Distribution feeder microgrid(DFM)built based on existing distributed feeder(DF),is a promising solution for modern microgrid.DFM contains a large number of heterogeneous devices that generate heavy network traffice a...Distribution feeder microgrid(DFM)built based on existing distributed feeder(DF),is a promising solution for modern microgrid.DFM contains a large number of heterogeneous devices that generate heavy network traffice and require a low data delivery latency.The information-centric networking(ICN)paradigm has shown a great potential to address the communication requirements of smart grid.However,the integration of advanced information and communication technologies with DFM make it vulnerable to cyber attacks.Adequate authentication of grid devices is essential for preventing unauthorized accesses to the grid network and defending against cyber attacks.In this paper,we propose a new lightweight anonymous device authentication scheme for DFM supported by named data networking(NDN),a representative implementation of ICN.We perform a security analysis to show that the proposed scheme can provide security features such as mutual authentication,session key agreement,defending against various cyber attacks,anonymity,and resilience against device capture attack.The security of the proposed scheme is also formally verified using the popular AVISPA(Automated Validation of Internet Security Protocols and Applications)tool.The computational and communication costs of the proposed scheme are evaluated.Our results demonstrate that the proposed scheme achieves significantly lower computational,communication and energy costs than other state-of-the-art schemes.展开更多
In this research, the performance of the solar thermal powered systems (STPS) is analyzed with different models (without inserts, with inserts and with Nano fluids with different concentrations) and its impact on the ...In this research, the performance of the solar thermal powered systems (STPS) is analyzed with different models (without inserts, with inserts and with Nano fluids with different concentrations) and its impact on the Electric load in a residential/Institutional Electrical Distribution system. For this purpose, the electrical and solar thermal water heater is tested and validated. Solar thermal powered systems and its impact on the Institutional electrical distribution feeders are tested and compared with the energy efficiency (EE) and cost optimization. The goal of this paper is to analyze the impact of solar thermal energy on electrical energy consumption in the electrical distribution feeder level. The electrical system cost and energy consumptions are tabulated and observed that there is a considerable savings.展开更多
The rapid spreading of the Photovoltaic (PV) Systems as Distributed Generation (DG) in medium and low voltage networks created many effects and changes on the existing power system networks. In this work, two methods ...The rapid spreading of the Photovoltaic (PV) Systems as Distributed Generation (DG) in medium and low voltage networks created many effects and changes on the existing power system networks. In this work, two methods have been used and applied to determine the optimal allocation and sizing of the PV to be installed as DGs (ranging from 250 kW up to 3 MW). The first one is to determine the location according to the maximal power losses reduction over the feeder. The second one is by using the Harmony Search Algorithm which is claimed to be a powerful technique for optimal allocation of PV systems. The results of the two techniques were compared and found to be nearly closed. Furthermore, investigation on the effects on the feeder in terms of voltage levels, power factor readings, and short circuit current levels has been done. All calculations and simulations are conducted by using the MATLAB Simulation Program. Some field calculations and observations have been expended in order to substantiate the research findings and validation.展开更多
Intelligent distribution automation system (IDAS) was developed based on distribution automation system that was installed in all distribution offices of Korea. IDAS was designed the combined system with the functio...Intelligent distribution automation system (IDAS) was developed based on distribution automation system that was installed in all distribution offices of Korea. IDAS was designed the combined system with the function of supervisory control and data acquisition (SCADA) and distribution automation system (DAS) for network operation from substation to high voltage customer, and it has been installed in Vietnam, China and Indonesia. This paper explains the project scope, system configuration, and the function of each sy stem.展开更多
针对馈线自动化的功能测试问题,为避免配电终端接入实际配电网进行测试实验可能对电力系统的安全运行造成不利影响,同时为了提高测试的灵活性、效率性和正确性,文中提出了一种虚实结合的馈线自动化测试方法,利用RTLAB(Real Time Laborat...针对馈线自动化的功能测试问题,为避免配电终端接入实际配电网进行测试实验可能对电力系统的安全运行造成不利影响,同时为了提高测试的灵活性、效率性和正确性,文中提出了一种虚实结合的馈线自动化测试方法,利用RTLAB(Real Time Laboratory)实时全数字仿真器搭建配电网并模拟故障运行,设计具备保护、重合闸、就地式FA(Feeder Automation)功能的仿真型虚拟配电终端用于开展RTLAB实时仿真器与物理模型硬件在环仿真研究。文中设计的基于高性能线性功率放大器的接口实施方案被测配电终端接入测试系统形成闭环,构建了虚实结合的馈线自动化仿真测试环境。通过开展基本故障处理能力测试和容错能力测试的硬件在环仿真实验,验证了接口装置的准确性,同时验证了测试平台的有效性。展开更多
基金This material is based upon work funded by the National Science Foundation EPSCoR Cooperative Agreement OIA-1757207。
文摘Distribution feeder microgrid(DFM)built based on existing distributed feeder(DF),is a promising solution for modern microgrid.DFM contains a large number of heterogeneous devices that generate heavy network traffice and require a low data delivery latency.The information-centric networking(ICN)paradigm has shown a great potential to address the communication requirements of smart grid.However,the integration of advanced information and communication technologies with DFM make it vulnerable to cyber attacks.Adequate authentication of grid devices is essential for preventing unauthorized accesses to the grid network and defending against cyber attacks.In this paper,we propose a new lightweight anonymous device authentication scheme for DFM supported by named data networking(NDN),a representative implementation of ICN.We perform a security analysis to show that the proposed scheme can provide security features such as mutual authentication,session key agreement,defending against various cyber attacks,anonymity,and resilience against device capture attack.The security of the proposed scheme is also formally verified using the popular AVISPA(Automated Validation of Internet Security Protocols and Applications)tool.The computational and communication costs of the proposed scheme are evaluated.Our results demonstrate that the proposed scheme achieves significantly lower computational,communication and energy costs than other state-of-the-art schemes.
文摘In this research, the performance of the solar thermal powered systems (STPS) is analyzed with different models (without inserts, with inserts and with Nano fluids with different concentrations) and its impact on the Electric load in a residential/Institutional Electrical Distribution system. For this purpose, the electrical and solar thermal water heater is tested and validated. Solar thermal powered systems and its impact on the Institutional electrical distribution feeders are tested and compared with the energy efficiency (EE) and cost optimization. The goal of this paper is to analyze the impact of solar thermal energy on electrical energy consumption in the electrical distribution feeder level. The electrical system cost and energy consumptions are tabulated and observed that there is a considerable savings.
文摘The rapid spreading of the Photovoltaic (PV) Systems as Distributed Generation (DG) in medium and low voltage networks created many effects and changes on the existing power system networks. In this work, two methods have been used and applied to determine the optimal allocation and sizing of the PV to be installed as DGs (ranging from 250 kW up to 3 MW). The first one is to determine the location according to the maximal power losses reduction over the feeder. The second one is by using the Harmony Search Algorithm which is claimed to be a powerful technique for optimal allocation of PV systems. The results of the two techniques were compared and found to be nearly closed. Furthermore, investigation on the effects on the feeder in terms of voltage levels, power factor readings, and short circuit current levels has been done. All calculations and simulations are conducted by using the MATLAB Simulation Program. Some field calculations and observations have been expended in order to substantiate the research findings and validation.
文摘Intelligent distribution automation system (IDAS) was developed based on distribution automation system that was installed in all distribution offices of Korea. IDAS was designed the combined system with the function of supervisory control and data acquisition (SCADA) and distribution automation system (DAS) for network operation from substation to high voltage customer, and it has been installed in Vietnam, China and Indonesia. This paper explains the project scope, system configuration, and the function of each sy stem.
文摘针对馈线自动化的功能测试问题,为避免配电终端接入实际配电网进行测试实验可能对电力系统的安全运行造成不利影响,同时为了提高测试的灵活性、效率性和正确性,文中提出了一种虚实结合的馈线自动化测试方法,利用RTLAB(Real Time Laboratory)实时全数字仿真器搭建配电网并模拟故障运行,设计具备保护、重合闸、就地式FA(Feeder Automation)功能的仿真型虚拟配电终端用于开展RTLAB实时仿真器与物理模型硬件在环仿真研究。文中设计的基于高性能线性功率放大器的接口实施方案被测配电终端接入测试系统形成闭环,构建了虚实结合的馈线自动化仿真测试环境。通过开展基本故障处理能力测试和容错能力测试的硬件在环仿真实验,验证了接口装置的准确性,同时验证了测试平台的有效性。