Limestone powder is still applied as SO2 sorbent in emerging oxygen-fuel circulating fluidized bed boiler, but its carbonation in O2/CO2 flue gas is an unclear problem. For a better understanding of carbonation behavi...Limestone powder is still applied as SO2 sorbent in emerging oxygen-fuel circulating fluidized bed boiler, but its carbonation in O2/CO2 flue gas is an unclear problem. For a better understanding of carbonation behaviors, the tube furnace heating system was built for simulating circulating fluidized bed boiler flue gas by regulating the supply of O, CO2, N2, SO2 and H2O, and Carbonation reaction was tested. Thermal gravimetric analysis and scanning electron microscopy were used. It was found that carbonation is closely related to temperature, CO2 concentration, impurities, water vapor, and cycle times;high temperature can promote carbonation process;high concentration of CO2 can inhibit the chemical reaction stage speed of carbonation process, but it has little effect on the final conversion rate;water vapor can increase the final conversion rate of carbonation;the cycle times will reduce the activity of carbonation. The presence of carbonation turns the traditional boiler flue gas indirect desulfurization model into indirect desulfurization mechanism which does not have a negative impact on SO2 removal efficiency.展开更多
The mixed venous-to-arterial carbon dioxide(CO_2)tension difference[P(v-a) CO_2]is the difference between carbon dioxide tension(PCO_2) in mixed venous blood(sampled from a pulmonary artery catheter) and the PCO_2 in ...The mixed venous-to-arterial carbon dioxide(CO_2)tension difference[P(v-a) CO_2]is the difference between carbon dioxide tension(PCO_2) in mixed venous blood(sampled from a pulmonary artery catheter) and the PCO_2 in arterial blood.P(v-a) CO_2 depends on the cardiac output and the global CO_2 production,and on the complex relationship between PCO_2 and CO_2 content.Experimental and clinical studies support the evidence that P(v-a) CO_2 cannot serve as an indicator of tissue hypoxia,and should be regarded as an indicator of the adequacy of venous blood to wash out the total CO_2generated by the peripheral tissues.P(v-a) CO_2 can be replaced by the central venous-to-arterial CO_2 difference(△PCO_2),which is calculated from simultaneous sampling of central venous blood from a central vein catheter and arterial blood and,therefore,more easy to obtain at the bedside.Determining the △PCO_2 during the resuscitation of septic shock patients might be useful when deciding when to continue resuscitation despite a central venous oxygen saturation(SCVO_2) > 70%associated with elevated blood lactate levels.Because high blood lactate levels is not a discriminatory factor in determining the source of that stress,an increased △PCO_2(> 6 mmHg)could be used to identify patients who still remain inadequately resuscitated.Monitoring the △PCO_2 from the beginning of the reanimation of septic shock patients might be a valuable means to evaluate the adequacy of cardiac output in tissue perfusion and,thus,guiding the therapy.In this respect,it can aid to titrate inotropes to adjust oxygen delivery to CO_2 production,or to choose between hemoglobin correction or fluid/inotrope infusion in patients with a too low ScvO_2 related to metabolic demand.The combination of P(v-a) CO_2 or △PCO_2 with oxygen-derived parameters through the calculation of the P(v-a) CO_2 or △PCO_2/arteriovenous oxygen content difference ratio can detect the presence of global anaerobic metabolism.展开更多
文摘Limestone powder is still applied as SO2 sorbent in emerging oxygen-fuel circulating fluidized bed boiler, but its carbonation in O2/CO2 flue gas is an unclear problem. For a better understanding of carbonation behaviors, the tube furnace heating system was built for simulating circulating fluidized bed boiler flue gas by regulating the supply of O, CO2, N2, SO2 and H2O, and Carbonation reaction was tested. Thermal gravimetric analysis and scanning electron microscopy were used. It was found that carbonation is closely related to temperature, CO2 concentration, impurities, water vapor, and cycle times;high temperature can promote carbonation process;high concentration of CO2 can inhibit the chemical reaction stage speed of carbonation process, but it has little effect on the final conversion rate;water vapor can increase the final conversion rate of carbonation;the cycle times will reduce the activity of carbonation. The presence of carbonation turns the traditional boiler flue gas indirect desulfurization model into indirect desulfurization mechanism which does not have a negative impact on SO2 removal efficiency.
文摘The mixed venous-to-arterial carbon dioxide(CO_2)tension difference[P(v-a) CO_2]is the difference between carbon dioxide tension(PCO_2) in mixed venous blood(sampled from a pulmonary artery catheter) and the PCO_2 in arterial blood.P(v-a) CO_2 depends on the cardiac output and the global CO_2 production,and on the complex relationship between PCO_2 and CO_2 content.Experimental and clinical studies support the evidence that P(v-a) CO_2 cannot serve as an indicator of tissue hypoxia,and should be regarded as an indicator of the adequacy of venous blood to wash out the total CO_2generated by the peripheral tissues.P(v-a) CO_2 can be replaced by the central venous-to-arterial CO_2 difference(△PCO_2),which is calculated from simultaneous sampling of central venous blood from a central vein catheter and arterial blood and,therefore,more easy to obtain at the bedside.Determining the △PCO_2 during the resuscitation of septic shock patients might be useful when deciding when to continue resuscitation despite a central venous oxygen saturation(SCVO_2) > 70%associated with elevated blood lactate levels.Because high blood lactate levels is not a discriminatory factor in determining the source of that stress,an increased △PCO_2(> 6 mmHg)could be used to identify patients who still remain inadequately resuscitated.Monitoring the △PCO_2 from the beginning of the reanimation of septic shock patients might be a valuable means to evaluate the adequacy of cardiac output in tissue perfusion and,thus,guiding the therapy.In this respect,it can aid to titrate inotropes to adjust oxygen delivery to CO_2 production,or to choose between hemoglobin correction or fluid/inotrope infusion in patients with a too low ScvO_2 related to metabolic demand.The combination of P(v-a) CO_2 or △PCO_2 with oxygen-derived parameters through the calculation of the P(v-a) CO_2 or △PCO_2/arteriovenous oxygen content difference ratio can detect the presence of global anaerobic metabolism.
文摘[目的]准确了解2010年以来扎龙自然保护区生态变化,为提高湿地生态系统服务价值评估能力提供数据支持和理论参考。[方法]基于遥感、气象、地面协同观测数据,利用CASA(Carnegie-Ames-Stanford Approach)模型、GSMSR(Geostatistical Model of Soil Respiration)模型和回归分析等统计方法,分析气候变化对2010—2020年扎龙自然保护区土地覆盖、植被生态质量、净生态系统生产力(NEP)等的影响。[结果](1)扎龙自然保护区的主要土地覆盖类型为有水草甸,占保护区面积的37.24%,主要分布在核心区,但面积总体呈下降趋势;(2)植被覆盖度呈波动增长趋势,年最高植被覆盖度平均为74.62%;(3)植被生态质量指数呈增加趋势,2019,2020年处于“好”等级;NEP平均为253.59 g/(m^(2)·a)(以C计),呈现东高西低的空间分布特征;(4)生长季平均固碳量为5.69×10^(5) t/a,释氧量1.52×10^(6) t/a,均存在上升趋势;(5)气温对生态监测指标的影响大于降水量。[结论]扎龙自然保护区是嫩江流域生态最为脆弱的区域,植被生产力受气候影响大,需要加强生态保护和修复。