Device physics research for submicron and deep submicron space microelectronics devices and integrated circuits will be described in three topics.1.Thin film submicron and deep submicron SOS / CMOS devices and integra...Device physics research for submicron and deep submicron space microelectronics devices and integrated circuits will be described in three topics.1.Thin film submicron and deep submicron SOS / CMOS devices and integrated circuits.2.Deep submicron LDD CMOS devices and integrated circuits.3.C band and Ku band microwave GaAs MESFET and III-V compound hetrojunction HEM T and HBT devices and integrated circuits.展开更多
The tokamak HT-7U project has been funded as a Chinese national project since 1998. The main object of the project is to build a nuclear fusion experimental device with divertor configuration, which is designed by the...The tokamak HT-7U project has been funded as a Chinese national project since 1998. The main object of the project is to build a nuclear fusion experimental device with divertor configuration, which is designed by the Institute of Plasma Physics, the Chinese Academy of Sciences (ASIPP). It is a full superconducting device, consisting of superconducting toroidal field (TF) coils and superconducting poloidal field (PF) coil. During the operation of the device, the operational parameter of device should be checked by technical diagnosis. This paper describes the design of circuit for checldng short between every two parts of the HT7U device. The main contents of design include circuit of data acquisition and data processing of computer.展开更多
The concept of Internet of Things(IoT)was first proposed by MIT Prof.Kevin Ash-ton in 1999.The implementation of IoT was mainly through RFID in its early time.With advanced technology and manufacture,diverse impleme...The concept of Internet of Things(IoT)was first proposed by MIT Prof.Kevin Ash-ton in 1999.The implementation of IoT was mainly through RFID in its early time.With advanced technology and manufacture,diverse implementation forms of IoT are becoming possible.Wearable devices,as an essential branch of IoT,will have broad application prospects in health monitoring and intelligent healthcare.展开更多
ZnO whiskers observation on the surface of SnZn/Cu solder joints in concentrator silicon solar cells solder layer is reported. In the experiment,SnZn/Cu samples are left in laboratory after reflow soldering for two ye...ZnO whiskers observation on the surface of SnZn/Cu solder joints in concentrator silicon solar cells solder layer is reported. In the experiment,SnZn/Cu samples are left in laboratory after reflow soldering for two years before an examination by SEM,then ZnO whiskers can be observed obviously,which grows out from the rich-Zn phase of the samples and causes electrical short circuit in the electronics appliances,which demonstrates that the SnZn solder shows a risk for the short circuiting failure of an electronic device. Moreover,the growth mechanism of ZnO whiskers is researched based on cracked oxide theory,which provides the reference support for SnZn solders application.展开更多
In this paper, we design and fabricate a silicon integrated optical filter consisting of two cascaded micro-ring resonators and two straight waveguides. Two micro-heaters are fabricated on the top of two micro-rings r...In this paper, we design and fabricate a silicon integrated optical filter consisting of two cascaded micro-ring resonators and two straight waveguides. Two micro-heaters are fabricated on the top of two micro-rings respectively, which are employed to modulate the micro-rings to perform the function of a tunable optical filter by the thermo–optic effect. The static response test indicates that the extinction ratio and 3-d B bandwidth are 29.01 d B and 0.21 nm respectively, the dynamic response test indicates that the 10%–90% rise and 90%–10% fall time of the filter are 16 μs and 12 μs, respectively,which can meet the requirements of optical communication and information processing. Finally, the power consumption of the device is also characterized, and the total power consumption is about 9.43 m W/nm, which has been improved efficiently.展开更多
Voluntary participation of hemiplegic patients is crucial for functional electrical stimulation therapy.A wearable functional electrical stimulation system has been proposed for real-time volitional hand motor functio...Voluntary participation of hemiplegic patients is crucial for functional electrical stimulation therapy.A wearable functional electrical stimulation system has been proposed for real-time volitional hand motor function control using the electromyography bridge method.Through a series of novel design concepts,including the integration of a detecting circuit and an analog-to-digital converter,a miniaturized functional electrical stimulation circuit technique,a low-power super-regeneration chip for wireless receiving,and two wearable armbands,a prototype system has been established with reduced size,power,and overall cost.Based on wrist joint torque reproduction and classification experiments performed on six healthy subjects,the optimized surface electromyography thresholds and trained logistic regression classifier parameters were statistically chosen to establish wrist and hand motion control with high accuracy.Test results showed that wrist flexion/extension,hand grasp,and finger extension could be reproduced with high accuracy and low latency.This system can build a bridge of information transmission between healthy limbs and paralyzed limbs,effectively improve voluntary participation of hemiplegic patients,and elevate efficiency of rehabilitation training.展开更多
A new BPSK demodulator was presented.By using a clock multiplier with very simple circuit structure to replace the analog multiplier in the traditional BPSK demodulator,the circuit structure of the demodulator became ...A new BPSK demodulator was presented.By using a clock multiplier with very simple circuit structure to replace the analog multiplier in the traditional BPSK demodulator,the circuit structure of the demodulator became simpler and hence its power consumption became lower.Simpler structure and lower power will make the designed demodulator more suitable for use in an internal single chip design for a wireless implantable neural recording system.The proposed BPSK demodulator was implemented by Global Foundries 0.35μm CMOS technology with a 3.3 V power supply.The designed chip area is only 0.07 mm;and the power consumption is 0.5 mW.The test results show that it can work correctly.展开更多
文摘Device physics research for submicron and deep submicron space microelectronics devices and integrated circuits will be described in three topics.1.Thin film submicron and deep submicron SOS / CMOS devices and integrated circuits.2.Deep submicron LDD CMOS devices and integrated circuits.3.C band and Ku band microwave GaAs MESFET and III-V compound hetrojunction HEM T and HBT devices and integrated circuits.
文摘The tokamak HT-7U project has been funded as a Chinese national project since 1998. The main object of the project is to build a nuclear fusion experimental device with divertor configuration, which is designed by the Institute of Plasma Physics, the Chinese Academy of Sciences (ASIPP). It is a full superconducting device, consisting of superconducting toroidal field (TF) coils and superconducting poloidal field (PF) coil. During the operation of the device, the operational parameter of device should be checked by technical diagnosis. This paper describes the design of circuit for checldng short between every two parts of the HT7U device. The main contents of design include circuit of data acquisition and data processing of computer.
文摘The concept of Internet of Things(IoT)was first proposed by MIT Prof.Kevin Ash-ton in 1999.The implementation of IoT was mainly through RFID in its early time.With advanced technology and manufacture,diverse implementation forms of IoT are becoming possible.Wearable devices,as an essential branch of IoT,will have broad application prospects in health monitoring and intelligent healthcare.
基金Supported by the National Natural Science Foundation of China(No.51475220)State Foundation of Laboratory of Advanced Brazing Filler Metals&Technology(Zhengzhou Research Institute of Mechanical Engineering)(No.SKLABFMT-2015-03)High Level Talent Plan of Jiangsu Normal University(No.YQ2015002)
文摘ZnO whiskers observation on the surface of SnZn/Cu solder joints in concentrator silicon solar cells solder layer is reported. In the experiment,SnZn/Cu samples are left in laboratory after reflow soldering for two years before an examination by SEM,then ZnO whiskers can be observed obviously,which grows out from the rich-Zn phase of the samples and causes electrical short circuit in the electronics appliances,which demonstrates that the SnZn solder shows a risk for the short circuiting failure of an electronic device. Moreover,the growth mechanism of ZnO whiskers is researched based on cracked oxide theory,which provides the reference support for SnZn solders application.
基金Project supported by the National Natural Science Foundation of China(Grant No.61405082)the Fundamental Research Funds for the Central Universities
文摘In this paper, we design and fabricate a silicon integrated optical filter consisting of two cascaded micro-ring resonators and two straight waveguides. Two micro-heaters are fabricated on the top of two micro-rings respectively, which are employed to modulate the micro-rings to perform the function of a tunable optical filter by the thermo–optic effect. The static response test indicates that the extinction ratio and 3-d B bandwidth are 29.01 d B and 0.21 nm respectively, the dynamic response test indicates that the 10%–90% rise and 90%–10% fall time of the filter are 16 μs and 12 μs, respectively,which can meet the requirements of optical communication and information processing. Finally, the power consumption of the device is also characterized, and the total power consumption is about 9.43 m W/nm, which has been improved efficiently.
基金supported by the National Natural Science Foundation of China,No.90307013,90707005,61534003the Science&Technology Pillar Program of Jiangsu Province in China,No.BE2013706
文摘Voluntary participation of hemiplegic patients is crucial for functional electrical stimulation therapy.A wearable functional electrical stimulation system has been proposed for real-time volitional hand motor function control using the electromyography bridge method.Through a series of novel design concepts,including the integration of a detecting circuit and an analog-to-digital converter,a miniaturized functional electrical stimulation circuit technique,a low-power super-regeneration chip for wireless receiving,and two wearable armbands,a prototype system has been established with reduced size,power,and overall cost.Based on wrist joint torque reproduction and classification experiments performed on six healthy subjects,the optimized surface electromyography thresholds and trained logistic regression classifier parameters were statistically chosen to establish wrist and hand motion control with high accuracy.Test results showed that wrist flexion/extension,hand grasp,and finger extension could be reproduced with high accuracy and low latency.This system can build a bridge of information transmission between healthy limbs and paralyzed limbs,effectively improve voluntary participation of hemiplegic patients,and elevate efficiency of rehabilitation training.
基金Project supported by the National Natural Science Foundation of China(Nos.60976026,61076023)the National Basic Research Program of China(No.2011CB933203)the Fundamental Research Funds for the Central Universities,SCUT(No.2009ZM0196)
文摘A new BPSK demodulator was presented.By using a clock multiplier with very simple circuit structure to replace the analog multiplier in the traditional BPSK demodulator,the circuit structure of the demodulator became simpler and hence its power consumption became lower.Simpler structure and lower power will make the designed demodulator more suitable for use in an internal single chip design for a wireless implantable neural recording system.The proposed BPSK demodulator was implemented by Global Foundries 0.35μm CMOS technology with a 3.3 V power supply.The designed chip area is only 0.07 mm;and the power consumption is 0.5 mW.The test results show that it can work correctly.