Objective To compare the clinical effects of treating cervical prolapse of intervertebral disc by using Solis cage, titanium cage and autogenous iliac crest graft (AICG) combined with titanium plate. Methods 64 cases ...Objective To compare the clinical effects of treating cervical prolapse of intervertebral disc by using Solis cage, titanium cage and autogenous iliac crest graft (AICG) combined with titanium plate. Methods 64 cases of cervical prolapse of intervertebral disc were analyzed retrospectively. All the patients were followed up for about one year. Group A is composed of 20 patients (30 intervertebral spaces) treated with microdiscectomy and Solis cage fusion; group B is composed of 21 patients(22 intervertebral spaces) treated with titanium cage and group C is involved of 23 patients(28 intervertebral spaces) which were dealt with AICG combined with titanium plate. The differences in the total X ray exposure time, time working on iliac bone, incidence of complications, fusion rate, incidence of JOA score recovery rate more than 50% and rehabilitation time of the three groups are analyzed. Results All indexes from group A and B were more satisfactory than those from group C (P<0.05). The statistic analysis results of the incidence of complications of cervical part, rehabilitation time in group A are 5.0±1.8, 5.1±1.2; and that is 14.3±2.6, 7.5 ±1.6 and 26.1±6.2, 8.6±2.3 in group B and group C respectively. There is significant difference between group A and group B on the incidence of complications of cervical part and rehabilitation time (P<0.05). Results of the incidence of JOA score recovery rate >50% in group A(95.8±3.2) was more satisfactory than that in group B(93.6±2.9), while there was no statistical difference between group A and group B (P>0.05). Conclusion The Solis cage is better in treating the cervical prolapse of intervertebral disc than other ways. Also, it makes the operation easier, rehabilitation time shorter, and it causes fewer complications.展开更多
To study the effect of titanium alloy cage on the treatment of the ischemic necrosis of femoral head in dog, the model of the ischemic necrosis of femoral head was made with the liquid nitrogen in 15 hybrid adult dogs...To study the effect of titanium alloy cage on the treatment of the ischemic necrosis of femoral head in dog, the model of the ischemic necrosis of femoral head was made with the liquid nitrogen in 15 hybrid adult dogs. The titanium alloy cage made of a hollow cylinder was driven into the subchondral bone of necrotic femoral head via central channel. The dogs were divided into 3 groups, each group was sacrificed 3, 6, 12 weeks after the operation respectively. No collapse of femoral head was observed after the operation. The position of the cages was good on radiograph. Microscopically, the cancellous bone of necrotic femoral head rebuilt gradually and grew into cage. After 12 weeks of creeping substitution, the cancellous bone filled up the hollow cavity and holes of the cages. It is concluded that the titanium alloy cage can provide structural support for the subchondral bone and prevent collapse and can be used for the treatment of the ischemic necrosis of femoral head.展开更多
In this study a lumbar spinal fusion animal model is established to assess the effect of spinal fusion cage,and explore theminimum area ratio of titanium cage section to vertebral section that ensures bone healing and...In this study a lumbar spinal fusion animal model is established to assess the effect of spinal fusion cage,and explore theminimum area ratio of titanium cage section to vertebral section that ensures bone healing and biomechanical property.Lumbarcorpectomy was conducted by posterolateral approach with titanium cage implantation combined with plate fixation.Titaniumcages with the same length but different diameters were used.After implantation of titanium cages,the progress of bone healingwas observed and the bone biomechanical properties were measured,including deformation and displacement in axial compression,flexion,extension,and lateral bending motion.The factors affecting the in vivo growth of spine supporting body wereanalyzed.The results show that the area ratio of titanium cage section to vertebral section should reach 1/2 to ensure the bonehealing,sufficient bone intensity and biomechanical properties.Some bone healing indicators,such as BMP,suggest that there isa relationship between the peak time and the peak value of bone formation and metabolism markers and the bone healing strength.展开更多
BACKGROUND Cervical degenerative disc(CDD)disease is a common type of spondylosis.Although anterior cervical discectomy and fusion(ACDF)is the preferred treatment for CDD disease,internal fixation with a titanium plat...BACKGROUND Cervical degenerative disc(CDD)disease is a common type of spondylosis.Although anterior cervical discectomy and fusion(ACDF)is the preferred treatment for CDD disease,internal fixation with a titanium plate may cause various complications.The invention of the ACDF with a self-locking fusion cage(ROI-C)has effectively decreased the incidence of postoperative complications.AIM To observe the outcomes of CDD disease treated by ACDF with a ROI-C.METHODS Ninety patients with CDD disease treated at our hospital from March 2019 to March 2021 were included.They were divided into two groups(control group and observation group,n=45 in each)using a random number table.Patients in the control group received ACDF plus internal fixation with a titanium plate.Those in the observation group received ACDF+ROI-C placement.The two groups of patients were compared in terms of surgical parameters,pain,cervical spine function,range of motion,and complications.RESULTS The two groups of patients showed no significant differences in surgical time,blood loss,drainage volume,and length of hospital stay(P>0.05).No significant differences in the visual analogue scale(VAS),Japanese Orthopedic Association(JOA),and neck disability index(NDI)scores were observed between the two groups before surgery(P>0.05).The VAS and NDI scores in the observation group were considerably lower than those in the control group after surgery;however,the JOA scores in the observation group were significantly higher than those in the control group(P<0.05).No significant differences were observed in cervical disc height and the range of motion of the superior or inferior adjacent vertebrae between the two groups before surgery(P>0.05).The disc height in the observation group was larger than that in the control group after surgery.The range of motion of both the superior and inferior adjacent vertebrae was significantly smaller in the observation group than in the control group(P<0.05).The incidence of complications was only 2.22% in the observation group compared to 15.56% in the control group,and the difference was statistically significant(P<0.05).CONCLUSION Cervical spine function restoration was better with ROI-C with internal fixation in ACDF than with conventional titanium plates in ACDF for CDD disease.展开更多
This work focuses on the influence of elastic modulus on biomechanical properties of lumbar interbody fusion cages by selecting two titanium alloys with different elastic modulus. They were made by a new β type alloy...This work focuses on the influence of elastic modulus on biomechanical properties of lumbar interbody fusion cages by selecting two titanium alloys with different elastic modulus. They were made by a new β type alloy with chemical composition of Ti-24Nb-4Zr-7.6Sn having low Young's modulus -50 GPa and by a conventional biomedical alloy Ti-6Al-4V having Young's modulus -110 GPa. The results showed that the designed cages with low modulus (LMC) and high modulus (HMC) can keep identical compression load -9.8 kN and endure fatigue cycles higher than 5× 10^6 without functional or mechanical failure under 2.0 kN axial compression. The anti-subsidence ability of both group cages were examined by axial compression of thoracic spine specimens (T9-T10) dissected freshly from the calf with averaged age of 6 months. The results showed that the LMC has better anti-subsidence ability than the HMC (p〈0.05). The above results suggest that the cage with low elastic modulus has great potential for clinical applications.展开更多
In this study,the characteristics of heat transfer on an unsteady magnetohydrodynamic(MHD)Casson nanofluid over an exponentially accelerated vertical porous plate with rotating effects were investigated.The flow was d...In this study,the characteristics of heat transfer on an unsteady magnetohydrodynamic(MHD)Casson nanofluid over an exponentially accelerated vertical porous plate with rotating effects were investigated.The flow was driven by the combined effects of the magnetic field,heat radiation,heat source/sink and chemical reaction.Copper oxide(CuO)and titanium oxide(TiO2)are acknowledged as nanoparticle materials.The nondimensional governing equations were subjected to the Laplace transformation technique to derive closed-form solutions.Graphical representations are provided to analyze how changes in physical parameters,such as the magnetic field,heat radiation,heat source/sink and chemical reaction,affect the velocity,temperature and concentration profiles.The computed values of skin friction,heat and mass transfer rates at the surface were tabulated for various sets of input parameters.It is perceived that there is a drop in temperature due to the rise in the heat source/sink and the Prandtl number.It should be noted that a boost in the thermal radiation parameter prompts an increase in temperature.An increase in the Prandtl number,heat source/sink parameter,time and a decrease in the thermal radiation parameter result in an increase in theNusselt number.The computed values of the skin friction,heat andmass transfer rates at the surface were tabulated for various values of the flow parameters.The present results were compared with those of previously published studies andwere found to be in excellent agreement.This research has practical applications in areas such as drug delivery,thermal medicine and cancer treatment.展开更多
In the present study, titanium plate was treated by a novel method of laser quenching, simultaneously combined with liquidnitrogen cryogenics(LQLNC). The microstructure and properties of the titanium plate after treat...In the present study, titanium plate was treated by a novel method of laser quenching, simultaneously combined with liquidnitrogen cryogenics(LQLNC). The microstructure and properties of the titanium plate after treatment were investigated by X-ray diffraction, scanning electron microscopy, energy dispersive spectrometry, Vickers hardness testing, and friction wear testing.The results show that the treated titanium plate is covered by a nitrided layer with a homogeneous thickness of about 60 μm,while the nitrided layer consists of Ti N and α-Ti phases. Compared to general laser quenching, the LQLNC treatment increases the hardness and wear resistance of the surface-modified layer of the titanium plate. As a result of grain refinement in the nitrided layer, the cracking induced by the rapid solidification of the conventional laser-quenching process has also been effectively solved.展开更多
Objective:To observe the clinical effect of anterior decompression and reconstruction using titanium mesh with locking plates in the treatment of cervical spondylotic myelopathy. Methods:One hundred and twenty patie...Objective:To observe the clinical effect of anterior decompression and reconstruction using titanium mesh with locking plates in the treatment of cervical spondylotic myelopathy. Methods:One hundred and twenty patients with cervical spondylotic myelopathy were treated by anterior decompression and reconstruction using titanium mesh with locking plates. There were 66 men and 54 women ranges in age from 37 to 72 Years(mean age, 58.3 years). The mean Japanese orthopedic surgery association(JOA) scale was 9.6 points before operation. Patients were followed up clinically and radiographically. Results:Having stood surgery well, the operation time ranged between 60-100 min and bleeding during operation ranged between 20-200 ml. There were no case of postoperative infection, recurrent laryngeal nerve palsy, or esophageal or tracheal laceration or rupture. The average follow-up period was 14.3 months(range, 12 to 24 months) in 96 who were followed up. At the last follow-up visit the mean JOA scale had improved to 14.4 points, reflecting an improvement of 4.8 points. The results were considered to be excellent in 87 patients, good in 25, fair in 6, and poor in 2. No hardware-related complications or adjacent segment degenerative changes were encountered during the follow-up periods. Stable bone union was observed in all cases and the average time required for fusion was 5.7 months. Conclusion:Titanium mesh filled with autologous bone graft can avoid the complications associated with harvesting bone from the iliac crest donor site. When combined with cervical anterior locking plate, it can obtain satisfatory clinical results for the treatment of cervical spondylotic myelopathy.展开更多
In this study,the interface characteristics of a direct hot rolling titanium-clad steel plate were analyzed, and the mechanism of interface cracking was explored. The detrimental effect from the formation of TiFe ,TiC...In this study,the interface characteristics of a direct hot rolling titanium-clad steel plate were analyzed, and the mechanism of interface cracking was explored. The detrimental effect from the formation of TiFe ,TiC,and a Si-enriched layer on the bonding strength was clarified, and an industrial-scaled titanium-clad steel plate with shear strength over 200 MPa was produced with a carefully set schedule accordingly. It was found that hot rolling titanium-clad steel plates had a flat interface without obvious cracks. In the rolling process,both Ti and Fe atoms interdiflhsed,but Fe difthsed much faster than Ti. The Fe-diffused area consisted of three regions. After a high temperature heat treatment, the diffusion depth of Fe and Ti elements increased significantly and evident Si segregation and TiFe layers were identified. Thermal cracking initiated in the Si segregation layer and then propagated along the TiFe layer and Fe-diffused layer on the titanium side.展开更多
Chest wall reconstruction after en-bloc tumor resection is very important to preserve functional mobility and to enhance the cosmetic effect. Because they are flexible and pliable, titanium plates are proposed to reco...Chest wall reconstruction after en-bloc tumor resection is very important to preserve functional mobility and to enhance the cosmetic effect. Because they are flexible and pliable, titanium plates are proposed to reconstruct the chest wall, even though such chest wall reconstruction has been performed in only a few cases worldwide. We present a case of a 49-year-old man with a chondrosarcoma arising from the left 1st rib, invading the manubrium, clavicle, 2nd and 3rd ribs, and the anterior segment of the left upper lobe. After wide resection, the chest wall was reconstructed using titanium rib plates and Marlex mesh- the Bovine pericardium sandwich type. The patient tolerated the pain well, and fourteen months after surgery, the chest wall was well preserved function mobility and improved pulmonary function test.展开更多
The scanning electron microscope (SEM) results of bone interface of titanium-coated 317L plate screw are reported in this article. 317L plate screw had a rough surface composed of sprayed pure titanium which formed a ...The scanning electron microscope (SEM) results of bone interface of titanium-coated 317L plate screw are reported in this article. 317L plate screw had a rough surface composed of sprayed pure titanium which formed a bone/metal interface in biointegration after implanted into the mandible of dog. Though a bone/metal interface in osseointegration was also formed on the surface of uncoated 317L plate screw after implantation, a smal1 space was seen between the bone and surface of the screw, indicating that the tissue compatibility of titanium-coated 317L plate screw may be better than that of the non-coated screw.展开更多
目的:颈前路减压融合术是治疗退行性颈椎病的经典手术方式,钉板的使用增加了融合率及稳定性的同时,间接导致了邻近椎体退变和术后吞咽困难的发生。文章通过Meta分析方法比较ROI-C^(TM)自锁系统和传统融合器联合钉板内固定治疗退行性颈...目的:颈前路减压融合术是治疗退行性颈椎病的经典手术方式,钉板的使用增加了融合率及稳定性的同时,间接导致了邻近椎体退变和术后吞咽困难的发生。文章通过Meta分析方法比较ROI-C^(TM)自锁系统和传统融合器联合钉板内固定治疗退行性颈椎病患者的临床结果和并发症情况,为颈前路减压融合术中内固定方式的选择提供循证学支持。方法:检索中国知网、万方、维普、PubMed、Cochrane Library、Web of Science和Embase数据库,检索关于颈前路减压融合术中应用ROI-C^(TM)自锁系统与融合器联合钉板内固定治疗退行性颈椎病的中英文文献。检索时间范围为各数据库建库至2023年7月。由2名研究者严格按照纳入与排除标准选择文献,采用Cochrane偏倚风险工具对随机对照试验进行质量评价,NOS量表对队列研究进行质量评价。采用RevMan 5.4软件进行Meta分析。结局指标包括手术时间、术中出血量、日本骨科协会(Japanese Orthopaedic Association Scores,JOA)评分、颈椎功能障碍指数、C_(2)-C_(7)Cobb角、融合率、邻近椎体退变发生率、融合器沉降率和吞咽困难发生率。结果:共纳入13项研究,其中回顾性队列研究11项,随机对照试验2项,共1136例患者,ROI-C组569例,融合器联合钉板组567例。Meta分析结果显示:ROI-C组与融合器联合钉板组在手术时间(MD=-15.52,95%CI:-18.62至-12.42,P<0.00001),术中出血量(MD=-24.53,95%CI:-32.46至-16.61,P<0.00001),术后邻近节段退变率(RR=0.40,95%CI:0.27-0.60,P<0.00001)和术后总吞咽困难发生率(RR=0.18,95%CI:0.13-0.26,P<0.00001)均具有显著性差异。两者在术后JOA评分、颈椎功能障碍指数、C_(2)-C_(7)Cobb角、融合率和融合器沉降率方面无显著性差异(P≥0.05)。结论:在颈椎前路减压融合术中应用ROI-C^(TM)自锁系统与传统融合器联合钉板内固定治疗退行性颈椎病均可达到满意的临床效果,ROI-C^(TM)自锁系统操作更加简单,相比融合器联合钉板内固定能明显减少手术时间及术中出血量,在减少术后吞咽困难及邻近节段退变发生率等方面具有明显优势,对于跳跃型颈椎病及邻椎病翻修患者,更加推荐使用ROI-C^(TM)自锁系统。但鉴于其可能存在较高的沉降率,对于多节段且合并融合器沉降高危因素如骨质疏松、椎体终板破损的退行性颈椎病患者,仍建议使用融合器联合钉板内固定。展开更多
文摘Objective To compare the clinical effects of treating cervical prolapse of intervertebral disc by using Solis cage, titanium cage and autogenous iliac crest graft (AICG) combined with titanium plate. Methods 64 cases of cervical prolapse of intervertebral disc were analyzed retrospectively. All the patients were followed up for about one year. Group A is composed of 20 patients (30 intervertebral spaces) treated with microdiscectomy and Solis cage fusion; group B is composed of 21 patients(22 intervertebral spaces) treated with titanium cage and group C is involved of 23 patients(28 intervertebral spaces) which were dealt with AICG combined with titanium plate. The differences in the total X ray exposure time, time working on iliac bone, incidence of complications, fusion rate, incidence of JOA score recovery rate more than 50% and rehabilitation time of the three groups are analyzed. Results All indexes from group A and B were more satisfactory than those from group C (P<0.05). The statistic analysis results of the incidence of complications of cervical part, rehabilitation time in group A are 5.0±1.8, 5.1±1.2; and that is 14.3±2.6, 7.5 ±1.6 and 26.1±6.2, 8.6±2.3 in group B and group C respectively. There is significant difference between group A and group B on the incidence of complications of cervical part and rehabilitation time (P<0.05). Results of the incidence of JOA score recovery rate >50% in group A(95.8±3.2) was more satisfactory than that in group B(93.6±2.9), while there was no statistical difference between group A and group B (P>0.05). Conclusion The Solis cage is better in treating the cervical prolapse of intervertebral disc than other ways. Also, it makes the operation easier, rehabilitation time shorter, and it causes fewer complications.
基金a grant from the National Natural Sciences Foundation of China (No. 30170945)
文摘To study the effect of titanium alloy cage on the treatment of the ischemic necrosis of femoral head in dog, the model of the ischemic necrosis of femoral head was made with the liquid nitrogen in 15 hybrid adult dogs. The titanium alloy cage made of a hollow cylinder was driven into the subchondral bone of necrotic femoral head via central channel. The dogs were divided into 3 groups, each group was sacrificed 3, 6, 12 weeks after the operation respectively. No collapse of femoral head was observed after the operation. The position of the cages was good on radiograph. Microscopically, the cancellous bone of necrotic femoral head rebuilt gradually and grew into cage. After 12 weeks of creeping substitution, the cancellous bone filled up the hollow cavity and holes of the cages. It is concluded that the titanium alloy cage can provide structural support for the subchondral bone and prevent collapse and can be used for the treatment of the ischemic necrosis of femoral head.
文摘In this study a lumbar spinal fusion animal model is established to assess the effect of spinal fusion cage,and explore theminimum area ratio of titanium cage section to vertebral section that ensures bone healing and biomechanical property.Lumbarcorpectomy was conducted by posterolateral approach with titanium cage implantation combined with plate fixation.Titaniumcages with the same length but different diameters were used.After implantation of titanium cages,the progress of bone healingwas observed and the bone biomechanical properties were measured,including deformation and displacement in axial compression,flexion,extension,and lateral bending motion.The factors affecting the in vivo growth of spine supporting body wereanalyzed.The results show that the area ratio of titanium cage section to vertebral section should reach 1/2 to ensure the bonehealing,sufficient bone intensity and biomechanical properties.Some bone healing indicators,such as BMP,suggest that there isa relationship between the peak time and the peak value of bone formation and metabolism markers and the bone healing strength.
文摘BACKGROUND Cervical degenerative disc(CDD)disease is a common type of spondylosis.Although anterior cervical discectomy and fusion(ACDF)is the preferred treatment for CDD disease,internal fixation with a titanium plate may cause various complications.The invention of the ACDF with a self-locking fusion cage(ROI-C)has effectively decreased the incidence of postoperative complications.AIM To observe the outcomes of CDD disease treated by ACDF with a ROI-C.METHODS Ninety patients with CDD disease treated at our hospital from March 2019 to March 2021 were included.They were divided into two groups(control group and observation group,n=45 in each)using a random number table.Patients in the control group received ACDF plus internal fixation with a titanium plate.Those in the observation group received ACDF+ROI-C placement.The two groups of patients were compared in terms of surgical parameters,pain,cervical spine function,range of motion,and complications.RESULTS The two groups of patients showed no significant differences in surgical time,blood loss,drainage volume,and length of hospital stay(P>0.05).No significant differences in the visual analogue scale(VAS),Japanese Orthopedic Association(JOA),and neck disability index(NDI)scores were observed between the two groups before surgery(P>0.05).The VAS and NDI scores in the observation group were considerably lower than those in the control group after surgery;however,the JOA scores in the observation group were significantly higher than those in the control group(P<0.05).No significant differences were observed in cervical disc height and the range of motion of the superior or inferior adjacent vertebrae between the two groups before surgery(P>0.05).The disc height in the observation group was larger than that in the control group after surgery.The range of motion of both the superior and inferior adjacent vertebrae was significantly smaller in the observation group than in the control group(P<0.05).The incidence of complications was only 2.22% in the observation group compared to 15.56% in the control group,and the difference was statistically significant(P<0.05).CONCLUSION Cervical spine function restoration was better with ROI-C with internal fixation in ACDF than with conventional titanium plates in ACDF for CDD disease.
文摘This work focuses on the influence of elastic modulus on biomechanical properties of lumbar interbody fusion cages by selecting two titanium alloys with different elastic modulus. They were made by a new β type alloy with chemical composition of Ti-24Nb-4Zr-7.6Sn having low Young's modulus -50 GPa and by a conventional biomedical alloy Ti-6Al-4V having Young's modulus -110 GPa. The results showed that the designed cages with low modulus (LMC) and high modulus (HMC) can keep identical compression load -9.8 kN and endure fatigue cycles higher than 5× 10^6 without functional or mechanical failure under 2.0 kN axial compression. The anti-subsidence ability of both group cages were examined by axial compression of thoracic spine specimens (T9-T10) dissected freshly from the calf with averaged age of 6 months. The results showed that the LMC has better anti-subsidence ability than the HMC (p〈0.05). The above results suggest that the cage with low elastic modulus has great potential for clinical applications.
文摘In this study,the characteristics of heat transfer on an unsteady magnetohydrodynamic(MHD)Casson nanofluid over an exponentially accelerated vertical porous plate with rotating effects were investigated.The flow was driven by the combined effects of the magnetic field,heat radiation,heat source/sink and chemical reaction.Copper oxide(CuO)and titanium oxide(TiO2)are acknowledged as nanoparticle materials.The nondimensional governing equations were subjected to the Laplace transformation technique to derive closed-form solutions.Graphical representations are provided to analyze how changes in physical parameters,such as the magnetic field,heat radiation,heat source/sink and chemical reaction,affect the velocity,temperature and concentration profiles.The computed values of skin friction,heat and mass transfer rates at the surface were tabulated for various sets of input parameters.It is perceived that there is a drop in temperature due to the rise in the heat source/sink and the Prandtl number.It should be noted that a boost in the thermal radiation parameter prompts an increase in temperature.An increase in the Prandtl number,heat source/sink parameter,time and a decrease in the thermal radiation parameter result in an increase in theNusselt number.The computed values of the skin friction,heat andmass transfer rates at the surface were tabulated for various values of the flow parameters.The present results were compared with those of previously published studies andwere found to be in excellent agreement.This research has practical applications in areas such as drug delivery,thermal medicine and cancer treatment.
基金supported by the National High Technology Research and Development Program of China(Grant No.2012AA03A508)the National Natural Science Foundation of China(Grant Nos.U1360102,51275344)
文摘In the present study, titanium plate was treated by a novel method of laser quenching, simultaneously combined with liquidnitrogen cryogenics(LQLNC). The microstructure and properties of the titanium plate after treatment were investigated by X-ray diffraction, scanning electron microscopy, energy dispersive spectrometry, Vickers hardness testing, and friction wear testing.The results show that the treated titanium plate is covered by a nitrided layer with a homogeneous thickness of about 60 μm,while the nitrided layer consists of Ti N and α-Ti phases. Compared to general laser quenching, the LQLNC treatment increases the hardness and wear resistance of the surface-modified layer of the titanium plate. As a result of grain refinement in the nitrided layer, the cracking induced by the rapid solidification of the conventional laser-quenching process has also been effectively solved.
文摘Objective:To observe the clinical effect of anterior decompression and reconstruction using titanium mesh with locking plates in the treatment of cervical spondylotic myelopathy. Methods:One hundred and twenty patients with cervical spondylotic myelopathy were treated by anterior decompression and reconstruction using titanium mesh with locking plates. There were 66 men and 54 women ranges in age from 37 to 72 Years(mean age, 58.3 years). The mean Japanese orthopedic surgery association(JOA) scale was 9.6 points before operation. Patients were followed up clinically and radiographically. Results:Having stood surgery well, the operation time ranged between 60-100 min and bleeding during operation ranged between 20-200 ml. There were no case of postoperative infection, recurrent laryngeal nerve palsy, or esophageal or tracheal laceration or rupture. The average follow-up period was 14.3 months(range, 12 to 24 months) in 96 who were followed up. At the last follow-up visit the mean JOA scale had improved to 14.4 points, reflecting an improvement of 4.8 points. The results were considered to be excellent in 87 patients, good in 25, fair in 6, and poor in 2. No hardware-related complications or adjacent segment degenerative changes were encountered during the follow-up periods. Stable bone union was observed in all cases and the average time required for fusion was 5.7 months. Conclusion:Titanium mesh filled with autologous bone graft can avoid the complications associated with harvesting bone from the iliac crest donor site. When combined with cervical anterior locking plate, it can obtain satisfatory clinical results for the treatment of cervical spondylotic myelopathy.
文摘In this study,the interface characteristics of a direct hot rolling titanium-clad steel plate were analyzed, and the mechanism of interface cracking was explored. The detrimental effect from the formation of TiFe ,TiC,and a Si-enriched layer on the bonding strength was clarified, and an industrial-scaled titanium-clad steel plate with shear strength over 200 MPa was produced with a carefully set schedule accordingly. It was found that hot rolling titanium-clad steel plates had a flat interface without obvious cracks. In the rolling process,both Ti and Fe atoms interdiflhsed,but Fe difthsed much faster than Ti. The Fe-diffused area consisted of three regions. After a high temperature heat treatment, the diffusion depth of Fe and Ti elements increased significantly and evident Si segregation and TiFe layers were identified. Thermal cracking initiated in the Si segregation layer and then propagated along the TiFe layer and Fe-diffused layer on the titanium side.
文摘Chest wall reconstruction after en-bloc tumor resection is very important to preserve functional mobility and to enhance the cosmetic effect. Because they are flexible and pliable, titanium plates are proposed to reconstruct the chest wall, even though such chest wall reconstruction has been performed in only a few cases worldwide. We present a case of a 49-year-old man with a chondrosarcoma arising from the left 1st rib, invading the manubrium, clavicle, 2nd and 3rd ribs, and the anterior segment of the left upper lobe. After wide resection, the chest wall was reconstructed using titanium rib plates and Marlex mesh- the Bovine pericardium sandwich type. The patient tolerated the pain well, and fourteen months after surgery, the chest wall was well preserved function mobility and improved pulmonary function test.
文摘The scanning electron microscope (SEM) results of bone interface of titanium-coated 317L plate screw are reported in this article. 317L plate screw had a rough surface composed of sprayed pure titanium which formed a bone/metal interface in biointegration after implanted into the mandible of dog. Though a bone/metal interface in osseointegration was also formed on the surface of uncoated 317L plate screw after implantation, a smal1 space was seen between the bone and surface of the screw, indicating that the tissue compatibility of titanium-coated 317L plate screw may be better than that of the non-coated screw.
文摘目的:颈前路减压融合术是治疗退行性颈椎病的经典手术方式,钉板的使用增加了融合率及稳定性的同时,间接导致了邻近椎体退变和术后吞咽困难的发生。文章通过Meta分析方法比较ROI-C^(TM)自锁系统和传统融合器联合钉板内固定治疗退行性颈椎病患者的临床结果和并发症情况,为颈前路减压融合术中内固定方式的选择提供循证学支持。方法:检索中国知网、万方、维普、PubMed、Cochrane Library、Web of Science和Embase数据库,检索关于颈前路减压融合术中应用ROI-C^(TM)自锁系统与融合器联合钉板内固定治疗退行性颈椎病的中英文文献。检索时间范围为各数据库建库至2023年7月。由2名研究者严格按照纳入与排除标准选择文献,采用Cochrane偏倚风险工具对随机对照试验进行质量评价,NOS量表对队列研究进行质量评价。采用RevMan 5.4软件进行Meta分析。结局指标包括手术时间、术中出血量、日本骨科协会(Japanese Orthopaedic Association Scores,JOA)评分、颈椎功能障碍指数、C_(2)-C_(7)Cobb角、融合率、邻近椎体退变发生率、融合器沉降率和吞咽困难发生率。结果:共纳入13项研究,其中回顾性队列研究11项,随机对照试验2项,共1136例患者,ROI-C组569例,融合器联合钉板组567例。Meta分析结果显示:ROI-C组与融合器联合钉板组在手术时间(MD=-15.52,95%CI:-18.62至-12.42,P<0.00001),术中出血量(MD=-24.53,95%CI:-32.46至-16.61,P<0.00001),术后邻近节段退变率(RR=0.40,95%CI:0.27-0.60,P<0.00001)和术后总吞咽困难发生率(RR=0.18,95%CI:0.13-0.26,P<0.00001)均具有显著性差异。两者在术后JOA评分、颈椎功能障碍指数、C_(2)-C_(7)Cobb角、融合率和融合器沉降率方面无显著性差异(P≥0.05)。结论:在颈椎前路减压融合术中应用ROI-C^(TM)自锁系统与传统融合器联合钉板内固定治疗退行性颈椎病均可达到满意的临床效果,ROI-C^(TM)自锁系统操作更加简单,相比融合器联合钉板内固定能明显减少手术时间及术中出血量,在减少术后吞咽困难及邻近节段退变发生率等方面具有明显优势,对于跳跃型颈椎病及邻椎病翻修患者,更加推荐使用ROI-C^(TM)自锁系统。但鉴于其可能存在较高的沉降率,对于多节段且合并融合器沉降高危因素如骨质疏松、椎体终板破损的退行性颈椎病患者,仍建议使用融合器联合钉板内固定。