with a much lower thermal conduction were employed in comparison with the current leads, and a special cooling loop was designed.