Using two b-cyclodextrin derivatives (CDs) with long chain of acyl groups as chiral stationary phases (CSPs) of capillary gas chromatography (CGC), the enantiomers of racemic allethrone and propargyllone were well res...Using two b-cyclodextrin derivatives (CDs) with long chain of acyl groups as chiral stationary phases (CSPs) of capillary gas chromatography (CGC), the enantiomers of racemic allethrone and propargyllone were well resolved after derived with acetyl chloride. The enantiomer excess values (e.e.%) of 1S-allethrone and 1S-propargyllone were also determined successfully using these CDs.展开更多
This research paper describes simple analytical method for determination of Camylofin dihydrochloride and Nimesulide in tablet formulation by Gas chromatography method. Benzoic acid was used as internal standard. Vali...This research paper describes simple analytical method for determination of Camylofin dihydrochloride and Nimesulide in tablet formulation by Gas chromatography method. Benzoic acid was used as internal standard. Validation was carried out in compliance with the International Conference on Harmonization guidelines. The method utilized GC (Agilent Technologies 6890 N Network GC system with FID detector), and RTX-5 capillary column (5% diphenyl-95% dimethyl polysiloxane), 30 m × 0.53 mm, 1.5 μm as stationary phase. Helium was used as the carrier gas at a flow rate of 1.5 mL?min–1. The proposed method was validated for linearity, LOD, LOQ, accuracy, precision, ruggedness and solution stability. It can be conveniently adopted for routine quality control analysis.展开更多
文摘Using two b-cyclodextrin derivatives (CDs) with long chain of acyl groups as chiral stationary phases (CSPs) of capillary gas chromatography (CGC), the enantiomers of racemic allethrone and propargyllone were well resolved after derived with acetyl chloride. The enantiomer excess values (e.e.%) of 1S-allethrone and 1S-propargyllone were also determined successfully using these CDs.
文摘This research paper describes simple analytical method for determination of Camylofin dihydrochloride and Nimesulide in tablet formulation by Gas chromatography method. Benzoic acid was used as internal standard. Validation was carried out in compliance with the International Conference on Harmonization guidelines. The method utilized GC (Agilent Technologies 6890 N Network GC system with FID detector), and RTX-5 capillary column (5% diphenyl-95% dimethyl polysiloxane), 30 m × 0.53 mm, 1.5 μm as stationary phase. Helium was used as the carrier gas at a flow rate of 1.5 mL?min–1. The proposed method was validated for linearity, LOD, LOQ, accuracy, precision, ruggedness and solution stability. It can be conveniently adopted for routine quality control analysis.