期刊文献+
共找到810篇文章
< 1 2 41 >
每页显示 20 50 100
Reservoir quality evaluation of the Narimba Formation in Bass Basin,Australia:Implications from petrophysical analysis,sedimentological features,capillary pressure and wetting fluid saturation 被引量:1
1
作者 Wafa Abdul Qader Al-Ojaili Mohamed Ragab Shalaby Wilfried Bauer 《Energy Geoscience》 EI 2024年第1期37-53,共17页
The evaluation of reservoir quality was accomplished on the Late Paleocene to Early Eocene Narimba Formation in Bass Basin,Australia.This study involved combination methods such as petrophysical analysis,petrography a... The evaluation of reservoir quality was accomplished on the Late Paleocene to Early Eocene Narimba Formation in Bass Basin,Australia.This study involved combination methods such as petrophysical analysis,petrography and sedimentological studies,reservoir quality and fluid flow units from derivative parameters,and capillary pressure and wetting fluid saturation relationship.Textural and diagenetic features are affecting the reservoir quality.Cementation,compaction,and presence of clay minerals such as kaolinite are found to reduce the quality while dissolution and secondary porosity are noticed to improve it.It is believed that the Narimba Formation is a potential reservoir with a wide range of porosity and permeability.Porosity ranges from 3.1%to 25.4%with a mean of 15.84%,while permeability ranges between 0.01 mD and 510 mD,with a mean of 31.05 mD.Based on the heterogenous lithology,the formation has been categorized into five groups based on permeability variations.Group I showed an excellent to good quality reservoir with coarse grains.The impacts of both textural and diagenetic features improve the reservoir and producing higher reservoir quality index(RQI)and flow zone indicators(FZI)as well as mostly mega pores.The non-wetting fluid migration has the higher possibility to flow in the formation while displacement pressure recorded as zero.Group II showed a fair quality reservoir with lower petrophysical properties in macro pores.The irreducible water saturation is increasing while the textural and digenetic properties are still enhancing the reservoir quality.Group III reflects lower quality reservoir with mostly macro pores and higher displacement pressure.It may indicate smaller grain size and increasing amount of cement and clay minerals.Group IV,and V are interpreted as a poor-quality reservoir that has lower RQI and FZI.The textural and digenetic features are negatively affecting the reservoir and are leading to smaller pore size and pore throat radii(r35)values to be within the range of macro,meso-,micro-,and nano pores.The capillary displacement pressure curves of the three groups show increases reaching the maximum value of 400 psia in group V.Agreement with the classification of permeability,r35 values,and pore type can be used in identifying the quality of reservoir. 展开更多
关键词 Narimba formation PETROPHYSICS Reservoir quality capillary pressure Wetting fluid saturation
下载PDF
A new interacting capillary bundle model on the multiphase flow in micropores of tight rocks
2
作者 Wen-Quan Deng Tian-Bo Liang +3 位作者 Wen-Zhong Wang Hao Liu Jun-Lin Wu Fu-Jian Zhou 《Petroleum Science》 SCIE EI CAS CSCD 2024年第2期1099-1112,共14页
Surfactants are widely used in the fracturing fluid to enhance the imbibition and thus the oil recovery rate. However, current numerical models cannot capture the physics behind capillary imbibition during the wettabi... Surfactants are widely used in the fracturing fluid to enhance the imbibition and thus the oil recovery rate. However, current numerical models cannot capture the physics behind capillary imbibition during the wettability alteration by surfactants. Although the interacting capillary bundle(ICB) model shows potential in characterizing imbibition rates in different pores during wettability alteration, the existing ICB models neglect the influence of wettability and viscosity ratio on the imbibition behavior, making it difficult to accurately describe the oil-water imbibition behavior within the porous media. In this work,a new ICB mathematical model is established by introducing pressure balance without assuming the position of the leading front to comprehensively describe the imbibition behavior in a porous medium under different conditions, including gas-liquid spontaneous imbibition and oil-water imbibition.When the pore size distribution of a tight rock is known, this new model can predict the changes of water saturation during the displacement process in the tight rock, and also determine the imbibition rate in pores of different sizes. The water saturation profiles obtained from the new model are validated against the waterflooding simulation results from the CMG, while the imbibition rates calculated by the model are validated against the experimental observations of gas-liquid spontaneous imbibition. The good match above indicates the newly proposed model can show the water saturation profile at a macroscopic scale while capture the underlying physics of the multiphase flow in a porous medium at a microscopic scale. Simulation results obtained from this model indicate that both wettability and viscosity ratio can affect the sequence of fluid imbibition into pores of different sizes during the multiphase flow, where less-viscous wetting fluid is preferentially imbibed into larger pores while more-viscous wetting fluid tends to be imbibed into smaller pores. Furthermore, this model provides an avenue to calculate the imbibition rate in pores of different sizes during wettability alteration and capture the non-Darcy effect in micro-and nano-scale pores. 展开更多
关键词 Imbibition Multiphase flow Tight rock Interacting capillary bundle model Wettability
下载PDF
Capillary Property of Entangled Porous Metallic Wire materials and Its Application in Fluid Buffers:Theoretical Analysis and Experimental Study
3
作者 Yu Tang Yiwan Wu +1 位作者 Hu Cheng Rong Liu 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第1期400-416,共17页
Strong impact does serious harm to the military industries so it is necessary to choose reasonable cushioning material and design effective buffers to prevent the impact of equipment.Based on the capillary property en... Strong impact does serious harm to the military industries so it is necessary to choose reasonable cushioning material and design effective buffers to prevent the impact of equipment.Based on the capillary property entangled porous metallic wire materials(EPMWM),this paper designed a composite buffer which uses EPMWM and viscous fluid as cushioning materials under the low-speed impact of the recoil force device of weapon equipment(such as artillery,mortar,etc.).Combined with the capillary model,porosity,hydraulic diameter,maximum pore diameter and pore distribution were used to characterize the pore structure characteristics of EPMWM.The calculation model of the damping force of the composite buffer was established.The low-speed impact test of the composite buffer was conducted.The parameters of the buffer under low-speed impact were identified according to the model,and the nonlinear model of damping force was obtained.The test results show that the composite buffer with EPMWM and viscous fluid can absorb the impact energy from the recoil movement effectively,and provide a new method for the buffer design of weapon equipment(such as artillery,mortar,etc.). 展开更多
关键词 Entangled porous metallic wire materials capillary property Viscousfluid Low-speed impact Damping force
下载PDF
Exploring Capillary Fringe Flow:Quasilinear Modeling with Kirchhoff Transforms and Gardner Model
4
作者 Rachid Karra Abdelatif Maslouhi 《Fluid Dynamics & Materials Processing》 EI 2024年第7期1611-1631,共21页
Recent studies have underscored the significance of the capillary fringe in hydrological and biochemical processes.Moreover,its role in shallow waters is expected to be considerable.Traditionally,the study of groundwa... Recent studies have underscored the significance of the capillary fringe in hydrological and biochemical processes.Moreover,its role in shallow waters is expected to be considerable.Traditionally,the study of groundwater flow has centered on unsaturated-saturated zones,often overlooking the impact of the capillary fringe.In this study,we introduce a steady-state two-dimensional model that integrates the capillary fringe into a 2-D numerical solution.Our novel approach employs the potential form of the Richards equation,facilitating the determination of boundaries,pressures,and velocities across different ground surface zones.We utilized a two-dimensional Freefem++finite element model to compute the stationary solution.The validation of the model was conducted using experimental data.We employed the OFAT(One_Factor-At-Time)method to identify the most sensitive soil parameters and understand how changes in these parameters may affect the behavior and water dynamics of the capillary fringe.The results emphasize the role of hydraulic conductivity as a key parameter influencing capillary fringe shape and dynamics.Velocity values within the capillary fringe suggest the prevalence of horizontal flow.By variation of the water table level and the incoming flow q0,we have shown the correlation between water table elevation and the upper limit of the capillary fringe. 展开更多
关键词 capillary fringe Freefem++ gardner model modeling porous media
下载PDF
Microvascular structural changes in esophageal squamous cell carcinoma pathology according to intrapapillary capillary loop types under magnifying endoscopy
5
作者 Wei-Yang Shu Yan-Yan Shi +5 位作者 Jiu-Tian Huang Ling-Mei Meng He-Jun Zhang Rong-Li Cui Yuan Li Shi-Gang Ding 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第8期3471-3480,共10页
BACKGROUND The intrapapillary capillary loop(IPCL)characteristics,visualized using magnifying endoscopy,are commonly assessed for preoperative evaluation of the infiltration depth of esophageal squamous cell carcinoma... BACKGROUND The intrapapillary capillary loop(IPCL)characteristics,visualized using magnifying endoscopy,are commonly assessed for preoperative evaluation of the infiltration depth of esophageal squamous cell carcinoma(ESCC).Japan Esophageal Society(JES)classification is the most widely used classification.Microvascular structural changes are evaluated by magnifying endoscopy for the presence or absence of each morphological factor:tortuosity,dilatation,irregular caliber,and different shapes.However,the pathological characteristics of IPCLs have not been thoroughly investigated,especially the microvascular structures corresponding to the deepest parts of the lesions'infiltration.AIM To investigate differences in pathological microvascular structures of ESCC,which correspond to the deepest parts of the lesions'infiltration.METHODS Patients with ESCC and precancerous lesions diagnosed at Peking University Third Hospital were enrolled between January 2019 and April 2023.Patients first underwent magnified endoscopic examination,followed by endoscopic submucosal dissection or surgical treatment.Pathological images were scanned using a threedimensional slice scanner,and the pathological structural differences in different types,according to the JES classification,were analyzed using nonparametric tests and t-tests.RESULTS The 35 lesions were divided into four groups according to the JES classification:A,B1,B2,and B3.Statistical analyses revealed significant differences(aP<0.05)in the short and long calibers,area,location,and density between types A and B.Notably,there were no significant differences in these parameters between types B1 and B2 and between types B2 and B3(P>0.05).However,significant differences in the short calibers,long calibers,and area of IPCL were observed between types B1 and B3(aP<0.05);no significant differences were found in the density or location(P>0.05).CONCLUSION Pathological structures of IPCLs in the deepest infiltrating regions differ among various IPCL types classified by the JES classification under magnifying endoscopy,especially between the types A and B. 展开更多
关键词 Esophageal squamous cell carcinoma Intrapapillary capillary loop The Japan Esophageal Society classification Magnifying endoscopy Pathological characteristics
下载PDF
Comparative Quantitative Analysis of Retinal Superficial Capillary Plexus in Patients with Retinal Vein Occlusion and Unaffected Fellow Eyes
6
作者 Sinan Aptikadir Nelly Sivkova 《Open Journal of Ophthalmology》 2024年第3期218-228,共11页
Purpose: To evaluate optical coherence tomography angiography (OCT-A) data obtained from the superficial retinal capillary plexus of patients with retinal vein occlusion and comparative analysis with data registered f... Purpose: To evaluate optical coherence tomography angiography (OCT-A) data obtained from the superficial retinal capillary plexus of patients with retinal vein occlusion and comparative analysis with data registered from unaffected fellow eyes. Methods: The examined patients were classified into 2 groups: group 1—eyes with established retinal vein occlusion (n = 29) and group 2—unaffected fellow eyes of patients with retinal vein occlusion (n = 24). The scanning protocol “Angiography 3 × 3 mm” of Zeiss Cirrus HD-OCT 6000, AngioPlex Metrix was used to evaluate the retinal superficial capillary plexus. The analyzed parameters were vascular density and perfusion density, as well as the area, perimeter, and circularity of the foveolar avascular zone (FAZ). Results: The comparative analysis of FAZ parameters at the superficial capillary plexus (SCP) between group 1 (eyes with retinal vein occlusion) and group 2 (unaffected fellow eyes) showed significant results for the three parameters, respectively area (p = 0.003), perimeter (p ≤ 0.001), and circularity (p = 0.011) of FAZ. The comparative analysis of the vascular network at SCP in patients with diagnosed retinal vein occlusion and unaffected fellow eyes showed significant results for vascular density (VD) in the central (p = 0.038) and inner (p ≤ 0.001) zones as well as total VD (p ≤ 0.001) were statistically significant. Moreover, the results obtained in the study of vascular perfusion (VP) indicated significant results in the inner zone (p ≤ 0.001) and total VP (p = 0.001). Vascular perfusion in the central zone (p = 0.116) was the only parameter not to meet significant results. Conclusion: The current study observed a significant enlargement of the FAZ and loss of its circularity, along with a reduction in vascular network parameters at the superficial retinal capillary plexus level. 展开更多
关键词 Retinal Vein Occlusion Optical Coherence Tomography Angiography Superficial Retinal capillary Plexus
下载PDF
Recent applications and chiral separation development based on stationary phases in open tubular capillary electrochromatography(2019–2022) 被引量:1
7
作者 Xinyu Li Qianjie Ma +2 位作者 Xiangtai Zheng Qin Chen Xiaodong Sun 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2023年第4期323-339,共17页
Capillary electrochromatography(CEC)plays a significant role in chiral separation via the double separation principle,partition coefficient difference between the two phases,and electroosmotic flow-driven separation.G... Capillary electrochromatography(CEC)plays a significant role in chiral separation via the double separation principle,partition coefficient difference between the two phases,and electroosmotic flow-driven separation.Given the distinct properties of the inner wall stationary phase(SP),the separation ability of each SP differs from one another.Particularly,it provides large room for promising applications of open tubular capillary electrochromatography(OT-CEC).We divided the OT-CEC SPs developed over the past four years into six types:ionic liquids,nanoparticle materials,microporous materials,biomaterials,non-nanopolymers,and others,to mainly introduce their characteristics in chiral drug separation.There also added a few classic SPs that occurred within ten years as supplements to enrich the features of each SP.Additionally,we discuss their applications in metabolomics,food,cosmetics,environment,and biology as analytes in addition to chiral drugs.OT-CEC plays an increasingly significant role in chiral separation and may promote the development of capillary electrophoresis(CE)combined with other instruments in recent years,such as CE with mass spectrometry(CE/MS)and CE with ultraviolet light detector(CE/UV). 展开更多
关键词 capillary electrochromatography Open tubular capillary Chiral separation Stationary phase capillary electrophoresis with mass spectrometry(CE/MS)
下载PDF
Experimental study on height simulation of capillary fringe
8
作者 ZHANG Bing GAO Ye-xin +3 位作者 FENG Xin ZHANG Ya-zhe LIU Ji-chao ZHANG Ying-ping 《Journal of Groundwater Science and Engineering》 2020年第2期108-117,共10页
In this paper, the plexiglass experimental column was used to analyze the capillary fringe thickness of three kinds of lithologies-silty sand, silt and silty clay-providing a basis for defining the interface in the st... In this paper, the plexiglass experimental column was used to analyze the capillary fringe thickness of three kinds of lithologies-silty sand, silt and silty clay-providing a basis for defining the interface in the study of hydrodynamics at the water table between vandose water and groundwater. The capillary fringe generally refers to the subsurface layer in which the groundwater seeps up to the air-entry suction value due to capillary action, and is nearly saturated with water. The thickness of the capillary fringe varies with different lithologies. In this experiment, self-made stable water supply devices were used to study the height of capillary rise, capillary water volume and capillary fringe thickness of the three lithologies through capillary experiment and numerical simulation. Experimental results show as follows:(1) Rising height of capillary water is related to time, particle radius, volume, etc., and the relationship between height and time is in line with the Hill model.(2) The smaller the particle radius, the more water the pores contain, and the ratio of the unsaturated portion of capillary water to the total water content gradually rises. Experimental results obtained by numerical simulation, segmentation and actual measurement are consistent.(3) The thickness of the capillary zone is related to the lithology. The larger the particle size, the smaller the thickness of the capillary fringe, and vice versa. In silty sand, the thickness measures about 13 cm. The figure rises to 16 cm in silt, and 37 cm in silty clay. This work studies the law of soil water transport at saturated-unsaturated interface. Experimental results are of great significance to the study of soil water and salt transport and soil salinization control in unsaturated zone. 展开更多
关键词 capillary Height of rise capillary water content capillary fringe Hill simulation
下载PDF
Effect of ore size and heap porosity on capillary process inside leaching heap 被引量:10
9
作者 尹升华 王雷鸣 +1 位作者 陈勋 吴爱祥 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2016年第3期835-841,共7页
The capillary process coexists with gravity flow within leaching heap due to the dual-porosity structure. Capillary rise is responsible for the mineral dissolution in fine particle zones and interior coarse rock. The ... The capillary process coexists with gravity flow within leaching heap due to the dual-porosity structure. Capillary rise is responsible for the mineral dissolution in fine particle zones and interior coarse rock. The effect of particle size and heap porosity on the capillary process was investigated through a series of column tests. Macropore of the ore heap was identified, and its capillary rise theory analysis was put forward. Two groups of ore particles, mono-size and non-uniform, were selected for the capillary rise test. The result shows that particle size has an inverse effect on the capillary ultimate height, and smaller particles exhibit higher capillary rise. Meanwhile, the poorly graded group exhibits small rise height and velocity, while the capillary rise in the well-graded particles is much greater. The relationship between porosity and fitting parameters of capillary rise was obtained. Low porosity and high surface tension lead to higher capillary height of the fine gradation. Moisture content increases with the capillary rise level going up, the relationship between capillary height and moisture content was obtained. 展开更多
关键词 heap leaching capillary process ore size heap porosity
下载PDF
Capillarys 2 Flex Piercing糖化血红蛋白检测系统的综合评估 被引量:5
10
作者 徐安平 纪玲 +5 位作者 陈卫东 夏勇 黄静之 喻晶 周宇 李璐 《检验医学》 CAS 2016年第2期123-127,共5页
目的综合评估基于毛细管电泳法的Capillarys 2 Flex Piercing糖化血红蛋白(Hb A1c)检测系统。方法验证Capillarys 2 Flex Piercing Hb A1c检测系统的相关性、精密度和线性范围等基本性能指标,并采用干扰实验评价其抗干扰能力,项目包... 目的综合评估基于毛细管电泳法的Capillarys 2 Flex Piercing糖化血红蛋白(Hb A1c)检测系统。方法验证Capillarys 2 Flex Piercing Hb A1c检测系统的相关性、精密度和线性范围等基本性能指标,并采用干扰实验评价其抗干扰能力,项目包括胆红素(Bil)、甘油三酯(TG)、血红蛋白(Hb)、不稳定糖化血红蛋白(LA1c)、Hb F和广东地区常见的Hb变异体(Hb E、Hb J-Bangkok、Hb New York、Hb G-Taipei和Hb G-Coushatta)。采用Capillarys 2 Flex Piercing Hb A1c检测系统检测Hb A2,评价其与毛细管电泳法的相关性;采用Capillarys 2 Flex Piercing Hb A1c检测系统测定40份美国国家糖化血红蛋白标准化计划(NGSP)Hb A1c临床实验室认证样本,分析其与NGSP参考实验室结果的差异,验证正确度。结果 Capillarys 2 Flex Piercing Hb A1c检测系统与VariantⅡTurbo 2.0 Hb A1c分析仪的相关性良好(r=0.997,P=0.000);总精密度[变异系数(CV)]〈2.00%;Hb A1c在3.8%~17.1%范围内呈线性;当Bil≤355μmol/L、TG≤25.3 mmol/L、Hb为28~182 g/L、LA1c为1.2%~7.8%、Hb F≤22.3%时不受干扰;能分离广东地区常见的Hb变异体(Hb E、Hb J-Bangkok、Hb New York、Hb G-Taipei和Hb G-Coushatta)。Capillarys 2 Flex Piercing Hb A1c检测系统检测Hb A2和毛细管电泳法相关性良好(r=0.993,P=0.000);与NGSP参考实验室结果的偏差均〈6%。结论 Capillarys 2 Flex Piercing Hb A1c检测系统完全能满足临床需求,可同时提供Hb A2的结果用于地中海贫血的筛查,是一种多用途的Hb A1c检测系统。 展开更多
关键词 糖化血红蛋白 毛细管电泳法 capillarys 2 FLEX Piercing糖化血红蛋白检测系统 美国国家糖化血红蛋白标准化计划
下载PDF
Capillary Electrochromatography Using C_8 Open Tubular Column Prepared by Sol-Gel Technique 被引量:1
11
作者 李方 靳慧 +1 位作者 顾峻岭 傅若农 《Journal of Beijing Institute of Technology》 EI CAS 1996年第2期122-122,共1页
Open tubthar C8 columns were prepared by sol-gel technology and used in the electrochromatographic separations.
关键词 SOL-GEL technology OPEN TUBULAR capillary COLUMN capillary ELECTROCHROMATOGRAPHY
下载PDF
Interactions Between Thrombin and Natural Proudcts of Coreopsis tinctoria Nuttt. and Cistanche deserticola Ma. in Capillary Zone Electrophoresis 被引量:1
12
作者 刘一 张媛 +3 位作者 刘晓明 凌笑梅 屠鹏飞 崔景荣 《Journal of Chinese Pharmaceutical Sciences》 CAS 2006年第1期38-44,共7页
Aim A capillary zone electrophoretic method (CZE) was used to determine the interactions between natural products and thrombin. Methods Samples containing natural products and thrombin at various ratios were incubat... Aim A capillary zone electrophoretic method (CZE) was used to determine the interactions between natural products and thrombin. Methods Samples containing natural products and thrombin at various ratios were incubated at 25 ℃ and then were separated by CZE with Tris-acetate buffer at pH 7.2. Each run could be accomplished within 5 min. Results In CZE, the peak width broadened due to the affinity interaction between natural products and thrombin. Compared with positive and negative control, the natural products (CB-1, CB-2) from Coreopsis tinctoria Nuttt. interacted with thrombin; CB-3 from Coreopsis tinctoria Nuttt. and HC-1, HC-2, HC-3 from Cistanche deserticola Ma. did not bind to thrombin. Both qualification and quantification characterizations of the binding were determined. Conclusion The established method is capable of sensitive and fast determination of natural products and thrombin interactions, it can be employed as an alternative method. 展开更多
关键词 capillary zone electrophoresis Coreopsis tinctoria Nuttt. Cistanche deserticola Ma INTERACTIONS THROMBIN
下载PDF
Determination of Dichlofluanid Residue in Soybean by Capillary Collumns Gas Chromatography 被引量:20
13
作者 邵栋梁 《Agricultural Science & Technology》 CAS 2010年第3期7-8,64,共3页
A method for the determination of dichlofluanid residue by Capillary Collumns Gas Chromatography was established in this study.Samples were extracted with acetone and subjected to through liquid-liquid extraction with... A method for the determination of dichlofluanid residue by Capillary Collumns Gas Chromatography was established in this study.Samples were extracted with acetone and subjected to through liquid-liquid extraction with N-hexane,and then they were cleanup with column that filled with florisil,subsequently separated by Capillary Column Gas Chromatography,and the electron capture detector (ECD) was used for detection.The detection limit of this method was 0.005 mg/kg (S/N=3),and this method was rapid,sensitive and accurate,and was applied in the determination of dichlofluanid residue in soybean. 展开更多
关键词 Dichlofluanid capillary Collumns Gas Chromatography SOYBEAN
下载PDF
Capillary Zone Electrophoretic Separation of Proteins in Polymer Coated Capillaries 被引量:1
14
作者 刘玉 顾俊岭 傅若农 《Journal of Beijing Institute of Technology》 EI CAS 1995年第2期155+148-155,共9页
Fused-silica capillaries used in capillary zone electrophoresis were statically coated with γ- glycidoxypropyltrimethoxysilane and epoxy polymer in order to suppress wall adsorption in the separation of proteins. It ... Fused-silica capillaries used in capillary zone electrophoresis were statically coated with γ- glycidoxypropyltrimethoxysilane and epoxy polymer in order to suppress wall adsorption in the separation of proteins. It has been shown that a significant decrease in adsorption was obtained and eletroosmotic flow was the diminished in the pH range 3-5. However with higher pH values, appreciable peak deformation and decreases in the resolving power were observed. Under pH 5, the epoxy polymer coating was shown to be quite stable and exhibited reproducible separations from run-to-run and day-to-day over a period of time. 展开更多
关键词 PROTEINS SEPARATION COATING capillary electrophoresis
下载PDF
A new method to construct reservoir capillary pressure curves using NMR log data and its application 被引量:5
15
作者 肖亮 张伟 《Applied Geophysics》 SCIE CSCD 2008年第2期92-98,共7页
By analyzing hundreds of capillary pressure curves, the controlling factors of shape and type of capillary pressure curves are found and a novel method is presented to construct capillary pressure curves by using rese... By analyzing hundreds of capillary pressure curves, the controlling factors of shape and type of capillary pressure curves are found and a novel method is presented to construct capillary pressure curves by using reservoir permeability and a synthesized index. The accuracy of this new method is verified by mercury-injection experiments. Considering the limited quantity of capillary pressure data, a new method is developed to extract the Swanson parameter from the NMR T2 distribution and estimate reservoir permeability. Integrating with NMR total porosity, reservoir capillary pressure curves can be constructed to evaluate reservoir pore structure in the intervals with NMR log data. An in-situ example of evaluating reservoir pore structure using the capillary pressure curves by this new method is presented. The result shows that it accurately detects the change in reservoir pore structure as a function of depth. 展开更多
关键词 NMR log pore structure Swanson parameter synthesized index capillary pressure curves
下载PDF
Recent advances in screening of enzymes inhibitors based on capillary electrophoresis 被引量:5
16
作者 Mengxia Cheng Zilin Chen 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2018年第4期226-233,共8页
Capillary electrophoresis with many advantages plays an important role in pharmaceutical analysis and drug screening. This review gives an overview on the recent advances in the developments and applications of capill... Capillary electrophoresis with many advantages plays an important role in pharmaceutical analysis and drug screening. This review gives an overview on the recent advances in the developments and applications of capillary electrophoresis in the field of enzyme inhibitor screening. The period covers 2013 to 2017. Both the pre-capillary enzyme assays and in-capillary enzyme assays which include electrophoretically mediated microanalysis(EMMA) and immobilized enzyme microreactor(IMER) are summarized in this article. 展开更多
关键词 capillary electrophoresis Enzyme inhibitor screening Pre-capillary enzyme assays Electrophoretically mediated microanalysis Immobilized enzyme microreactor
下载PDF
Capillary force of a novel skew-grooved wick structure for micro heat pipes 被引量:2
17
作者 吴菊红 汤勇 陆龙生 《Journal of Central South University》 SCIE EI CAS 2011年第6期2170-2175,共6页
In order to improve the capillary force of grooved wick, a novel skew-grooved wick structure was proposed for micro heat pipes. Risen meniscus experiments were carried out to research the capillary force of the skew-g... In order to improve the capillary force of grooved wick, a novel skew-grooved wick structure was proposed for micro heat pipes. Risen meniscus experiments were carried out to research the capillary force of the skew-grooved and rectangle-grooved wick and a comparison of capillarity between the two wick structures was explored. A theoretical capillary force model of skew-grooved wick structure was also developed to calculate its effective capillary radius by comparing with the rectangle-grooved wick. From the experimental results, the maximum capillary force of the skewed-grooved wick is 8.62% larger than that of the rectangle-grooved wick. From the theoretical analysis, because the skewed-grooved wick has a smaller effective capillary radius, its maximum capillary force is 8.64% larger than that of the rectangle-grooved wick. The results indicate that the skew-grooved wick provides larger capillary force than the rectangle-grooved wick. 展开更多
关键词 skew-grooved wick micro heat pipe capillary force effective capillary radius
下载PDF
Determination of dynamic capillary effect on two-phase flow in porous media: A perspective from various methods 被引量:2
18
作者 Jian-Chao Cai Yin Chen +3 位作者 Jun-Cheng Qiao Liu Yang Jian-Hui Zeng Chen-Hao Sun 《Petroleum Science》 SCIE CAS CSCD 2022年第4期1641-1652,共12页
The relationship between capillary pressure and saturation plays a critical role in the characterization of two-phase flow and transport in aquifers and oil reservoirs. This relationship is usually determined under th... The relationship between capillary pressure and saturation plays a critical role in the characterization of two-phase flow and transport in aquifers and oil reservoirs. This relationship is usually determined under the static condition, where capillary pressure is the only function of saturation. However,considerable experiments have suggested that the dependence of capillary pressure on desaturation rate is under the dynamic condition. Thus, a more general description of capillary pressure that includes dynamic capillary effect has been approved widely. A comprehensive understanding of the dynamic capillary effect is needed for the investigation of the two-phase flow in porous media by various methods. In general, dynamic capillary effect in porous media can be studied through the laboratory experiment, pore-to macro-scale modeling, and artificial neural network. Here, main principle and research procedures of each method are reviewed in detail. Then, research progress, disadvantages and advantages are discussed, respectively. In addition, upscaling study from pore-to macro-scale are introduced, which explains the difference between laboratory experiment and pore-scale modeling. At last, several future perspectives and recommendations for optimal solution of dynamic capillary effect are presented. 展开更多
关键词 Dynamic capillary effect capillary pressure Two-phase flow Modeling method
下载PDF
Enantioseparation of Several PharmaceuticalRacemates with High PerformanceCapillary electrophoresis
19
作者 李方 靳慧 +2 位作者 戴荣继 顾峻岭 傅若农 《Journal of Beijing Institute of Technology》 EI CAS 1997年第3期239-243,共5页
With high performance capillary electrophoresis using -cyclodextrin or its deriveatives as the chiral selectors, five pairs of drug enantiomers were separated, The PH of the back- gmund electrolyte and the chiral sele... With high performance capillary electrophoresis using -cyclodextrin or its deriveatives as the chiral selectors, five pairs of drug enantiomers were separated, The PH of the back- gmund electrolyte and the chiral selector concentrations were optimized; and the effect of organic modifier on separation of chlorpheniramine enantiomers was also inver 展开更多
关键词 capillary electrophoresis ENANTIOSEPARATION chiral drugs
下载PDF
A covalent modified hydrophilic capillary for enhanced capillary electrophoresis of biopolymers 被引量:1
20
作者 Lian Guo Shan Xue Yu +2 位作者 Yin Mao Wei Xiao Hui Zheng Jian Bin Zheng 《Chinese Chemical Letters》 SCIE CAS CSCD 2009年第9期1123-1126,共4页
8-Gluconolactone was covalently coupled to aminopropyl derivatized capillary, which created hydrophilic brushes on the inner wall of the capillary. The coated capillary was shown to generate a stable electroosmotic fl... 8-Gluconolactone was covalently coupled to aminopropyl derivatized capillary, which created hydrophilic brushes on the inner wall of the capillary. The coated capillary was shown to generate a stable electroosmotic flow (EOF) in the investigated pH range of 2.0-9.0 and to suppress effectively the adsorption of proteins. And it enabled separation of some biopolymer mixtures including basic proteins, DNA and tryptic digested bovine serum albumin (BSA) within 15 rain with efficiencies up to 450,000 plates/m. The intra- and inter-day reproducibility of the coating referring to the retention times of proteins were satisfactory with mean relative standard deviations (R.S.D.) of 0.8 and 1.7%, respectively. 2009 Yin Mao Wei. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All fights reserved. 展开更多
关键词 capillary electrophoresis capillary coating 8-Gluconolactone Protein separation
下载PDF
上一页 1 2 41 下一页 到第
使用帮助 返回顶部