Effects of fundamental structure parameters on dynamic responses of submerged floating tunnel under hydrodynamic loads 被引量:9
1
作者 Xu Long Fei Ge Lei Wang Youshi Hong State Key Laboratory of Nonlinear Mechanics, Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190, China 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2009年第3期335-344,共10页
This paper investigates the effects of structure parameters on dynamic responses of submerged floating tunnel (SFT) under hydrodynamic loads. The structure parameters includes buoyancy-weight ratio (BWR), stiffnes... This paper investigates the effects of structure parameters on dynamic responses of submerged floating tunnel (SFT) under hydrodynamic loads. The structure parameters includes buoyancy-weight ratio (BWR), stiffness coefficients of the cable systems, tunnel net buoyancy and tunnel length. First, the importance of structural damp in relation to the dynamic responses of SPT is demonstrated and the mechanism of structural damp effect is discussed. Thereafter, the fundamental structure parameters are investigated through the analysis of SFT dynamic responses under hydrodynamic loads. The results indicate that the BWR of SFT is a key structure parameter. When BWR is 1.2, there is a remarkable trend change in the vertical dynamic response of SFT under hydrodynamic loads. The results also indicate that the ratio of the tunnel net buoyancy to the cable stiffness coefficient is not a characteristic factor affecting the dynamic responses of SFT under hydrodynamic loads. 展开更多
关键词 Submerged floating tunnel Structural dampBuoyancy-weight ratio cable stiffness coefficient Tunnel net buoyancy - Hydrodynamic load
下载PDF
Field Test of Optical and Electrical Fire Detectors in Simulated Fire Scenes in a Cable Tunnel 被引量:2
2
作者 Dian FAN Hongjun DING +1 位作者 Dorothy Y. WANG Desheng JIANG 《Photonic Sensors》 SCIE EI CAS 2014年第2期156-161,共6页
This paper presents the testing results of three types of fire detectors: electrical heat sensing cable, optical fiber Raman temperature sensing detector, and optical fiber Bragg grating (FBG) temperature sensing d... This paper presents the testing results of three types of fire detectors: electrical heat sensing cable, optical fiber Raman temperature sensing detector, and optical fiber Bragg grating (FBG) temperature sensing detector, in two simulated fire scenes in a cable tunnel. In the small-scale fire with limited thermal radiation and no flame, the fire alarm only comes from the heat sensors which directly contact with the heat source. In the large-scale fire with about 5 ℃/min temperature rising speed within a 3-m span, the fire alarm response time of the fiber Raman sensor and FBG sensors was about 30 seconds. The test results can be further used for formulating regulation for early fire detection in cable tunnels. 展开更多
关键词 Fire simulation fire detector cable tunnel response time