期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Theoretical analysis of transcranial Hall-effect stimulation based on passive cable model 被引量:8
1
作者 袁毅 李小俚 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第12期373-378,共6页
Transcranial Hall-effect stimulation(THS) is a new stimulation method in which an ultrasonic wave in a static magnetic field generates an electric field in an area of interest such as in the brain to modulate neuron... Transcranial Hall-effect stimulation(THS) is a new stimulation method in which an ultrasonic wave in a static magnetic field generates an electric field in an area of interest such as in the brain to modulate neuronal activities. However, the biophysical basis of simulating the neurons remains unknown. To address this problem, we perform a theoretical analysis based on a passive cable model to investigate the THS mechanism of neurons. Nerve tissues are conductive; an ultrasonic wave can move ions embedded in the tissue in a static magnetic field to generate an electric field(due to Lorentz force).In this study, a simulation model for an ultrasonically induced electric field in a static magnetic field is derived. Then,based on the passive cable model, the analytical solution for the voltage distribution in a nerve tissue is determined. The simulation results showthat THS can generate a voltage to stimulate neurons. Because the THS method possesses a higher spatial resolution and a deeper penetration depth, it shows promise as a tool for treating or rehabilitating neuropsychiatric disorders. 展开更多
关键词 HALL-EFFECT STIMULATION passive cable model neurons
下载PDF
Numerical Modeling of a Spherical Buoy Moored by a Cable in Three Dimensions 被引量:3
2
作者 ZHU Xiangqian YOO Wan-Suk 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2016年第3期588-597,共10页
Floating facilities have been studied based on the static analysis of mooring cables over the past decades. To analyze the floating system of a spherical buoy moored by a cable with a higher accuracy than before, the ... Floating facilities have been studied based on the static analysis of mooring cables over the past decades. To analyze the floating system of a spherical buoy moored by a cable with a higher accuracy than before, the dynamics of the cables are considered in the construction of the numerical modeling. The cable modeling is established based on a new element frame through which the hydrodynamic loads are expressed efficiently. The accuracy of the cable modeling is verified with an experiment that is conducted by a catenary chain moving in a water tank. In addition, the modeling of a spherical buoy is established with respect to a spherical coordinate in three dimensions, which can suffers the gravity, the variable buoyancy and Froude-Krylov loads. Finally, the numerical modeling for the system of a spherical buoy moored by a cable is established, and a virtual simulation is proceeded with the X- and Y-directional linear waves and the X-directional current. The comparison with the commercial simulation code Proteus DS indicates that the system is accurately analyzed by the numerical modeling. The tensions within the cable, the motions of the system, and the relationship between the motions and waves are illustrated according to the defined sea state. The dynamics of the cables should be considered in analyzing the floating system of a spherical buoy moored by a cable. 展开更多
关键词 numerical modeling dynamic simulation spherical buoy mooring cable dynamics of cable
下载PDF
A Geometrically Exact Formulation for Three-Dimensional Numerical Simulation of the Umbilical Cable in A Deep-Sea ROV System 被引量:3
3
作者 全伟才 张竺英 +2 位作者 张艾群 张奇峰 田宇 《China Ocean Engineering》 SCIE EI CSCD 2015年第2期223-240,共18页
This paper proposes a geometrically exact formulation for three-dimensional static and dynamic analyses of the umbilical cable in a deep-sea remotely operated vehicle(ROV) system. The presented formulation takes acc... This paper proposes a geometrically exact formulation for three-dimensional static and dynamic analyses of the umbilical cable in a deep-sea remotely operated vehicle(ROV) system. The presented formulation takes account of the geometric nonlinearities of large displacement, effects of axial load and bending stiffness for modeling of slack cables. The resulting nonlinear second-order governing equations are discretized spatially by the finite element method and solved temporally by the generalized-a implicit time integration algorithm, which is adapted to the case of varying coefficient matrices. The ability to consider three-dimensional union action of ocean current and ship heave motion upon the umbilical cable is the key feature of this analysis. The presented formulation is firstly validated, and then three numerical examples for the umbilical cable in a deep-sea ROV system are demonstrated and discussed, including the steady configurations only under the action of depth-dependent ocean current, the dynamic responses in the case of the only ship heave motion, and in the case of the combined action of the ship heave motion and ocean current. 展开更多
关键词 umbilical cable cable dynamics deep-sea ROV dynamic modeling
下载PDF
Statistical Characteristics of Partial Discharge Caused by Typical Defects in Cable Joint under Oscillating Voltage
4
作者 Guangmao Li Zuwei Luo +2 位作者 Jun Xiong Zucheng Huang Yajun Wang 《Journal of Energy and Power Engineering》 2015年第3期310-316,共7页
The oscillating voltage test is a nondestructive detection method for partial discharge of XLPE (cross linked polyethylene) cable and has been applied recently. This paper made three kinds of varying severity artifi... The oscillating voltage test is a nondestructive detection method for partial discharge of XLPE (cross linked polyethylene) cable and has been applied recently. This paper made three kinds of varying severity artificial defect models of cable joints in 10 kV XLPE cable. Oscillating voltage is applied to the model, by use of pulse current method to detect partial discharge signals. In order to study the statistical characteristics of partial discharge of cable joint under the oscillating voltage, three-dimensional statistical map has been made. The results show that for the same kind of defects, with the increases of the defect severity, the discharge interval extended, the magnitude and the number of partial discharge increase, for different kinds of defects, obvious differences exist among the maps, this may established a foundation for the further study of the partial discharge pattern recognition of XLPE cable under oscillating voltage. 展开更多
关键词 XLPE cable cable joint defect model partial discharge oscillating voltage three-dimensional statistical map.
下载PDF
THEORETICAL AND EXPERIMENTAL RESEARCH ON DYNAMIC BEHAVIOR OF GUYED MASTS UNDER WIND LOAD 被引量:3
5
作者 MaXing WangZhonggang +1 位作者 DengHongzhou WangZhaomin 《Acta Mechanica Solida Sinica》 SCIE EI 2004年第2期166-171,共6页
A frequency-domain algorithm is presented for the dynamic analysis of guyed masts. By introducing a four-degrees-of-freedom model of a suspended cable, guyed masts are simpli?ed as an equivalent cable-beam model. Th... A frequency-domain algorithm is presented for the dynamic analysis of guyed masts. By introducing a four-degrees-of-freedom model of a suspended cable, guyed masts are simpli?ed as an equivalent cable-beam model. Then, based on the discrete random vibration theory, recurrence formulas for the statistical moments of the wind-induced behavior of guyed masts are developed with the wind load treated as ?ltered white noise excitation. The dynamic analysis of a two-level guyed mast has been illustrated. Finally, results from a wind-tunnel experiment of guyed mast are used to testify the theory developed in this paper. 展开更多
关键词 guyed masts four-degrees-of-freedom cable model discrete random vibration wind tunnel experiment
下载PDF
Influence of motor cable on common-mode currents in an inverter-fed motor drive system 被引量:2
6
作者 Peng-kang XIE Jia-zheng LU +1 位作者 Guo-zhu CHEN Heng-lin CHEN 《Frontiers of Information Technology & Electronic Engineering》 SCIE EI CSCD 2018年第2期273-284,共12页
Induction motor drive systems fed by cables are widely used in industrial applications. However, high-frequency switching of power devices will cause common-mode(CM) voltages during operation, leading to serious CM ... Induction motor drive systems fed by cables are widely used in industrial applications. However, high-frequency switching of power devices will cause common-mode(CM) voltages during operation, leading to serious CM currents in the motor drive systems. CM currents through the cables and motors in the drive systems can cause electromagnetic interference(EMI) with the surrounding electronic equipment and shorten the life of induction motors. Therefore, it is necessary to analyze the CM currents in motor drive systems. In this paper, high-frequency models of unshielded and shielded power cables are formulated. The frequency-dependent effects and mutual inductances of the cables are taken into account. The power cable parameters are extracted by the finite element method and validated by measurements. High-frequency models of induction motors and inverters are introduced from existing works. The CM currents at the motor and inverter terminals are obtained, and the influence of the cable length and cable type on the CM currents is analyzed. There is a good agreement between the experimental results and the CM currents predicted by the proposed models. 展开更多
关键词 Common-mode currents cable model Motor drive system Parameter extraction
原文传递
上一页 1 下一页 到第