Fused-silica capillaries used in capillary zone electrophoresis were statically coated with γ- glycidoxypropyltrimethoxysilane and epoxy polymer in order to suppress wall adsorption in the separation of proteins. It ...Fused-silica capillaries used in capillary zone electrophoresis were statically coated with γ- glycidoxypropyltrimethoxysilane and epoxy polymer in order to suppress wall adsorption in the separation of proteins. It has been shown that a significant decrease in adsorption was obtained and eletroosmotic flow was the diminished in the pH range 3-5. However with higher pH values, appreciable peak deformation and decreases in the resolving power were observed. Under pH 5, the epoxy polymer coating was shown to be quite stable and exhibited reproducible separations from run-to-run and day-to-day over a period of time.展开更多
Spontaneous imbibition(SI)is an important mechanism for enhancing oil recovery in low-permeability reservoirs.Due to the strong heterogeneity,and the non-Darcy flow,the construction of SI model for lowpermeability res...Spontaneous imbibition(SI)is an important mechanism for enhancing oil recovery in low-permeability reservoirs.Due to the strong heterogeneity,and the non-Darcy flow,the construction of SI model for lowpermeability reservoirs is extremely challenging.Commonly,traditional SI models based on single or averaged capillary tortuosity ignore the influence of heterogeneity of pore seepage channels and the threshold pressure(TP)on imbibition.Therefore,in this work,based on capillary model and fractal theory,a mathematical model of characterizing SI considering heterogeneity of pore seepage channels is established.On this basis,the threshold pressure was introduced to determine the pore radius at which the wetted phase can displace oil.The proposed new SI model was verified by imbibition experimental data.The study shows that for weakly heterogeneous cores with permeability of 0-1 m D,the traditional SI model can characterize the imbibition process relatively accurately,and the new imbibition model can increase the coefficient of determination by 1.05 times.However,traditional model has serious deviations in predicting the imbibition recovery for cores with permeability of 10-50 m D.The new SI model coupling with heterogeneity of pore seepage channels and threshold pressure effectively solves this problem,and the determination coefficient is increased from 0.344 to 0.922,which is increased by2.68 times.For low-permeability reservoirs,the production of the oil in transitional pores(0.01-0.1μm)and mesopores(0.1-1μm)significantly affects the imbibition recovery,as the research shows that when the heterogeneity of pore seepage channels is ignored,the oil recovery in transitional pores and mesopores decreases by 7.54%and 4.26%,respectively.Sensitivity analysis shows that increasing interfacial tension,decreasing contact angle,oil-water viscosity ratio and threshold pressure will increase imbibition recovery.In addition,there are critical values for the influence of these factors on the imbibition recovery,which provides theoretical support for surfactant optimization.展开更多
Purpose: To evaluate optical coherence tomography angiography (OCT-A) data obtained from the superficial retinal capillary plexus of patients with retinal vein occlusion and comparative analysis with data registered f...Purpose: To evaluate optical coherence tomography angiography (OCT-A) data obtained from the superficial retinal capillary plexus of patients with retinal vein occlusion and comparative analysis with data registered from unaffected fellow eyes. Methods: The examined patients were classified into 2 groups: group 1—eyes with established retinal vein occlusion (n = 29) and group 2—unaffected fellow eyes of patients with retinal vein occlusion (n = 24). The scanning protocol “Angiography 3 × 3 mm” of Zeiss Cirrus HD-OCT 6000, AngioPlex Metrix was used to evaluate the retinal superficial capillary plexus. The analyzed parameters were vascular density and perfusion density, as well as the area, perimeter, and circularity of the foveolar avascular zone (FAZ). Results: The comparative analysis of FAZ parameters at the superficial capillary plexus (SCP) between group 1 (eyes with retinal vein occlusion) and group 2 (unaffected fellow eyes) showed significant results for the three parameters, respectively area (p = 0.003), perimeter (p ≤ 0.001), and circularity (p = 0.011) of FAZ. The comparative analysis of the vascular network at SCP in patients with diagnosed retinal vein occlusion and unaffected fellow eyes showed significant results for vascular density (VD) in the central (p = 0.038) and inner (p ≤ 0.001) zones as well as total VD (p ≤ 0.001) were statistically significant. Moreover, the results obtained in the study of vascular perfusion (VP) indicated significant results in the inner zone (p ≤ 0.001) and total VP (p = 0.001). Vascular perfusion in the central zone (p = 0.116) was the only parameter not to meet significant results. Conclusion: The current study observed a significant enlargement of the FAZ and loss of its circularity, along with a reduction in vascular network parameters at the superficial retinal capillary plexus level.展开更多
文摘Fused-silica capillaries used in capillary zone electrophoresis were statically coated with γ- glycidoxypropyltrimethoxysilane and epoxy polymer in order to suppress wall adsorption in the separation of proteins. It has been shown that a significant decrease in adsorption was obtained and eletroosmotic flow was the diminished in the pH range 3-5. However with higher pH values, appreciable peak deformation and decreases in the resolving power were observed. Under pH 5, the epoxy polymer coating was shown to be quite stable and exhibited reproducible separations from run-to-run and day-to-day over a period of time.
基金supported by China Natural Science Foundation(Grant No.52274053)Beijing Natural Science Foundation(Grant No.3232028)Open Fund of State Key Laboratory of Offshore Oil Exploitation(Grant No.CCL2021RCPS0515KQN)。
文摘Spontaneous imbibition(SI)is an important mechanism for enhancing oil recovery in low-permeability reservoirs.Due to the strong heterogeneity,and the non-Darcy flow,the construction of SI model for lowpermeability reservoirs is extremely challenging.Commonly,traditional SI models based on single or averaged capillary tortuosity ignore the influence of heterogeneity of pore seepage channels and the threshold pressure(TP)on imbibition.Therefore,in this work,based on capillary model and fractal theory,a mathematical model of characterizing SI considering heterogeneity of pore seepage channels is established.On this basis,the threshold pressure was introduced to determine the pore radius at which the wetted phase can displace oil.The proposed new SI model was verified by imbibition experimental data.The study shows that for weakly heterogeneous cores with permeability of 0-1 m D,the traditional SI model can characterize the imbibition process relatively accurately,and the new imbibition model can increase the coefficient of determination by 1.05 times.However,traditional model has serious deviations in predicting the imbibition recovery for cores with permeability of 10-50 m D.The new SI model coupling with heterogeneity of pore seepage channels and threshold pressure effectively solves this problem,and the determination coefficient is increased from 0.344 to 0.922,which is increased by2.68 times.For low-permeability reservoirs,the production of the oil in transitional pores(0.01-0.1μm)and mesopores(0.1-1μm)significantly affects the imbibition recovery,as the research shows that when the heterogeneity of pore seepage channels is ignored,the oil recovery in transitional pores and mesopores decreases by 7.54%and 4.26%,respectively.Sensitivity analysis shows that increasing interfacial tension,decreasing contact angle,oil-water viscosity ratio and threshold pressure will increase imbibition recovery.In addition,there are critical values for the influence of these factors on the imbibition recovery,which provides theoretical support for surfactant optimization.
文摘Purpose: To evaluate optical coherence tomography angiography (OCT-A) data obtained from the superficial retinal capillary plexus of patients with retinal vein occlusion and comparative analysis with data registered from unaffected fellow eyes. Methods: The examined patients were classified into 2 groups: group 1—eyes with established retinal vein occlusion (n = 29) and group 2—unaffected fellow eyes of patients with retinal vein occlusion (n = 24). The scanning protocol “Angiography 3 × 3 mm” of Zeiss Cirrus HD-OCT 6000, AngioPlex Metrix was used to evaluate the retinal superficial capillary plexus. The analyzed parameters were vascular density and perfusion density, as well as the area, perimeter, and circularity of the foveolar avascular zone (FAZ). Results: The comparative analysis of FAZ parameters at the superficial capillary plexus (SCP) between group 1 (eyes with retinal vein occlusion) and group 2 (unaffected fellow eyes) showed significant results for the three parameters, respectively area (p = 0.003), perimeter (p ≤ 0.001), and circularity (p = 0.011) of FAZ. The comparative analysis of the vascular network at SCP in patients with diagnosed retinal vein occlusion and unaffected fellow eyes showed significant results for vascular density (VD) in the central (p = 0.038) and inner (p ≤ 0.001) zones as well as total VD (p ≤ 0.001) were statistically significant. Moreover, the results obtained in the study of vascular perfusion (VP) indicated significant results in the inner zone (p ≤ 0.001) and total VP (p = 0.001). Vascular perfusion in the central zone (p = 0.116) was the only parameter not to meet significant results. Conclusion: The current study observed a significant enlargement of the FAZ and loss of its circularity, along with a reduction in vascular network parameters at the superficial retinal capillary plexus level.