期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Abductive statistical methods improve the results of calibration curve bioassays:An example of determining zinc bioavailability in broiler chickens
1
作者 Gene M.Pesti Lynne Billard +3 位作者 Shu-Biao Wu Robert A.Swick Thi Thanh Hoai Nguyen Natalie Morgan 《Animal Nutrition》 SCIE CSCD 2022年第3期294-304,共11页
In this paper,we discuss the theory behind calibration curve experiments and their application to a zinc(Zn)bioavailability study with broiler chickens.Seven replicates of 16 male commercial broiler chicks were fed st... In this paper,we discuss the theory behind calibration curve experiments and their application to a zinc(Zn)bioavailability study with broiler chickens.Seven replicates of 16 male commercial broiler chicks were fed starter diets for 14 days.Six diets had different levels of a potential Zn source and one was a positive control with standard industry levels of Zn for comparison.Four commonly used methods of calculating bioavailability means and confidence intervals(CI)from a calibration curve(standard curve)experiment to estimate the bioavailability of a new zinc source in broiler chickens were compared.The methods compared were the following:1)the Counter-Intuitive Method uses a multiple-range test to compare unknown test and standard samples;2)the Intuitive Method uses standard linear regression and inverts the equation to predict Zn bioavailability for each replicate of test samples;3)the Abductive Method uses Graybill's Equation,based on theory and observation,to estimate CI's;and 4)the Sophistic Method uses reverse regression,and calculates Zn bioavailability values directly from the equation.The Counter-Intuitive Method only gives information about which standards the test samples are,or are not,significantly different from respectively(average available Zn not predicted).The Intuitive Method ignores error about the standard curve and theoretically cannot estimate the CI directly(X±SEM=107.5±15.8 mg Zn/kg).The Sophistic Method underestimates and overestimates the test sample mean values above and below the mean of the standards,respectively(X=96.6 mg Zn/kg).The Abductive Method has an advantage over the other methods:The mean prediction estimation is consistent with theory(107.5±6.1 mg Zn/kg;X±SEM).When test or“unknown”samples are near the mean of the standard samples,the CI is smaller than when near the extremes of the calibration curve.When calibration curve error is small(R^(2)>approximately 0.95),there is little advantage to using the Abductive Method,but when calibration curve error is larger,as in many bioassays with growing animals,the Abductive Method improves the accuracy of the CI calculations.The Abductive Method was used to demonstrate the influence of the number of replicate samples on experimental power and cost. 展开更多
关键词 calibration curve Standard curve Confidence interval BIOAVAILABILITY
原文传递
Matrix effect suppressing in the element analysis of soils by laser-induced breakdown spectroscopy with acoustic correction
2
作者 何智权 刘莉 +6 位作者 郝中骐 徐智帅 王奇 卢颖 赵梓屹 史久林 何兴道 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第12期97-104,共8页
Laser-induced breakdown spectroscopy(LIBS)has been used for soil analysis,but its measurement accuracy is often influenced by matrix effects of different kinds of soils.In this work,a method for matrix effect suppress... Laser-induced breakdown spectroscopy(LIBS)has been used for soil analysis,but its measurement accuracy is often influenced by matrix effects of different kinds of soils.In this work,a method for matrix effect suppressing was developed using laser-induced plasma acoustic signals to correct the original spectrum,thereby improving the analysis accuracy of the soil elements.A good linear relationship was investigated firstly between the original spectral intensity and the acoustic signals.The relative standard deviations(RSDs)of Mg,Ca,Sr,and Ba elements were then calculated for both the original spectrum and the spectrum with the acoustic correction,and the RSDs were significantly reduced with the acoustic correction.Finally,calibration curves of MgⅠ285.213 nm,CaⅠ422.673 nm,SrⅠ460.733 nm and BaⅡ455.403 nm were established to assess the analytical performance of the proposed acoustic correction method.The values of the determination coefficient(R~2)of the calibration curves for Mg,Ca,Sr,and Ba elements,corrected by the acoustic amplitude,are improved from 0.9845,0.9588,0.6165,and 0.6490 to 0.9876,0.9677,0.8768,and 0.8209,respectively.The values of R~2 of the calibration curves corrected by the acoustic energy are further improved to 0.9917,0.9827,0.8835,and 0.8694,respectively.These results suggest that the matrix effect of LIBS on soils can be clearly improved by using acoustic correction,and acoustic energy correction works more efficiently than acoustic amplitude correction.This work provides a simple and efficient method for correcting matrix effects in the element analysis of soils by acoustic signals. 展开更多
关键词 laser-induced breakdown spectroscopy acoustic correction matrix effect calibration curve relative standard deviation
下载PDF
Closed/Open-Cell Photoacoustic Imaging for Spectroscopic Measurements 被引量:1
3
作者 Tsutomu Hoshimiya 《Journal of Applied Mathematics and Physics》 2016年第8期1470-1474,共6页
Photoacoustic imaging using a closed photoacoustic cell and an open photoacoustic cell with gas- microphone detection scheme was described. R/G/B LED light sources were used for the closed photoacoustic (PA) cell conf... Photoacoustic imaging using a closed photoacoustic cell and an open photoacoustic cell with gas- microphone detection scheme was described. R/G/B LED light sources were used for the closed photoacoustic (PA) cell configuration. The colored specimen enclosed in a PA cell was imaged with R/G/B color light sources, and an image restored from the inverted PA images was compared with the original image. For open cell configuration, an open PA cell using a spheroidal acoustic resonator was applied to measure the amount of large-sized colored specimens. A calibration curve for a food red dye was obtained that apparently showed the ability of the present scheme to measure as a spectroscopic measurement tool. 展开更多
关键词 PHOTOACOUSTIC IMAGING SPECTROSCOPIC calibration curve Color Restoration
下载PDF
Variation of the friction conditions in cold ring compression tests of medium carbon steel 被引量:5
4
作者 Dawei ZHANG Bingkun LIU +2 位作者 Jingxiang LI Minchao CUI Shengdun ZHAO 《Friction》 SCIE CSCD 2020年第2期311-322,共12页
Lubrication and friction conditions vary with deformation during metal forming processes.Significant macro-variations can be observed when a threshold of deformation is reached.This study shows that during the cold co... Lubrication and friction conditions vary with deformation during metal forming processes.Significant macro-variations can be observed when a threshold of deformation is reached.This study shows that during the cold compression processing of#45(AISI 1045)steel rings,the magnitude of friction and surface roughness(Ra)changes significantly upon reaching a 45%reduction in ring height.For example,the Ra of compressed ring specimens increased by approximately 55%immediately before and after reaching this threshold,compared to an 18% or 25%variation over a 35%-45%or a 45%-55%reduction in height,respectively.The ring compression test conducted by this study indicates that the Coulomb friction coefficient and Tresca friction factor mare 0.105 and 0.22,respectively,when the reduction in height is less than 45%;and 0.11 and 0.24,respectively,when the reduction in height is greater than 45%. 展开更多
关键词 friction condition ring compression test friction calibration curve surface topography
原文传递
A general strategy to quantify analytes through fluorescence chromaticity and luminosity
5
作者 Tianyu Liang Peiwei Yang +4 位作者 Tianhong Wu Menghan Shi Xiayu Xu Taotao Qiang Xiaolong Sun 《Chinese Chemical Letters》 SCIE CAS CSCD 2020年第11期2975-2979,共5页
To realize a fast,easy-operation and precise way using fluorescence probes to quantify analytes is a goal to facilitate detection,especially in situ.Herein,we are reporting an approach which can be generally employed ... To realize a fast,easy-operation and precise way using fluorescence probes to quantify analytes is a goal to facilitate detection,especially in situ.Herein,we are reporting an approach which can be generally employed for the differentiation and quantitation of analytes through fluorescence chromaticity and luminosity.Seven representative fluorescent probes,targeting p H,cysteine,hydrogen sulfide,hydrogen peroxide,palladium and hydrazine,were synthesized and tested.Without utilizing costly instrumentations,portable devices were employed to collect data of photographs from the fluorescence samples in responses to different analytes.Subsequently,the photographic images were digitally processed to generate calibration curves between chromaticity/luminosity verse concentrations after mapping to the CIE 1931 xy Y standard color space.Good linear calibration curves and quantitative analysis of unknown samples with low errors through the spectral technology demonstrated the reliability of this method.Thus,we showed the analytical method with a simple and on-site constructible/portable device which is promising for applications in more fluorescence probes. 展开更多
关键词 Fluorescence probes Portable device calibration curve PHOTOGRAPHY Chromaticity and luminosity
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部