期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Reply to 'Statistical testing and distribution for lead chloride toxicity'
1
作者 Maria de Lourdes Pereira J.Ramalho-Santos 《Asian Journal of Andrology》 SCIE CAS CSCD 2005年第1期108-108,共1页
We are very grateful for the letter written by Dr Lange,and indeed apologize for the mistakes noted in the word-ing of our text regarding statistical analysis.This wasdue to changes carried out while revising the manu... We are very grateful for the letter written by Dr Lange,and indeed apologize for the mistakes noted in the word-ing of our text regarding statistical analysis.This wasdue to changes carried out while revising the manuscriptat the request of reviewers,whom we thank for,point-ing out several issues that were actually similar to thosenoted by Dr.Lange.Unfortunately,we were unable todescribe and discuss our findings properly in the context 展开更多
关键词 TEST Statistical testing and distribution for lead chloride toxicity Reply to
下载PDF
Deposition behavior of residual aluminum in drinking water distribution system:Effect of aluminum speciation 被引量:5
2
作者 Yue Zhang Baoyou Shi +3 位作者 Yuanyuan Zhao Mingquan Yan Darren A.Lytle Dongsheng Wang 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2016年第4期142-151,共10页
Finished drinking water usually contains some residual aluminum.The deposition of residual aluminum in distribution systems and potential release back to the drinking water could significantly influence the water qual... Finished drinking water usually contains some residual aluminum.The deposition of residual aluminum in distribution systems and potential release back to the drinking water could significantly influence the water quality at consumer taps.A preliminary analysis of aluminum content in cast iron pipe corrosion scales and loose deposits demonstrated that aluminum deposition on distribution pipe surfaces could be excessive for water treated by aluminum coagulants including polyaluminum chloride(PACl).In this work,the deposition features of different aluminum species in PACl were investigated by simulated coil-pipe test,batch reactor test and quartz crystal microbalance with dissipation monitoring.The deposition amount of non-polymeric aluminum species was the least,and its deposition layer was soft and hydrated,which indicated the possible formation of amorphous Al(OH)3.Al(13) had the highest deposition tendency,and the deposition layer was rigid and much less hydrated,which indicated that the deposited aluminum might possess regular structure and self-aggregation of Al(13)could be the main deposition mechanism.While for Al(30),its deposition was relatively slower and deposited aluminum amount was relatively less compared with Al(13).However,the total deposited mass of Al(30) was much higher than that of Al(13),which was attributed to the deposition of particulate aluminum matters with much higher hydration state.Compared with stationary condition,stirring could significantly enhance the deposition process,while the effect of pH on deposition was relatively weak in the near neutral range of 6.7 to 8.7. 展开更多
关键词 Aluminum deposition Drinking water distribution system Polyaluminum chloride (PACl) Quartz crystal microbalance
原文传递