Mathematical physics equations are often utilized to describe physical phenomena in various fields of science and engineering.One such equation is the Fourier equation,which is a commonly used and effective method for...Mathematical physics equations are often utilized to describe physical phenomena in various fields of science and engineering.One such equation is the Fourier equation,which is a commonly used and effective method for evaluating the effectiveness of temperature control measures for mass concrete.One important measure for temperature control in mass concrete is the use of cooling water pipes.However,the mismatch of grids between large-scale concrete models and small-scale cooling pipe models can result in a significant waste of calculation time when using the finite element method.Moreover,the temperature of the water in the cooling pipe needs to be iteratively calculated during the thermal transfer process.The substructure method can effectively solve this problem,and it has been validated by scholars.The Abaqus/Python secondary development technology provides engineers with enough flexibility to combine the substructure method with an iteration algorithm,which enables the creation of a parametric modeling calculation for cooling water pipes.This paper proposes such a method,which involves iterating the water pipe boundary and establishing the water pipe unit substructure to numerically simulate the concrete temperature field that contains a cooling water pipe.To verify the feasibility and accuracy of the proposed method,two classic numerical examples were analyzed.The results showed that this method has good applicability in cooling pipe calculations.When the value of the iteration parameterαis 0.4,the boundary temperature of the cooling water pipes can meet the accuracy requirements after 4∼5 iterations,effectively improving the computational efficiency.Overall,this approach provides a useful tool for engineers to analyze the temperature control measures accurately and efficiently for mass concrete,such as cooling water pipes,using Abaqus/Python secondary development.展开更多
In recent years,water collecting systems,with the associated advantages of energy saving and noise reduction,have become the foundation for the development of a scheme to optimize the structure of cooling towers.To ex...In recent years,water collecting systems,with the associated advantages of energy saving and noise reduction,have become the foundation for the development of a scheme to optimize the structure of cooling towers.To explore the feasibility of this approach for mechanical draft cooling towers,a small-scale experimental device has been built to study the resistance and splash performances of three U-type water collecting devices(WCDs)for different water flow rates and wind speeds.The experimental results show that within the considered ranges of wind speed and water flow rate,the pressure drop of the different WCDs can vary significantly.The resistance and local splash performances can also be remarkably different.Some recommendations about the most suitable system are provided.Moreover,a regression analysis of the experimental data is conducted,and the resulting fitting formulas for resistance and splash performance of WCD are reported.展开更多
Aiming at reducing the difficulty of cooling the interior of high-density motors,this study proposed the placement of a water cold plate cooling structure between the axial laminations of the motor stator.The effect o...Aiming at reducing the difficulty of cooling the interior of high-density motors,this study proposed the placement of a water cold plate cooling structure between the axial laminations of the motor stator.The effect of the cooling water flow,thickness of the plate,and motor loss density on the cooling effect of the water cold plate were studied.To compare the cooling performance of water cold plate and outer spiral water jacket cooling structures,a high-speed permanent magnet motor with a high loss density was used to establish two motor models with the two cooling structures.Consequently,the cooling effects of the two models were analyzed using the finite element method under the same loss density,coolant flow,and main dimensions.The results were as follows.(1)The maximum and average temperatures of the water cold plate structure were reduced by 25.5%and 30.5%,respectively,compared to that of the outer spiral water jacket motor;(2)Compared with the outer spiral water jacket structure,the water cold plate structure can reduce the overall mass and volume of the motor.Considering a 100 kW high-speed permanent magnet motor as an example,a water cold plate cooling system was designed,and the temperature distribution is analyzed,with the result indicating that the cooling structure satisfied the cooling requirements of the high loss density motor.展开更多
The corrosion inhibition performance of co-immobilized lysozyme and lipase was investigated in a recirculating cooling water system. Four methods were carried out in co-immobilization, and the operating parameters wer...The corrosion inhibition performance of co-immobilized lysozyme and lipase was investigated in a recirculating cooling water system. Four methods were carried out in co-immobilization, and the operating parameters were optimized by using the respond surface methodology(RSM). The corrosion inhibition performance of co-immobilized lipase and lysozyme was evaluated by weight loss measurements and electrochemical measurements. The results revealed that the optimal co-immobilization method should be the sequential immobilization of lysozyme and then lipase. The inhibition efficiency was 86.10% under the optimal co-immobilized conditions. Electrochemical data showed that co-immobilized lysozyme and lipase was a mixed-type inhibitor and the corrosion inhibition efficiency was 81%.展开更多
The influence of temperature, chloride ions and sulfide ions on the anticorrosion behavior of 316L stainless steel in simulated cooling water was studied by electrochemical impedance spectroscopy and anodic polarizati...The influence of temperature, chloride ions and sulfide ions on the anticorrosion behavior of 316L stainless steel in simulated cooling water was studied by electrochemical impedance spectroscopy and anodic polarization curves. The results show that the film resistance increases with the solution temperature but decreases after 8 days’ immersion, which indicates that the film formed at higher temperature has inferior anticorrosion behavior; Chloride ions and sulfide ions have remarkable effects on the electrochemical property of 316L stainless steel in simulated cooling water and the pitting potential declines with the concentration of chloride ions; the passivation current has no obvious effect; the rise of the concentration of sulfide ions obviously increases the passivation current, but the pitting potential changes little, which indicates that the two types of ions may have different effects on destructing passive film of stainless steel. The critical concentration of chloride ions causing anodic potential curve’s change in simulated cooling water is 250 mg/L for 316 L stainless. The effect of sulfide ions on the corrosion resistance behavior of stainless steel is increasing the passivation current density Ip. The addition of 6 mg/L sulfide ions to the solution makes Ip of 316 L increase by 0.5 times.展开更多
A water cooling treatment was applied in the coal-based reduction of high-chromium vanadium and titanium (V-Ti-Cr) iron ore from the Hongge region of Panzhihua, China. Its effects on the metallization ratio (η), ...A water cooling treatment was applied in the coal-based reduction of high-chromium vanadium and titanium (V-Ti-Cr) iron ore from the Hongge region of Panzhihua, China. Its effects on the metallization ratio (η), S removal ratio (Rs), and P removal ratio (Rp) were studied and analyzed on the basis of chemical composition determined via inductively coupled plasma optical emission spectroscopy. The metallic iron particle size and the element distribution of Fe, V, Cr, and Ti in a reduced briquette after water cooling treatment at 1350℃ were determined and observed via scanning electron microscopy. The results show that the water cooling treatment improved the η, Rs, and Rp in the coal-based reduction of V-Ti-Cr iron ore compared to those obtained with a furnace cooling treatment. Meanwhile, the particle size of metallic iron obtained via the water cooling treatment was smaller than that of metallic iron obtained via the furnace cooling treatment; however, the particle size reached 70 μm at 1350℃, which is substantially larger than the minimum particle size required (20 μm) for magnetic separation. Therefore, the water cooling treatment described in this work is a good method for improving the quality of metallic iron in coal-based reduction and it could be applied in the coal-based reduction of V-Ti-Cr iron ore followed by magnetic separation.展开更多
The controlled runout table cooling is essential in determining the final mechanical properties and flatness of steel strip.The heat of a hot steel strip is mainly extracted by cooling water during runout.In order to ...The controlled runout table cooling is essential in determining the final mechanical properties and flatness of steel strip.The heat of a hot steel strip is mainly extracted by cooling water during runout.In order to study the heat transfer by water jet impingement boiling during runout,apilot facility was constructed at the University of British Columbia.On this pilot facility,the water jet impingement tests were carried out under various cooling conditions to investigate the effect of processing parameters,such as cooling water temperature,water jet impingement velocity,initial strip temperature,water flow rate,water nozzle diameter and array of water nozzles,on the heat transfer of heated strip.The results obtained contribute to the optimization of cooling water during runout.展开更多
AZ31 Mg alloy with heterogeneous bimodal grain structure(smaller grain size of 5-20µm and coarser grain size of 100-200µm)was subjected to accumulated extrusion bonding(AEB)at 250℃combined with two-stage ar...AZ31 Mg alloy with heterogeneous bimodal grain structure(smaller grain size of 5-20µm and coarser grain size of 100-200µm)was subjected to accumulated extrusion bonding(AEB)at 250℃combined with two-stage artificial cooling in this work,viz.local water cooling and artificial cooling.The microstructure developed consecutively as a result of discontinuous dynamic recrystallization(DDRX)for the AEBed samples.{10-12}tensile twinning also played an important role for the AEB with local water cooling at the initial extrusion stage in the container.Local water cooling could further reduce the DRXed grain size to~2.1µm comparing that without water cooling.And the grain growth rate was reduced by artificial cooling out of extrusion die.Under the combination of two-stage cooling,the fine DRXed grains at sizing band were almost retained with average grain size of~2.3µm after the sheet out of extrusion die,and the unDRXed grains with high residual dislocation density accumulation were also reserved.The tensile tests results indicated that a good strength-ductility balance with a high ultimate tensile strength(319 MPa vs.412 MPa)and fracture elongation(19.9%vs.30.3%)were obtained.The strength enhancement was mainly owing to the grain refinement and local residual plastic strain reserved by the artificial cooling.The excellent ductility originated from fine DRXed microstructure and ED-tilt double peak texture.展开更多
Recent research on deterministic methods for circulating cooling water systems optimization has been well developed. However, the actual operating conditions of the system are mostly variable, so the system obtained u...Recent research on deterministic methods for circulating cooling water systems optimization has been well developed. However, the actual operating conditions of the system are mostly variable, so the system obtained under deterministic conditions may not be stable and economical. This paper studies the optimization of circulating cooling water systems under uncertain circumstance. To improve the reliability of the system and reduce the water and energy consumption, the influence of different uncertain parameters is taken into consideration. The chance constrained programming method is used to build a model under uncertain conditions, where the confidence level indicates the degree of constraint violation. Probability distribution functions are used to describe the form of uncertain parameters. The objective is to minimize the total cost and obtain the optimal cooling network configuration simultaneously.An algorithm based on Monte Carlo method is proposed, and GAMS software is used to solve the mixed integer nonlinear programming model. A case is optimized to verify the validity of the model. Compared with the deterministic optimization method, the results show that when considering the different types of uncertain parameters, a system with better economy and reliability can be obtained(total cost can be reduced at least 2%).展开更多
We conducted a transient experimental investigation of steam–water direct contact condensation in the absence of noncondensible gas in a laboratory-scale column with the inner diameter of 325 mm and the height of 104...We conducted a transient experimental investigation of steam–water direct contact condensation in the absence of noncondensible gas in a laboratory-scale column with the inner diameter of 325 mm and the height of 1045 mm. We applied a new analysis method for the steam state equation to analyze the molar quantity change in steam over the course of the experiment and determined the transient steam variation. We also investigated the influence of flow rates and temperatures ofcooling water on the efficiency ofsteam condensation. Our experimental results show that appropriate increasing of the cooling water flow rate can significantly accelerate the steam condensation. We achieved a rapid increase in the total volumetric heat transfer coefficient by increasing the flow rate of cooling water, which indicated a higher thermal convection between the steam and the cooling water with higher flow rates. We found that the temperature ofcooling water did not play an important role on steam condensation. This method was confirmed to be effective for rapid recovering ofsteam.展开更多
MIC is one of the main problems of circulating cooling water system. The direct economic loss by MIC is about 300 to 500 billion dollars. It is good to understand MIC in order to control MIC. Source and species of mic...MIC is one of the main problems of circulating cooling water system. The direct economic loss by MIC is about 300 to 500 billion dollars. It is good to understand MIC in order to control MIC. Source and species of microorganisms was introduced firstly. There are three kinds of microorganisms in the system, including bacteria, fungi and algae. Species of these microorganisms are shown in the paper. Then, mechanisms of MIC are analysed. Although there is no universal mechanism of MIC, MIC is still mainly an electrochemical corrosion in nature. Meanwhile, the mechanisms on SRB and iron bacteria are introduced in details. At last, several methods of microorganisms control are put forward in the paper.展开更多
A series of orthogonal array experiments were conducted using carbon source, ammonia nitrogen and total phosphorus (TP) as major influencing factors to investigate the effects of nutrients on biofouling formation an...A series of orthogonal array experiments were conducted using carbon source, ammonia nitrogen and total phosphorus (TP) as major influencing factors to investigate the effects of nutrients on biofouling formation and preponderant bacteria diversity in the recirculatiug cooling water system. Carbon source was demonstrated to be the most significant determinant affecting the biofouling formation. A minimum biofouling outcome was obtained when BOD2, NHa+-N and TP were 25, 10, and 1 mg/L, respectively. Then the preponderant bacteria strains in biofouling mass under two typical culture conditions (negative and favorable) were identified applying both traditional biochemical methods and further molecular biology technology with phylogenetic affiliation analysis, which indicated that Enterobacteriaceae Enterobacter, Micrococcaceae Staphylococcus, Bacillaceae Bacillus, Enterobacteriaceae Proteus, Neisseriaceae Neisseria and Pseudomonadaceae Pseudomonas were dominant under negative condition, while Enterobacteriaceae Klebsiella, Enterobacteriaceae Enterobacter and Microbacterium - under favorable one.展开更多
In order to solve the problems including pipe corrosion, scaling and microbial growth, which severely threat safe op-eration of circulating cooling water system, this paper proposes ion exchange softening and alkaliza...In order to solve the problems including pipe corrosion, scaling and microbial growth, which severely threat safe op-eration of circulating cooling water system, this paper proposes ion exchange softening and alkalization process to solve these problems and carries out a series of studies to study the feasibility of ion exchange softening and alkaliza-tion process in the simulation process of circulating cooling water system. The studies include product water quality of ion exchange softening and alkalization process, effect on the performance of carbon steel and brass, and the inhibition that suppresses microbial growth. The results indicate that ion exchange softening and alkalization process is feasible to prevent the circulating cooling water system from scaling, pipe corrosion, and microbial growth without any other chemicals. Thus circulating cooling water system can achieve zerodischarge of wastewater.展开更多
The STAR-CCM+software is used to investigate the flow inside a cooling water jacket of an in-line six-cylinder diesel engine.The results show that the average flow velocity of the cooling water inside the jacket is 1....The STAR-CCM+software is used to investigate the flow inside a cooling water jacket of an in-line six-cylinder diesel engine.The results show that the average flow velocity of the cooling water inside the jacket is 1.669 m/s while the flow velocity distribution is not uniform for each cylinder.Moreover,the fluid velocity in proximity to the cylinder head is too low,thereby affecting the cooling performances of the water jacket.Two corresponding structural optimization schemes are proposed to mitigate this issue and the post-optimization performances of the water jacket are discussed in detail.展开更多
An exhaust heat recovery generator is proposed to be integrated with conventional gas-fired triple-effect LiBr/water absorption cooling cycles to improve system energy efficiency. As a case study, simulation of the no...An exhaust heat recovery generator is proposed to be integrated with conventional gas-fired triple-effect LiBr/water absorption cooling cycles to improve system energy efficiency. As a case study, simulation of the novel cycle based on promising parallel flow with cooling capacity of 1 150 kW is carried out under various heat recovery generator vapor production ratios ranging from 0 to 3.5%. The life cycle saving economic analysis, for which the annual gas conservation is estimated with Bin method, is employed to prove the worthiness of extra expenditure. Results show that the optimum gas saving revenue is obtained at 2.8% heat recovery generator vapor production ratio with 42 kW exhaust heat recovered, and the system energy efficiency is improved from 1.78 to 1.83. The initial investment of exchanger can be paid back within 7 years and 9 000 CNY of gas saving revenue will be achieved over the 15-year life cycle of the machine. This technology can be easily implemented and present desirable economic effects, which is feasible to the development of triple-effect absorption cycles.展开更多
Gas turbine (GT) power plants operating in arid climates suffer a decrease in output power during the hot summer months because of the high specific volume of air drawn by the compressor. Cooling the air intake to the...Gas turbine (GT) power plants operating in arid climates suffer a decrease in output power during the hot summer months because of the high specific volume of air drawn by the compressor. Cooling the air intake to the compressor has been widely used to mitigate this shortcoming. Energy and exergy analysis of a GT Brayton cycle coupled to a refrigeration air cooling unit shows a promise for increasing the output power with a little decrease in thermal efficiency. A thermo-economics algorithm is developed to estimate the economic feasibility of the cooling system. The analysis is applied to an open cycle, HITACHI-FS7001B GT plant at the industrial city of Yanbu (Latitude 24o 05” N and longitude 38o E) by the Red Sea in the Kingdom of Saudi Arabia. Result show that the enhancement in output power depends on the degree of chilling the air intake to the compressor (a 12 - 22 K decrease is achieved). For this case study, maximum power gain ratio (PGR) is 15.46% (average of 12.25%), at an insignificant decrease in thermal efficiency. The second law analysis show that the exergetic power gain ratio drops to an average 8.5%. The cost of adding the air cooling system is also investigated and a cost function is derived that incorporates time-dependent meteorological data, operation characteristics of the GT and the air intake cooling system and other relevant parameters such as interest rate, lifetime, and operation and maintenance costs. The profit of adding the air cooling system is calculated for different electricity tariff.展开更多
Mesoporous SiO_2 microspheres were synthesized using the sol-gel method and were characterized by TEM, FT-IR and BET techniques. The diameter of the microspheres is about 100—150 nm, and the average mesopore diameter...Mesoporous SiO_2 microspheres were synthesized using the sol-gel method and were characterized by TEM, FT-IR and BET techniques. The diameter of the microspheres is about 100—150 nm, and the average mesopore diameter is 2.55 nm, while the specific surface area is 1 088.9 m2/g. Mesoporous SiO_2 microspheres adsorb glutaraldehyde and immobilize laccase by means of the aldehyde group in glutaral which can react with the amidogen of laccase. The immobilization conditions were optimized at a glutaraldehyde concentration of 0.75%, a crosslinking time of 8 h, a laccase concentration of 0.04 L/L and an immobilization time of 10 h. When diesel leakage concentration was 80 mg/L, the highest corrosion inhibition efficiency of immobilized laccase reached 49.23%, which was slightly lower than the corrosion inhibition efficiency of free laccase(59%). The diesel degradation ratio could reach up to 45%. It has been proved that the immobilized laccase could degrade diesel to inhibit corrosion.展开更多
The embedded water pipe system is often used as a standard cooling technique during the construction of large-scale mass concrete hydrostructures. The prediction of the temperature distribution considering the cooling...The embedded water pipe system is often used as a standard cooling technique during the construction of large-scale mass concrete hydrostructures. The prediction of the temperature distribution considering the cooling effects of embedded pipes plays an essential role in the design of the structure and its cooling system. In this study, the singular boundary method, a semi-analytical meshless technique, was employed to analyze the temperature distribution. A numerical algorithm solved the transient temperature field with consideration of the effects of cooling pipe specification, isolation of heat of hydration, and ambient temperature. Numerical results are verified through comparison with those of the finite element method, demonstrating that the proposed approach is accurate in the simulation of the thermal field in concrete structures with a water cooling pipe.展开更多
At present, the water-cooling simulation of the water-cooled magnetic coupler is based on the water-cooled motor and the hydraulic coupler, which cannot accurately characterize the temperature distribution of the rota...At present, the water-cooling simulation of the water-cooled magnetic coupler is based on the water-cooled motor and the hydraulic coupler, which cannot accurately characterize the temperature distribution of the rotating watercooled coupling of the coupler. Focusing on rotating water cooling radiating, the present paper proposes simulating the water cooling temperature field as well as the flow field through the method of combining fluid-solid coupled heat transfer and MRF(Multiphase Reference Frame). In addition, taking an 800 kW magnetic coupling as an example, the paper optimizes the shape, number, cooling water inlet speed? and so on? of the cooling channel. Considering factors such as the complete machine’s temperature, and drag torque, it is proved that the cooling e ect is best when there are 36 involute curved channels and when the inlet speed is 3 m/s. Further, through experiments, the actual temperature values at six di erent positions when 50 kW and 70 kW thermal losses di er are measured. The measured values agree with the simulation results, proving the correctness of the proposed method. Further, data have been collected during the entire experimental procedure? and the variation in the coupling’s temperature is analyzed in depth, with the objective of laying a foundation for the estimation of the inner temperature rise as well as for the optimization of the structural design.展开更多
On the basis of expounding the corrosion mechanism of the stator hollow copper conductor in the water-cooling generator, methods of preventing corrosion of the stator hollow copper conductor in the wa-ter-cooling gene...On the basis of expounding the corrosion mechanism of the stator hollow copper conductor in the water-cooling generator, methods of preventing corrosion of the stator hollow copper conductor in the wa-ter-cooling generator through adjusting water quality of its cooling water have been proposed. For internal water cooling systems which are airtight, the corrosion of the hollow copper conductor can be prevented through keeping foreign oxygen and carbon dioxide from entering the system, and the amount of oxygen in the internal water can be lowered by blowing high purity nitrogen. For systems not airtight, the corrosion of the hollow copper conductor can be inhibited through lowering the amount of oxygen to some extent by sealing and increasing pH value by processing part of cooling water with bypass small flow sodium-type mix-bed.展开更多
文摘Mathematical physics equations are often utilized to describe physical phenomena in various fields of science and engineering.One such equation is the Fourier equation,which is a commonly used and effective method for evaluating the effectiveness of temperature control measures for mass concrete.One important measure for temperature control in mass concrete is the use of cooling water pipes.However,the mismatch of grids between large-scale concrete models and small-scale cooling pipe models can result in a significant waste of calculation time when using the finite element method.Moreover,the temperature of the water in the cooling pipe needs to be iteratively calculated during the thermal transfer process.The substructure method can effectively solve this problem,and it has been validated by scholars.The Abaqus/Python secondary development technology provides engineers with enough flexibility to combine the substructure method with an iteration algorithm,which enables the creation of a parametric modeling calculation for cooling water pipes.This paper proposes such a method,which involves iterating the water pipe boundary and establishing the water pipe unit substructure to numerically simulate the concrete temperature field that contains a cooling water pipe.To verify the feasibility and accuracy of the proposed method,two classic numerical examples were analyzed.The results showed that this method has good applicability in cooling pipe calculations.When the value of the iteration parameterαis 0.4,the boundary temperature of the cooling water pipes can meet the accuracy requirements after 4∼5 iterations,effectively improving the computational efficiency.Overall,this approach provides a useful tool for engineers to analyze the temperature control measures accurately and efficiently for mass concrete,such as cooling water pipes,using Abaqus/Python secondary development.
基金This work was supported by the Shandong Natural Science Foundation(Grant No.ZR2022ME008)the Shenzhen Science and Technology Program(KCXFZ20201221173409026)+2 种基金the Young Scholars Program of Shandong University(YSPSDU,No.2018WLJH73)the Open Project of State Key Laboratory of Clean Energy Utilization,Zhejiang University(Program No.ZJUCEU2020011)the Shandong Natural Science Foundation(Grant No.ZR2021ME118).
文摘In recent years,water collecting systems,with the associated advantages of energy saving and noise reduction,have become the foundation for the development of a scheme to optimize the structure of cooling towers.To explore the feasibility of this approach for mechanical draft cooling towers,a small-scale experimental device has been built to study the resistance and splash performances of three U-type water collecting devices(WCDs)for different water flow rates and wind speeds.The experimental results show that within the considered ranges of wind speed and water flow rate,the pressure drop of the different WCDs can vary significantly.The resistance and local splash performances can also be remarkably different.Some recommendations about the most suitable system are provided.Moreover,a regression analysis of the experimental data is conducted,and the resulting fitting formulas for resistance and splash performance of WCD are reported.
基金supported by the National Natural Science Foundation of China(51920105011)Natural Science Foundation of Liaoning Province(2021-YQ-09)Liaoning Bai Qian Wan Talents Program,China.
文摘Aiming at reducing the difficulty of cooling the interior of high-density motors,this study proposed the placement of a water cold plate cooling structure between the axial laminations of the motor stator.The effect of the cooling water flow,thickness of the plate,and motor loss density on the cooling effect of the water cold plate were studied.To compare the cooling performance of water cold plate and outer spiral water jacket cooling structures,a high-speed permanent magnet motor with a high loss density was used to establish two motor models with the two cooling structures.Consequently,the cooling effects of the two models were analyzed using the finite element method under the same loss density,coolant flow,and main dimensions.The results were as follows.(1)The maximum and average temperatures of the water cold plate structure were reduced by 25.5%and 30.5%,respectively,compared to that of the outer spiral water jacket motor;(2)Compared with the outer spiral water jacket structure,the water cold plate structure can reduce the overall mass and volume of the motor.Considering a 100 kW high-speed permanent magnet motor as an example,a water cold plate cooling system was designed,and the temperature distribution is analyzed,with the result indicating that the cooling structure satisfied the cooling requirements of the high loss density motor.
基金financially supported by the National Natural Science Foundation of China (project 21077133)the Natural Foundation of Shandong Province and the Top Talent Project of China University of Petroleum (16RC17040003)
文摘The corrosion inhibition performance of co-immobilized lysozyme and lipase was investigated in a recirculating cooling water system. Four methods were carried out in co-immobilization, and the operating parameters were optimized by using the respond surface methodology(RSM). The corrosion inhibition performance of co-immobilized lipase and lysozyme was evaluated by weight loss measurements and electrochemical measurements. The results revealed that the optimal co-immobilization method should be the sequential immobilization of lysozyme and then lipase. The inhibition efficiency was 86.10% under the optimal co-immobilized conditions. Electrochemical data showed that co-immobilized lysozyme and lipase was a mixed-type inhibitor and the corrosion inhibition efficiency was 81%.
文摘The influence of temperature, chloride ions and sulfide ions on the anticorrosion behavior of 316L stainless steel in simulated cooling water was studied by electrochemical impedance spectroscopy and anodic polarization curves. The results show that the film resistance increases with the solution temperature but decreases after 8 days’ immersion, which indicates that the film formed at higher temperature has inferior anticorrosion behavior; Chloride ions and sulfide ions have remarkable effects on the electrochemical property of 316L stainless steel in simulated cooling water and the pitting potential declines with the concentration of chloride ions; the passivation current has no obvious effect; the rise of the concentration of sulfide ions obviously increases the passivation current, but the pitting potential changes little, which indicates that the two types of ions may have different effects on destructing passive film of stainless steel. The critical concentration of chloride ions causing anodic potential curve’s change in simulated cooling water is 250 mg/L for 316 L stainless. The effect of sulfide ions on the corrosion resistance behavior of stainless steel is increasing the passivation current density Ip. The addition of 6 mg/L sulfide ions to the solution makes Ip of 316 L increase by 0.5 times.
基金financially supported by the Programs of the National Natural Science Foundation of China(Nos.51604065,51090384,51674084,51174051,and 51574082)the National Basic Research Program of China(No.2013CB632603)+1 种基金the Fundamental Funds for the Central Universities(Nos.150203003 and 150202001)the National Key Technology Research and development Program(No.2015BAB19B02)
文摘A water cooling treatment was applied in the coal-based reduction of high-chromium vanadium and titanium (V-Ti-Cr) iron ore from the Hongge region of Panzhihua, China. Its effects on the metallization ratio (η), S removal ratio (Rs), and P removal ratio (Rp) were studied and analyzed on the basis of chemical composition determined via inductively coupled plasma optical emission spectroscopy. The metallic iron particle size and the element distribution of Fe, V, Cr, and Ti in a reduced briquette after water cooling treatment at 1350℃ were determined and observed via scanning electron microscopy. The results show that the water cooling treatment improved the η, Rs, and Rp in the coal-based reduction of V-Ti-Cr iron ore compared to those obtained with a furnace cooling treatment. Meanwhile, the particle size of metallic iron obtained via the water cooling treatment was smaller than that of metallic iron obtained via the furnace cooling treatment; however, the particle size reached 70 μm at 1350℃, which is substantially larger than the minimum particle size required (20 μm) for magnetic separation. Therefore, the water cooling treatment described in this work is a good method for improving the quality of metallic iron in coal-based reduction and it could be applied in the coal-based reduction of V-Ti-Cr iron ore followed by magnetic separation.
文摘The controlled runout table cooling is essential in determining the final mechanical properties and flatness of steel strip.The heat of a hot steel strip is mainly extracted by cooling water during runout.In order to study the heat transfer by water jet impingement boiling during runout,apilot facility was constructed at the University of British Columbia.On this pilot facility,the water jet impingement tests were carried out under various cooling conditions to investigate the effect of processing parameters,such as cooling water temperature,water jet impingement velocity,initial strip temperature,water flow rate,water nozzle diameter and array of water nozzles,on the heat transfer of heated strip.The results obtained contribute to the optimization of cooling water during runout.
基金The authors are grateful for the National Natural Science Foundation of China(No.51905366 and U1810122)Yantai high-end talent introduction"Double Hundred Plan"(2021)Key Research and Development Program of Shanxi Province(201903D421076).
文摘AZ31 Mg alloy with heterogeneous bimodal grain structure(smaller grain size of 5-20µm and coarser grain size of 100-200µm)was subjected to accumulated extrusion bonding(AEB)at 250℃combined with two-stage artificial cooling in this work,viz.local water cooling and artificial cooling.The microstructure developed consecutively as a result of discontinuous dynamic recrystallization(DDRX)for the AEBed samples.{10-12}tensile twinning also played an important role for the AEB with local water cooling at the initial extrusion stage in the container.Local water cooling could further reduce the DRXed grain size to~2.1µm comparing that without water cooling.And the grain growth rate was reduced by artificial cooling out of extrusion die.Under the combination of two-stage cooling,the fine DRXed grains at sizing band were almost retained with average grain size of~2.3µm after the sheet out of extrusion die,and the unDRXed grains with high residual dislocation density accumulation were also reserved.The tensile tests results indicated that a good strength-ductility balance with a high ultimate tensile strength(319 MPa vs.412 MPa)and fracture elongation(19.9%vs.30.3%)were obtained.The strength enhancement was mainly owing to the grain refinement and local residual plastic strain reserved by the artificial cooling.The excellent ductility originated from fine DRXed microstructure and ED-tilt double peak texture.
基金Financial support from the National Natural Science Foundation of China (22022816, 22078358)。
文摘Recent research on deterministic methods for circulating cooling water systems optimization has been well developed. However, the actual operating conditions of the system are mostly variable, so the system obtained under deterministic conditions may not be stable and economical. This paper studies the optimization of circulating cooling water systems under uncertain circumstance. To improve the reliability of the system and reduce the water and energy consumption, the influence of different uncertain parameters is taken into consideration. The chance constrained programming method is used to build a model under uncertain conditions, where the confidence level indicates the degree of constraint violation. Probability distribution functions are used to describe the form of uncertain parameters. The objective is to minimize the total cost and obtain the optimal cooling network configuration simultaneously.An algorithm based on Monte Carlo method is proposed, and GAMS software is used to solve the mixed integer nonlinear programming model. A case is optimized to verify the validity of the model. Compared with the deterministic optimization method, the results show that when considering the different types of uncertain parameters, a system with better economy and reliability can be obtained(total cost can be reduced at least 2%).
文摘We conducted a transient experimental investigation of steam–water direct contact condensation in the absence of noncondensible gas in a laboratory-scale column with the inner diameter of 325 mm and the height of 1045 mm. We applied a new analysis method for the steam state equation to analyze the molar quantity change in steam over the course of the experiment and determined the transient steam variation. We also investigated the influence of flow rates and temperatures ofcooling water on the efficiency ofsteam condensation. Our experimental results show that appropriate increasing of the cooling water flow rate can significantly accelerate the steam condensation. We achieved a rapid increase in the total volumetric heat transfer coefficient by increasing the flow rate of cooling water, which indicated a higher thermal convection between the steam and the cooling water with higher flow rates. We found that the temperature ofcooling water did not play an important role on steam condensation. This method was confirmed to be effective for rapid recovering ofsteam.
文摘MIC is one of the main problems of circulating cooling water system. The direct economic loss by MIC is about 300 to 500 billion dollars. It is good to understand MIC in order to control MIC. Source and species of microorganisms was introduced firstly. There are three kinds of microorganisms in the system, including bacteria, fungi and algae. Species of these microorganisms are shown in the paper. Then, mechanisms of MIC are analysed. Although there is no universal mechanism of MIC, MIC is still mainly an electrochemical corrosion in nature. Meanwhile, the mechanisms on SRB and iron bacteria are introduced in details. At last, several methods of microorganisms control are put forward in the paper.
基金supported by the National Natural Science Foundation of China (No.20707040)the State Key Laboratory of Pollution Control and Resource Reuse Foundation(No. PCRRF08002).
文摘A series of orthogonal array experiments were conducted using carbon source, ammonia nitrogen and total phosphorus (TP) as major influencing factors to investigate the effects of nutrients on biofouling formation and preponderant bacteria diversity in the recirculatiug cooling water system. Carbon source was demonstrated to be the most significant determinant affecting the biofouling formation. A minimum biofouling outcome was obtained when BOD2, NHa+-N and TP were 25, 10, and 1 mg/L, respectively. Then the preponderant bacteria strains in biofouling mass under two typical culture conditions (negative and favorable) were identified applying both traditional biochemical methods and further molecular biology technology with phylogenetic affiliation analysis, which indicated that Enterobacteriaceae Enterobacter, Micrococcaceae Staphylococcus, Bacillaceae Bacillus, Enterobacteriaceae Proteus, Neisseriaceae Neisseria and Pseudomonadaceae Pseudomonas were dominant under negative condition, while Enterobacteriaceae Klebsiella, Enterobacteriaceae Enterobacter and Microbacterium - under favorable one.
文摘In order to solve the problems including pipe corrosion, scaling and microbial growth, which severely threat safe op-eration of circulating cooling water system, this paper proposes ion exchange softening and alkalization process to solve these problems and carries out a series of studies to study the feasibility of ion exchange softening and alkaliza-tion process in the simulation process of circulating cooling water system. The studies include product water quality of ion exchange softening and alkalization process, effect on the performance of carbon steel and brass, and the inhibition that suppresses microbial growth. The results indicate that ion exchange softening and alkalization process is feasible to prevent the circulating cooling water system from scaling, pipe corrosion, and microbial growth without any other chemicals. Thus circulating cooling water system can achieve zerodischarge of wastewater.
文摘The STAR-CCM+software is used to investigate the flow inside a cooling water jacket of an in-line six-cylinder diesel engine.The results show that the average flow velocity of the cooling water inside the jacket is 1.669 m/s while the flow velocity distribution is not uniform for each cylinder.Moreover,the fluid velocity in proximity to the cylinder head is too low,thereby affecting the cooling performances of the water jacket.Two corresponding structural optimization schemes are proposed to mitigate this issue and the post-optimization performances of the water jacket are discussed in detail.
基金Supported by National Natural Science Foundation of China (No. 50376044)
文摘An exhaust heat recovery generator is proposed to be integrated with conventional gas-fired triple-effect LiBr/water absorption cooling cycles to improve system energy efficiency. As a case study, simulation of the novel cycle based on promising parallel flow with cooling capacity of 1 150 kW is carried out under various heat recovery generator vapor production ratios ranging from 0 to 3.5%. The life cycle saving economic analysis, for which the annual gas conservation is estimated with Bin method, is employed to prove the worthiness of extra expenditure. Results show that the optimum gas saving revenue is obtained at 2.8% heat recovery generator vapor production ratio with 42 kW exhaust heat recovered, and the system energy efficiency is improved from 1.78 to 1.83. The initial investment of exchanger can be paid back within 7 years and 9 000 CNY of gas saving revenue will be achieved over the 15-year life cycle of the machine. This technology can be easily implemented and present desirable economic effects, which is feasible to the development of triple-effect absorption cycles.
文摘Gas turbine (GT) power plants operating in arid climates suffer a decrease in output power during the hot summer months because of the high specific volume of air drawn by the compressor. Cooling the air intake to the compressor has been widely used to mitigate this shortcoming. Energy and exergy analysis of a GT Brayton cycle coupled to a refrigeration air cooling unit shows a promise for increasing the output power with a little decrease in thermal efficiency. A thermo-economics algorithm is developed to estimate the economic feasibility of the cooling system. The analysis is applied to an open cycle, HITACHI-FS7001B GT plant at the industrial city of Yanbu (Latitude 24o 05” N and longitude 38o E) by the Red Sea in the Kingdom of Saudi Arabia. Result show that the enhancement in output power depends on the degree of chilling the air intake to the compressor (a 12 - 22 K decrease is achieved). For this case study, maximum power gain ratio (PGR) is 15.46% (average of 12.25%), at an insignificant decrease in thermal efficiency. The second law analysis show that the exergetic power gain ratio drops to an average 8.5%. The cost of adding the air cooling system is also investigated and a cost function is derived that incorporates time-dependent meteorological data, operation characteristics of the GT and the air intake cooling system and other relevant parameters such as interest rate, lifetime, and operation and maintenance costs. The profit of adding the air cooling system is calculated for different electricity tariff.
基金supported by the Foundation for Top Talents Program of China University of Petroleum
文摘Mesoporous SiO_2 microspheres were synthesized using the sol-gel method and were characterized by TEM, FT-IR and BET techniques. The diameter of the microspheres is about 100—150 nm, and the average mesopore diameter is 2.55 nm, while the specific surface area is 1 088.9 m2/g. Mesoporous SiO_2 microspheres adsorb glutaraldehyde and immobilize laccase by means of the aldehyde group in glutaral which can react with the amidogen of laccase. The immobilization conditions were optimized at a glutaraldehyde concentration of 0.75%, a crosslinking time of 8 h, a laccase concentration of 0.04 L/L and an immobilization time of 10 h. When diesel leakage concentration was 80 mg/L, the highest corrosion inhibition efficiency of immobilized laccase reached 49.23%, which was slightly lower than the corrosion inhibition efficiency of free laccase(59%). The diesel degradation ratio could reach up to 45%. It has been proved that the immobilized laccase could degrade diesel to inhibit corrosion.
基金supported by the National Natural Science Foundation of China(Grants No.11572111 and 11372097)the 111 Project(Grant No.B12122)
文摘The embedded water pipe system is often used as a standard cooling technique during the construction of large-scale mass concrete hydrostructures. The prediction of the temperature distribution considering the cooling effects of embedded pipes plays an essential role in the design of the structure and its cooling system. In this study, the singular boundary method, a semi-analytical meshless technique, was employed to analyze the temperature distribution. A numerical algorithm solved the transient temperature field with consideration of the effects of cooling pipe specification, isolation of heat of hydration, and ambient temperature. Numerical results are verified through comparison with those of the finite element method, demonstrating that the proposed approach is accurate in the simulation of the thermal field in concrete structures with a water cooling pipe.
基金Supported by China Coal Science and Technology Group Technology Innovation Fund Major Project(Grand No.2018ZD002)China Coal Science and Technology Group Technology Innovation Fund Youth Project(Grand No.2018-2-QN010)
文摘At present, the water-cooling simulation of the water-cooled magnetic coupler is based on the water-cooled motor and the hydraulic coupler, which cannot accurately characterize the temperature distribution of the rotating watercooled coupling of the coupler. Focusing on rotating water cooling radiating, the present paper proposes simulating the water cooling temperature field as well as the flow field through the method of combining fluid-solid coupled heat transfer and MRF(Multiphase Reference Frame). In addition, taking an 800 kW magnetic coupling as an example, the paper optimizes the shape, number, cooling water inlet speed? and so on? of the cooling channel. Considering factors such as the complete machine’s temperature, and drag torque, it is proved that the cooling e ect is best when there are 36 involute curved channels and when the inlet speed is 3 m/s. Further, through experiments, the actual temperature values at six di erent positions when 50 kW and 70 kW thermal losses di er are measured. The measured values agree with the simulation results, proving the correctness of the proposed method. Further, data have been collected during the entire experimental procedure? and the variation in the coupling’s temperature is analyzed in depth, with the objective of laying a foundation for the estimation of the inner temperature rise as well as for the optimization of the structural design.
文摘On the basis of expounding the corrosion mechanism of the stator hollow copper conductor in the water-cooling generator, methods of preventing corrosion of the stator hollow copper conductor in the wa-ter-cooling generator through adjusting water quality of its cooling water have been proposed. For internal water cooling systems which are airtight, the corrosion of the hollow copper conductor can be prevented through keeping foreign oxygen and carbon dioxide from entering the system, and the amount of oxygen in the internal water can be lowered by blowing high purity nitrogen. For systems not airtight, the corrosion of the hollow copper conductor can be inhibited through lowering the amount of oxygen to some extent by sealing and increasing pH value by processing part of cooling water with bypass small flow sodium-type mix-bed.