期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
High Resolution Differential Capacitance Detection Scheme for Micro Levitated Rotor Gyroscope 被引量:2
1
作者 Huang Xiaogang Chen Wenyuan Liu Wu Zhang Weiping Wu Xiaosheng 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2007年第6期546-551,共6页
A differential capacitance detection circuit aiming at detection of rotating angle in a novel levitation structure is presented. To ensure the low non-linearity and high resolution, noise analysis and non-linearity si... A differential capacitance detection circuit aiming at detection of rotating angle in a novel levitation structure is presented. To ensure the low non-linearity and high resolution, noise analysis and non-linearity simulation are conducted. In the capacitance interface, an integral charge amplifier is adopted as a front end amplifier to reduce the parasitic capacitance caused by connecting wire. For the novel differential capacitance bridge with a coupling capacitor, the noise floor and non-linearity of the detection circuit are analyzed, and the results show that the detecting circuit is capable of realizing angle detection with high angular resolution and relative low non-linearity. With a specially designed printed circuit board, the circuit is simulated by PSpice. The practical experiment shows that the detection board can achieve angular resolution as high as 0.04° with a non-linearity error 2.3%. 展开更多
关键词 MEMS micro gyroscope capacitance sensing inertial sensor angle detection
下载PDF
Fabric-substrated capacitive biopotential sensors enhanced by dielectric nanoparticles 被引量:1
2
作者 Xiangjun Chen Xiaoxiang Gao +12 位作者 Akihiro Nomoto Keren Shi Muyang Lin Hongjie Hu Yue Gu Yangzhi Zhu Zhuohong Wu Xue Chen Xinyu Wang Baiyan Qi Sai Zhou Hong Ding Sheng Xu 《Nano Research》 SCIE EI CSCD 2021年第9期3248-3252,共5页
Wearable biopotential sensing devices are essential to long-term and real-time monitoring of human health.Non-contact,capacitive sensing electrodes prevent potential skin iritations,and are thus beneficial for long-te... Wearable biopotential sensing devices are essential to long-term and real-time monitoring of human health.Non-contact,capacitive sensing electrodes prevent potential skin iritations,and are thus beneficial for long-term monitoring.Existing capacitive electrodes are either connected to a separate control circuit via external wires or have limited sensing capacitances,which leads to low signal qualities.This study demonstrates a stretchable capacitive sensing device with integrated electrodes and control electronics,with enhanced signal qualities.The electrodes and the control electronics are fabricated on a common fabric substrate for breathability and strain-limiting protection.The stretchable electrodes are based on an island-bridge design with a stretchability as high as-100%,and an area ratio as high as-80%.By using a dielectric calcium copper titanate(CCTO)composite as the adhesive layer,the electrode capacitance can be increased,yielding an enhanced signal-to-noise ratio(SNR)in the acquired biopotentials.This device offers a convenient and comfortable approach for long-term non-contact monitoring of biopotential signals. 展开更多
关键词 capacitive sensing biopotential STRETCHABLE calcium copper titanate(CCTO) signal-to-noise ratio(SNR)
原文传递
A portable and low-cost parallel-plate capacitor sensor for alkali and heavy metal ions detection
3
作者 Septia Kholimatussadiah Tri Anggono Prijo 《Journal of Advanced Dielectrics》 CAS 2018年第4期28-34,共7页
A portable and low-cost design of parallel-plate capacitor sensor is proposed and investigated for detection of heavy and alkali metal ions concentration in liquid solution.The application of a thin and long-sided par... A portable and low-cost design of parallel-plate capacitor sensor is proposed and investigated for detection of heavy and alkali metal ions concentration in liquid solution.The application of a thin and long-sided parallel PCB plate allows one to measure the dielectric response of each sample through capacitive sensing technique.The measurements were based on the peak output voltage corresponding to the capacitance of the output measured by an oscilloscope with metal ions concentration of the solution varying from 0 to 10 ppm and input frequency ranging from 1 kHz to 10 MHz.The ICF of Li,Na and K in chloride solution was 2.4,2.1 and 1.9 MHz,respectively.The ICF of Na and K in hydroxide solution was 1.5 MHz and 1.1 MHz,respectively,while the ICF of Pb(NO_(3))_(2)was 490 kHz.The detected ICF was applied to further construct the portable sensor system,which is simple in design,low-cost in fabrication and easy to operate.The finding of ICF of each chemical element is necessary to solve the selectivity challenge of the capacitance-based sensor,which will be appropriate for chemical,environmental and engineering applications. 展开更多
关键词 Capacitive sensing capacitor sensor characteristic frequency metal ions detection parallel-plate capacitor.
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部