The sonic fatigue life of the aluminium rectangular panel was calculated using the concise method[1], and the sonic fatigue test was conducted on progressive wave tube (PWT) test facility. A comparison was made betwee...The sonic fatigue life of the aluminium rectangular panel was calculated using the concise method[1], and the sonic fatigue test was conducted on progressive wave tube (PWT) test facility. A comparison was made between the results of calculation and test, and it shows reasonable agreement between these two results.展开更多
文摘The sonic fatigue life of the aluminium rectangular panel was calculated using the concise method[1], and the sonic fatigue test was conducted on progressive wave tube (PWT) test facility. A comparison was made between the results of calculation and test, and it shows reasonable agreement between these two results.