The electrocatalytic oxidation of methanol at the platinum electrode modified with Eu-Fe cyanide-bridged binuclear complexes (Eu-Fe film) was investigated for the first time by cyclic voltammetry.Compared with the bar...The electrocatalytic oxidation of methanol at the platinum electrode modified with Eu-Fe cyanide-bridged binuclear complexes (Eu-Fe film) was investigated for the first time by cyclic voltammetry.Compared with the bare platinum electrode,the results showed that the modified electrode had excellent electrocatalytic activity for the oxidation of methanol;the oxidation peak potential shifted more negatively and the peak current increased about twenty times.The electrooxidation of methanol at the modified el...展开更多
In the present work,a chemically modified electrode has been fabricated utilizing Bi_(2)O_(3)/ZnO nanocomposite.The nanocomposite was synthesized by simple sonochemical method and characterized for its structural and ...In the present work,a chemically modified electrode has been fabricated utilizing Bi_(2)O_(3)/ZnO nanocomposite.The nanocomposite was synthesized by simple sonochemical method and characterized for its structural and morphological properties by using XRD,FESEM,EDAX,HRTEM and XPS techniques.The results clearly indicated co-existence of Bi_(2)O_(3) and ZnO in the nanocomposite with chemical interaction between them.Bi_(2)O_(3)/ZnO nanocomposite based glassy carbon electrode(GCE)was utilized for sensitive voltammetric detection of an anti-biotic drug(balofloxacin).The modification amplified the electroactive surface area of the sensor,thus providing more sites for oxidation of analyte.Cyclic and square wave voltammograms revealed that Bi_(2)O_(3)/ZnO modified electrode provides excellent electrocatalytic action towards balofloxacin oxidation.The current exhibited a wide linear response in concentration range of 150e1000 nM and detection limit of 40.5 nM was attained.The modified electrode offered advantages in terms of simplicity of preparation,fair stability(RSD 1.45%),appreciable reproducibility(RSD 2.03%)and selectivity.The proposed sensor was applied for determining balofloxacin in commercial pharmaceutical formulations and blood serum samples with the mean recoveries of 99.09% and 99.5%,respectively.展开更多
基金the Project of Natural Science Foundation of Gansu Province of their financial supports(No. 096RJZA117)
文摘The electrocatalytic oxidation of methanol at the platinum electrode modified with Eu-Fe cyanide-bridged binuclear complexes (Eu-Fe film) was investigated for the first time by cyclic voltammetry.Compared with the bare platinum electrode,the results showed that the modified electrode had excellent electrocatalytic activity for the oxidation of methanol;the oxidation peak potential shifted more negatively and the peak current increased about twenty times.The electrooxidation of methanol at the modified el...
文摘In the present work,a chemically modified electrode has been fabricated utilizing Bi_(2)O_(3)/ZnO nanocomposite.The nanocomposite was synthesized by simple sonochemical method and characterized for its structural and morphological properties by using XRD,FESEM,EDAX,HRTEM and XPS techniques.The results clearly indicated co-existence of Bi_(2)O_(3) and ZnO in the nanocomposite with chemical interaction between them.Bi_(2)O_(3)/ZnO nanocomposite based glassy carbon electrode(GCE)was utilized for sensitive voltammetric detection of an anti-biotic drug(balofloxacin).The modification amplified the electroactive surface area of the sensor,thus providing more sites for oxidation of analyte.Cyclic and square wave voltammograms revealed that Bi_(2)O_(3)/ZnO modified electrode provides excellent electrocatalytic action towards balofloxacin oxidation.The current exhibited a wide linear response in concentration range of 150e1000 nM and detection limit of 40.5 nM was attained.The modified electrode offered advantages in terms of simplicity of preparation,fair stability(RSD 1.45%),appreciable reproducibility(RSD 2.03%)and selectivity.The proposed sensor was applied for determining balofloxacin in commercial pharmaceutical formulations and blood serum samples with the mean recoveries of 99.09% and 99.5%,respectively.