The interference reduction capability of cell sectoring and power control algorithms have been considered separately as means to decrease the interference in Code Division Multiple Access (CDMA) cellular systems. In t...The interference reduction capability of cell sectoring and power control algorithms have been considered separately as means to decrease the interference in Code Division Multiple Access (CDMA) cellular systems. In this paper, we present Switched-Beam (SB) and Rotatable Equal Sectoring (RES) techniques for CDMA cellular systems in a 2D urban environment. In the SB technique by using a number of fixed, independent, or directional antennas we increase the downlink capacity of the CDMA systems. Also in the RES method, the equal sectors of the base stations are rotating together to decrease the inter-cell and intra-cell interferences. Also in this paper we use centralized power control to overcome the near-far problem. Simulation results indicate that the proposed techniques considerably increase the capacity of the CDMA cellular systems compared to ordinary Equal Sectoring (ES) method.展开更多
Objective:To analyze the effect of quality control circle on the central sterile supply department(CSSD).Methods:The control group and the observation group each consisted of 180 instruments received by the sterilizat...Objective:To analyze the effect of quality control circle on the central sterile supply department(CSSD).Methods:The control group and the observation group each consisted of 180 instruments received by the sterilization supply center from January to March 2023 and 11 CSSD staff.The control group underwent routine management while quality control circle was implemented in the observation group.The quality of work,disinfection and sterilization qualification rates,disinfection and sterilization of various instruments,cleaning indicators,and management satisfaction of both groups were compared.Results:The observation group scored higher in terms of work quality,the qualification rate of disinfection and sterilization in each link,the disinfection and sterilization of instruments,and cleaning indicators compared to the control group.Besides,the management satisfaction of the observation group was higher than that of the control group(P<0.05).Conclusion:A quality control circle ensures the quality of work,improves the cleaning,disinfection,and sterilization of instruments of the CSSD,and improves the management satisfaction of the CSSD staff.展开更多
This study presents a centralized control scheme that coordinates parallel operations of power conditioning system(PCS)for the grid interactions of electric vehicles(EVs)in EV charge-discharge and storage integration ...This study presents a centralized control scheme that coordinates parallel operations of power conditioning system(PCS)for the grid interactions of electric vehicles(EVs)in EV charge-discharge and storage integration station.Key issues for the control and operation of PCS under various operation modes are discussed,including vehicle to grid(V2G)mode,stand-alone mode and seamless transfer mode.The intelligent multi-mode charge-discharge method is utilized for the V2G mode,and the parallel control method based on communication network is adopted for the standalone mode.In addition,a novel seamless transfer strategy is proposed,which is able to implement PCS transition between V2G mode and stand-alone mode.The detailed process of the seamless transfer between the two modes is illustrated.Experimental results are presented to show the performance and feasibility of this strategy.展开更多
文摘The interference reduction capability of cell sectoring and power control algorithms have been considered separately as means to decrease the interference in Code Division Multiple Access (CDMA) cellular systems. In this paper, we present Switched-Beam (SB) and Rotatable Equal Sectoring (RES) techniques for CDMA cellular systems in a 2D urban environment. In the SB technique by using a number of fixed, independent, or directional antennas we increase the downlink capacity of the CDMA systems. Also in the RES method, the equal sectors of the base stations are rotating together to decrease the inter-cell and intra-cell interferences. Also in this paper we use centralized power control to overcome the near-far problem. Simulation results indicate that the proposed techniques considerably increase the capacity of the CDMA cellular systems compared to ordinary Equal Sectoring (ES) method.
文摘Objective:To analyze the effect of quality control circle on the central sterile supply department(CSSD).Methods:The control group and the observation group each consisted of 180 instruments received by the sterilization supply center from January to March 2023 and 11 CSSD staff.The control group underwent routine management while quality control circle was implemented in the observation group.The quality of work,disinfection and sterilization qualification rates,disinfection and sterilization of various instruments,cleaning indicators,and management satisfaction of both groups were compared.Results:The observation group scored higher in terms of work quality,the qualification rate of disinfection and sterilization in each link,the disinfection and sterilization of instruments,and cleaning indicators compared to the control group.Besides,the management satisfaction of the observation group was higher than that of the control group(P<0.05).Conclusion:A quality control circle ensures the quality of work,improves the cleaning,disinfection,and sterilization of instruments of the CSSD,and improves the management satisfaction of the CSSD staff.
基金This work was supported in part by the National Natural science Foundation of China under Grant 51361130150 and Grant 51477067in part by the Fundamental Research Funds for the Central Universities under Grant 2014QN219.
文摘This study presents a centralized control scheme that coordinates parallel operations of power conditioning system(PCS)for the grid interactions of electric vehicles(EVs)in EV charge-discharge and storage integration station.Key issues for the control and operation of PCS under various operation modes are discussed,including vehicle to grid(V2G)mode,stand-alone mode and seamless transfer mode.The intelligent multi-mode charge-discharge method is utilized for the V2G mode,and the parallel control method based on communication network is adopted for the standalone mode.In addition,a novel seamless transfer strategy is proposed,which is able to implement PCS transition between V2G mode and stand-alone mode.The detailed process of the seamless transfer between the two modes is illustrated.Experimental results are presented to show the performance and feasibility of this strategy.