Standard plenoptic camera can be used to capture multi-dimensional radiation information of high temperature luminous flame to reconstruct the temperature distribution. In this study, a novel method for reconstructing...Standard plenoptic camera can be used to capture multi-dimensional radiation information of high temperature luminous flame to reconstruct the temperature distribution. In this study, a novel method for reconstructing three-dimensional temperature field is proposed. This method is based on the optical tomography combined with standard plenoptic camera. The flame projection information from different planes is contained in one radiation image. In this model, we introduced the effective concept of the nearest neighbor method in the frequency domain to strip the interference of redundant information in the projection and to realize three-dimensional deconvolution. The flame emission intensity received by the pixels on the charge-coupled device sensor can be obtained according to the optical tomographic model. The temperature distributions of the axisymmetric and nonaxisymmetric flames can be reconstructed by solving the mathematical model with the nearest neighbor method. The numerical results show that three-dimensional temperature fields of high temperature luminous flames can be retrieved, proving the validity of the proposed method.展开更多
基金supported by the National Natural Science Foundation of China (Grant No. 51976044)the National Science and Technology Major Project (Grant No. 2017-V-0016-0069)the Foundation of Heilongjiang Touyan Innovation Team Program。
文摘Standard plenoptic camera can be used to capture multi-dimensional radiation information of high temperature luminous flame to reconstruct the temperature distribution. In this study, a novel method for reconstructing three-dimensional temperature field is proposed. This method is based on the optical tomography combined with standard plenoptic camera. The flame projection information from different planes is contained in one radiation image. In this model, we introduced the effective concept of the nearest neighbor method in the frequency domain to strip the interference of redundant information in the projection and to realize three-dimensional deconvolution. The flame emission intensity received by the pixels on the charge-coupled device sensor can be obtained according to the optical tomographic model. The temperature distributions of the axisymmetric and nonaxisymmetric flames can be reconstructed by solving the mathematical model with the nearest neighbor method. The numerical results show that three-dimensional temperature fields of high temperature luminous flames can be retrieved, proving the validity of the proposed method.