In this paper, clear liquid fermentation condition for ethanol production from Canna edulis Kerl with orthogonal design was studied. We have studied five factors that influenced clear liquid fermentation condition for...In this paper, clear liquid fermentation condition for ethanol production from Canna edulis Kerl with orthogonal design was studied. We have studied five factors that influenced clear liquid fermentation condition for ethanol production from Canna edulis Kerl by the single-factor test. The five factors were α-amylase amount, glu-coamylase amount, pH, nitrogen and auxiliary materials amount. Selected the best amounts of α-amylase, glucoamylase, pH, nitrogen source and auxiliary materials by means of the singe- factors test. And then, we used the Orthogonal test to optimize the fermentation process. The study showed that the best fermentation condi-tions were α-amylase amount 7 u/g C.eduli, glu-coamylase amount 145u/g C. edulis, pH 4.4 and the amount of urea 0.08%, 1% of rice bran as auxiliary materials. The rate of alcohol which was produced by the best fermentation conditions is 21.5% that increased by 1.3% than the rate of alcohol by the single-factor test.展开更多
The calibration model for simultaneous deter-mination of chlorogenic acid and baicalin in heat-clearing and detoxicating oral liquid was built by partial least squares and near infrared spectroscopy, and the method of...The calibration model for simultaneous deter-mination of chlorogenic acid and baicalin in heat-clearing and detoxicating oral liquid was built by partial least squares and near infrared spectroscopy, and the method of spectral pre-treatment was discussed. Building model from calibration set obtained good results, and vali-dated by prediction. According to heat-clearing and detoxicating oral liquid from 30 batches of 6 factories, the correlation coefficient of chloro-genic acid and baicalin model are 0.9993 and 0.9923, The root mean square error of cross validation (RMSECV) are 0.467 and 0.480, and the standard Error of prediction (SEP) of chloro- genic acid and baicalin are 0.356 and 0.370 re-spectively. The correlation coefficients in pre-diction set are 0.9997 and 0.9969, prediction results are accurate and reliable. This method can be applied in rapid analysis of heat- clearing and detoxicating oral liquid, and it is fit for on-line detection and has a wide application prospect.展开更多
文摘In this paper, clear liquid fermentation condition for ethanol production from Canna edulis Kerl with orthogonal design was studied. We have studied five factors that influenced clear liquid fermentation condition for ethanol production from Canna edulis Kerl by the single-factor test. The five factors were α-amylase amount, glu-coamylase amount, pH, nitrogen and auxiliary materials amount. Selected the best amounts of α-amylase, glucoamylase, pH, nitrogen source and auxiliary materials by means of the singe- factors test. And then, we used the Orthogonal test to optimize the fermentation process. The study showed that the best fermentation condi-tions were α-amylase amount 7 u/g C.eduli, glu-coamylase amount 145u/g C. edulis, pH 4.4 and the amount of urea 0.08%, 1% of rice bran as auxiliary materials. The rate of alcohol which was produced by the best fermentation conditions is 21.5% that increased by 1.3% than the rate of alcohol by the single-factor test.
文摘The calibration model for simultaneous deter-mination of chlorogenic acid and baicalin in heat-clearing and detoxicating oral liquid was built by partial least squares and near infrared spectroscopy, and the method of spectral pre-treatment was discussed. Building model from calibration set obtained good results, and vali-dated by prediction. According to heat-clearing and detoxicating oral liquid from 30 batches of 6 factories, the correlation coefficient of chloro-genic acid and baicalin model are 0.9993 and 0.9923, The root mean square error of cross validation (RMSECV) are 0.467 and 0.480, and the standard Error of prediction (SEP) of chloro- genic acid and baicalin are 0.356 and 0.370 re-spectively. The correlation coefficients in pre-diction set are 0.9997 and 0.9969, prediction results are accurate and reliable. This method can be applied in rapid analysis of heat- clearing and detoxicating oral liquid, and it is fit for on-line detection and has a wide application prospect.