期刊文献+
共找到36篇文章
< 1 2 >
每页显示 20 50 100
Development of capacitive sensor signal conditioning system for angular displacement measurement using timer IC LM555 and UFDC 被引量:2
1
作者 Sumitesh Majumder T K Maiti 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2019年第1期49-54,共6页
In this research paper,we have presented variable area type capacitive sensor signal conditioning system for angular displacement measurement and for this purpose we have used timer LM555 based astable multivibrator a... In this research paper,we have presented variable area type capacitive sensor signal conditioning system for angular displacement measurement and for this purpose we have used timer LM555 based astable multivibrator and universal frequency to digital converter (UFDC). Due to variation in angular displacement in the variable area type capacitor which is connected in the timer based astable circuit,capacitance changes which in turn changes the time period of the timer circuit output. The time period of the timer output waveform is linear with the capacitance and hence linear with angular displacement. The timer output is further processed with UFDC for the measurement. The experimental results show that the time period is linear with the angular displacement in the range of 0- 180° and the uncertainty we should associate it with this average time period value is the standard deviation of the mean,often called the standard error (SE),which is ± 0.023 μs. Because of the simplicity,this measurement system can be used in both electronic and industrial instrumentation. 展开更多
关键词 variable area type capacitive sensor timer circuit sensor interfacing astable multivibrator universal frequency to digital converter (UFDC)
下载PDF
A Novel Uniplanar Multi-Electrode Capacitive Sensor for In-Situ Weathering Damage Detection of Nonmetallic Materials 被引量:1
2
作者 Ensheng Dong Yonggui Dong +2 位作者 Wener Lv Huibo Jia Jun Li 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期630-633,共4页
A uniplanar capacitive sensor with 5-electrodes on one plane substrate and a large reflector electrode,was designed to get the corresponding capacitance information for weathering damage detection of non-metallic mate... A uniplanar capacitive sensor with 5-electrodes on one plane substrate and a large reflector electrode,was designed to get the corresponding capacitance information for weathering damage detection of non-metallic materials exposed to a service environment.A 2-D finite-element method was employed to simulate the electric potential distribution and capacitance measurements for the sensor.2 marble slabs,one was healthy and the other was notched,were experimentally detected.Both the simulation and the preliminary experimental results show that the measured capacitances decrease after weathering damage occurs in nonmetallic material.The reflector can enlarge the sensitive depth.The weathering assessment of nonmetallic materials can be done by processing the measured capacitances.The proposed approach can effectively detect the weathering damage of nonmetallic material and can be practically used for in-situ weathering damage evaluation. 展开更多
关键词 capacitive sensor weathering damage detection reflector electrode non-metallic materials
下载PDF
Recent progress in flexible capacitive sensors:Structures and properties 被引量:1
3
作者 Zhuyu Ma Yang Zhang +2 位作者 Kaiyi Zhang Hua Deng Qiang Fu 《Nano Materials Science》 EI CAS CSCD 2023年第3期265-277,共13页
The future intelligent era that will be brought about by 5G technology can be well predicted.For example,the connection between humans and smart wearable devices will become increasingly more intimate.Flexible wearabl... The future intelligent era that will be brought about by 5G technology can be well predicted.For example,the connection between humans and smart wearable devices will become increasingly more intimate.Flexible wearable pressure sensors have received much attention as a part of this process.Nevertheless,there is a lack of complete and detailed discussion on the recent research status of capacitive pressure sensors composed of polymer composites.Therefore,this article will mainly discuss the key concepts,preparation methods and main performance of flexible wearable capacitive sensors.The concept of a processing“toolbox”is used to review the developmental status of the dielectric layer as revealed in highly cited literature from the past five years.The preparation methods are categorized into types of processing:primary and secondary.Using these categories,the preparation methods and structure of the dielectric layer are discussed.Their influence on the final capacitive sensing behavior is also addressed.Recent developments in the electrode layer are also systematically reviewed.Finally,the results of the above discussion are summarized and future development trends are discussed. 展开更多
关键词 capacitive sensors Dielectric layer Structures and properties PROCESSING
下载PDF
Flexible capacitive pressure sensor based on interdigital electrodes with porous microneedle arrays for physiological signal monitoring
4
作者 Jiahui Xu Minghao Wang +9 位作者 Minyi Jin Siyan Shang Chuner Ni Yili Hu Xun Sun Jun Xu Bowen Ji Le Li Yuhua Cheng Gaofeng Wang 《Nanotechnology and Precision Engineering》 EI CAS CSCD 2024年第1期18-31,共14页
Flexible pressure sensors have many potential applications in the monitoring of physiological signals because of their good biocompatibil-ity and wearability.However,their relatively low sensitivity,linearity,and stab... Flexible pressure sensors have many potential applications in the monitoring of physiological signals because of their good biocompatibil-ity and wearability.However,their relatively low sensitivity,linearity,and stability have hindered their large-scale commercial application.Herein,aflexible capacitive pressure sensor based on an interdigital electrode structure with two porous microneedle arrays(MNAs)is pro-posed.The porous substrate that constitutes the MNA is a mixed product of polydimethylsiloxane and NaHCO3.Due to its porous and interdigital structure,the maximum sensitivity(0.07 kPa-1)of a porous MNA-based pressure sensor was found to be seven times higher than that of an imporous MNA pressure sensor,and it was much greater than that of aflat pressure sensor without a porous MNA structure.Finite-element analysis showed that the interdigital MNA structure can greatly increase the strain and improve the sensitivity of the sen-sor.In addition,the porous MNA-based pressure sensor was found to have good stability over 1500 loading cycles as a result of its bilayer parylene-enhanced conductive electrode structure.Most importantly,it was found that the sensor could accurately monitor the motion of afinger,wrist joint,arm,face,abdomen,eye,and Adam’s apple.Furthermore,preliminary semantic recognition was achieved by monitoring the movement of the Adam’s apple.Finally,multiple pressure sensors were integrated into a 33 array to detect a spatial pressure distribu-×tion.Compared to the sensors reported in previous works,the interdigital electrode structure presented in this work improves sensitivity and stability by modifying the electrode layer rather than the dielectric layer. 展开更多
关键词 capacitive pressure sensor Microneedle array Porous PDMS Interdigital electrode
下载PDF
A planar capacitive sensor for 2D long-range displacement measurement 被引量:3
5
作者 Jian-ping YU Wen WANG +2 位作者 Ke-qing LU De-qing MEI Zi-chen CHEN 《Journal of Zhejiang University-Science C(Computers and Electronics)》 SCIE EI 2013年第4期252-257,共6页
A planar capacitive sensor(PCS) capable of 2D large-scale measurement is presented in this paper.Displacement interpretation depends on independently measuring the periodic variation in capacitance caused by the chang... A planar capacitive sensor(PCS) capable of 2D large-scale measurement is presented in this paper.Displacement interpretation depends on independently measuring the periodic variation in capacitance caused by the change in the overlapping area of sensing electrodes on a moving plate and a fixed plate.By accumulating the number of quarters in each direction and the specific position in the final quarter,the large-scale measurement is fulfilled.Displacements in Xand Y-direction can be measured independently and simultaneously.Simulation shows that a shorter gap distance and a longer electrode guarantee better sensitivity.Experiments based on a PCS test bench demonstrate that the PCS has a sensitivity of 0.198 mV/μm and a resolution of 0.308 μm.An electric fringe effect and other possible measurement errors on displacement interpretation accuracy are discussed.The study confirms the high potential of PCSs as innovative 2D long-range displacement sensors. 展开更多
关键词 Planar capacitive sensor (PCS) Displacement measurement 2D large-scale measurement
原文传递
A bionic approach for the mechanical and electrical decoupling of an MEMS capacitive sensor in ultralow force measurement
6
作者 Wendi GAO Bian TIAN +9 位作者 Cunlang LIU Yingbiao MI Chen JIA Libo ZHAO Tao LIU Nan ZHU Ping YANG Qijing LIN Zhuangde JIANG Dong SUN 《Frontiers of Mechanical Engineering》 SCIE CSCD 2023年第2期297-317,共21页
Capacitive sensors are efficient tools for biophysical force measurement,which is essential for the exploration of cellular behavior.However,attention has been rarely given on the influences of external mechanical and... Capacitive sensors are efficient tools for biophysical force measurement,which is essential for the exploration of cellular behavior.However,attention has been rarely given on the influences of external mechanical and internal electrical interferences on capacitive sensors.In this work,a bionic swallow structure design norm was developed for mechanical decoupling,and the influences of structural parameters on mechanical behavior were fully analyzed and optimized.A bionic feather comb distribution strategy and a portable readout circuit were proposed for eliminating electrostatic interferences.Electrostatic instability was evaluated,and electrostatic decoupling performance was verified on the basis of a novel measurement method utilizing four complementary comb arrays and applicationspecific integrated circuit readouts.An electrostatic pulling experiment showed that the bionic swallow structure hardly moved by 0.770 nm,and the measurement error was less than 0.009% for the area-variant sensor and 1.118% for the gap-variant sensor,which can be easily compensated in readouts.The proposed sensor also exhibited high resistance against electrostatic rotation,and the resulting measurement error dropped below 0.751%.The rotation interferences were less than 0.330 nm and(1.829×10^(-7))°,which were 35 times smaller than those of the traditional differential one.Based on the proposed bionic decoupling method,the fabricated sensor exhibited overwhelming capacitive sensitivity values of 7.078 and 1.473 pF/μm for gap-variant and area-variant devices,respectively,which were the highest among the current devices.High immunity to mechanical disturbances was maintained simultaneously,i.e.,less than 0.369% and 0.058% of the sensor outputs for the gap-variant and area-variant devices,respectively,indicating its great performance improvements over existing devices and feasibility in ultralow biomedical force measurement. 展开更多
关键词 micro-electro-mechanical system capacitive sensor BIONICS operation instability mechanical and electrical decoupling biomedical force measurement
原文传递
Calibration Method of Capacitive Soil Moisture Sensor 被引量:2
7
作者 XIAO Lei JI Tianjian ZHANG Qingsong 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2020年第S01期109-114,共6页
Soil properties and water content vary from place to place. The calibration method based on capacitive soil moisture and humidity sensor is carried out. The sensor readings are compared with the mass water content mea... Soil properties and water content vary from place to place. The calibration method based on capacitive soil moisture and humidity sensor is carried out. The sensor readings are compared with the mass water content measured by the oven dried method,and the calibration formula of sensor reading and mass moisture content is established.Results show that the sensor reading has a good linear relationship with the mass water content measured by the oven dried method,and has high precision. It can calibrate the mass moisture content of the data obtained from the moisture migration test in the soil column. 展开更多
关键词 capacitive soil moisture sensor mass moisture content CALIBRATION laboratory tests
下载PDF
Capacitive sensor probe to assess frying oil degradation 被引量:1
8
作者 Alfadhl Yahya Khaled Samsuzana Abd Aziz Fakhrul Zaman Rokhani 《Information Processing in Agriculture》 EI 2015年第2期142-148,共7页
The repeated usage of frying oil has been proven hazardous due to the degradation process by chemical reactions that lead to changes in the quality of the oil.Currently,the degree of frying oil degradation is indicate... The repeated usage of frying oil has been proven hazardous due to the degradation process by chemical reactions that lead to changes in the quality of the oil.Currently,the degree of frying oil degradation is indicated by the percentage of its total polar compounds(TPC).In this study,a capacitive sensor was designed to assess frying oil degradation at several heating time intervals by measuring changes on its electrical capacitance.The sensor was designed using interdigitated electrode structure.A total of 30 samples of 130 ml palm oil were heated at 180℃ up to 30 h.For each one hour interval,one sample was moved out from the laboratory oven.The electrical capacitance,total polar compound(TPC)and viscosity of the samples were measured for analysis.Preliminary results demonstrated significant correlation between oil electrical capacitance with TPC and viscosity with R^2 ranged from 0.83 to 0.90.The designed sensor has good potential for simple and inexpensive way of determining frying oil quality. 展开更多
关键词 Capacitance sensor Frying oil quality HEATING
原文传递
Progress of Proximity Sensors for Potential Applications in Electronic Skins
9
作者 Runnan Zou Yanhong Tong +3 位作者 Jiayi Liu Jing Sun Da Xian Qingxin Tang 《Transactions of Tianjin University》 EI CAS 2024年第1期40-62,共23页
Recently,electronic skins and fl exible wearable devices have been developed for widespread applications in medical monitoring,artifi cial intelligence,human–machine interaction,and artifi cial prosthetics.Flexible p... Recently,electronic skins and fl exible wearable devices have been developed for widespread applications in medical monitoring,artifi cial intelligence,human–machine interaction,and artifi cial prosthetics.Flexible proximity sensors can accurately perceive external objects without contact,introducing a new way to achieve an ultrasensitive perception of objects.This article reviews the progress of fl exible capacitive proximity sensors,fl exible triboelectric proximity sensors,and fl exible gate-enhanced proximity sensors,focusing on their applications in the electronic skin fi eld.Herein,their working mechanism,materials,preparation methods,and research progress are discussed in detail.Finally,we summarize the future challenges in developing fl exible proximity sensors. 展开更多
关键词 capacitive proximity sensors Triboelectric proximity sensors Gate-enhanced proximity sensors Flexible wearable devices Electronic skins
下载PDF
Development of MEMS-based micro capacitive tactile probe
10
作者 雷李华 李源 +4 位作者 范国芳 吴俊杰 简黎 蔡潇雨 李同保 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第11期646-650,共5页
In this paper, a micro capacitive sensor with nanometer resolution is presented for ultra-precision measurement of micro components, which is fabricated by the MEMS (micro electromechanical systems) non-silicon tech... In this paper, a micro capacitive sensor with nanometer resolution is presented for ultra-precision measurement of micro components, which is fabricated by the MEMS (micro electromechanical systems) non-silicon technique. Based on the sensor, a micro capacitive tactile probe is constructed by stylus assembly and packaging design for dimension metrology on micro/nano scale, in which a data acquiring system is developed with AD7747. Some measurements of the micro capacitive tactile probe are performed on a nano positioning and measuring machine (NMM). The measurement results show good linearity and hysteresis with a range of 11.6 μm and resolution of better than 5 nm. Hence, the micro capacitive tactile probe can be integrated on NMM to realize measurement of micro structures with nanometer accuracy. 展开更多
关键词 micro tactile probe micro capacitive sensor MEMS nano measuring machine
下载PDF
Effects of electric field fringe on performances of grid strip capacitive MEMS devices
11
作者 董林玺 Li Yongjie +1 位作者 Yan Haixia Sun Lingling 《High Technology Letters》 EI CAS 2011年第2期207-213,共7页
Sensing structure of grid strip capacitors can be used in the design of capacitive micro-electromechanical system (MEMS) resonators, accelerometers etc. A grid strip structure consists of nonentirely overlap plates ... Sensing structure of grid strip capacitors can be used in the design of capacitive micro-electromechanical system (MEMS) resonators, accelerometers etc. A grid strip structure consists of nonentirely overlap plates so that the capacitor fringe effect cannot be neglected in the design. Electricmagnetic Finite Element Method (FEM) software ANSOFF-Maxwell is employed to analyze the fringe effect of a grid strip capacitor. The analysis includes capacitance changes with change of overlap length, overlap width, plate thickness, grid strip density etc. The results show that fringe effect leads to non-linear change of grid strip capacitance with the change of overlap length and width, that the capacitance increases with the increase of grid strip width and plate thickness, and that sensitivity can be improved through the increase of grid strip density in the condition of identical total overlap area, but linearity is reduced. 展开更多
关键词 micro-electro-mechanical system effect grid strip sensing capacitor MEMS noise (MEMS) capacitive sensor capacitor fringe
下载PDF
Liquid holdup measurement with double helix capacitance sensor in horizontal oil-water two-phase flow pipes 被引量:5
12
作者 翟路生 金宁德 +1 位作者 高忠科 王振亚 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2015年第1期268-275,共8页
This paper presents the characteristics of a double helix capacitance sensor for measurement of the liquid holdup in horizontal oil–water two-phase flow. The finite element method is used to calculate the sensitivity... This paper presents the characteristics of a double helix capacitance sensor for measurement of the liquid holdup in horizontal oil–water two-phase flow. The finite element method is used to calculate the sensitivity field of the sensor in a pipe with 20 mm inner diameter and the effect of sensor geometry on the distribution of sensitivity field is presented. Then, a horizontal oil–water two-phase flow experiment is carried out to measure the response of the double helix capacitance sensor, in which a novel method is proposed to calibrate the liquid holdup based on three pairs of parallel-wire capacitance probes. The performance of the sensor is analyzed in terms of the flow structures detected by mini-conductance array probes. 展开更多
关键词 Horizontal oil–water two-phase flow Liquid holdup measurement Double helix capacitance sensor Flow pattern
下载PDF
Nondestructive testing method of wood moisture content based on a planar capacitance sensor model 被引量:3
13
作者 WANG Jue LUO Yue-sheng LIU Shao-gang 《Forestry Studies in China》 CAS 2010年第3期142-146,共5页
For our research, a new hybrid experimental-computational method is presented. We applied a least squares fitting method (LSFM) to reconstruct the wood moisture content (WMC) from the data measured with a planar c... For our research, a new hybrid experimental-computational method is presented. We applied a least squares fitting method (LSFM) to reconstruct the wood moisture content (WMC) from the data measured with a planar capacitance sensor. A boundary element method (BEM) was used to compute the relationship between capacitance and the dielectric constant. A functional relationship between MC and the dielectric constant was identified by LSFM. The agreement of this final computation result with the experimental data indicates that this method can be used to estimate the WMC quickly and effectively with engineering analysis. Compared with popular statistical methods, a large number of experiments are avoided, some costs of testing are reduced and the efficiency of testing is enhanced. 展开更多
关键词 planar capacitance sensor nondestructive testing wood moisture content boundary element method least squares fitring method
下载PDF
Design of capacitance sensor system for void fraction measurement
14
作者 刘夷平 牛刚 王经 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2005年第12期1424-1429,共6页
Simulation and optimization were applied to a capacitive sensor system based on electrical tomography technology. Sensors, consisting of Morgantown Energy Technology Center (METC) axial synchro driving guard electrode... Simulation and optimization were applied to a capacitive sensor system based on electrical tomography technology. Sensors, consisting of Morgantown Energy Technology Center (METC) axial synchro driving guard electrodes and two sets of detecting electrodes, make it possible to obtain simultaneously two groups of signals of the void fraction in oil-gas two-phase flow. The computational and experimental results showed that available sensors, charactered by high resolution and fast real-time response can be used for real-time liquid-gas two-phase flow pattern determination. 展开更多
关键词 TOMOGRAPHY Capacitance sensors Finite element
下载PDF
Capacitance sensor for automatic soil retreat measurements
15
作者 顾军 杨娟 +4 位作者 尹武良 王超 王化祥 刘泽 程素森 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2008年第4期582-585,共4页
To continuously monitor the soil retreat due to erosion in field,provide valuable information about the erosion processes and overcome the disadvantages of inefficiency,high time-consumption and labor-intensity of exi... To continuously monitor the soil retreat due to erosion in field,provide valuable information about the erosion processes and overcome the disadvantages of inefficiency,high time-consumption and labor-intensity of existing methods,this paper describes a novel capacitance sensor for measuring the soil retreat.A capacitance sensor based probe is proposed,which can measure the depth of the soil around it automatically and the data can be recorded by a data logger.Experimental results in the lab verify its usefulness. 展开更多
关键词 soil erosion capacitance sensor finite element model
下载PDF
Textile-Based Capacitive Pressure Distribution Measurement System for Human Sitting Posture Monitoring
16
作者 SHI Yulong ZHENG Yuanyuan ZHANG Kun 《Journal of Donghua University(English Edition)》 CAS 2021年第6期492-497,共6页
Flexible pressure monitoring device can help correct the sitting posture and prevent health problems(e.g.,deformity of spinal column and musculoskeletal disease).Currently,most measurement systems hinder their wide ap... Flexible pressure monitoring device can help correct the sitting posture and prevent health problems(e.g.,deformity of spinal column and musculoskeletal disease).Currently,most measurement systems hinder their wide applications owing to the high cost or low accuracy.In this study,a flexible sitting pressure measurement system was proposed based on a textile-based capacitive pressure sensor array in order to measure sitting pressure distribution simply and conveniently.The capacitive pressure sensor array is sandwich structure composed of a high-density sponge layer and two electrode array fabrics,which possesses high resolution(2.26 sensors/cm2),high sensitivity(0.701 kPa-1)and fast response(≤35 ms).It is worth noting that the raw materials of the sensing fabric include commercialized copper sheets and polyester yarns.The as-prepared pressure measurement system can accurately measure the pressure distribution nephogram for sitting posture analysis.The sitting pressure of 10 volunteers was measured and six types of posture were distinguished clearly. 展开更多
关键词 smart textile capacitive pressure sensor pressure distribution sitting posture
下载PDF
Laser speckle grayscale lithography:a new tool for fabricating highly sensitive flexible capacitive pressure sensors
17
作者 Yong Zhou Kun Wang +5 位作者 Junkun Mao Yifei Ma Mei Wang Suotang Jia Xuyuan Chen Zhaomin Tong 《Light(Advanced Manufacturing)》 2024年第2期75-86,共12页
Achieving a high sensitivity for practical applications has always been one of the main developmental directions for wearable flexible pressure sensors.This paper introduces a laser speckle grayscale lithography syste... Achieving a high sensitivity for practical applications has always been one of the main developmental directions for wearable flexible pressure sensors.This paper introduces a laser speckle grayscale lithography system and a novel method for fabricating random conical array microstructures using grainy laser speckle patterns.Its feasibility is attributed to the autocorrelation function of the laser speckle intensity,which adheres to a first-order Bessel function of the first kind.Through objective speckle size and exposure dose manipulations,we developed a microstructured photoresist with various micromorphologies.These microstructures were used to form polydimethylsiloxane microstructured electrodes that were used in flexible capacitive pressure sensors.These-1 sensors exhibited an ultra-high sensitivity:19.76 kPa for the low-pressure range of 0-100 Pa.Their minimum detection threshold was 1.9 Pa,and they maintained stability and resilience over 10,000 test cycles.These sensors proved to be adept at capturing physiological signals and providing tactile feedback,thereby emphasizing their practical value. 展开更多
关键词 Laser speckle Grayscale lithography Random conical array Microstructured electrode Flexible capacitive pressure sensor.
原文传递
Dielectric Permittivity of Rigid Rapeseed Oil Polyol Polyurethane Biofoams and Petrochemical Foams at Low Frequencies 被引量:1
18
作者 Ilze Beverte Vairis Shtrauss +4 位作者 Aldis Kalpinsh Uldis Lomanovskis Ugis Cabulis Irina Sevastyanova Sergejs Gaidukovs 《Journal of Renewable Materials》 SCIE EI 2020年第9期1151-1170,共20页
Early investigations of dielectric permittivity of rigid polyurethane foams at low frequencies were made on petrochemical-origin foams,mainly by means of parallel plate capacitors.In the present investigation biopolyo... Early investigations of dielectric permittivity of rigid polyurethane foams at low frequencies were made on petrochemical-origin foams,mainly by means of parallel plate capacitors.In the present investigation biopolyol was synthesized from Latvia-grown rapeseeds’oil by the transesterification method with triethanolamine,in an environmentally friendly process,without emission of harmful substances,at temperatures 175℃±5℃.Rigid,closed-cell rapeseed oil polyol polyurethane biofoams and petrochemical foams were made ensuring content of the renewable rapeseed oil polyol in ready foams 27 wt.%–29 wt.%.Dielectric permittivity of the polyurethane foams and the underlying monolithic petrochemical-origin polyurethane and biopolyurethane was measured with a non-destructive dielectric spectrometer equipped with a capacitive sensor of one-side access type at 16 discrete frequencies distributed geometrically over the band 10 Hz,…,330 kHz.Permittivity value of the gaseous phase in the closed-cells was estimated to beεg≈1.001 that corresponds to the values,characteristic for the most of gases.Dielectric permittivity of petrochemical polyurethane foams and the mentioned biofoams was compared with permittivity of polyurethane foams from industrial producers Sika JSC and General Plastics Manufacturing Co.Polyurethane foams of the developed formulation exhibit competitive,low dielectric permittivity,not exceeding that of the foams from industrial producers:petrochemical foams up to 550 kg/m^(3) and the mentioned biofoams,comprising the renewable rapeseed oil polyol,up to densities 230–250 kg/m^(3).Considering petrochemical-origin polyurethane foams as a heterogeneous media“Polymer—gaseous phase”,the applicability of the rule of mixture and Maxwell–Garnett equation to model mathematically the dependence of effective dielectric permittivity on the volume fraction of phases was showed. 展开更多
关键词 Polyurethane foams rapeseed oil polyol biofoams dielectric permittivity capacitive sensor one-side access low frequencies
下载PDF
Progress in achieving high-performance piezoresistive and capacitiveflexible pressure sensors: A review 被引量:28
19
作者 Wufan Chen Xin Yan 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2020年第8期175-188,共14页
Electronic skin(e-skin) and flexible wearable devices are currently being developed with broad application prospects. Transforming electronic skin(e-skin) into true ¨skin¨is the ultimate goal. Tactile sensin... Electronic skin(e-skin) and flexible wearable devices are currently being developed with broad application prospects. Transforming electronic skin(e-skin) into true ¨skin¨is the ultimate goal. Tactile sensing is a fundamental function of skin and the development of high-performance flexible pressure sensors is necessary to realize thus. Many reports on flexible pressure sensors have been published in recent years,including numerous studies on improving sensor performance, and in particular, sensitivity. In addition,a number of studies have investigated self-healing materials, multifunctional sensing, and so on. Here,we review recent developments in flexible pressure sensors. First, working principles of flexible pressure sensors, including piezoresistivity, capacitance, and piezoelectricity, are introduced, as well as working mechanisms such as triboelectricity. Then studies on improving the performance of piezoresistive and capacitive flexible pressure sensors are discussed, in addition to other important aspects of this intriguing research field. Finally, we summarize future challenges in developing novel flexible pressure sensors. 展开更多
关键词 Electronic skin Flexible pressure sensor PIEZORESISTIVITY capacitive pressure sensor
原文传递
Flexible and transparent capacitive pressure sensor with patterned microstructured composite rubber dielectric for wearable touch keyboard application 被引量:29
20
作者 Ruilong Shi Zheng Lou +1 位作者 Shuai Chen Guozhen Shen 《Science China Materials》 SCIE EI CSCD 2018年第12期1587-1595,共9页
The development of pressure sensors with highly sensitivity, fast response and facile fabrication technique is desirable for wearable electronics. Here, we successfully fabricated a flexible transparent capacitive pre... The development of pressure sensors with highly sensitivity, fast response and facile fabrication technique is desirable for wearable electronics. Here, we successfully fabricated a flexible transparent capacitive pressure sensor based on patterned microstructured silver nanowires(AgNWs)/polydimethylsiloxane(PDMS) composite dielectrics. Compared with the pure PDMS dielectric layer with planar structures, the patterned microstructured sensor exhibits a higher sensitivity(0.831 kPa^-1, <0.5 kPa), a lower detection limit,good stability and durability. The enhanced sensing mechanism about the conductive filler content and the patterned microstructures has also been discussed. A 5×5 sensor array was then fabricated to be used as flexible and transparent wearable touch keyboards systems. The fabricated pressure sensor has great potential in the future electronic skin area. 展开更多
关键词 silver nanowires capacitive pressure sensor FLEXIBLE TRANSPARENT wearable electronics e-skin
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部