期刊文献+
共找到146篇文章
< 1 2 8 >
每页显示 20 50 100
A New Method for Decreasing Mass Limit of Detection and Increasing Number of Theoretical Plates in Capillary Electrophoresis with Amperometric Detection
1
作者 Xue Mei SUN Qian Feng WENG Wen Rui JIN 《Chinese Chemical Letters》 SCIE CAS CSCD 2003年第4期404-406,共3页
A new method was developed to decrease the mass limit of detection (LOD) and increase the number of theoretical plates (N) in capillary electrophoresis with amperometric detection. When the single microcylinder electr... A new method was developed to decrease the mass limit of detection (LOD) and increase the number of theoretical plates (N) in capillary electrophoresis with amperometric detection. When the single microcylinder electrode, the 10 um ID capillary with the etched detection end and the in-capillary alignment were used, the mass LOD for phenol was reduced 124 times and N was increased 36 times in comparison with the normal situation. 展开更多
关键词 capillary electrophoresis electrochemical detection MICROELECTRODE phenol.
下载PDF
Amperometric Detection of Histamine and Amino Acid Neurotransmitters in Capillary Electrophoresis with Copper Microelectrodes
2
作者 Hu, Shen Huang, Weihua +2 位作者 Pang, Daiwen Wang, Zongli Cheng, Jieke 《Wuhan University Journal of Natural Sciences》 EI CAS 1998年第3期87-90,共4页
Copper microelectrodes were used in microvoltammetry to detect histamine and several amino acid neurotransmitters. High sensitivity was obtained through the use of copper microelectrodes, and detection limits of 50 n... Copper microelectrodes were used in microvoltammetry to detect histamine and several amino acid neurotransmitters. High sensitivity was obtained through the use of copper microelectrodes, and detection limits of 50 nmol/L and 90 nmol/L were obtained for histamine and histidine, respectively. Furthermore, histamine and several amino acids neurotransmitters were firstly separated and detected by capillary electrophoresis with amperometric detection on copper microelectrodes. Mass limits of 490 amol and 440 amol were achieved for histamine and histidine, respectively, by using this mothod. 展开更多
关键词 capillary electrophoresis amperometric detection copper microelectrode
下载PDF
Simultaneous Detection of 13 Key Bacterial Respiratory Pathogens by Combination of Multiplex PCR and Capillary Electrophoresis 被引量:8
3
作者 JIANG Lu Xi REN Hong Yu +5 位作者 ZHOU Hai Jian ZHAO Si Hong HOU Bo Yan YAN Jian Ping QIN Tian CHEN Yu 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2017年第8期549-561,共13页
Objective Lower respiratory tract infections continue to pose a significant threat to human health. It is important to accurately and rapidly detect respiratory bacteria. To compensate for the limits of current respir... Objective Lower respiratory tract infections continue to pose a significant threat to human health. It is important to accurately and rapidly detect respiratory bacteria. To compensate for the limits of current respiratory bacteria detection methods, we developed a combination of multiplex polymerase chain reaction (PCR) and capillary electrophoresis (MPCE) assay to detect thirteen bacterial pathogens responsible for lower respiratory tract infections, including Streptococcus pneumoniae, Haemophilus influenzae, Moraxella catorrholis, Pseudomonas aeruginosa, Klebsiella pneumoniae, Escherichia coli, Staphylococcus aureus, Mycoplasma pneumoniae, Legionella spp., Bordetella pertussis, Mycobacterium tuberculosis complex, Corynebactefium diphthefiae, and Streptococcus pyogenes. Methods Three multiplex PCR reactions were built, and the products were analyzed by capillary electrophoresis using the high-throughput DNA analyzer. The specificity of the MPCE assay was examined and the detection limit was evaluated using DNA samples from each bacterial strain and the simulative samples of each strain. This assay was further evaluated using 152 clinical specimens and compared with real-time PCR reactions. For this assay, three nested-multiplex-PCRs were used to detect these clinical specimens. Results The detection limits of the MPCE assay for the 13 pathogens were very low and ranged from 10-7 to 10-2 ng/μL. Furthermore, analysis of the 252 clinical specimens yielded a specificity ranging from 96.5%-100.0%, and a sensitivity of 100.0% for the 13 pathogens. Conclusion This study revealed that the MPCE with high specificity and sensitivity. This assay survey of respiratory pathogens. assay is a rapid, reliable, and high-throughput method has great potential in the molecular epidemiological. 展开更多
关键词 Respiratory pathogens Lower respiratory tract infections Multiplex PCR capillary electrophoresis
下载PDF
p-Hydrazinobenzenesulfonic Acid Derivatives of Carbohydrates andTheir Capillary Zone Electrophoresis 被引量:6
4
作者 Wang, XY Chen, Y 《Chinese Chemical Letters》 SCIE CAS CSCD 2000年第12期1081-1084,共4页
关键词 p-hydrazinobenzenesulfonic acid CARBOHYDRATE DERIVATIZATION capillary zone electrophoresis
下载PDF
Recent advances in screening of enzymes inhibitors based on capillary electrophoresis 被引量:5
5
作者 Mengxia Cheng Zilin Chen 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2018年第4期226-233,共8页
Capillary electrophoresis with many advantages plays an important role in pharmaceutical analysis and drug screening. This review gives an overview on the recent advances in the developments and applications of capill... Capillary electrophoresis with many advantages plays an important role in pharmaceutical analysis and drug screening. This review gives an overview on the recent advances in the developments and applications of capillary electrophoresis in the field of enzyme inhibitor screening. The period covers 2013 to 2017. Both the pre-capillary enzyme assays and in-capillary enzyme assays which include electrophoretically mediated microanalysis(EMMA) and immobilized enzyme microreactor(IMER) are summarized in this article. 展开更多
关键词 capillary electrophoresis Enzyme inhibitor screening Pre-capillary enzyme assays Electrophoretically mediated microanalysis Immobilized enzyme microreactor
下载PDF
Capillary electrophoresis with electrochemiluminescence detection for the analysis of quinolone drugs and pharmacokinetics study 被引量:4
6
作者 Yan Ming Liu Jun Tao Cao Hui Wang 《Chinese Chemical Letters》 SCIE CAS CSCD 2008年第8期962-964,共3页
A novel method for the determination of two quinolone drugs norfloxacin (NOR) and levofloxacin (LVX) was described by capillary electrophoresis with electrochemiluminescence detection. The good relationship (r ≥... A novel method for the determination of two quinolone drugs norfloxacin (NOR) and levofloxacin (LVX) was described by capillary electrophoresis with electrochemiluminescence detection. The good relationship (r ≥ 0.9991) between peak area and concentration of analytes was established over two orders of magnitude. The limits of detection (LOD, S/N = 3) in standard solution are 4.8 × 10^-7 mol/L for NOR and 6.4 × 10^-7 mol/L for LVX, respectively. The limits of quantitation (LOQ, S/N = 10) in real human urine samples are 1.2 × 10^-6 mol/L for NOR and 1.4 × 10^-6 mol/L for LVX, respectively. The present method was successfully applied to the determination of NOR and LVX in human urine and the studv of oharmacokinetics of NOR. 展开更多
关键词 capillary electrophoresis Electrochemiluminescence detection Quinolone drugs Urine analysis PHARMACOKINETICS
下载PDF
Determination of Nicotine in Tobacco by Capillary Electrophoresis with Electrochemical Detection 被引量:4
7
作者 SUN Jin-ying XU Xiao-yu +1 位作者 YU Huan YOU Tian-yan 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2012年第3期415-418,共4页
A sensitive, simple and low-cost method based on capillary electrophoresis(CE) with electrochemical(EC) detection at a carbon fiber microdisk electrode(CFE) was developed for the determination of nicotine. Effec... A sensitive, simple and low-cost method based on capillary electrophoresis(CE) with electrochemical(EC) detection at a carbon fiber microdisk electrode(CFE) was developed for the determination of nicotine. Effects of de- tection potential, concentration and pH value of the phosphate buffer, and injection time as well as separation voltage were investigated. Under the optimized conditions: a detection potential of 1.20 V, 40 rnmol/L phosphate buffer(pH 2.0), a sample injection time of 10 s at 10 kV and a separation voltage of 16 kV, the linear range obtained was from 5.0×10^-7 mol/L to 1.0×10^-4 mol/L with a correlation coefficient of 0.9989 and the limit of detection(LOD, S/N=3) obtained was 5.0×10^-8 mol/L. The method was also used to determine the nicotine in cigarettes. Nicotine amount ranged from 0.211 mg/g to 0.583 mg/g in the pipe tobacco of seven brands of cigarette and the amount in one ciga- rette varied from 0.136 mg/cigarette to 0.428 mg/cigarette. 展开更多
关键词 capillary electrophoresis Electrochemical detection NICOTINE TOBACCO
下载PDF
Study on Rhizoma Chuanxiong based on capillary electrophoresis with amperometric detection 被引量:3
8
作者 Chu, Qing Cui Zhang, Dong Li +1 位作者 Zhang, Hai Tao Ye, Jian Nong 《Chinese Chemical Letters》 SCIE CAS CSCD 2010年第2期217-220,共4页
A high-performance capillary electrophoresis with amperometric detection(CE-AD) method has been developed for the analysis of seven bioactive ingredients,namely ferulic acid(FA),vanillin,vanillic acid,p-hydroxybenzoic... A high-performance capillary electrophoresis with amperometric detection(CE-AD) method has been developed for the analysis of seven bioactive ingredients,namely ferulic acid(FA),vanillin,vanillic acid,p-hydroxybenzoic acid,caffeic acid,gallic acid and protocatechuic acid,in Rhizoma Chuanxiong.The effects of several factors such as the acidity and concentration of running buffer,the separation voltage,the applied potential to working electrode and the injection time were investigated.Under the optimum condit... 展开更多
关键词 capillary electrophoresis Amperometric detection Rhizoma Chuanxiong Phenolic acids Electrochemical profiles
下载PDF
Optimized Separation of Pharmacologically Active Xanthones from Securidaca inappendiculata by Capillary Electrophoresis 被引量:3
9
作者 TaoBO XueDongYANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2002年第3期269-272,共4页
A capillary electrophoresis (CE) method has been firstly used for the separation of the therapeutically important xanthones from Securidaca inappendiculata. The separation of the nine xanthones was systematically opt... A capillary electrophoresis (CE) method has been firstly used for the separation of the therapeutically important xanthones from Securidaca inappendiculata. The separation of the nine xanthones was systematically optimized with respect to pH, concentration of running buffers, addition of sulfated b-CD, applied voltage and column temperature. Baseline separation was achieved for the nine xanthones in less than 15 minutes using a background electrolyte consisting of 200 mmol/L borate (pH 9.5) and 10 mmol/L sulfated b-CD. 展开更多
关键词 SEPARATION XANTHONES Securidaca inappendiculata capillary electrophoresis sulfated b-CD. Introduction
下载PDF
Studies on Human Immunoglobulin G from GBS Patient (Ⅲ)-The Determination of Molecular Weight of Human Immunoglobulin G by Capillary SDS Gel Electrophoresis 被引量:5
10
作者 Qin Hua RU Yi Ming WANG Guo An LUO(Department of Chemistry. School of Life Science and Engineering,Tsinghua University. Beijing, 100084) 《Chinese Chemical Letters》 SCIE CAS CSCD 1999年第1期55-58,共4页
Guillain-Barre syndrome (GBS) is considered to be an autoimmune disorder of peripheralnervous system. In this paper. capillary SDS gel electrophoresis was performed on neutral coatedfused-silica capillary to determine... Guillain-Barre syndrome (GBS) is considered to be an autoimmune disorder of peripheralnervous system. In this paper. capillary SDS gel electrophoresis was performed on neutral coatedfused-silica capillary to determine the molecular weight of purified IgG samples from GBS patient. 展开更多
关键词 Immunoglobulin G Guillain-Barre syndrome capillary SDS gel electrophoresis Molecular weight of protein
下载PDF
A novel method for Co(Ⅱ) and Cu(Ⅱ) analysis by capillary electrophoresis with chemiluminescence detection 被引量:3
11
作者 Xiao Ming Guo Xiang Dong Xu +2 位作者 Hui Jing Zhang Yong Gang Hu Jie Zhang 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第9期1095-1098,共4页
Based on the fact that some metal ions can catalyze the chemiluminescence(CL)reaction of luminol with K_3Fe(CN)_6,a novel capillary electrophoresis CL method was developed for the determination of Co(Ⅱ)and Cu(Ⅱ).The... Based on the fact that some metal ions can catalyze the chemiluminescence(CL)reaction of luminol with K_3Fe(CN)_6,a novel capillary electrophoresis CL method was developed for the determination of Co(Ⅱ)and Cu(Ⅱ).The separation was carried out with a 10 mmol/L sodium acetate solution containing 0.8 mmol/L luminol and 2.0 mmol/Lα-HIBA(adjusted to pH 4.8 by HAc solution).The post-capillary reagent was 2.0 mmol/L K_3Fe(CN)_6 which was adjusted to pH 13.0 by NaOH solution.Under the optimum conditions,the detection limits(S/N=3)for Co(Ⅱ)and Cu(Ⅱ)were 7.5×10^(-11)mol/L and 7.5×10^(-9)mol/L,with the linear range of 7.5×10^(-9)mol/L to 1.0×10^(-6)mol/L and 7.5×10^(-8)mol/L to 5.0×10^(-5)mol/L, respectively. 展开更多
关键词 capillary electrophoresis CHEMILUMINESCENCE Co(Ⅱ) Cu(Ⅱ)
下载PDF
Determination of Magnolol and Honokiol by Non-aqueous Capillary Electrophoresis 被引量:3
12
作者 TIAN Yi-ling CHEN Guan-hua 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2006年第3期335-338,共4页
Two active principles in traditional Chinese medicine Magnolia officinalis, magnolol and honokiol, were successfully separated by means of nonaqueous capillary electrophoresis. The effect of the composition of a nonaq... Two active principles in traditional Chinese medicine Magnolia officinalis, magnolol and honokiol, were successfully separated by means of nonaqueous capillary electrophoresis. The effect of the composition of a nonaqueous buffer on column efficiency and resolution, and the effect of acid additives on peak shapes were researched. The separation was conducted with a running buffer in a mixture of methanol/aeetonitrile/formamide ( volume ratio : 1 : 2 : 2 ), in which the concentrations of Tris, acetic acid, and water were 60 retool/L, 0. 04 mmol/L and 5% ( volume fration), respectively, and the pH^* (apperent pH) of the running buffer was 8.96. Magnolol and honokiol were separated on baseline within 20 min. The relative standard deviation of the analytes' concentrations in the sample is 1.32% for magnolol and 1.60% for honokiol, and the recoveries of the spiked sample are 98.4% for magnolol and 98. 0% for honokiol, respectively. 展开更多
关键词 Nonaqueous capillary electrophoresis MAGNOLOL HONOKIOL
下载PDF
Synthesis and Characterisation of Water-Soluble Carboxymethyl-Cyclodextrin Polymer as Capillary Electrophoresis Chiral Selector 被引量:3
13
作者 Xue Yan SHI Rui Fang FAN +2 位作者 Yue Qin ZHANG Jun Ling GU Ruo Nong FU( College of Chemical Engineering and Material Science Beijing Institute of Technology, Beijing 100081) 《Chinese Chemical Letters》 SCIE CAS CSCD 2000年第1期69-70,共2页
The water-soluble carboxymethyl-cyclodextrin polymer (CM-CD polymer) was synthesized and used as capillary electrophoresis chiral selector. Verrapamil and thiopentorusodium were well separated using CM-CD polymer as c... The water-soluble carboxymethyl-cyclodextrin polymer (CM-CD polymer) was synthesized and used as capillary electrophoresis chiral selector. Verrapamil and thiopentorusodium were well separated using CM-CD polymer as chiral selector. 展开更多
关键词 Carboxymethyl-cyclodextrin polymer capillary electrophoresis chiral selector.
下载PDF
Analysis of Phenolic Compounds in Coke Plant Wastewater by Capillary Zone Electrophoresis with Inhibited Chemiluminescence Detection 被引量:2
14
作者 Xiang Dong XU Yong Gang HU Ze Yu YANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第7期925-928,共4页
A capillary electrophoresis(CE) with on-line inhibited chemiluminescence (CL) detection was firstly used for the simultaneous analysis of benzenediol isomers and phenol. It is based on the quenching effect of benz... A capillary electrophoresis(CE) with on-line inhibited chemiluminescence (CL) detection was firstly used for the simultaneous analysis of benzenediol isomers and phenol. It is based on the quenching effect of benzenediol isomers and phenol on the chemiluminescence reaction of luminol with potassium ferricyanide in sodium hydroxide medium. Under the optimum conditions, the four phenols were baseline separated and detected in less than 10 rain. The detection limits (S/N=3) for hydroquinone, resorcinol, catechol and phenol were 2.9×10^-8 mol/L, 3.7×10^-7 mol/L, 8.4×10^-8 mol/L and 4.4×10^-6 mol/L, respectively. Finally, the presented method has been successfully applied to real sample. 展开更多
关键词 capillary electrophoresis CHEMILUMINESCENCE PHENOL benzenediol isomers wastewater.
下载PDF
Sensitive Method for Enantioseparation of Rivastigmine with Highly Sulfated Cyclodextrin as Chiral Selector by Capillary Electrophoresis 被引量:2
15
作者 王兆彦 许杏祥 +1 位作者 胡之德 康经武 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2006年第10期1384-1387,共4页
A sensitive method for enantioseparation of a basic drug rivastigmine and determination of its optical impurity by capillary electrophoresis with highly sulfated β-cyclodextrin (HS-β-CD) as the chiral selector is ... A sensitive method for enantioseparation of a basic drug rivastigmine and determination of its optical impurity by capillary electrophoresis with highly sulfated β-cyclodextrin (HS-β-CD) as the chiral selector is described. In general, enantioseparation of basic chiral compounds is carried out in acidic condition (pH 2.5) to prevent analytes from adsorption on the capillary wall. However, in the case of rivastigmine, the detection sensitivity was too limited to determine the optical impurity of S-rivastigmine lower than 1% when buffer pH was 2.5. It was found that the detection sensitivity was improved 1.6 times just by raising the buffer pH value from 2.5 to 5.8. The poor column efficiency due to the adsorption of the analytes on the capillary wall was resolved by using dynamical coating of the capillary wall with the linear polyacrylamide solution. The experimental parameters such as the concentration of HS-β-CD, buffer pH and buffer ionic strength were optimized, respectively. The method was validated in terms of repeatability, linearity, limit of detection (LOD) and limit of quantitation (LOQ). Using the present method, the optical purity of nonracemic rivastigmine with the enantiomeric excess (ee) value of 99.14% was determined. 展开更多
关键词 RIVASTIGMINE ENANTIOSEPARATION capillary electrophoresis highly sulfated β-cyclodextrin
原文传递
Analysis of Amino Acids in a Single Human Red Blood Cell by Capillary Zone Electrophoresis with Intracellular NDA- derivatization and Electrochemical Detection 被引量:2
16
作者 Qian DONG Xiao Lei WANG +1 位作者 Lan Lan ZHU Wen Rui JIN 《Chinese Chemical Letters》 SCIE CAS CSCD 2002年第7期655-657,共3页
A novel method for determination of amino acids in individual human red blood cells has been developed. In this method, the derivatization reagents (NDA and CN-) are introduced into living cells by electroporation. ... A novel method for determination of amino acids in individual human red blood cells has been developed. In this method, the derivatization reagents (NDA and CN-) are introduced into living cells by electroporation. After completion of derivatization, the amino acids in a single cell is determined by capillary zone electrophoresis with end-column amperometric detection. 展开更多
关键词 capillary electrophoresis electrochemical detection single cell analysis amino acid.
下载PDF
Determination of Cordycepin in Cordyceps kyushuensis by Capillary Electrophoresis and its Antitumour Activity 被引量:2
17
作者 Ying Jie SUN Jian Ya LING +1 位作者 Peng L Han Xing ZHANG Chang Kai ZHANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2003年第7期724-727,共4页
A simple, rapid and low-cost method of determination for cordycepin in Cordyceps kyushuensis by capillary zone electrophoresis (CZE) was developed. Based on the finding that there is a high concentration of cordycepin... A simple, rapid and low-cost method of determination for cordycepin in Cordyceps kyushuensis by capillary zone electrophoresis (CZE) was developed. Based on the finding that there is a high concentration of cordycepin in both natural and cultured Cordyceps kyushuensis, the in vitro antitumor activity of cordycepin and the water extracts of Cordyceps kyushuensis has been investigated. This is the first report about the antitumor effect of Cordyceps kyushuensis. 展开更多
关键词 CORDYCEPIN Cordyceps kyushuensis capillary zone electrophoresis cancer cell line antitumor activity.
下载PDF
A Capillary Electrophoresis Detection Scheme for Water-soluble Vitamins Based on Luminol-BrO^- Chemiluminescence System 被引量:2
18
作者 Wei DENG Wei Ping YANG +1 位作者 Zhu Jun ZHANG Hou Jiang ZHOU 《Chinese Chemical Letters》 SCIE CAS CSCD 2003年第2期185-187,共3页
A novel chemiluminescence detection scheme has been developed for detecting water-soluble vitamins following capillary electrophoresis (CE) separation. This detection was based on the inhibitory effect of vitamins on... A novel chemiluminescence detection scheme has been developed for detecting water-soluble vitamins following capillary electrophoresis (CE) separation. This detection was based on the inhibitory effect of vitamins on the CL reaction between luminol and BrO- in basic aqueous solution. Detection of vitamins was accomplished with a boratebased background electrolyte at pH 9.2. The luminol was used as a component of the separation carrier electrolyte. 展开更多
关键词 capillary electrophoresis CHEMILUMINESCENCE vitamins.
下载PDF
Analysis of arecoline in Semen Arecae decoction pieces by microchip capillary electrophoresis with contactless conductivity detection 被引量:2
19
作者 Zi-You Cai Yong-Chong Li +1 位作者 Li-Hua Li Zuan-Guang Chen 《Journal of Pharmaceutical Analysis》 CAS 2012年第5期356-360,共5页
A new method for the determination of arecoline in Semen Arecae decoction pieces by microchip capillary electrophoresis with contactless conductivity detection (MCE-CCD) was proposed. The effects of various electrop... A new method for the determination of arecoline in Semen Arecae decoction pieces by microchip capillary electrophoresis with contactless conductivity detection (MCE-CCD) was proposed. The effects of various electrophoretic operating parameters on the analysis of arecoline were studied. Under the optimal conditions, arecoline was rapidly separated and detected in 1 rain with good linearity over the concentration range of 20 1500 uM (r2=0.9991) and the detection limit of 5 uM (S/N=3). The method was used for the analysis of arecoline satisfactorily with a recovery of 96.8 -104%. 展开更多
关键词 Microchip capillary electrophoresis Contactless conductivity detection ARECOLINE Semen Arecae
下载PDF
Carbon Fiber-gold/mercury Dual-electrode Detection for Capillary Electrophoresis 被引量:1
20
作者 Qian Feng WENG Wen Rui JIN 《Chinese Chemical Letters》 SCIE CAS CSCD 2002年第10期985-987,共3页
A carbon fiber-gold/mercury dual-electrode for capillary electrophoresis is constructed. Cysteine, glutathione, ascorbic acid and uric acid can be detected simultaneously and selectively at the dual-electrode, respect... A carbon fiber-gold/mercury dual-electrode for capillary electrophoresis is constructed. Cysteine, glutathione, ascorbic acid and uric acid can be detected simultaneously and selectively at the dual-electrode, respectively. The capillary electrophoresis / dual-electrode detection system has been used to determine these compounds in human blood samples. 展开更多
关键词 ascorbic acid capillary electrophoresis CYSTEINE electrochemical detection electrode GLUTATHIONE uric acid
下载PDF
上一页 1 2 8 下一页 到第
使用帮助 返回顶部