期刊文献+
共找到11篇文章
< 1 >
每页显示 20 50 100
Cat's Eye:An Old Comedy
1
作者 王莹 《海外英语》 2012年第12X期229-230,共2页
Northrop Frye' s four narrative forms:romance,tragedy,irony,and comedy can help explain the problematic structure of Margaret Atwood' s novel Cat' s Eye,in which the narrative,as well as certain other lite... Northrop Frye' s four narrative forms:romance,tragedy,irony,and comedy can help explain the problematic structure of Margaret Atwood' s novel Cat' s Eye,in which the narrative,as well as certain other literary features,indicates that it is essentially a come dy - a story of how a hero forms a desirable new society in the face of strong opposition.But this comedy is also ironic. 展开更多
关键词 ATWOOD cat s eye FRYE COMEDY
下载PDF
Infrared Absorption Spectra of Serpentine Cat's Eye from Sichuan Province of China
2
作者 卢保奇 夏义本 亓利剑 《Journal of Shanghai University(English Edition)》 CAS 2005年第4期365-368,共4页
Infrared (IR) absorption spectra and X-ray powder diffraction (XRD) patterrns of sexpenfine cat's eye from Sichuan Province have been investigated, and infrared absorption bands of the serpentine have been assign... Infrared (IR) absorption spectra and X-ray powder diffraction (XRD) patterrns of sexpenfine cat's eye from Sichuan Province have been investigated, and infrared absorption bands of the serpentine have been assigned in this paper. The results indicate that the bands near 3 600 - 3 700 cm^-1 belong to the stretching absorption band VOH, the bands in 948 - 1 100 cm^-1 axe assigned to the stretching vibraling band Usvo, and the bands at 600 570 and 440 cm^-1 respectively belong to the bending vibration band VOH, δMg-O and δSi-O. The serpentine cat' s eye includes two types: chrysotile and antigorite. Chrysotile has a sharp and intensive band at 3 688 cm^-1 and a weak band at 3 643 cm^-1 , while antigorite has only one intensive band in the region. At vibration band VSi-O, chrysotile and antigorite have a similar feature at 1 071 cm^-1, but the band at 980 cm^-1 in anfigorite has been split into two bands in chrysotile - a strong one at 1 027 cm^-1 and a weak one at 949 cm^-1. In addition, antigorite has a characteristic bending vibrating band δMg-O at 570 cm^-1. Based on the analysis of the feature of crystal structure, their IR differences axe well explained. 展开更多
关键词 serpentine cats eye infrared spectrum absorption band assigned.
下载PDF
New and Unusual Cat's Eyes and Asteriated Gems
3
作者 Martin P.Steinbach Lore Kiefert Jeanette Fiedler 《宝石和宝石学杂志(中英文)》 CAS 2022年第1期1-11,共11页
The article describes 6 types of gemstones which show phenomena such as chatoyancy and asterism.The gemstones have not been described before,either because they come from new sources,or because the phenomenon has not ... The article describes 6 types of gemstones which show phenomena such as chatoyancy and asterism.The gemstones have not been described before,either because they come from new sources,or because the phenomenon has not been seen before in the type of gemstone described.Gems from the new sources are star garnet from the Karelia Province in Russia,and star garnet from the Jiangsu Province in China.Grandidierite usually does not show a cat’s eye effect,but the two described samples display a weak cat’s eye.An unusual white quartz from Brazil with a sharp cat’s eye is described,as well as a star sapphire with two differently coloured stars on each side of the cabochon,as well as a trapiche-type quartz.The stones were tested with gemmological,microscopic,and advanced techniques and the results are presented. 展开更多
关键词 cats eye star asterism chatoyancy QUARTZ grandidierite sAPPHIRE GARNET
下载PDF
Measuring Method of Radius of Curvature Based on Dual-Frequency Laser Interferometer
4
作者 Wenlong Zhang Liang Miao Yu Liu 《Optics and Photonics Journal》 2016年第8期209-214,共6页
In order to achieve high-accuracy measurement of radius of curvature of optical sphere, ultra-high accuracy radius of curvature testing device is developed by dual-frequency laser interferometer and Fizeau interferome... In order to achieve high-accuracy measurement of radius of curvature of optical sphere, ultra-high accuracy radius of curvature testing device is developed by dual-frequency laser interferometer and Fizeau interferometer based on cat’s eye and confocal method. Through analyzing the error source models of radius of curvature testing, optical configuration of the testing device has been optimized. Precise environment control and real-time monitoring system is also established to reduce the errors caused by environment. Through the above processes, the radius of curvature measurement relative accuracy is better than 2 ppm. One optical sphere, R88.5 mm, test aperture 59 mm, has been tested. Testing result is 88499.465 ± 0.176 μm, meeting the design requirement. The method has high accuracy and practical advantages. 展开更多
关键词 Radius of Curvature cats eye and Confocal Method Dual-Frequency Laser Interferometer
下载PDF
Adjustable-free and movable Nd:YVO_(4) thin disk laser based on the telecentric cat's eye cavity 被引量:5
5
作者 Wei Wang Yongxi Gao +3 位作者 Di Sun Xiao Du Jie Guo Xiaoyan Liang 《Chinese Optics Letters》 SCIE EI CAS CSCD 2021年第11期54-59,共6页
In this paper, we propose and demonstrate an adjustable-free and movable Nd:YVO_(4)thin disk laser based on the telecentric cat’s eye cavity. We design a V-shaped laser cavity containing two reflectors with Nd:YVO_(4... In this paper, we propose and demonstrate an adjustable-free and movable Nd:YVO_(4)thin disk laser based on the telecentric cat’s eye cavity. We design a V-shaped laser cavity containing two reflectors with Nd:YVO_(4)thin disks as the gain medium.The experimental results from the traditional plane-plane cavity, plane-telecentric cat’s eye cavity, and double telecentric cat’s eye cavity are compared. They show that plane-telecentric cat’s eye cavity laser can keep operating at the adjustablefree range of -6° to +6°, which is up to 60 times better than that of traditional plane-plane cavity. In the double telecentric cat’s eye case, the adjustable-free range is improved to-13° to +13°. Additionally, in the case of the double telecentric cat’s eye cavity, the output telecentric cat’s eye can achieve free movement within the horizontal range of ±20 mm. 展开更多
关键词 thin disk laser telecentric cats eye adjustable-free laser
原文传递
CAT’S EYE
6
《男生女生(金版)》 2002年第5期60-63,共4页
关键词 cats eye
原文传递
猫眼动镜横移误差容限及次镜倾斜分析 被引量:2
7
作者 杨庆华 周仁魁 赵葆常 《光子学报》 EI CAS CSCD 北大核心 2009年第5期1171-1175,共5页
介绍了猫眼动镜干涉光谱仪的基本原理和三种猫眼镜,分析了猫眼动镜的横向偏移对干涉图的影响,推导了横移所产生的最大附加光程差公式,从相位误差角度给出了猫眼动镜的横移误差容限公式并得到了在典型参量下的定量数据.分析了猫眼镜次镜... 介绍了猫眼动镜干涉光谱仪的基本原理和三种猫眼镜,分析了猫眼动镜的横向偏移对干涉图的影响,推导了横移所产生的最大附加光程差公式,从相位误差角度给出了猫眼动镜的横移误差容限公式并得到了在典型参量下的定量数据.分析了猫眼镜次镜倾斜对光程差的影响,导出了次镜倾斜所产生的最大附加光程差公式,并给出了在典型参量下最大附加光程差与次镜倾角之间的关系图. 展开更多
关键词 干涉仪 猫眼镜 横移容限 次镜倾斜
下载PDF
猫眼逆反射器的设计与优化 被引量:13
8
作者 林永兵 张国雄 李真 《光学学报》 EI CAS CSCD 北大核心 2002年第10期1245-1250,共6页
按双半球结构设计了猫眼逆反射器 ,并指出当折射率n =2时 ,猫眼可以设计成一个完整的球体。详细研究了猫眼逆反射器的各种因素对光路光程的影响 ,指出加工时必须要控制两半球的对心偏差 (包括胶合厚度偏差 )。对猫眼返回光束的发散角进... 按双半球结构设计了猫眼逆反射器 ,并指出当折射率n =2时 ,猫眼可以设计成一个完整的球体。详细研究了猫眼逆反射器的各种因素对光路光程的影响 ,指出加工时必须要控制两半球的对心偏差 (包括胶合厚度偏差 )。对猫眼返回光束的发散角进行了研究 ,详尽讨论了返回光线的发散角与球半径、材料折射率以及入射高度的关系。以猫眼返回光束的发散角最小为优化目标进行了优化设计 。 展开更多
关键词 设计 猫眼逆反射器 激光跟踪干涉仪 优化 误差分析 干涉系统
原文传递
干涉成象光谱仪动镜运动误差分析(Ⅰ)——平面动镜倾斜容限分析 被引量:3
9
作者 相里斌 赵葆常 +3 位作者 薛鸣球 袁艳 杨建峰 高瞻 《光电子.激光》 EI CAS CSCD 1997年第3期195-198,共4页
本文根据一种干涉成象光谱仪方案,分析其平面动镜在移动时发生倾斜对干涉图的影响,导出对倾斜角度的限制条件。本文得到结论对采用平面动镜的干涉成象光谱仪具有普遍意义。
关键词 干涉成象 光谱仪 动镜 误差
原文传递
CER腔He-Ne激光器 被引量:4
10
作者 欧家鸣 李岩 +2 位作者 张书练 汪浩 王瑞丽 《激光与光电子学进展》 CSCD 2000年第7期27-30,共4页
提出采用猫眼逆向反射器 (CER)作为 He- Ne激光器的运动腔镜 ,取代平凹腔的平面反射镜 ,以降低其对导轨直线性要求 ,提高该系统作为频率分裂位移传感器的量程。用矩阵方程讨论了各种 CER的特性 ,给出相关理论分析和实验结果。
关键词 猫眼逆向反射器 激光腔动镜 HE-NE激光器
原文传递
玛格丽特·阿特伍德小说《猫眼》中欺凌创伤的分析研究 被引量:1
11
作者 王玮 《唐山文学》 2019年第6期141-142,共2页
一、玛格丽特·阿特伍德与《猫眼》玛格丽特·阿特伍德作为加拿大家喻户晓的作家,她写作体裁广泛,在小说、诗歌以及文学批评上均有建树。其作品曾屡获殊荣,其中包括获英国布克奖和加拿大总督文学奖,而她本人也有着极高的呼声竞... 一、玛格丽特·阿特伍德与《猫眼》玛格丽特·阿特伍德作为加拿大家喻户晓的作家,她写作体裁广泛,在小说、诗歌以及文学批评上均有建树。其作品曾屡获殊荣,其中包括获英国布克奖和加拿大总督文学奖,而她本人也有着极高的呼声竞争诺贝尔文学奖。阿特伍德非常关注她所处时代的社会状况和女性的命运。她的很多作品都给读者呈现了女性在社会中所面临的种种危机以及所遭受的痛苦与折磨。《猫眼》是阿特伍德创作的第七部小说,被冠以'迄今为止最有艺术成就的小说'的美誉。 展开更多
关键词 Margaret ATWOOD cats eye school BULLYING TRAUMA
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部