期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Optimal urban EV charging station site selection and capacity determination considering comprehensive benefits of vehicle-station-grid
1
作者 Hongwei Li Yufeng Song +4 位作者 Jiuding Tan Yi Cui Shuaibing Li Yongqiang Kang Haiying Dong 《iEnergy》 2024年第3期162-174,共13页
This paper presents an optimization model for the location and capacity of electric vehicle(EV)charging stations.The model takes the multiple factors of the“vehicle-station-grid”system into account.Then,ArcScene is ... This paper presents an optimization model for the location and capacity of electric vehicle(EV)charging stations.The model takes the multiple factors of the“vehicle-station-grid”system into account.Then,ArcScene is used to couple the road and power grid models and ensure that the coupling system is strictly under the goal of minimizing the total social cost,which includes the operator cost,user charging cost,and power grid loss.An immune particle swarm optimization algorithm(IPSOA)is proposed in this paper to obtain the optimal coupling strategy.The simulation results show that the algorithm has good convergence and performs well in solving multi-modal problems.It also balances the interests of users,operators,and the power grid.Compared with other schemes,the grid loss cost is reduced by 11.1%and 17.8%,and the total social cost decreases by 9.96%and 3.22%. 展开更多
关键词 EVS charging station site selection and capacity determination ArcScene immune particle swarm optimization algorithm(IPSOA) road electrical coupling
下载PDF
Two-Stage Planning of Distributed Power Supply and Energy Storage Capacity Considering Hierarchical Partition Control of Distribution Network with Source-Load-Storage
2
作者 Junhui Li Yuqing Zhang +4 位作者 Can Chen Xiaoxiao Wang Yinchi Shao Xingxu Zhu Cuiping Li 《Energy Engineering》 EI 2024年第9期2389-2408,共20页
Aiming at the consumption problems caused by the high proportion of renewable energy being connected to the distribution network,it also aims to improve the power supply reliability of the power system and reduce the ... Aiming at the consumption problems caused by the high proportion of renewable energy being connected to the distribution network,it also aims to improve the power supply reliability of the power system and reduce the operating costs of the power system.This paper proposes a two-stage planning method for distributed generation and energy storage systems that considers the hierarchical partitioning of source-storage-load.Firstly,an electrical distance structural index that comprehensively considers active power output and reactive power output is proposed to divide the distributed generation voltage regulation domain and determine the access location and number of distributed power sources.Secondly,a two-stage planning is carried out based on the zoning results.In the phase 1 distribution network-zoning optimization layer,the network loss is minimized so that the node voltage in the area does not exceed the limit,and the distributed generation configuration results are initially determined;in phase 2,the partition-node optimization layer is planned with the goal of economic optimization,and the distance-based improved ant lion algorithm is used to solve the problem to obtain the optimal distributed generation and energy storage systemconfiguration.Finally,the IEEE33 node systemwas used for simulation.The results showed that the voltage quality was significantly improved after optimization,and the overall revenue increased by about 20.6%,verifying the effectiveness of the two-stage planning. 展开更多
关键词 Zoning control two-stage planning site selection and capacity determination optimized scheduling improved ant lion algorithm
下载PDF
Determination of ultimate bearing capacity of uplift piles using intact and non-intact load−displacement curve 被引量:5
3
作者 WANG Qin-ke MAJian-lin +2 位作者 JI Yu-kun ZHANG Jian CHEN Wen-long 《Journal of Central South University》 SCIE EI CAS CSCD 2022年第2期470-485,共16页
Based on the field destructive test of six rock-socketed piles with shallow overburden,three prediction models are used to quantitatively analyze and predict the intact load−displacement curve.The predicted values of ... Based on the field destructive test of six rock-socketed piles with shallow overburden,three prediction models are used to quantitatively analyze and predict the intact load−displacement curve.The predicted values of ultimate uplift capacity were further determined by four methods(displacement controlling method(DCM),reduction coefficient method(RCM),maximum curvature method(MCM),and critical stiffness method(CSM))and compared with the measured value.Through the analysis of the relationship between the change rate of pullout stiffness and displacement,a method used to determine the ultimate uplift capacity via non-intact load−displacement curve was proposed.The results show that the predicted value determined by DCM is more conservative,while the predicted value determined by MCM is larger than the measured value.This suggests that RCM and CSM in engineering applications can be preferentially applied.Moreover,the development law of the change rate of pullout stiffness with displacement agrees well with the attenuation form of power function.The theoretical predicted results of ultimate uplift capacity based on the change rate of pullout stiffness will not be affected by the integrity of the curve.The method is simple and applicable for the piles that are not loaded to failure state,and thus provides new insights into ultimate uplift capacity determination of test piles. 展开更多
关键词 load−displacement curve prediction model determination method of bearing capacity change rate of pullout stiffness
下载PDF
Dispersed Wind Power Planning Method Considering Network Loss Correction with Cold Weather
4
作者 Hanpeng Kou Tianlong Bu +2 位作者 Leer Mao Yihong Jiao Chunming Liu 《Energy Engineering》 EI 2024年第4期1027-1048,共22页
In order to play a positive role of decentralised wind power on-grid for voltage stability improvement and loss reduction of distribution network,a multi-objective two-stage decentralised wind power planning method is... In order to play a positive role of decentralised wind power on-grid for voltage stability improvement and loss reduction of distribution network,a multi-objective two-stage decentralised wind power planning method is proposed in the paper,which takes into account the network loss correction for the extreme cold region.Firstly,an electro-thermal model is introduced to reflect the effect of temperature on conductor resistance and to correct the results of active network loss calculation;secondly,a two-stage multi-objective two-stage decentralised wind power siting and capacity allocation and reactive voltage optimisation control model is constructed to take account of the network loss correction,and the multi-objective multi-planning model is established in the first stage to consider the whole-life cycle investment cost of WTGs,the system operating cost and the voltage quality of power supply,and the multi-objective planning model is established in the second stage.planning model,and the second stage further develops the reactive voltage control strategy of WTGs on this basis,and obtains the distribution network loss reduction method based on WTG siting and capacity allocation and reactive power control strategy.Finally,the optimal configuration scheme is solved by the manta ray foraging optimisation(MRFO)algorithm,and the loss of each branch line and bus loss of the distribution network before and after the adoption of this loss reduction method is calculated by taking the IEEE33 distribution system as an example,which verifies the practicability and validity of the proposed method,and provides a reference introduction for decision-making for the distributed energy planning of the distribution network. 展开更多
关键词 Decentralised wind power network loss correction siting and capacity determination reactive voltage control two-stage model manta ray foraging optimisation algorithm
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部