In this study,a compact 16-channel integrated charge-sensitive preamplifier named the smart preamplifier(SPA)was developed to support the large-scale detector array used in modern nuclear physics experiments.Two types...In this study,a compact 16-channel integrated charge-sensitive preamplifier named the smart preamplifier(SPA)was developed to support the large-scale detector array used in modern nuclear physics experiments.Two types of SPA,namely SPA02 and SPA03(with external field effect transistor),have been manufactured to match silicon detectors with small and large capacitances,respectively.The characteristics of the SPA include fast response of typically less than 6 ns for pulse rising time and low equivalent noise of 1.5 keV at zero input capacitance.The energy sensitivity and pulse decay time can be easily adjusted by changing the feedback capacitance Cfand resistance Rfin various applications.A good energy resolution of 24.4 keV for 5.803-MeV alpha particles from 244 Cm was achieved using a small-sized Si-PIN detector;for the silicon strip detectors in the test with the alpha source,a typical energy resolution of 0.6–0.8%was achieved.The integrated SPA has been employed in several experiments of silicon strip detectors with hundreds of channels,and a good performance has been realized.展开更多
Preamplifier circuit noise is of great importance in quartz enhanced photoacoustic spectroscopy (QEPAS) system. In this paper, several noise sources are evaluated and discussed in detail. Based on the noise characte...Preamplifier circuit noise is of great importance in quartz enhanced photoacoustic spectroscopy (QEPAS) system. In this paper, several noise sources are evaluated and discussed in detail. Based on the noise characteristics, the corresponding noise reduction method is proposed. In addition, a frequency locked technique is introduced to further optimize the QEPAS system noise and improve signal, which achieves a better performance than the conventional frequency scan method. As a result, the signal-to-noise ratio (SNR) could be increased 14 times by utilizing frequency locked technique and numerical averaging technique in the QEPAS system for water vapor detection.展开更多
介绍了一种用于个人γ剂量测量的微型硅探测器的信号处理电路的设计,讨论了PCB(印制电路板)设计中应注意的问题。该信号处理电路主要包括前置放大电路、滤波成形电路和极-零相消电路,前置放大电路采用了电荷灵敏前置放大器,滤波成形电...介绍了一种用于个人γ剂量测量的微型硅探测器的信号处理电路的设计,讨论了PCB(印制电路板)设计中应注意的问题。该信号处理电路主要包括前置放大电路、滤波成形电路和极-零相消电路,前置放大电路采用了电荷灵敏前置放大器,滤波成形电路采用了CR-RC滤波成形网络。设计的信号处理电路PCB面积仅有10 cm2,对于0.662 Me V的γ射线,信号处理电路的输出信号的信噪比达到了50:1,输出脉冲幅度达到了1.5 V左右,输出信号之后没有明显的下冲现象,其性能可以满足用于个人剂量测量的要求。展开更多
基金supported by the National Key R&D Program of China(No.2018YFA0404404)the National Natural Science Foundation of China(Nos.11635015,U1732145,11705285,11805280,U1867212,and 11961131012)the Continuous Basic Scientific Research Project(No.WDJC-2019-13).
文摘In this study,a compact 16-channel integrated charge-sensitive preamplifier named the smart preamplifier(SPA)was developed to support the large-scale detector array used in modern nuclear physics experiments.Two types of SPA,namely SPA02 and SPA03(with external field effect transistor),have been manufactured to match silicon detectors with small and large capacitances,respectively.The characteristics of the SPA include fast response of typically less than 6 ns for pulse rising time and low equivalent noise of 1.5 keV at zero input capacitance.The energy sensitivity and pulse decay time can be easily adjusted by changing the feedback capacitance Cfand resistance Rfin various applications.A good energy resolution of 24.4 keV for 5.803-MeV alpha particles from 244 Cm was achieved using a small-sized Si-PIN detector;for the silicon strip detectors in the test with the alpha source,a typical energy resolution of 0.6–0.8%was achieved.The integrated SPA has been employed in several experiments of silicon strip detectors with hundreds of channels,and a good performance has been realized.
基金This work was supported by the National Natural Science Foundation of China (Grant Nos. 61405105 & 61475085), the Shandong Provincial Natural Science Foundation, China (Grant No. ZR2014FQ015), Science and Technology Development Project of Shandong Province (Grant No. 2014GGX101007), and the Fundamental Research Funds of Shandong University (Grant Nos. 2014HW016 & 2014YQ011).
文摘Preamplifier circuit noise is of great importance in quartz enhanced photoacoustic spectroscopy (QEPAS) system. In this paper, several noise sources are evaluated and discussed in detail. Based on the noise characteristics, the corresponding noise reduction method is proposed. In addition, a frequency locked technique is introduced to further optimize the QEPAS system noise and improve signal, which achieves a better performance than the conventional frequency scan method. As a result, the signal-to-noise ratio (SNR) could be increased 14 times by utilizing frequency locked technique and numerical averaging technique in the QEPAS system for water vapor detection.
文摘介绍了一种用于个人γ剂量测量的微型硅探测器的信号处理电路的设计,讨论了PCB(印制电路板)设计中应注意的问题。该信号处理电路主要包括前置放大电路、滤波成形电路和极-零相消电路,前置放大电路采用了电荷灵敏前置放大器,滤波成形电路采用了CR-RC滤波成形网络。设计的信号处理电路PCB面积仅有10 cm2,对于0.662 Me V的γ射线,信号处理电路的输出信号的信噪比达到了50:1,输出脉冲幅度达到了1.5 V左右,输出信号之后没有明显的下冲现象,其性能可以满足用于个人剂量测量的要求。