期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Central environmental protection inspection and carbon emission reduction: A tripartite evolutionary game model from the perspective of carbon neutrality
1
作者 Zhen-Hua Zhang Dan Ling +2 位作者 Qin-Xin Yang Yan-Chao Feng Jing Xiu 《Petroleum Science》 SCIE EI CAS CSCD 2024年第3期2139-2153,共15页
Since the carbon neutrality target was proposed,many countries have been facing severe challenges to carbon emission reduction sustainably.This study is conducted using a tripartite evolutionary game model to explore ... Since the carbon neutrality target was proposed,many countries have been facing severe challenges to carbon emission reduction sustainably.This study is conducted using a tripartite evolutionary game model to explore the impact of the central environmental protection inspection(CEPI)on driving carbon emission reduction,and to study what factors influence the strategic choices of each party and how they interact with each other.The research results suggest that local governments and manufacturing enterprises would choose strategies that are beneficial to carbon reduction when CEPI increases.When the initial willingness of all parties increases 20%,50%—80%,the time spent for the whole system to achieve stability decreases from 100%,60%—30%.The evolutionary result of“thorough inspection,regulation implementation,low-carbon management”is the best strategy for the tripartite evolutionary game.Moreover,the smaller the cost and the larger the benefit,the greater the likelihood of the three-party game stability strategy appears.This study has important guiding significance for other developing countries to promote carbon emission reduction by environmental policy. 展开更多
关键词 central environmental protection INSPECTION Local government Manufacturing enterprise Tripartite evolutionary game Carbon emission reduction
下载PDF
Designing a Protection Scheme in Micro-Grid Systems with DG Using Central Protection Unite and Multiple Setting Group Protection Relays
2
作者 Mostafa I. Saleh Gaber El-Saady +1 位作者 Ali M. Yousef El-Noby A. Ibrahim 《Journal of Power and Energy Engineering》 2024年第9期37-49,共13页
Distributed generators now is widely used in electrical power networks, in some cases it works seasonally, and some types works at special weather conditions like photo voltaic systems and wind energy, and due to this... Distributed generators now is widely used in electrical power networks, in some cases it works seasonally, and some types works at special weather conditions like photo voltaic systems and wind energy, and due to this continuous changes in generation condition, the fault current level in network will be affected, this changes in fault current level will affect in the coordination between protection relays and to keep the coordination at right way, an adaptive protection system is required that can adaptive its setting according to generation changes, the fault current level in each case is evaluated using ETAP software, and the required relay setting in each case is also evaluated using Grey Wolf Optimizer (GWO) algorithm, and to select suitable setting which required in each condition, to select the active setting group of protection relay according to generation capacity, central protection unite can be used, and to improve protection stability and minimizing relays tripping time, a proposed method for selecting suitable backup relay is used, which leads to decrease relays tripping time and increase system stability, output settings for relays in all cases achieved our constrains. 展开更多
关键词 Directional Overcurrent Relay Protection Coordination Distributed Generators central Protection Unite Multiple Setting Group Protection Relay
下载PDF
The evolution of central environmental protection inspection policy attention in China: An investigation based on inspection reports
3
作者 Zhenhua Zhang Qianyu Liu +2 位作者 Yongxi Chen Shuai Shao Yating Tang 《Chinese Journal of Population,Resources and Environment》 2023年第4期203-211,共9页
The central environmental protection inspection (CEPI) system in China is a significant institutional innova‐tion in national environmental governance. The CEPI applies a joint supervision strategy to address salient... The central environmental protection inspection (CEPI) system in China is a significant institutional innova‐tion in national environmental governance. The CEPI applies a joint supervision strategy to address salient en‐vironmental issues and strictly enforce the environmental responsibilities of local governments. This study col‐lects and organizes CEPI inspection reports covering three stages that encompass the first round, the “look back”, and the second round, applying text analysis to obtain sample data and conduct statistical quantifica‐tion of word frequency in inspection reports and identify notable changes. The study explores the allocation of CEPI attention between policy objectives and the intensity of policy instruments. We determine that in con‐junction with public opinion feedback, the CEPI conducts targeted inspections and focuses more on pollutant governance, which has high severity and can be addressed quickly. The CEPI fills the gap of normalized gover‐nance with a campaign-style governance approach. Regarding the intensity of policy measures, the CEPI pri‐marily uses economic incentive policy instruments, supplemented by command-and-control and public guid‐ance approaches, advancing the sustainability of regulatory effectiveness through economic, social, and politi‐cal activities. This study extends knowledge in the field of CEPI policy priorities and implementation, expand‐ing the literature related to outcomes of environmental policy in developing countries. 展开更多
关键词 central environmental protection inspection Text analysis method Policy attention Policy instruments Policy objectives China
下载PDF
Environmental Protection of the Central Gas Field Development in Shaan-Gan-Ning Basin
4
作者 Xiong Yunshi (China Petroleum Planning and Engineering Institute) 《China Oil & Gas》 CAS 1998年第4期214-215,共2页
关键词 Environmental Protection of the central Gas Field Development in Shaan-Gan-Ning Basin
下载PDF
Does Chinese Environmental Policy Affect Income Inequality? Evidence from the Central Environmental Protection Inspection
5
作者 Xiaoyun Wei Chuanmin Zhao 《China & World Economy》 2024年第3期130-161,共32页
This paper investigates the effect of environmental policy on income inequality.It focuses on the central environmental protection inspection led by the central government in China.Using a diference-in-diferences appr... This paper investigates the effect of environmental policy on income inequality.It focuses on the central environmental protection inspection led by the central government in China.Using a diference-in-diferences approach,it finds evidence that environmental regulation decreased the per capita income and enlarged the gap between urban and rural income while showing an insignificant effect on employment.Although the policy can reduce pollution levels and bring environmental benefits in aggregate,the findings of this study suggest that the regulations appear to have reduced the proportion of manufacturing industry and hindered general innovation and investment from entrepreneurs,which resulted in greater inequality.Rural residents suffered more from environmental regulation due to relatively high migration costs and their disadvantaged human resources on the aspects of health,education level,and skills.The local government's execution incentive can also play a key role in the effectiveness of environmental policy.Regions with lower GDP growth targets and younger government leaders were affected significantly with regard to the income growth of local residents and the urban-rural income gap. 展开更多
关键词 central environmental protection inspection income inequality promotion incentive top-down policy urban-rural gap
原文传递
Simulation Studies of an Integrated Overcurrent Relay Protection Scheme for Distribution Systems 被引量:2
6
作者 Z.Q. Bo X.Z. Dong +1 位作者 B.H. Zhang J.H. He 《Journal of Energy and Power Engineering》 2011年第1期55-62,共8页
This paper presents an integrated protection technique for power distribution systems. A novel integrated protection scheme based on overcurrent protection technique for distribution system is described, in which a sp... This paper presents an integrated protection technique for power distribution systems. A novel integrated protection scheme based on overcurrent protection technique for distribution system is described, in which a specially designed protection relay is installed at each substation of a network and responsible for the protection of every line sections connected to the substation busbar The conventional directional overcurrent and the new adaptive accelerated protection algorithms with multiple settings are implemented into the relay to cover all the protected line sections. The paper includes studies of a typical multi section distribution network to demonstrate the principle of the scheme. Studies show that the new scheme not only offer the new protection features for individual power line section, but also provide the characteristics of integrated protection. 展开更多
关键词 Overcurrent protection integrated protection centralized protection network protection digital substation powersystem simulation.
下载PDF
Integrated Protection Scheme for Power Line
7
作者 薄志谦 施慎行 董新洲 《Transactions of Tianjin University》 EI CAS 2008年第2期79-84,共6页
This paper presents an integrated relay and its associated protection scheme for power transmission lines.The concept of integrated protection is firstly introduced,in which a centralized protection system or relay pr... This paper presents an integrated relay and its associated protection scheme for power transmission lines.The concept of integrated protection is firstly introduced,in which a centralized protection system or relay provides the protection for multiple power plants or a substation.A novel integrated protection relay based on the combination of a number of protection principles is described.In the proposed scheme,the specially designed protection relays are installed at each substation of a network and are responsible for the protection of every line section connected to the substation busbar.The combined algorithms with multiple settings are implemented into the relay to cover all the protected line sections.Simulation studies show that the proposed protection scheme is able to produce desirable performance and may offer many advantages over the existing one and great potential for future applications. 展开更多
关键词 integrated protection centralized protection transient based protection
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部