Liquid-liquid extraction-thin layer chromatography (LLE-TLC) has been a common and routine combined method for detection of drugs in biological materials. Solid-phase extraction (SPE) is gradually replacing the tr...Liquid-liquid extraction-thin layer chromatography (LLE-TLC) has been a common and routine combined method for detection of drugs in biological materials. Solid-phase extraction (SPE) is gradually replacing the tra- ditional LLE method. High performance thin layer chromatography (HPTLC) has several advantages over TLC. The present work studied the higher efficiency of a new SPE-HPTLC method over that of a routine LLE-TLC method, in extraction and detection of urinary morphine. Fifty-eight urine samples, primarily identified as mor- phine-positive samples by a strip test, 'were re-screened by LLE-TLC and SPE-HPTLC. The results of LLE-TLC and SPE-HPTLC were then compared with each other. The results showed that the SPE-HPTLC detected 74% of total samples as morphine-positive samples whereas the LLE-TLC detected 48% of the same samples. We further discussed the effect of codeine abuse on TLC analysis of urinary morphine. Regarding the importance of morphine detection in urine, the present combined SPE-HPTLC method is suggested as a replacement method for detection of urinary morphine by many reference laboratories.展开更多
The present study describes guanidinium-based ionic liquids(GBILs) as stationary phases for capillary gas chromatography (CGC) and to the best of our knowledge,no related reports are available up to now.In this st...The present study describes guanidinium-based ionic liquids(GBILs) as stationary phases for capillary gas chromatography (CGC) and to the best of our knowledge,no related reports are available up to now.In this study,a hexaalkylguanidinium ionic liquid(DOTMG-NTf;) was synthesized and coated statically onto capillary columns.Selectivity of the stationary phase was evaluated by separating Grob test mixture,test mixture,alcohols mixture,and fatty acid methyl esters mixture,and thermal stability was investigated as well.The present study demonstrates that GBILs as CGC stationary phases exhibit satisfactory selectivity and thermal stability and have a great potential as new candidates for CGC stationary phases.展开更多
The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples...The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples were extracted with 0.2%formic acid acetonitrile solution,purified by on-line SPE device with HLB column,then separated by XBridge C18 column,using 0.1%formic acid solution and acetonitrile as the mobile phase.Mass spectrometric data was acquired under multiple reaction monitoring(MRM)mode using positive ionization electrospray.Internal standard method was used in the quantification,good linear relationship was got in range of 0.1–100 ng/mL and correlation coefficient was higher than 0.9990.The limits of detection were in the range of 0.125–2.00g/kg and the limits of quantitation were in the range of 0.250–5.00g/kg.Recoveries of the method were in range of 78.3%–99.3%,relative standard deviation were lower than 10%.The method was simple,sensitivity,and could be used for routine supervision and analysis of fifteen sulfonamides in pork and fish.展开更多
One chloride-terminated ionic liquid(CTIL) and two hydroxyl-terminated ionic liquids(HTILs) were synthesized and used as stationary phases for capillary gas chromatography(CGC).Molecular interactions of these st...One chloride-terminated ionic liquid(CTIL) and two hydroxyl-terminated ionic liquids(HTILs) were synthesized and used as stationary phases for capillary gas chromatography(CGC).Molecular interactions of these stationary phases were evaluated by Abraham solvation parameter model,indicating that the CTIL exhibits remarkably strong H-bond basicity and the HTILs possess both H-bond basicity and acidity.The molecular interactions were further confirmed by separation of a complex mixture consisting of ketones,aldehydes,esters,alcohols and aromatic compounds.It was found that the obtained solvation parameters correlate well with the chromatographic performances of the analytes in terms of elution order and resolution.The well correlated relationship between the solvation parameters and the selectivity of the CTIL and HTILs stationary phases is quite helpful in predicting and understanding the retention behaviors of different types of analytes on these stationary phases.展开更多
To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated first...To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated firstly,and the expanded uncertainty was calculated finally.The results show that when MC-LR concentration in the water samples was 0.50 μg/L,the expanded uncertainty was 0.00628 μg/L(k=2).展开更多
A new, rapid and efficient reverse phase Liquid Chromatography (RP-LC) method was developed for determination of Gibberellin A4 (GA4) in samples of flower stalk of Dasylirion cedrosanum and vegetative tissue of Epithe...A new, rapid and efficient reverse phase Liquid Chromatography (RP-LC) method was developed for determination of Gibberellin A4 (GA4) in samples of flower stalk of Dasylirion cedrosanum and vegetative tissue of Epithelantha micromeris. Purification of GA4 was carried out by solid phase extraction (SPE), in Epithelantha micromeris. In the chromatography method was obtaining a retention time of 2.1 min, using Hypersil GOLD C-18 column (100 × 4.6 mm dim and size particle 5 μ), mobile phase 50/50 acetonitrile/water and a flow 1.0 ml/min. Detection was carried out by a UV detector set at 205 nm, and a quantization limit of 0.4 mg/L. The obtained correlation coefficient was 0.995.展开更多
Based on the intersection point rule of the retention value and normal boiling point of homologues in reversed-phase high-performance liquid chromatography(RPLC), the intersection point rule of the retention value of ...Based on the intersection point rule of the retention value and normal boiling point of homologues in reversed-phase high-performance liquid chromatography(RPLC), the intersection point rule of the retention value of homologues and mobile phase composition has been derived, and was testified by a lot of experimental data from the literature. With this newly proposed equation, we can use the retention value of the compound in one mobile phase composition to predict its retention value in any other mobile phase composition. For fourteen groups of homologues in five mobile phase compositions on five Kinds of columns, the overall average absolute error of 721 data sets is 2.8%.展开更多
An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matog...An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matography(HPLC) and solid-phase extraction(SPE). The aim of this study was to obtain an effective method with high preparative efficiency and importantly to avoid the transformation of unstable compounds. The preparative HPLC system was based on an LC/MS controlled four-channel autopurification system. The SPE method was performed with a C18 packing material to trap the target compounds and to remove the acidic additive derived from the mobile phase. Using this method, the unstable iridoid glucosides(IGs) as model compounds were successfully isolated and purified from the extract of Hedyotis diffusa Willd. Six IGs(including one new minor IG) and one nucleotide compound were simultaneously obtained, each with a purity of 91% as determined by HPLC. The structures of the isolated compounds were identified by UPLC/Q-TOF MS, UV, 1D and/or 2D NMR. It was demonstrated that the combination of preparative HPLC with SPE is a versatile tool for preparative purification of unstable compounds from complex natural products.展开更多
A new reversed-phase high performance liquid chromatography method was developed to quantitate the activity of xanthine oxidase involved in milk fat globule membrane with xanthine as the substrate and the separation o...A new reversed-phase high performance liquid chromatography method was developed to quantitate the activity of xanthine oxidase involved in milk fat globule membrane with xanthine as the substrate and the separation of product (uric acid). The increment of uric acid in the reaction system was used to calculate the total activity of XO. The optimized assay conditions, linearity of detection, recovery of uric acid and chromatogram were developed in text, indicating this method is simple, rapid and efficient. It is an alternative potential method for the determination of the activity of XO in milk.展开更多
A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromato...A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromatography was performed on a Purospher? Star, C18 (5 mm, 250 × 4.6 mm) column using acetonitrile: buffer (0.01 mM) (40:60, v/v, pH adjusted to 3.0), as a mobile phase. The mobile phase was pumped at a flow rate of 1.0 mL·min-1 and UV detection was performed at 240 nm. The method was validated for linearity, accuracy, precision and specificity. The method was applied to study the interaction between amlodipine and H1-receptor antagonists. These interactions were carried out in simulated gastric juice (pH 1), simulated full stomach (pH 4), blood pH (pH 7.4) and simulating GI (pH 9). The interacting drugs were heated at 37℃ with intermit-tent shaking and the samples were withdrawn every thirty minutes for three hours and drug contents were analyzed by RP-HPLC techniques. In most cases the in vitro availability of amlodipine was decreased. It was observed that the change in in vitro availability was pH dependent.展开更多
A new type of HPLC stationary phase containing thymine derivative was successfully prepared.It was found to give selective separation of nucleic acid bases and several purine derivatives,such as caffeine and theophyll...A new type of HPLC stationary phase containing thymine derivative was successfully prepared.It was found to give selective separation of nucleic acid bases and several purine derivatives,such as caffeine and theophylline.The retention behaviour and elution order of the solutes were interpreted in terms of molecular structure.展开更多
A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet de...A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet detection(UV)is proposed,and it was applied to determine the seven active compounds in Salvia Miltiorrhiza herb.SGSIL and ionic liquid[BMIM]BF4 were used as the adsorbent and the green elution reagent in the MSPD procedure.Several extraction conditions including type of filler and elution solvent,the volume of elution solvent,material liquid ratio were optimized.Under the optimum conditions,the SGSIL-MSPD-HPLC method showed a low limit of detection(LOD,S/N=3)of 0.0122-0.8788μg/mL for standard solution,limit of quantification(LOQ,S/N=10)of 0.0406-2.9292μg/mL for standard solution,wide linear range from 1.56 to 2000μg/mL for all compounds for standard solution,correlation coefficients(r)of more than 0.9990,acceptable reproducibility(relative standard deviations,RSDs<3.54%),and precision of RSDs<3.36%for intra-day,RSDs<3.50%for inter-day.The satisfactory recoveries ranged from 96.4 to 102.5,with RSDs less than 3.45%.The developed SGSIL-MSPD method is easier and more suitable for the determination of the seven active compounds in Salvia Miltiorrhiza herb than the traditional ultrasonic extraction.It was an effective and efficient method for the extraction and quantification of the seven active compounds in traditional Chinese herbal samples.展开更多
AIM:To determine moxonidine in aqueous humor and iris-ciliary body by reversed-phase high performance liquid chromatography(RP-HPLC),and to evaluate the retinal neuroprotective effect after topical administration with...AIM:To determine moxonidine in aqueous humor and iris-ciliary body by reversed-phase high performance liquid chromatography(RP-HPLC),and to evaluate the retinal neuroprotective effect after topical administration with moxonidine in a high intraocular pressure(IOP)model.METHODS:The eyes of albino rabbits were administered topically and ipsilaterally with 0.2%moxonidine.A RPHPLC method was employed for the identification and quantification of moxonidine between 2 and 480 min,which presented in the aqueous humor and iris-ciliary body.Flash electroretinography(F-ERG)amplitude and superoxide dismutase(SOD)level were measured between day 1 and day 15 after topical administration with moxonidine in a rabbit model of high IOP.Histological and ultrastructural observation underwent to analyze the changes of retinal morphology,the inner retinal layers(IRL)thickness,and retinal ganglion cell(RGC)counting.RESULTS:Moxonidine was detectable between 2 and 480 min after administration,and the peak concentration developed both in the two tissues at 30 min,0.51μg/m Lin aqueous humor and 1.03μg/g in iris-ciliary body.In comparison to control,F-ERG b-wave amplitude in moxonidine eyes were significantly differences between day 3 and day 15(P<0.01)in the high IOP model;SOD levels were significantly higher at all time-points(P<0.01)with a maximum level of 20.29 U/mgprot at day 15;and RGCs were significantly higher(P<0.05).CONCLUSION:Moxonidine is a viable neuroprotective agent with application to high IOP model.All layers of retina,including RGC layer,retinal nerve fiber layer and INL,are more preserved after moxonidine administration.SOD plays a neuroprotective role in ocular hypertension-mediated RGC death.展开更多
[Objective] To develop a solid phase extraction-high performance liquid chromatography-fluorescence method for determination of quin- olone antibiotics in water. [ Metbod] The standard curves of four quinolones (norf...[Objective] To develop a solid phase extraction-high performance liquid chromatography-fluorescence method for determination of quin- olone antibiotics in water. [ Metbod] The standard curves of four quinolones (norfloxacin, ciprofloxacin, Iomefloxacin and enrofloxacin) were pre- pared. The detection limit in water and recovery were determined. The water samples collected from different areas, river and tap water were trea- ted using solid-phese extraction method and analyzed by high performance liquid chromatography. Then the concentration of quinolones antibiotics was determined by fluorescence method. [ Result] The detection limit of quinolone antibiotics in water was 0.083 -0.248 μg/L, and their recovery was 63.7% -134.1%. The four quinolone antibiotics at different levels were detected in various water samples, and the total concentration of quin- olone antibiotics was 0.045 -3.969 μg/L. The total concentration of quinolone antibiotics was higher in the water samples collected from rivers in Shenzhen area than in the sewage samples. The four quinolone antibiotics could be detected in all tap water samples. [ CoaduLsion ] The solid phase extraction-high performance liquid chromatography-fluorescence method is feasible and effective to detect quinolones in water. In addition, this method needs low cost and can meet requirements of daily monitorina and analysis.展开更多
Titania microspheres were synthesized using hydrothermal methods to exploit a new liquid chromatography stationary phase. The prepared titania microspheres were approximately 7 μm in diameter, and the particle size d...Titania microspheres were synthesized using hydrothermal methods to exploit a new liquid chromatography stationary phase. The prepared titania microspheres were approximately 7 μm in diameter, and the particle size distribution was relatively narrow and uniform. Furthermore, the average specific surface area was 276.0 m2·g·1, the average pore volume was approximately 0.25 mL·g·1, and the pore diameter was approximately 35.9 nm for sintering titania microspheres. These parameters indicate that the titania microspheres prepared for this study have excellent surface properties for chromatography. Additionally, columns filled with the titania microspheres were able to separate basic compounds, including benzene, nitrobenzene and o-nitroanisole. It could be proposed that the titania microspheres prepared for this study would be a promising stationary phase for liquid chromatography.展开更多
The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamox...The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamoxifen (TAM) in biological fluids including human urine and plasma. The drug was extracted from a 15 mL aqueous sample (source phase;SP) into an organic phase impregnated in the pores of the hollow fiber (membrane phase;MP) followed by the back-extraction into a second aqueous solution (receiving phase;RP) located in the lumen of the hollow fiber. The effects of several factors such as the nature of organic solvent, compositions of SP and RP solutions, extraction time, ionic strength and stirring rate on the extraction efficiency were examined and optimized. An enrichment factor of 360 along with substantial sample clean up was obtained under the optimized conditions. The calibration curve showed linearity in the range of 1 - 500 ng?mL–1 and the limit of detection was found to be 0.5 ng?mL–1 in aqueous medium. A reasonable relative recovery (≥89%) and satisfactory intra-assay (3.7% - 4.2%, n = 3) and inter-assay (7.5% - 7.8%, n = 3) precision illustrated good performance of the analytical procedure in spiked human urine and plasma samples.展开更多
Modern porous monoliths have been conceived as a new class of stationary phases for high performance liquid chromatography(HPLC) in classical columns in the early 1990s and later extended to the capillary format.These...Modern porous monoliths have been conceived as a new class of stationary phases for high performance liquid chromatography(HPLC) in classical columns in the early 1990s and later extended to the capillary format.These monolithic materials are prepared using simple processes carried out in an external mold(inorganic monoliths) or within the confines of the column(organic monoliths and all capillary columns).These methods afford macroporous materials with large through-pores that enable applications in a rapid flow-through mode.Since all the mobile phase must flow through the monolith,the convection considerably accelerates mass transport within the monolithic separation medium and improves the separations.As a result,the monolithic columns perform well even at very high flow rates.The applications of monolithic capillary columns are demonstrated on numerous separations in the HPLC mode.展开更多
A rapid, sensitive and specific ultra-high-performance liquid chromatography tandem mass spectrometry (UPLC-MS) method was developed for the analysis of tetracycline antibiotics, including tetracycline (TC), oxyte...A rapid, sensitive and specific ultra-high-performance liquid chromatography tandem mass spectrometry (UPLC-MS) method was developed for the analysis of tetracycline antibiotics, including tetracycline (TC), oxytetracycline (OTC), chlortetracycline (CTC) and their 4-epimers (4-epiTCs) in agricultural soil fertilized with swine manure. Soil samples were extracted and cleaned-up with 10 mL EDTA-McIlvaine buffer solution (pH 4.0), then cleaned-up and pre-concentrated using the Oasis MAX cartridge and then eluted with 1 mL solution by mixing formic acid, methanol and water at a ratio of 2:15:83 (v/v/v). The purified samples were separated by an ACQUITY UPLC BEH C18 column using acetonitrile and water containing 0.1% formic acid mobile phase and detected by a single quadrupole MS. The limits of detection for the soil extraction method (LODsoil) ranged from 0.6-2.5 lag kg-~ with recoveries from 23.3-159.2%. Finally, the method was applied to an agricultural field in an area with intensive pig-fattening farming. Tetracyclines were detected in soil from 2.8 to 42.4 μg kg-1 soil. These results demonstrate that soil from swine farms can become severely contaminated with tetracycline antibiotics and their metabolites.展开更多
A new ionic liquids grafted polysiloxane used as stationary phase for capillary gas chromatography (CGC) is described. The stationary phase of 1-vinyl-3-hexylimidazolium hexafluorophosphate anchored to polysiloxane ...A new ionic liquids grafted polysiloxane used as stationary phase for capillary gas chromatography (CGC) is described. The stationary phase of 1-vinyl-3-hexylimidazolium hexafluorophosphate anchored to polysiloxane (PMHS-[VHIm][PF6]) was synthe- sized, characterized and coated onto capillary columns by static coating. The results show that the present stationary phase exhibits a very good chromatographic resolution and selectivity for Grob test mixture and alcohols with baseline resolution and symmetry peaks. The present work suggests that novel stationary phase has a great potential for further development and application. 2009 Mei Ling Qi. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.展开更多
A guanidinium ionic liquid,N,N,N',N'-tetrahexyl-N",N"-dimethylguanidinium bis(trifluoromethane)sulfonylimide(THDMGNTf2), was synthesized and used as stationary phase for capillary gas chromatography.In compari...A guanidinium ionic liquid,N,N,N',N'-tetrahexyl-N",N"-dimethylguanidinium bis(trifluoromethane)sulfonylimide(THDMGNTf2), was synthesized and used as stationary phase for capillary gas chromatography.In comparison with imidazolium ionic liquid stationary phase,the present new stationary phase exhibits quite different selectivity and behaves more like a low polar stationary phase.The guanidinium ionic liquid of THDMG-NTf2 exhibited better separation of Grab test mixture than imidazolium ionic liquid of 1-octyl-3-butylimidazolium bis(trifluoromethane)sulfonylimide(OBIM-NTf2).Solvation parameter model was also used to evaluate the selectivity of THDMG-NTf2.Additionally,essential oil of Magnolia biondii Pamp was analyzed to further evaluate the selectivity of THDMG-NTf2 for a sample of complicated components.Satisfactory separation of the essential oil was achieved on a THDMG-NTf2 column(10 m) while using a commercial column(30 m) as reference.The present study shows that the guanidinium ionic liquid possesses novel chromatographic selectivity and has great potential for wide applications.展开更多
文摘Liquid-liquid extraction-thin layer chromatography (LLE-TLC) has been a common and routine combined method for detection of drugs in biological materials. Solid-phase extraction (SPE) is gradually replacing the tra- ditional LLE method. High performance thin layer chromatography (HPTLC) has several advantages over TLC. The present work studied the higher efficiency of a new SPE-HPTLC method over that of a routine LLE-TLC method, in extraction and detection of urinary morphine. Fifty-eight urine samples, primarily identified as mor- phine-positive samples by a strip test, 'were re-screened by LLE-TLC and SPE-HPTLC. The results of LLE-TLC and SPE-HPTLC were then compared with each other. The results showed that the SPE-HPTLC detected 74% of total samples as morphine-positive samples whereas the LLE-TLC detected 48% of the same samples. We further discussed the effect of codeine abuse on TLC analysis of urinary morphine. Regarding the importance of morphine detection in urine, the present combined SPE-HPTLC method is suggested as a replacement method for detection of urinary morphine by many reference laboratories.
基金the National Nature Science Foundation of China(No.20675007)
文摘The present study describes guanidinium-based ionic liquids(GBILs) as stationary phases for capillary gas chromatography (CGC) and to the best of our knowledge,no related reports are available up to now.In this study,a hexaalkylguanidinium ionic liquid(DOTMG-NTf;) was synthesized and coated statically onto capillary columns.Selectivity of the stationary phase was evaluated by separating Grob test mixture,test mixture,alcohols mixture,and fatty acid methyl esters mixture,and thermal stability was investigated as well.The present study demonstrates that GBILs as CGC stationary phases exhibit satisfactory selectivity and thermal stability and have a great potential as new candidates for CGC stationary phases.
基金This work was supported by“National Key Research and Development Program of China”(Project No.2018YFC1603400)Science and Technology Program of Hebei Province(Project No.19225503D).
文摘The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples were extracted with 0.2%formic acid acetonitrile solution,purified by on-line SPE device with HLB column,then separated by XBridge C18 column,using 0.1%formic acid solution and acetonitrile as the mobile phase.Mass spectrometric data was acquired under multiple reaction monitoring(MRM)mode using positive ionization electrospray.Internal standard method was used in the quantification,good linear relationship was got in range of 0.1–100 ng/mL and correlation coefficient was higher than 0.9990.The limits of detection were in the range of 0.125–2.00g/kg and the limits of quantitation were in the range of 0.250–5.00g/kg.Recoveries of the method were in range of 78.3%–99.3%,relative standard deviation were lower than 10%.The method was simple,sensitivity,and could be used for routine supervision and analysis of fifteen sulfonamides in pork and fish.
基金the National Nature Science Foundation of China(No.20675007).
文摘One chloride-terminated ionic liquid(CTIL) and two hydroxyl-terminated ionic liquids(HTILs) were synthesized and used as stationary phases for capillary gas chromatography(CGC).Molecular interactions of these stationary phases were evaluated by Abraham solvation parameter model,indicating that the CTIL exhibits remarkably strong H-bond basicity and the HTILs possess both H-bond basicity and acidity.The molecular interactions were further confirmed by separation of a complex mixture consisting of ketones,aldehydes,esters,alcohols and aromatic compounds.It was found that the obtained solvation parameters correlate well with the chromatographic performances of the analytes in terms of elution order and resolution.The well correlated relationship between the solvation parameters and the selectivity of the CTIL and HTILs stationary phases is quite helpful in predicting and understanding the retention behaviors of different types of analytes on these stationary phases.
文摘To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated firstly,and the expanded uncertainty was calculated finally.The results show that when MC-LR concentration in the water samples was 0.50 μg/L,the expanded uncertainty was 0.00628 μg/L(k=2).
文摘A new, rapid and efficient reverse phase Liquid Chromatography (RP-LC) method was developed for determination of Gibberellin A4 (GA4) in samples of flower stalk of Dasylirion cedrosanum and vegetative tissue of Epithelantha micromeris. Purification of GA4 was carried out by solid phase extraction (SPE), in Epithelantha micromeris. In the chromatography method was obtaining a retention time of 2.1 min, using Hypersil GOLD C-18 column (100 × 4.6 mm dim and size particle 5 μ), mobile phase 50/50 acetonitrile/water and a flow 1.0 ml/min. Detection was carried out by a UV detector set at 205 nm, and a quantization limit of 0.4 mg/L. The obtained correlation coefficient was 0.995.
文摘Based on the intersection point rule of the retention value and normal boiling point of homologues in reversed-phase high-performance liquid chromatography(RPLC), the intersection point rule of the retention value of homologues and mobile phase composition has been derived, and was testified by a lot of experimental data from the literature. With this newly proposed equation, we can use the retention value of the compound in one mobile phase composition to predict its retention value in any other mobile phase composition. For fourteen groups of homologues in five mobile phase compositions on five Kinds of columns, the overall average absolute error of 721 data sets is 2.8%.
基金Supported by the Science and Technology Plan of Liaoning Province, China(No.2006226002)the Project of the Doctor Fund of Hebei University of Science and Technology, China(No.005121)
文摘An efficient preparative method was successfully developed for isolation and purification of unstable components from medicinal plant extracts, using a combined method of preparative high performance liquid chro-matography(HPLC) and solid-phase extraction(SPE). The aim of this study was to obtain an effective method with high preparative efficiency and importantly to avoid the transformation of unstable compounds. The preparative HPLC system was based on an LC/MS controlled four-channel autopurification system. The SPE method was performed with a C18 packing material to trap the target compounds and to remove the acidic additive derived from the mobile phase. Using this method, the unstable iridoid glucosides(IGs) as model compounds were successfully isolated and purified from the extract of Hedyotis diffusa Willd. Six IGs(including one new minor IG) and one nucleotide compound were simultaneously obtained, each with a purity of 91% as determined by HPLC. The structures of the isolated compounds were identified by UPLC/Q-TOF MS, UV, 1D and/or 2D NMR. It was demonstrated that the combination of preparative HPLC with SPE is a versatile tool for preparative purification of unstable compounds from complex natural products.
文摘A new reversed-phase high performance liquid chromatography method was developed to quantitate the activity of xanthine oxidase involved in milk fat globule membrane with xanthine as the substrate and the separation of product (uric acid). The increment of uric acid in the reaction system was used to calculate the total activity of XO. The optimized assay conditions, linearity of detection, recovery of uric acid and chromatogram were developed in text, indicating this method is simple, rapid and efficient. It is an alternative potential method for the determination of the activity of XO in milk.
文摘A rapid, fast and precise method has been developed and validated for the simultaneous determination of amlodipine with H1-receptor antagonists (cetirizine, fexofenadine, and buclizine) from dosage forms. The chromatography was performed on a Purospher? Star, C18 (5 mm, 250 × 4.6 mm) column using acetonitrile: buffer (0.01 mM) (40:60, v/v, pH adjusted to 3.0), as a mobile phase. The mobile phase was pumped at a flow rate of 1.0 mL·min-1 and UV detection was performed at 240 nm. The method was validated for linearity, accuracy, precision and specificity. The method was applied to study the interaction between amlodipine and H1-receptor antagonists. These interactions were carried out in simulated gastric juice (pH 1), simulated full stomach (pH 4), blood pH (pH 7.4) and simulating GI (pH 9). The interacting drugs were heated at 37℃ with intermit-tent shaking and the samples were withdrawn every thirty minutes for three hours and drug contents were analyzed by RP-HPLC techniques. In most cases the in vitro availability of amlodipine was decreased. It was observed that the change in in vitro availability was pH dependent.
文摘A new type of HPLC stationary phase containing thymine derivative was successfully prepared.It was found to give selective separation of nucleic acid bases and several purine derivatives,such as caffeine and theophylline.The retention behaviour and elution order of the solutes were interpreted in terms of molecular structure.
基金This research was supported by Special Research Fund for Young Doctors of Qiqihar Medical University(QMSI2020B-03,hosted by Wenjing Li).
文摘A low cost,rapid and sensitive preparation method of silica gel supported ionic liquid(SGSIL)combined with matrix solid phase dispersion(MSPD)followed by high performance liquid chromatography(HPLC)with ultraviolet detection(UV)is proposed,and it was applied to determine the seven active compounds in Salvia Miltiorrhiza herb.SGSIL and ionic liquid[BMIM]BF4 were used as the adsorbent and the green elution reagent in the MSPD procedure.Several extraction conditions including type of filler and elution solvent,the volume of elution solvent,material liquid ratio were optimized.Under the optimum conditions,the SGSIL-MSPD-HPLC method showed a low limit of detection(LOD,S/N=3)of 0.0122-0.8788μg/mL for standard solution,limit of quantification(LOQ,S/N=10)of 0.0406-2.9292μg/mL for standard solution,wide linear range from 1.56 to 2000μg/mL for all compounds for standard solution,correlation coefficients(r)of more than 0.9990,acceptable reproducibility(relative standard deviations,RSDs<3.54%),and precision of RSDs<3.36%for intra-day,RSDs<3.50%for inter-day.The satisfactory recoveries ranged from 96.4 to 102.5,with RSDs less than 3.45%.The developed SGSIL-MSPD method is easier and more suitable for the determination of the seven active compounds in Salvia Miltiorrhiza herb than the traditional ultrasonic extraction.It was an effective and efficient method for the extraction and quantification of the seven active compounds in traditional Chinese herbal samples.
基金Supported by the Key Science and Technology Program of Shaanxi Province,China(No.2015SF146).
文摘AIM:To determine moxonidine in aqueous humor and iris-ciliary body by reversed-phase high performance liquid chromatography(RP-HPLC),and to evaluate the retinal neuroprotective effect after topical administration with moxonidine in a high intraocular pressure(IOP)model.METHODS:The eyes of albino rabbits were administered topically and ipsilaterally with 0.2%moxonidine.A RPHPLC method was employed for the identification and quantification of moxonidine between 2 and 480 min,which presented in the aqueous humor and iris-ciliary body.Flash electroretinography(F-ERG)amplitude and superoxide dismutase(SOD)level were measured between day 1 and day 15 after topical administration with moxonidine in a rabbit model of high IOP.Histological and ultrastructural observation underwent to analyze the changes of retinal morphology,the inner retinal layers(IRL)thickness,and retinal ganglion cell(RGC)counting.RESULTS:Moxonidine was detectable between 2 and 480 min after administration,and the peak concentration developed both in the two tissues at 30 min,0.51μg/m Lin aqueous humor and 1.03μg/g in iris-ciliary body.In comparison to control,F-ERG b-wave amplitude in moxonidine eyes were significantly differences between day 3 and day 15(P<0.01)in the high IOP model;SOD levels were significantly higher at all time-points(P<0.01)with a maximum level of 20.29 U/mgprot at day 15;and RGCs were significantly higher(P<0.05).CONCLUSION:Moxonidine is a viable neuroprotective agent with application to high IOP model.All layers of retina,including RGC layer,retinal nerve fiber layer and INL,are more preserved after moxonidine administration.SOD plays a neuroprotective role in ocular hypertension-mediated RGC death.
基金funded by the grants from the China Natural Science Foundation ( 30671208 and 40773062)Key Project of Guangdong Natural Science Foundation ( 07117909)Science and Technology Planning Project of Guangdong Province( 2005B20801002 and 2006B20601003)
文摘[Objective] To develop a solid phase extraction-high performance liquid chromatography-fluorescence method for determination of quin- olone antibiotics in water. [ Metbod] The standard curves of four quinolones (norfloxacin, ciprofloxacin, Iomefloxacin and enrofloxacin) were pre- pared. The detection limit in water and recovery were determined. The water samples collected from different areas, river and tap water were trea- ted using solid-phese extraction method and analyzed by high performance liquid chromatography. Then the concentration of quinolones antibiotics was determined by fluorescence method. [ Result] The detection limit of quinolone antibiotics in water was 0.083 -0.248 μg/L, and their recovery was 63.7% -134.1%. The four quinolone antibiotics at different levels were detected in various water samples, and the total concentration of quin- olone antibiotics was 0.045 -3.969 μg/L. The total concentration of quinolone antibiotics was higher in the water samples collected from rivers in Shenzhen area than in the sewage samples. The four quinolone antibiotics could be detected in all tap water samples. [ CoaduLsion ] The solid phase extraction-high performance liquid chromatography-fluorescence method is feasible and effective to detect quinolones in water. In addition, this method needs low cost and can meet requirements of daily monitorina and analysis.
文摘Titania microspheres were synthesized using hydrothermal methods to exploit a new liquid chromatography stationary phase. The prepared titania microspheres were approximately 7 μm in diameter, and the particle size distribution was relatively narrow and uniform. Furthermore, the average specific surface area was 276.0 m2·g·1, the average pore volume was approximately 0.25 mL·g·1, and the pore diameter was approximately 35.9 nm for sintering titania microspheres. These parameters indicate that the titania microspheres prepared for this study have excellent surface properties for chromatography. Additionally, columns filled with the titania microspheres were able to separate basic compounds, including benzene, nitrobenzene and o-nitroanisole. It could be proposed that the titania microspheres prepared for this study would be a promising stationary phase for liquid chromatography.
文摘The applicability of hollow fiber liquid-phase microextraction (HF-LPME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was evaluated for the extraction and determination of tamoxifen (TAM) in biological fluids including human urine and plasma. The drug was extracted from a 15 mL aqueous sample (source phase;SP) into an organic phase impregnated in the pores of the hollow fiber (membrane phase;MP) followed by the back-extraction into a second aqueous solution (receiving phase;RP) located in the lumen of the hollow fiber. The effects of several factors such as the nature of organic solvent, compositions of SP and RP solutions, extraction time, ionic strength and stirring rate on the extraction efficiency were examined and optimized. An enrichment factor of 360 along with substantial sample clean up was obtained under the optimized conditions. The calibration curve showed linearity in the range of 1 - 500 ng?mL–1 and the limit of detection was found to be 0.5 ng?mL–1 in aqueous medium. A reasonable relative recovery (≥89%) and satisfactory intra-assay (3.7% - 4.2%, n = 3) and inter-assay (7.5% - 7.8%, n = 3) precision illustrated good performance of the analytical procedure in spiked human urine and plasma samples.
基金Supported by grants of the National Institute of General Medical Sciences,National Institutes of Health(GM-48364),and the Materials Sciences and Engineering Division of the U.S.Department of Energy(DE-AC02-05CH11231).
文摘Modern porous monoliths have been conceived as a new class of stationary phases for high performance liquid chromatography(HPLC) in classical columns in the early 1990s and later extended to the capillary format.These monolithic materials are prepared using simple processes carried out in an external mold(inorganic monoliths) or within the confines of the column(organic monoliths and all capillary columns).These methods afford macroporous materials with large through-pores that enable applications in a rapid flow-through mode.Since all the mobile phase must flow through the monolith,the convection considerably accelerates mass transport within the monolithic separation medium and improves the separations.As a result,the monolithic columns perform well even at very high flow rates.The applications of monolithic capillary columns are demonstrated on numerous separations in the HPLC mode.
文摘A rapid, sensitive and specific ultra-high-performance liquid chromatography tandem mass spectrometry (UPLC-MS) method was developed for the analysis of tetracycline antibiotics, including tetracycline (TC), oxytetracycline (OTC), chlortetracycline (CTC) and their 4-epimers (4-epiTCs) in agricultural soil fertilized with swine manure. Soil samples were extracted and cleaned-up with 10 mL EDTA-McIlvaine buffer solution (pH 4.0), then cleaned-up and pre-concentrated using the Oasis MAX cartridge and then eluted with 1 mL solution by mixing formic acid, methanol and water at a ratio of 2:15:83 (v/v/v). The purified samples were separated by an ACQUITY UPLC BEH C18 column using acetonitrile and water containing 0.1% formic acid mobile phase and detected by a single quadrupole MS. The limits of detection for the soil extraction method (LODsoil) ranged from 0.6-2.5 lag kg-~ with recoveries from 23.3-159.2%. Finally, the method was applied to an agricultural field in an area with intensive pig-fattening farming. Tetracyclines were detected in soil from 2.8 to 42.4 μg kg-1 soil. These results demonstrate that soil from swine farms can become severely contaminated with tetracycline antibiotics and their metabolites.
基金the National Natural Science Foundation of China for the funding(No.20675007)
文摘A new ionic liquids grafted polysiloxane used as stationary phase for capillary gas chromatography (CGC) is described. The stationary phase of 1-vinyl-3-hexylimidazolium hexafluorophosphate anchored to polysiloxane (PMHS-[VHIm][PF6]) was synthe- sized, characterized and coated onto capillary columns by static coating. The results show that the present stationary phase exhibits a very good chromatographic resolution and selectivity for Grob test mixture and alcohols with baseline resolution and symmetry peaks. The present work suggests that novel stationary phase has a great potential for further development and application. 2009 Mei Ling Qi. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.
基金the National Nature Science Foundation of China(No.20675007)
文摘A guanidinium ionic liquid,N,N,N',N'-tetrahexyl-N",N"-dimethylguanidinium bis(trifluoromethane)sulfonylimide(THDMGNTf2), was synthesized and used as stationary phase for capillary gas chromatography.In comparison with imidazolium ionic liquid stationary phase,the present new stationary phase exhibits quite different selectivity and behaves more like a low polar stationary phase.The guanidinium ionic liquid of THDMG-NTf2 exhibited better separation of Grab test mixture than imidazolium ionic liquid of 1-octyl-3-butylimidazolium bis(trifluoromethane)sulfonylimide(OBIM-NTf2).Solvation parameter model was also used to evaluate the selectivity of THDMG-NTf2.Additionally,essential oil of Magnolia biondii Pamp was analyzed to further evaluate the selectivity of THDMG-NTf2 for a sample of complicated components.Satisfactory separation of the essential oil was achieved on a THDMG-NTf2 column(10 m) while using a commercial column(30 m) as reference.The present study shows that the guanidinium ionic liquid possesses novel chromatographic selectivity and has great potential for wide applications.