The central air conditioning system in an intelligent building (IB) was analyzed and modeled in order to perform the optimization scheduling strategy of the central air conditioning system. A set of models proposed ...The central air conditioning system in an intelligent building (IB) was analyzed and modeled in order to perform the optimization scheduling strategy of the central air conditioning system. A set of models proposed and a type of periodically autoregressive model (PAR) based on the improved genetic algorithms (IGA) were used to perform the optimum energy saving scheduling. The example of the Liangmahe Plaza was taken to show the effectiveness of the methods.展开更多
An optimum energy saving scheduling strategy of the central air conditioning system in an intelligent building (IB) was proposed. Based on the system analysis a set of models of the central air conditioning system w...An optimum energy saving scheduling strategy of the central air conditioning system in an intelligent building (IB) was proposed. Based on the system analysis a set of models of the central air conditioning system was established. The periodically autoregressive models (PARM) based on genetic algorithms (GA) were used to predict the next day’s cold load. The improved genetic algorithms (IGA) with stochastic real number coding were used to finish the optimum energy saving scheduling of the system. The simulation results for the building of the Liangmahe Plaza show that the proposed strategy can save energy up to about 24 5%.展开更多
An energy-saving control strategy based on predictive control for central air-conditioning systems is proposed in this paper. The cold load model is developed to describe the dynamic characteristics of temperature con...An energy-saving control strategy based on predictive control for central air-conditioning systems is proposed in this paper. The cold load model is developed to describe the dynamic characteristics of temperature control systems, and then parameters in the cold load model and in the central air-conditioning system model are estimated. Generalized predictive control (GPC) is used to establish an optimization model to minimize the consumption of energy and the control error of temperature. The simulated annealing (SA) algorithm, combined with quadratic programming, is adopted to solve the optimal problem. Contrasted with the simulation of traditional PID control, the results prove the effectiveness of this proposed strategy.展开更多
A structure of central air conditioning system in building and its running pattern are proposed in order to perform optimum energy saving strategy. The design of room temperature controller is taken as an example to d...A structure of central air conditioning system in building and its running pattern are proposed in order to perform optimum energy saving strategy. The design of room temperature controller is taken as an example to discuss the design of fuzzy controller using common microprogrammed control unit (MCU) in detail. Based on fuzzy theory the query control tables fixed in read only memory (ROM) of MCU are established to realize the energy saving in the room temperature controller and the reasoning procedure is analyzed. The diagram of hardware design and the flow chart of software of room temperature controller are presented. The results show that the proposed method is practical and effective to achieve the energy saving goal.展开更多
The stable operation of the central air conditioning water system always is a major difficulty for the control profession. Paper focus on the water system with multi variable, strong coupling, nonlinear, large time de...The stable operation of the central air conditioning water system always is a major difficulty for the control profession. Paper focus on the water system with multi variable, strong coupling, nonlinear, large time delay characteristics, presented use feed forward coupling compensation method, to eliminate the coupling effect between temperature and pressure. In this paper, the Elman neural network controller is designed for the first time, and the simulation results show that the response time of Elman neural network controller is shorter, the system is more stable and the overshoot is small.展开更多
With the gradually widely usage of the air conditioning(AC) loads in developing countries, the urban power grid load has swiftly increased over the past decade.Especially in China, the AC load has accounted for over30...With the gradually widely usage of the air conditioning(AC) loads in developing countries, the urban power grid load has swiftly increased over the past decade.Especially in China, the AC load has accounted for over30% of the maximum load in many cities during summer.This paper proposes a scheme of constructing a virtual peaking unit(VPU) by public buildings’ cool storage central AC(CSCAC) systems and non-CSCAC(NCSCAC)systems for the day-ahead power network dispatching(DAPND). Considering the accumulation effect of different meteorological parameters, a short term load forecasting method of public building’s central AC(CAC) baseline load is firstly discussed. Then, a second-order equivalent thermal parameters model is established for the public building’s CAC load. Moreover, the novel load reduction control strategies for the public building’s CSCAC system and the public building’s NCSCAC system are respectively presented. Furthermore, based on the multiple-rank control strategy, the model of the DAPND with the participation of a VPU is set up. The VPU is composed of large-scale regulated public building’s CAC loads. To demonstrate the effectiveness of the proposed strategy, results of a sample study on a region in Nanjing which involves 22 public buildings’ CAC loads are described in this paper. Simulated results show that, by adopting the proposed DAPND scheme, the power network peak load in the region obviously decreases with a small enough deviation between the regulated load value and the dispatching instruction of the VPU. The total electricity-saving amount accounts for7.78% of total electricity consumption of the VPU before regulation.展开更多
This study assessed six commercially available in-duct air cleaning devices which are designed to be mounted in the central ventilation system of offices or commercial buildings.The selected devices use different air ...This study assessed six commercially available in-duct air cleaning devices which are designed to be mounted in the central ventilation system of offices or commercial buildings.The selected devices use different air cleaning technologies:mechanical filtration,electrostatic precipitation,gas filtration,ionization/cold plasma,photocatalytic oxidation(PCO)and catalysis under UV light.They were tested against particles,a mixture of volatile organic compounds containing acetone,acetaldehyde,toluene,heptane and formaldehyde,and two bio-contaminants:Aspergillus brasiliensis(fungus)and Staphylococcus epidermidis(bacteria).Two different test rigs were used.The single pass efficiency of each device was determined for three airflow rates,corresponding to face velocities ranging from 0.9 to 2.7 m/s,and two sets of temperature and humidity that are representative of indoor air conditions in wintertime and summertime.The concentration of the chal-lenge volatile organic compounds was also varied in the 30 to 100μg/m^(3)range as a way to characterize their influence on efficiency at realistic concentration levels for non-industrial buildings.Measurements of ozone and formaldehyde concentration downstream of the air cleaners were carried out to determine the emission rate of by-products into the air stream.Finally,the energy issue was addressed by measuring the electric power drawn and pressure loss of the devices.The results showed that two devices,namely a radiant catalytic ionizer and a plasma ionizer,had a very low single pass efficiency against all the challenge pollutants.The association of the plasma ionizer and the electrostatic precipitator did not produce a synergetic effect between the two technologies either,contrary to what their manufacturer claims.Finally,three of the six devices tested were effective in terms of pollutant removal,but only two had an acceptable energy effectiveness in view of their use in low or zero energy buildings.Their energy effectiveness ranged from a few thousand m^(3)/kWh for VOCs at the highest airflow rate(3600 m^(3)/h),to more than 60000 m^(3)/kWh for particles and bio-contaminants at 1200 or 1600 m^(3)/h.These results are at least one order of magnitude higher than the majority of stand-alone air cleaners.Moreover,they suggest that optimal IAQ and energy conditions can be achieved if variable air volume control methods are used to maintain indoor temperature and humidity.展开更多
[Objective] The aim was to study the characteristics of urban air pollution on the basis of correspondence analysis.[Method] By using the correlated data from China Statistical Yearbook in 2010,a correspondence analys...[Objective] The aim was to study the characteristics of urban air pollution on the basis of correspondence analysis.[Method] By using the correlated data from China Statistical Yearbook in 2010,a correspondence analysis on the air pollution indicators(like respirable particles,SO2 and NO2) of six provincial capitals in central-south China was carried out by means of SPSS software,and the characteristics of air pollution in the cities of China during different industrialization stages were summarized further.[Result] In the cities during early industrialization(like Nanning City and Guiyang City) and mineral resource-based cities(like Taiyuan City),the air was mainly polluted by SO2;for the cities in the middle industrialization(such as Changsha City,Wuhan City,Zhengzhou City and Chengdu City),the air was polluted by respirable particles chiefly;in the cities in late industrialization(like Guangzhou City and Shenzhen City) or completing industrialization(like Shanghai City),the air was mainly polluted by NO2;for the cities in pre-industrial stage(like Haikou City and Lhasa City),the characteristic of air pollution wasn’t obvious.[Conclusion] The study could provide references for the control of urban air pollution in China in the further.展开更多
In this research, high voltage static electricity and ultraviolet technologies were integrated to an air purifying device which can be used to trap and kill airborne bacteria and viruses in central air-conditioning sy...In this research, high voltage static electricity and ultraviolet technologies were integrated to an air purifying device which can be used to trap and kill airborne bacteria and viruses in central air-conditioning systems. An experimental platform was built to mimic the central air system, in which the efficacy of the newly built device was examined. In addition to the standard physical and chemical tests, bacteriophages were used to simulate airborne viruses in the experimental system. The bacteriophage suspension was aerosolized into the air with ultrasonic wave atomization.The result showed that more than 86% removal efficiency of micro-particles (<10 micron in diameter) were removed after the device was in operation in a building and more than 95% of bacteriophages in the experimental system. It is concluded that the integrated air purifier is suitable for controlling air quality and preventing virus transmission through the central air system.展开更多
文摘The central air conditioning system in an intelligent building (IB) was analyzed and modeled in order to perform the optimization scheduling strategy of the central air conditioning system. A set of models proposed and a type of periodically autoregressive model (PAR) based on the improved genetic algorithms (IGA) were used to perform the optimum energy saving scheduling. The example of the Liangmahe Plaza was taken to show the effectiveness of the methods.
文摘An optimum energy saving scheduling strategy of the central air conditioning system in an intelligent building (IB) was proposed. Based on the system analysis a set of models of the central air conditioning system was established. The periodically autoregressive models (PARM) based on genetic algorithms (GA) were used to predict the next day’s cold load. The improved genetic algorithms (IGA) with stochastic real number coding were used to finish the optimum energy saving scheduling of the system. The simulation results for the building of the Liangmahe Plaza show that the proposed strategy can save energy up to about 24 5%.
文摘An energy-saving control strategy based on predictive control for central air-conditioning systems is proposed in this paper. The cold load model is developed to describe the dynamic characteristics of temperature control systems, and then parameters in the cold load model and in the central air-conditioning system model are estimated. Generalized predictive control (GPC) is used to establish an optimization model to minimize the consumption of energy and the control error of temperature. The simulated annealing (SA) algorithm, combined with quadratic programming, is adopted to solve the optimal problem. Contrasted with the simulation of traditional PID control, the results prove the effectiveness of this proposed strategy.
文摘A structure of central air conditioning system in building and its running pattern are proposed in order to perform optimum energy saving strategy. The design of room temperature controller is taken as an example to discuss the design of fuzzy controller using common microprogrammed control unit (MCU) in detail. Based on fuzzy theory the query control tables fixed in read only memory (ROM) of MCU are established to realize the energy saving in the room temperature controller and the reasoning procedure is analyzed. The diagram of hardware design and the flow chart of software of room temperature controller are presented. The results show that the proposed method is practical and effective to achieve the energy saving goal.
文摘The stable operation of the central air conditioning water system always is a major difficulty for the control profession. Paper focus on the water system with multi variable, strong coupling, nonlinear, large time delay characteristics, presented use feed forward coupling compensation method, to eliminate the coupling effect between temperature and pressure. In this paper, the Elman neural network controller is designed for the first time, and the simulation results show that the response time of Elman neural network controller is shorter, the system is more stable and the overshoot is small.
基金supported by National Key Technology Support Program (No. 2013BAA01B00)National Natural Science Foundation of China (No. 51361130152, No. 51577028)
文摘With the gradually widely usage of the air conditioning(AC) loads in developing countries, the urban power grid load has swiftly increased over the past decade.Especially in China, the AC load has accounted for over30% of the maximum load in many cities during summer.This paper proposes a scheme of constructing a virtual peaking unit(VPU) by public buildings’ cool storage central AC(CSCAC) systems and non-CSCAC(NCSCAC)systems for the day-ahead power network dispatching(DAPND). Considering the accumulation effect of different meteorological parameters, a short term load forecasting method of public building’s central AC(CAC) baseline load is firstly discussed. Then, a second-order equivalent thermal parameters model is established for the public building’s CAC load. Moreover, the novel load reduction control strategies for the public building’s CSCAC system and the public building’s NCSCAC system are respectively presented. Furthermore, based on the multiple-rank control strategy, the model of the DAPND with the participation of a VPU is set up. The VPU is composed of large-scale regulated public building’s CAC loads. To demonstrate the effectiveness of the proposed strategy, results of a sample study on a region in Nanjing which involves 22 public buildings’ CAC loads are described in this paper. Simulated results show that, by adopting the proposed DAPND scheme, the power network peak load in the region obviously decreases with a small enough deviation between the regulated load value and the dispatching instruction of the VPU. The total electricity-saving amount accounts for7.78% of total electricity consumption of the VPU before regulation.
文摘This study assessed six commercially available in-duct air cleaning devices which are designed to be mounted in the central ventilation system of offices or commercial buildings.The selected devices use different air cleaning technologies:mechanical filtration,electrostatic precipitation,gas filtration,ionization/cold plasma,photocatalytic oxidation(PCO)and catalysis under UV light.They were tested against particles,a mixture of volatile organic compounds containing acetone,acetaldehyde,toluene,heptane and formaldehyde,and two bio-contaminants:Aspergillus brasiliensis(fungus)and Staphylococcus epidermidis(bacteria).Two different test rigs were used.The single pass efficiency of each device was determined for three airflow rates,corresponding to face velocities ranging from 0.9 to 2.7 m/s,and two sets of temperature and humidity that are representative of indoor air conditions in wintertime and summertime.The concentration of the chal-lenge volatile organic compounds was also varied in the 30 to 100μg/m^(3)range as a way to characterize their influence on efficiency at realistic concentration levels for non-industrial buildings.Measurements of ozone and formaldehyde concentration downstream of the air cleaners were carried out to determine the emission rate of by-products into the air stream.Finally,the energy issue was addressed by measuring the electric power drawn and pressure loss of the devices.The results showed that two devices,namely a radiant catalytic ionizer and a plasma ionizer,had a very low single pass efficiency against all the challenge pollutants.The association of the plasma ionizer and the electrostatic precipitator did not produce a synergetic effect between the two technologies either,contrary to what their manufacturer claims.Finally,three of the six devices tested were effective in terms of pollutant removal,but only two had an acceptable energy effectiveness in view of their use in low or zero energy buildings.Their energy effectiveness ranged from a few thousand m^(3)/kWh for VOCs at the highest airflow rate(3600 m^(3)/h),to more than 60000 m^(3)/kWh for particles and bio-contaminants at 1200 or 1600 m^(3)/h.These results are at least one order of magnitude higher than the majority of stand-alone air cleaners.Moreover,they suggest that optimal IAQ and energy conditions can be achieved if variable air volume control methods are used to maintain indoor temperature and humidity.
文摘[Objective] The aim was to study the characteristics of urban air pollution on the basis of correspondence analysis.[Method] By using the correlated data from China Statistical Yearbook in 2010,a correspondence analysis on the air pollution indicators(like respirable particles,SO2 and NO2) of six provincial capitals in central-south China was carried out by means of SPSS software,and the characteristics of air pollution in the cities of China during different industrialization stages were summarized further.[Result] In the cities during early industrialization(like Nanning City and Guiyang City) and mineral resource-based cities(like Taiyuan City),the air was mainly polluted by SO2;for the cities in the middle industrialization(such as Changsha City,Wuhan City,Zhengzhou City and Chengdu City),the air was polluted by respirable particles chiefly;in the cities in late industrialization(like Guangzhou City and Shenzhen City) or completing industrialization(like Shanghai City),the air was mainly polluted by NO2;for the cities in pre-industrial stage(like Haikou City and Lhasa City),the characteristic of air pollution wasn’t obvious.[Conclusion] The study could provide references for the control of urban air pollution in China in the further.
文摘In this research, high voltage static electricity and ultraviolet technologies were integrated to an air purifying device which can be used to trap and kill airborne bacteria and viruses in central air-conditioning systems. An experimental platform was built to mimic the central air system, in which the efficacy of the newly built device was examined. In addition to the standard physical and chemical tests, bacteriophages were used to simulate airborne viruses in the experimental system. The bacteriophage suspension was aerosolized into the air with ultrasonic wave atomization.The result showed that more than 86% removal efficiency of micro-particles (<10 micron in diameter) were removed after the device was in operation in a building and more than 95% of bacteriophages in the experimental system. It is concluded that the integrated air purifier is suitable for controlling air quality and preventing virus transmission through the central air system.