This paper describes the field tests carried out to evaluate the new Vicon RS-EDW centrifugal fertilizer spreader, to be used in Precision Agriculture. The results of initial dynamic calibration tests showed a signifi...This paper describes the field tests carried out to evaluate the new Vicon RS-EDW centrifugal fertilizer spreader, to be used in Precision Agriculture. The results of initial dynamic calibration tests showed a significant and systematic difference between the application rates of the two discs (about 20%). This difference had to be corrected by the manufacturer that carried out the necessary changes to the electric actuators. The fertilizer spreader had good distribution homogeneity, considering different working velocities and different positions in the parcel. The pattern distribution curve for 18% super phosphate fertilizer led to an effective working width of 28 meters, with a coefficient of variation of 15%. The longitudinal test, under experimental working conditions led to a machine delay time of 6-7 seconds. The results show an actual fertilization application density between 74%-90% of that determined for each location. These results confirm that the spreader can be used to spread fertilizer differentially in the field.展开更多
文摘This paper describes the field tests carried out to evaluate the new Vicon RS-EDW centrifugal fertilizer spreader, to be used in Precision Agriculture. The results of initial dynamic calibration tests showed a significant and systematic difference between the application rates of the two discs (about 20%). This difference had to be corrected by the manufacturer that carried out the necessary changes to the electric actuators. The fertilizer spreader had good distribution homogeneity, considering different working velocities and different positions in the parcel. The pattern distribution curve for 18% super phosphate fertilizer led to an effective working width of 28 meters, with a coefficient of variation of 15%. The longitudinal test, under experimental working conditions led to a machine delay time of 6-7 seconds. The results show an actual fertilization application density between 74%-90% of that determined for each location. These results confirm that the spreader can be used to spread fertilizer differentially in the field.