A method for the determination of dichlofluanid residue by Capillary Collumns Gas Chromatography was established in this study.Samples were extracted with acetone and subjected to through liquid-liquid extraction with...A method for the determination of dichlofluanid residue by Capillary Collumns Gas Chromatography was established in this study.Samples were extracted with acetone and subjected to through liquid-liquid extraction with N-hexane,and then they were cleanup with column that filled with florisil,subsequently separated by Capillary Column Gas Chromatography,and the electron capture detector (ECD) was used for detection.The detection limit of this method was 0.005 mg/kg (S/N=3),and this method was rapid,sensitive and accurate,and was applied in the determination of dichlofluanid residue in soybean.展开更多
[Objectives]This study was conducted to purify mutton samples by gel permeation chromatography(GPC).[Methods]Fourteen organophosphorus pesticide residues in samples were qualitatively and quantitatively analyzed by ga...[Objectives]This study was conducted to purify mutton samples by gel permeation chromatography(GPC).[Methods]Fourteen organophosphorus pesticide residues in samples were qualitatively and quantitatively analyzed by gas chromatography-mass spectrometry(GC-MS)in selective ion scanning mode(SIM).[Results]The organophosphorus pesticide standard solutions showed good linearity in the mass concentration range of 0.1-10.0μg/ml with correlation coefficients(r)not lower than 0.999,and the detection limits(S=3 N)ranged from 0.01 to 0.05 mg/kg.The average recovery values were in the range of 80.2%-99.7%,with relative standard deviations(RSDs,n=3)in the range of 1.8%-6.3%,at the addition levels of 0.5,1.0 and 2.0 mg/kg.[Conclusions]The method is simple,sensitive and accurate,and can be used for the determination of organophosphorus pesticide residues in mutton.展开更多
A method for the assay of R ( ) and S (+) mexiletine in rat liver microsomal incubates was developed. The method involved extraction of mexiletine from the microsomal incubates, and formation of mexiletine diast...A method for the assay of R ( ) and S (+) mexiletine in rat liver microsomal incubates was developed. The method involved extraction of mexiletine from the microsomal incubates, and formation of mexiletine diastereomeric derivatives with a chiral reagent S ( ) N trifluoroacetyl prolyl chloride. Separation and quantitation of the diastereomeric mexiletine derivatives were carried out by a capillary gas chromatographic system with flame ionization detection. The assay was linear from 5 to 500 μg/ml for each enantiomer. The average recoveries of analytical method were 93 31±5 59% and 93 10±5 11% for R ( ) and S (+) mexiletine, respectively. The limits of detection and quantitation for the method were 1 0 μg/ml and 5 0 μg/ml for the R ( ) and S (+) mexiletine isomers, respectively. The reproducibility in the assay was better than 16.5% (RSD). The method has been applied to the metabolism study of R ( ) and S (+) mexiletine in rat liver microsomal incubates.展开更多
The present study describes guanidinium-based ionic liquids(GBILs) as stationary phases for capillary gas chromatography (CGC) and to the best of our knowledge,no related reports are available up to now.In this st...The present study describes guanidinium-based ionic liquids(GBILs) as stationary phases for capillary gas chromatography (CGC) and to the best of our knowledge,no related reports are available up to now.In this study,a hexaalkylguanidinium ionic liquid(DOTMG-NTf;) was synthesized and coated statically onto capillary columns.Selectivity of the stationary phase was evaluated by separating Grob test mixture,test mixture,alcohols mixture,and fatty acid methyl esters mixture,and thermal stability was investigated as well.The present study demonstrates that GBILs as CGC stationary phases exhibit satisfactory selectivity and thermal stability and have a great potential as new candidates for CGC stationary phases.展开更多
One chloride-terminated ionic liquid(CTIL) and two hydroxyl-terminated ionic liquids(HTILs) were synthesized and used as stationary phases for capillary gas chromatography(CGC).Molecular interactions of these st...One chloride-terminated ionic liquid(CTIL) and two hydroxyl-terminated ionic liquids(HTILs) were synthesized and used as stationary phases for capillary gas chromatography(CGC).Molecular interactions of these stationary phases were evaluated by Abraham solvation parameter model,indicating that the CTIL exhibits remarkably strong H-bond basicity and the HTILs possess both H-bond basicity and acidity.The molecular interactions were further confirmed by separation of a complex mixture consisting of ketones,aldehydes,esters,alcohols and aromatic compounds.It was found that the obtained solvation parameters correlate well with the chromatographic performances of the analytes in terms of elution order and resolution.The well correlated relationship between the solvation parameters and the selectivity of the CTIL and HTILs stationary phases is quite helpful in predicting and understanding the retention behaviors of different types of analytes on these stationary phases.展开更多
A new ionic liquids grafted polysiloxane used as stationary phase for capillary gas chromatography (CGC) is described. The stationary phase of 1-vinyl-3-hexylimidazolium hexafluorophosphate anchored to polysiloxane ...A new ionic liquids grafted polysiloxane used as stationary phase for capillary gas chromatography (CGC) is described. The stationary phase of 1-vinyl-3-hexylimidazolium hexafluorophosphate anchored to polysiloxane (PMHS-[VHIm][PF6]) was synthe- sized, characterized and coated onto capillary columns by static coating. The results show that the present stationary phase exhibits a very good chromatographic resolution and selectivity for Grob test mixture and alcohols with baseline resolution and symmetry peaks. The present work suggests that novel stationary phase has a great potential for further development and application. 2009 Mei Ling Qi. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.展开更多
A guanidinium ionic liquid,N,N,N',N'-tetrahexyl-N",N"-dimethylguanidinium bis(trifluoromethane)sulfonylimide(THDMGNTf2), was synthesized and used as stationary phase for capillary gas chromatography.In compari...A guanidinium ionic liquid,N,N,N',N'-tetrahexyl-N",N"-dimethylguanidinium bis(trifluoromethane)sulfonylimide(THDMGNTf2), was synthesized and used as stationary phase for capillary gas chromatography.In comparison with imidazolium ionic liquid stationary phase,the present new stationary phase exhibits quite different selectivity and behaves more like a low polar stationary phase.The guanidinium ionic liquid of THDMG-NTf2 exhibited better separation of Grab test mixture than imidazolium ionic liquid of 1-octyl-3-butylimidazolium bis(trifluoromethane)sulfonylimide(OBIM-NTf2).Solvation parameter model was also used to evaluate the selectivity of THDMG-NTf2.Additionally,essential oil of Magnolia biondii Pamp was analyzed to further evaluate the selectivity of THDMG-NTf2 for a sample of complicated components.Satisfactory separation of the essential oil was achieved on a THDMG-NTf2 column(10 m) while using a commercial column(30 m) as reference.The present study shows that the guanidinium ionic liquid possesses novel chromatographic selectivity and has great potential for wide applications.展开更多
The aim of this study was to develop a simple and derivatization free method for the Quantification of S-Epichlorohydrin in R-Epichlorohydrin by using a gas chromatography coupled with flame ionization detector (FID)....The aim of this study was to develop a simple and derivatization free method for the Quantification of S-Epichlorohydrin in R-Epichlorohydrin by using a gas chromatography coupled with flame ionization detector (FID). Enantiopure epichlorohydrin was a valuable epoxide key starting material for preparing optically active Rivaroxaban. The enantiomeric separations of S-Epichlorohydrin and R-Epichlorohydrin were achieved on Gamaa-Dex-225 (30 meters × 0.25 mm I.D, 0.25 μm) column with a total run time of 30 min. Nitrogen was used as a carrier gas with constant pressure 25.0 psi. The critical experimental parameters such as, column selection, flow rate, injection volume and diluent were studied and optimized. Excellent correlation coeffient between peak responses and concentrations was >0.9998. The recoveries of S-Epichlorohydrin spiked in R-Epichlorohydrin were in the range from 98.2% to 102.8%. Limit of quantitation for S-Epichlorohydrin was sufficiently lower than limits specified by ICH. The method has validated as per International Conference on Harmonization (ICH) guidelines. A precise, accurate, linear and robust Gas Chromatography method was developed for the quantification of S-Epichlorohydrin in R-Epichlorohydrin for Rivaroxaban.展开更多
Using four β-cyclodextrin derivatives, 2,6-di-O-benzyl-3-O-heptanonyl-β-CD, 2,6-di- O-benzyl-3-O-octanonyl-β-CD, 2,3-di-O-benzyl-6-O-heptanonyl-β-CD, and 2,3-di-O-benzyl -6-O- octanonyl-β-CD, as chiral stationary...Using four β-cyclodextrin derivatives, 2,6-di-O-benzyl-3-O-heptanonyl-β-CD, 2,6-di- O-benzyl-3-O-octanonyl-β-CD, 2,3-di-O-benzyl-6-O-heptanonyl-β-CD, and 2,3-di-O-benzyl -6-O- octanonyl-β-CD, as chiral stationary phases of capillary gas chromatography (CGC), the enantiomers of Sharpless epoxides were well separated. The enantiomer excess values (e.e.%) of some chiral Sharpless epoxides were also determined successfully using these CDs.展开更多
A method is developed for the simultaneous determination of ephedrine,pseudoephedrine, norephedrine, norpseudoephedrine and methylephedrine in urine on a capillary column using nitrogen-phosphorus detector.Diphenylami...A method is developed for the simultaneous determination of ephedrine,pseudoephedrine, norephedrine, norpseudoephedrine and methylephedrine in urine on a capillary column using nitrogen-phosphorus detector.Diphenylamine is used as the internal standard.Calibration graphs are linear down to 1.30ug/ml urine.展开更多
A novel β-cyclodextrin derivative, 2, 6-di-O-butyl-3-O-acetyl-β-cyclodex- trin, was prepared and used as chiral stationary phase for capillary gas chromato- graphic resolution of enantiomers, lhe glass capillary col...A novel β-cyclodextrin derivative, 2, 6-di-O-butyl-3-O-acetyl-β-cyclodex- trin, was prepared and used as chiral stationary phase for capillary gas chromato- graphic resolution of enantiomers, lhe glass capillary columns with the derivative having low melting point and high thermal stability could produce more than 3000 plates per column meter and have proven to be good chlral columns to separate the enantiomers of some amino acids, derivatives of epoxy ethane and alkyl halide, etc.展开更多
In present work,the volatile constituents of Curcuma longa L.,A.lancea (Thunb.) DC.,Foeniculum vulgare Mill,and Cinnamomun cassia Presl.have been analyzed by flash distillation/capillary gas chro-matography/mass spect...In present work,the volatile constituents of Curcuma longa L.,A.lancea (Thunb.) DC.,Foeniculum vulgare Mill,and Cinnamomun cassia Presl.have been analyzed by flash distillation/capillary gas chro-matography/mass spectrometry.The results are consistent with those obtained by conventional steam distillation extraction method.The optimum condition of flash distillation has been studied.The experimental results showed that this new technique proved to be a simple,rapid and efficient tool for microanalysis of volatile constituents of Chinese medicinal herbs.展开更多
The combination of pyrolysis high resolution gas chromatography and pat- tern recognition techniques is a powerful tool for the classification of traditional Chinese drug.A study has been completed on 55 Beimu samples...The combination of pyrolysis high resolution gas chromatography and pat- tern recognition techniques is a powerful tool for the classification of traditional Chinese drug.A study has been completed on 55 Beimu samples of five different geographic origins: Eastern China.Central China.South-western China,North-western China and North-eastern China.Principal component analysis and SIMCA are applied to effectively classifying the samples according to the origin of the plants.The chemical information contained in the high resolution gas chromatographic data is sufficient to characterize the geographic origin of sam- pies.展开更多
A new method for simultaneous determination of four phthalate esters ( PAEs) in commercial fat-containing foods was developed by the combination of a packed nanofibers column based on solid-phase extraction with gas...A new method for simultaneous determination of four phthalate esters ( PAEs) in commercial fat-containing foods was developed by the combination of a packed nanofibers column based on solid-phase extraction with gas chromatography-flame ionization detector ( GC-FID ). Conditions for obtaining optimum extraction efficiency such as extraction solvents, morphologies of adsorbent, ion strength and pH were investigated and optimized in detail. Under the optimized conditions, the limits of detection (LODs) found for dibutyl phthalate (DBP) , butyl benzyl phthalate (BBP), diethyl hexyl phthalate (DEHP) and di-n-octyl phthalate (DNOP) were 50, 25, 50 and 25 ng/g, respectively. Good linearity of four PAEs was achieved in the range of 50 to 4 000 ng/g. The proposed method was applied for analyzing different kinds of fat-containing samples. PAEs in commercial fat-containing samples can be highly extracted by a packed solid-phase extraction column of 5 mg polystyrene ( PS) nanofibers. The satisfactory average recoveries were obtained in the range of 96. 7% to 102. 3% , and the relative standard deviations (RSDs) below 5% were achieved. The proposed method reduces the organic solvent consumption, the complex and tedious procedures for sample pretreatment, and achieves high sensitivity and reproducibility for the investigated PAEs.展开更多
A new capillary gas chromatography stationary phase, monokis (2,6 di O benzyl 3 O propyl (3’)) hexakis(2,6 di O benzyl 3 O methyl) β CD bonded polysiloxane, was synthesized. It ex...A new capillary gas chromatography stationary phase, monokis (2,6 di O benzyl 3 O propyl (3’)) hexakis(2,6 di O benzyl 3 O methyl) β CD bonded polysiloxane, was synthesized. It exhibited separation abilities to disubstituted benzene isomers and some chiral solutes. It was also found that the polarity of CD derivatives can be lowered both by chemically bonding it to polysiloxane and by diluting it in polysiloxane. The separation abilities of the polysiloxane anchored CDs (SP CD) are higher than that of the unbonded CDs (S CD) and the diluted S CD at lower column temperature. Hydrosilylation reaction is one of the best methods to lower the operating temperature of CDs.展开更多
Polysiloxane with pendant [60] fulleropyrrolidines was synthesized and used as the stationary phase for capillary gas chromatography for the first time. A preliminary investigation of its property shows that it has an...Polysiloxane with pendant [60] fulleropyrrolidines was synthesized and used as the stationary phase for capillary gas chromatography for the first time. A preliminary investigation of its property shows that it has an excellent thermostability and a wide range of allowable operating temperature from 80 degrees C to 360 degrees C.展开更多
The composition and sequence distribution of monomeric units in polyester polyether multiblock copolymer were studied by pyrolysis? gas chromatography (PGC) and pyrolysis gas chromatography/mass spectrometry (PGC/M...The composition and sequence distribution of monomeric units in polyester polyether multiblock copolymer were studied by pyrolysis? gas chromatography (PGC) and pyrolysis gas chromatography/mass spectrometry (PGC/MS). PGC was applied to study the F t curve of the multiblock copolymer and PGC/MS was used to separate and identify the pyrolyzates. DTA experiment was used to study the decomposition temperature. The results show that the beginning point of elastomer’s decomposition was about 300?℃ and the decomposition temperature of most of the sample was 550?℃. Many pyrolyzates were produced because of the breaking of weak bonds in the sample. The possible microstructure was verified and the pyrolysis pathway of the copolymer was investigated.展开更多
Applications of pyrolysis-gas chromatography and pyrolysis capillary gas chromatography in explosive and propellant analysis are reviewed, including the identification of explosives and propel- lants, the investigatio...Applications of pyrolysis-gas chromatography and pyrolysis capillary gas chromatography in explosive and propellant analysis are reviewed, including the identification of explosives and propel- lants, the investigation of the thermal decomposition of nitrocellulose (NC), cyclotetramethylene tetranitramine (HMX)and cyclotrimethylene trinitramine (RDX), and the study of the wear- reducing mechanism of polyurethane additive in propellant gain.展开更多
The cross-linking of crown ether-SE-54 in fused-silica capillary columns were initiated by dicumyl peroxide(DCUP),azo-bis-isobutyronitrile (AIBN)and ozone(O_3).Parameters of evaluation such as polarity,selectivity, ph...The cross-linking of crown ether-SE-54 in fused-silica capillary columns were initiated by dicumyl peroxide(DCUP),azo-bis-isobutyronitrile (AIBN)and ozone(O_3).Parameters of evaluation such as polarity,selectivity, phase transition temperature and thermal stability were studied and compared with those of poly(crown ether)stationary phase.展开更多
文摘A method for the determination of dichlofluanid residue by Capillary Collumns Gas Chromatography was established in this study.Samples were extracted with acetone and subjected to through liquid-liquid extraction with N-hexane,and then they were cleanup with column that filled with florisil,subsequently separated by Capillary Column Gas Chromatography,and the electron capture detector (ECD) was used for detection.The detection limit of this method was 0.005 mg/kg (S/N=3),and this method was rapid,sensitive and accurate,and was applied in the determination of dichlofluanid residue in soybean.
基金Supported by The Fourth Batch of High-end Talent Project in Hebei Province.
文摘[Objectives]This study was conducted to purify mutton samples by gel permeation chromatography(GPC).[Methods]Fourteen organophosphorus pesticide residues in samples were qualitatively and quantitatively analyzed by gas chromatography-mass spectrometry(GC-MS)in selective ion scanning mode(SIM).[Results]The organophosphorus pesticide standard solutions showed good linearity in the mass concentration range of 0.1-10.0μg/ml with correlation coefficients(r)not lower than 0.999,and the detection limits(S=3 N)ranged from 0.01 to 0.05 mg/kg.The average recovery values were in the range of 80.2%-99.7%,with relative standard deviations(RSDs,n=3)in the range of 1.8%-6.3%,at the addition levels of 0.5,1.0 and 2.0 mg/kg.[Conclusions]The method is simple,sensitive and accurate,and can be used for the determination of organophosphorus pesticide residues in mutton.
文摘A method for the assay of R ( ) and S (+) mexiletine in rat liver microsomal incubates was developed. The method involved extraction of mexiletine from the microsomal incubates, and formation of mexiletine diastereomeric derivatives with a chiral reagent S ( ) N trifluoroacetyl prolyl chloride. Separation and quantitation of the diastereomeric mexiletine derivatives were carried out by a capillary gas chromatographic system with flame ionization detection. The assay was linear from 5 to 500 μg/ml for each enantiomer. The average recoveries of analytical method were 93 31±5 59% and 93 10±5 11% for R ( ) and S (+) mexiletine, respectively. The limits of detection and quantitation for the method were 1 0 μg/ml and 5 0 μg/ml for the R ( ) and S (+) mexiletine isomers, respectively. The reproducibility in the assay was better than 16.5% (RSD). The method has been applied to the metabolism study of R ( ) and S (+) mexiletine in rat liver microsomal incubates.
基金the National Nature Science Foundation of China(No.20675007)
文摘The present study describes guanidinium-based ionic liquids(GBILs) as stationary phases for capillary gas chromatography (CGC) and to the best of our knowledge,no related reports are available up to now.In this study,a hexaalkylguanidinium ionic liquid(DOTMG-NTf;) was synthesized and coated statically onto capillary columns.Selectivity of the stationary phase was evaluated by separating Grob test mixture,test mixture,alcohols mixture,and fatty acid methyl esters mixture,and thermal stability was investigated as well.The present study demonstrates that GBILs as CGC stationary phases exhibit satisfactory selectivity and thermal stability and have a great potential as new candidates for CGC stationary phases.
基金the National Nature Science Foundation of China(No.20675007).
文摘One chloride-terminated ionic liquid(CTIL) and two hydroxyl-terminated ionic liquids(HTILs) were synthesized and used as stationary phases for capillary gas chromatography(CGC).Molecular interactions of these stationary phases were evaluated by Abraham solvation parameter model,indicating that the CTIL exhibits remarkably strong H-bond basicity and the HTILs possess both H-bond basicity and acidity.The molecular interactions were further confirmed by separation of a complex mixture consisting of ketones,aldehydes,esters,alcohols and aromatic compounds.It was found that the obtained solvation parameters correlate well with the chromatographic performances of the analytes in terms of elution order and resolution.The well correlated relationship between the solvation parameters and the selectivity of the CTIL and HTILs stationary phases is quite helpful in predicting and understanding the retention behaviors of different types of analytes on these stationary phases.
基金the National Natural Science Foundation of China for the funding(No.20675007)
文摘A new ionic liquids grafted polysiloxane used as stationary phase for capillary gas chromatography (CGC) is described. The stationary phase of 1-vinyl-3-hexylimidazolium hexafluorophosphate anchored to polysiloxane (PMHS-[VHIm][PF6]) was synthe- sized, characterized and coated onto capillary columns by static coating. The results show that the present stationary phase exhibits a very good chromatographic resolution and selectivity for Grob test mixture and alcohols with baseline resolution and symmetry peaks. The present work suggests that novel stationary phase has a great potential for further development and application. 2009 Mei Ling Qi. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.
基金the National Nature Science Foundation of China(No.20675007)
文摘A guanidinium ionic liquid,N,N,N',N'-tetrahexyl-N",N"-dimethylguanidinium bis(trifluoromethane)sulfonylimide(THDMGNTf2), was synthesized and used as stationary phase for capillary gas chromatography.In comparison with imidazolium ionic liquid stationary phase,the present new stationary phase exhibits quite different selectivity and behaves more like a low polar stationary phase.The guanidinium ionic liquid of THDMG-NTf2 exhibited better separation of Grab test mixture than imidazolium ionic liquid of 1-octyl-3-butylimidazolium bis(trifluoromethane)sulfonylimide(OBIM-NTf2).Solvation parameter model was also used to evaluate the selectivity of THDMG-NTf2.Additionally,essential oil of Magnolia biondii Pamp was analyzed to further evaluate the selectivity of THDMG-NTf2 for a sample of complicated components.Satisfactory separation of the essential oil was achieved on a THDMG-NTf2 column(10 m) while using a commercial column(30 m) as reference.The present study shows that the guanidinium ionic liquid possesses novel chromatographic selectivity and has great potential for wide applications.
基金Grant in AidforScientificResearchfromTheJapanSocietyforthePromotionofScience(JSPS) ,Grant in AidforYoungScientistsfromTheMinistryofEducation ,Culture ,Sports ,ScienceandTechnology (MEXT)
文摘The aim of this study was to develop a simple and derivatization free method for the Quantification of S-Epichlorohydrin in R-Epichlorohydrin by using a gas chromatography coupled with flame ionization detector (FID). Enantiopure epichlorohydrin was a valuable epoxide key starting material for preparing optically active Rivaroxaban. The enantiomeric separations of S-Epichlorohydrin and R-Epichlorohydrin were achieved on Gamaa-Dex-225 (30 meters × 0.25 mm I.D, 0.25 μm) column with a total run time of 30 min. Nitrogen was used as a carrier gas with constant pressure 25.0 psi. The critical experimental parameters such as, column selection, flow rate, injection volume and diluent were studied and optimized. Excellent correlation coeffient between peak responses and concentrations was >0.9998. The recoveries of S-Epichlorohydrin spiked in R-Epichlorohydrin were in the range from 98.2% to 102.8%. Limit of quantitation for S-Epichlorohydrin was sufficiently lower than limits specified by ICH. The method has validated as per International Conference on Harmonization (ICH) guidelines. A precise, accurate, linear and robust Gas Chromatography method was developed for the quantification of S-Epichlorohydrin in R-Epichlorohydrin for Rivaroxaban.
基金This work was kindly supported by the National Natural Science Foundation of China(No.30471153,30170621and 21023478).
文摘Using four β-cyclodextrin derivatives, 2,6-di-O-benzyl-3-O-heptanonyl-β-CD, 2,6-di- O-benzyl-3-O-octanonyl-β-CD, 2,3-di-O-benzyl-6-O-heptanonyl-β-CD, and 2,3-di-O-benzyl -6-O- octanonyl-β-CD, as chiral stationary phases of capillary gas chromatography (CGC), the enantiomers of Sharpless epoxides were well separated. The enantiomer excess values (e.e.%) of some chiral Sharpless epoxides were also determined successfully using these CDs.
文摘A method is developed for the simultaneous determination of ephedrine,pseudoephedrine, norephedrine, norpseudoephedrine and methylephedrine in urine on a capillary column using nitrogen-phosphorus detector.Diphenylamine is used as the internal standard.Calibration graphs are linear down to 1.30ug/ml urine.
文摘A novel β-cyclodextrin derivative, 2, 6-di-O-butyl-3-O-acetyl-β-cyclodex- trin, was prepared and used as chiral stationary phase for capillary gas chromato- graphic resolution of enantiomers, lhe glass capillary columns with the derivative having low melting point and high thermal stability could produce more than 3000 plates per column meter and have proven to be good chlral columns to separate the enantiomers of some amino acids, derivatives of epoxy ethane and alkyl halide, etc.
文摘In present work,the volatile constituents of Curcuma longa L.,A.lancea (Thunb.) DC.,Foeniculum vulgare Mill,and Cinnamomun cassia Presl.have been analyzed by flash distillation/capillary gas chro-matography/mass spectrometry.The results are consistent with those obtained by conventional steam distillation extraction method.The optimum condition of flash distillation has been studied.The experimental results showed that this new technique proved to be a simple,rapid and efficient tool for microanalysis of volatile constituents of Chinese medicinal herbs.
文摘The combination of pyrolysis high resolution gas chromatography and pat- tern recognition techniques is a powerful tool for the classification of traditional Chinese drug.A study has been completed on 55 Beimu samples of five different geographic origins: Eastern China.Central China.South-western China,North-western China and North-eastern China.Principal component analysis and SIMCA are applied to effectively classifying the samples according to the origin of the plants.The chemical information contained in the high resolution gas chromatographic data is sufficient to characterize the geographic origin of sam- pies.
基金The National Basic Research Program of China(973Program)(No.2012CB933302)the National Instrumental Research Program(No.2014YQ06077303)+1 种基金the National Natural Science Foundation of China(No.81172720,21307086)Suzhou Science and Technology Department Foundation(No.ZXG201441)
文摘A new method for simultaneous determination of four phthalate esters ( PAEs) in commercial fat-containing foods was developed by the combination of a packed nanofibers column based on solid-phase extraction with gas chromatography-flame ionization detector ( GC-FID ). Conditions for obtaining optimum extraction efficiency such as extraction solvents, morphologies of adsorbent, ion strength and pH were investigated and optimized in detail. Under the optimized conditions, the limits of detection (LODs) found for dibutyl phthalate (DBP) , butyl benzyl phthalate (BBP), diethyl hexyl phthalate (DEHP) and di-n-octyl phthalate (DNOP) were 50, 25, 50 and 25 ng/g, respectively. Good linearity of four PAEs was achieved in the range of 50 to 4 000 ng/g. The proposed method was applied for analyzing different kinds of fat-containing samples. PAEs in commercial fat-containing samples can be highly extracted by a packed solid-phase extraction column of 5 mg polystyrene ( PS) nanofibers. The satisfactory average recoveries were obtained in the range of 96. 7% to 102. 3% , and the relative standard deviations (RSDs) below 5% were achieved. The proposed method reduces the organic solvent consumption, the complex and tedious procedures for sample pretreatment, and achieves high sensitivity and reproducibility for the investigated PAEs.
文摘A new capillary gas chromatography stationary phase, monokis (2,6 di O benzyl 3 O propyl (3’)) hexakis(2,6 di O benzyl 3 O methyl) β CD bonded polysiloxane, was synthesized. It exhibited separation abilities to disubstituted benzene isomers and some chiral solutes. It was also found that the polarity of CD derivatives can be lowered both by chemically bonding it to polysiloxane and by diluting it in polysiloxane. The separation abilities of the polysiloxane anchored CDs (SP CD) are higher than that of the unbonded CDs (S CD) and the diluted S CD at lower column temperature. Hydrosilylation reaction is one of the best methods to lower the operating temperature of CDs.
文摘Polysiloxane with pendant [60] fulleropyrrolidines was synthesized and used as the stationary phase for capillary gas chromatography for the first time. A preliminary investigation of its property shows that it has an excellent thermostability and a wide range of allowable operating temperature from 80 degrees C to 360 degrees C.
文摘The composition and sequence distribution of monomeric units in polyester polyether multiblock copolymer were studied by pyrolysis? gas chromatography (PGC) and pyrolysis gas chromatography/mass spectrometry (PGC/MS). PGC was applied to study the F t curve of the multiblock copolymer and PGC/MS was used to separate and identify the pyrolyzates. DTA experiment was used to study the decomposition temperature. The results show that the beginning point of elastomer’s decomposition was about 300?℃ and the decomposition temperature of most of the sample was 550?℃. Many pyrolyzates were produced because of the breaking of weak bonds in the sample. The possible microstructure was verified and the pyrolysis pathway of the copolymer was investigated.
文摘Applications of pyrolysis-gas chromatography and pyrolysis capillary gas chromatography in explosive and propellant analysis are reviewed, including the identification of explosives and propel- lants, the investigation of the thermal decomposition of nitrocellulose (NC), cyclotetramethylene tetranitramine (HMX)and cyclotrimethylene trinitramine (RDX), and the study of the wear- reducing mechanism of polyurethane additive in propellant gain.
文摘The cross-linking of crown ether-SE-54 in fused-silica capillary columns were initiated by dicumyl peroxide(DCUP),azo-bis-isobutyronitrile (AIBN)and ozone(O_3).Parameters of evaluation such as polarity,selectivity, phase transition temperature and thermal stability were studied and compared with those of poly(crown ether)stationary phase.