期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Plasma Density Measurements in Cable Gun Experiments with a Sensitive He-Ne Interferometer
1
作者 陈林 何安 +3 位作者 姜巍 徐敏 吴守东 李晔 《Plasma Science and Technology》 SCIE EI CAS CSCD 2007年第3期292-295,共4页
A time-resolved sensitive He-Ne laser interferometer without complicated active stabilization was built up and applied to low-density plasma measurements. A precision of about 0.2° in phase measurements was achie... A time-resolved sensitive He-Ne laser interferometer without complicated active stabilization was built up and applied to low-density plasma measurements. A precision of about 0.2° in phase measurements was achieved with a minimum line-integrated plasma density as low as 8.3× 10^13 cm^-2. With this interferometer, the characteristics of the plasma generated by a cable plasma gun was investigated systematically. The reproducibility, spatial and temporal distributions and the averaged injection velocity of the plasma are presented. In addition, the interaction of the plasma flow with a conductor was studied by placing a metal plate in the downstream of the cable gun. 展开更多
关键词 plasma opening switch INTERFEROMETER plasma density cable plasma gun
下载PDF
Characterization of Cable Gun Plasma with a Charge Collector Array
2
作者 陈玉兰 曾正中 +5 位作者 孙凤举 蒯斌 邱爱慈 尹佳辉 丛培天 梁天学 《Plasma Science and Technology》 SCIE EI CAS CSCD 2003年第3期1803-1810,共8页
The density, drift velocity and reproducibility of the plasma produced by a cable plasma gun array have been measured with a charge collector array. The plasma is used to prefill a coaxial plasma-opening switch with a... The density, drift velocity and reproducibility of the plasma produced by a cable plasma gun array have been measured with a charge collector array. The plasma is used to prefill a coaxial plasma-opening switch with a conducting time approaching 0.4 μs. The reproducibility of the plasma source in subsequent shots is better than 5%. Near the gun nozzle and the opposite electrode, the plasma density amounts to 1015cm-3, which is 2 times to 3 times that in the gap between the two coaxial electrodes. A plasma drift velocity of about 2.4 cm/μs is observed from the time of flight of the charged particles. Both plasma density and drift velocity increase almost linearly with the rise in charge voltage. 展开更多
关键词 low temperature plasma charge collector cable plasma gun
下载PDF
Study on Performance Parameters of the Plasma Source for a Short-Conduction-Time Plasma Opening Switch 被引量:1
3
作者 罗维熙 曾正中 +4 位作者 王亮平 雷天时 呼义翔 黄涛 孙铁平 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第12期1116-1120,共5页
Plasma source performance parameters, including plasma ejection density and velocity, greatly affect the operation of a short-conduction-time plasma opening switch (POS). In this paper, the plasma source used in the... Plasma source performance parameters, including plasma ejection density and velocity, greatly affect the operation of a short-conduction-time plasma opening switch (POS). In this paper, the plasma source used in the POS of Qiangguang I generator is chosen as the study object. At first the POS working process is analyzed. The result shows that the opening performance of the POS can be improved by increasing the plasma ejection velocity and decreasing the plasma density. The influence of the cable plasma gun structure and number on the plasma ejection parameters is experimentally investigated with two charge collectors. Finally a semi-empirical model is proposed to describe the experimental phenomenon. 展开更多
关键词 POS cable plasma gun plasma density and ejection velocity arc model
下载PDF
Plasma density evolution in plasma opening switch obtained by a time-resolved sensitive He-Ne interferometer
4
作者 CHEN Lin REN Jing +4 位作者 GUO Fan ZHOU LiangJi LI Ye HE An JIANG Wei 《Science China(Physics,Mechanics & Astronomy)》 SCIE EI CAS 2014年第3期442-446,共5页
To understand the formation process of vacuum gap in coaxial microsecond conduction time plasma opening switch(POS),we have made measurements of the line-integrated plasma density during switch operation using a time-... To understand the formation process of vacuum gap in coaxial microsecond conduction time plasma opening switch(POS),we have made measurements of the line-integrated plasma density during switch operation using a time-resolved sensitive He-Ne interferometer.The conduction current and conduction time in experiments are about 120 kA and 1 s,respectively.As a result,more than 85%of conduction current has been transferred to an inductive load with rise time of 130 ns.The radial dependence of the density is measured by changing the radial location of the line-of-sight for shots with the same nominal POS parameters.During the conduction phase,the line-integrated plasma density in POS increases at all radial locations over the gun-only case by further ionization of material injected from the guns.The current conduction is observed to cause a radial redistribution of the switch plasma.A vacuum gap forms rapidly in the plasma at 5.5 mm from the center conductor,which is consistent with the location where magnetic pressure is the largest,allowing current to be transferred from the POS to the load. 展开更多
关键词 plasma opening switch INTERFEROMETER plasma density cable plasma gun
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部