-On the basis of the hydrographic data observed within the Canary Basin in autumn 1985, temperature-salinity properties, distributions of water masses and barocltne flow field, as well as the volume transports in this...-On the basis of the hydrographic data observed within the Canary Basin in autumn 1985, temperature-salinity properties, distributions of water masses and barocltne flow field, as well as the volume transports in this area are described more detailly. The analyses indicate that the activity in the waters of the Canary Basin is mainly attributed to the interleaving and mixing between the originated water masses (e. g. Surface Water, North Atlantic Central Water, Mediterranean Water and Deep Water) and the modified water masses (Subpolar Mode Water, Labrador Sea Water and Antarctic Intermediate Water) from the outside of the study area and the variation of themselves. The east recirculation of the Subtropic Gyre in the North Atlantic consists of Azores Current and Canary Current.Azores Current is formed with several flow branches around the Azores Island, while the main flow lies at 35?N south of the Azores Island. It begins to diverge near the 15?W. The return flow found off the Portugal coast may be its northern branch. The southern invasion of the Labrador Sea Water and the Subpolar Mode Water are prevented by Azores front which serves an obvious boundary separating the North Western Atlantic (Central) Water and the North Eastern Atlantic (Central) Water.展开更多
When regulating a pipe network according to user demand,hydraulic balance and power consumption are crucial factors for a multi-source looped-pipe network applying distributed variable-speed pumps compared to the conv...When regulating a pipe network according to user demand,hydraulic balance and power consumption are crucial factors for a multi-source looped-pipe network applying distributed variable-speed pumps compared to the conventional central circulating pump system.In this paper,the influence of the fill point on power consumption and hydraulic balance of the multi-source looped-pipe network was studied.A mathematical model for electricity energy consumption analysis was built and calculated for a large sized looped-pipe network with multiple heat sources and distributed variable-speed pumps.The hydraulic calculation models of each single element,such as pipe,distribution pump,valve,replenishment pump,heat source and substation,were built.A case located in Dezhou city,China was analyzed.The results showed that:the maximum power saving(39.2%)could be achieved when each heat source had its own fill point,but the heat sources would not meet their design flows;to meet the design flows of all the heat sources,only one fill point should be necessarily located near the heat source with the lowest flow rate to get the expected hydraulic stability and energy saving.展开更多
文摘-On the basis of the hydrographic data observed within the Canary Basin in autumn 1985, temperature-salinity properties, distributions of water masses and barocltne flow field, as well as the volume transports in this area are described more detailly. The analyses indicate that the activity in the waters of the Canary Basin is mainly attributed to the interleaving and mixing between the originated water masses (e. g. Surface Water, North Atlantic Central Water, Mediterranean Water and Deep Water) and the modified water masses (Subpolar Mode Water, Labrador Sea Water and Antarctic Intermediate Water) from the outside of the study area and the variation of themselves. The east recirculation of the Subtropic Gyre in the North Atlantic consists of Azores Current and Canary Current.Azores Current is formed with several flow branches around the Azores Island, while the main flow lies at 35?N south of the Azores Island. It begins to diverge near the 15?W. The return flow found off the Portugal coast may be its northern branch. The southern invasion of the Labrador Sea Water and the Subpolar Mode Water are prevented by Azores front which serves an obvious boundary separating the North Western Atlantic (Central) Water and the North Eastern Atlantic (Central) Water.
基金This work is supported by the National Program on Key Basic Research Project of China(973 Program)(Grant No.2014CB249201).
文摘When regulating a pipe network according to user demand,hydraulic balance and power consumption are crucial factors for a multi-source looped-pipe network applying distributed variable-speed pumps compared to the conventional central circulating pump system.In this paper,the influence of the fill point on power consumption and hydraulic balance of the multi-source looped-pipe network was studied.A mathematical model for electricity energy consumption analysis was built and calculated for a large sized looped-pipe network with multiple heat sources and distributed variable-speed pumps.The hydraulic calculation models of each single element,such as pipe,distribution pump,valve,replenishment pump,heat source and substation,were built.A case located in Dezhou city,China was analyzed.The results showed that:the maximum power saving(39.2%)could be achieved when each heat source had its own fill point,but the heat sources would not meet their design flows;to meet the design flows of all the heat sources,only one fill point should be necessarily located near the heat source with the lowest flow rate to get the expected hydraulic stability and energy saving.