The Neighbor Cell Deposited Energy Ratio (NCDER) is a new method that is proposed to reconstruct incidence position in a single layer for a 3-dimensional imaging electromagnetic calorimeter (ECAL). This method was...The Neighbor Cell Deposited Energy Ratio (NCDER) is a new method that is proposed to reconstruct incidence position in a single layer for a 3-dimensional imaging electromagnetic calorimeter (ECAL). This method was applied to reconstruct the ECAL test beam data for the Alpha Magnetic Spectrometer-02 (AMS-02). The results show that this method can achieve an angular resolution of 7.36±0.08°/√E+0.28±0.02° in the determination of the photon's direction, which is much more precise than that obtained with the commonly-adopted Center of Gravity (COG) method (8.4±0.1°/E+0.8±0.3°). Furthermore, since it uses only the properties of electromagnetic showers, this new method could also be used for other type of fine grain sampling calorimeters.展开更多
基金Supported by China National Science Foundation(10805050)
文摘The Neighbor Cell Deposited Energy Ratio (NCDER) is a new method that is proposed to reconstruct incidence position in a single layer for a 3-dimensional imaging electromagnetic calorimeter (ECAL). This method was applied to reconstruct the ECAL test beam data for the Alpha Magnetic Spectrometer-02 (AMS-02). The results show that this method can achieve an angular resolution of 7.36±0.08°/√E+0.28±0.02° in the determination of the photon's direction, which is much more precise than that obtained with the commonly-adopted Center of Gravity (COG) method (8.4±0.1°/E+0.8±0.3°). Furthermore, since it uses only the properties of electromagnetic showers, this new method could also be used for other type of fine grain sampling calorimeters.