期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Analysis of arecoline in Semen Arecae decoction pieces by microchip capillary electrophoresis with contactless conductivity detection 被引量:2
1
作者 Zi-You Cai Yong-Chong Li +1 位作者 Li-Hua Li Zuan-Guang Chen 《Journal of Pharmaceutical Analysis》 CAS 2012年第5期356-360,共5页
A new method for the determination of arecoline in Semen Arecae decoction pieces by microchip capillary electrophoresis with contactless conductivity detection (MCE-CCD) was proposed. The effects of various electrop... A new method for the determination of arecoline in Semen Arecae decoction pieces by microchip capillary electrophoresis with contactless conductivity detection (MCE-CCD) was proposed. The effects of various electrophoretic operating parameters on the analysis of arecoline were studied. Under the optimal conditions, arecoline was rapidly separated and detected in 1 rain with good linearity over the concentration range of 20 1500 uM (r2=0.9991) and the detection limit of 5 uM (S/N=3). The method was used for the analysis of arecoline satisfactorily with a recovery of 96.8 -104%. 展开更多
关键词 microchip capillary electrophoresis Contactless conductivity detection ARECOLINE Semen Arecae
下载PDF
Polydimethylsiloxane Microchip Capillary Electrophoresis for Determination of Cholesterol
2
作者 Nipapan Ruecha Weena Siangproh Orawon Chailapakul 《Journal of Electronic Science and Technology of China》 2010年第1期82-86,共5页
Microchip capillary electrophoresis (MCE) has significant impact on diagnostic testing. One of the most importance in clinical analysis test is the determination of cholesterol level in blood, because its increase i... Microchip capillary electrophoresis (MCE) has significant impact on diagnostic testing. One of the most importance in clinical analysis test is the determination of cholesterol level in blood, because its increase is associated with coronary heart disease which is a major cause of death world over. Polydimethylsiloxane (PDMS) was material used to make a MCE for determination of cholesterol. Hydrogen peroxide was generated from the oxidation of cholesterol with cholesterol oxidase (ChOx) and was detected electrochemically at a downstream gold (Au) wire electrode by amperometry. Various parameters, such as the detection potential, concentration of running buffer, pH of running buffer, separation voltage, injection time, and concentration of ChOx, were studied. The migration time of cholesterol is less than 100s and the calibration curve is linear from 50 mg.dL-1 to 250 mg-dL-1 with the coefficient of determination (R2) of 0.9955. Therefore, this proposed assay is very rapid and sensitive for the detection of cholesterol. 展开更多
关键词 CHOLESTEROL cholesterol oxidase microchip capillary electrophoresis polydimethylsiloxane.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部