A type of single neuron adaptive PID regulator with auto-tuning gain is proposed and applied to the work control of fans, waterpumps and air-pressers etc. in Handan Iron & Steel Compel China. The robusthess of ind...A type of single neuron adaptive PID regulator with auto-tuning gain is proposed and applied to the work control of fans, waterpumps and air-pressers etc. in Handan Iron & Steel Compel China. The robusthess of induStrial parameter closed-loop process controlsystems is improved, and the work quality of the systems bettered.展开更多
The replacement of winter wheat varieties has contributed significantly to yield improvement worldwide,with remarkable progress in China.Drawing on two sets of data,production yield from the National Bureau of Statist...The replacement of winter wheat varieties has contributed significantly to yield improvement worldwide,with remarkable progress in China.Drawing on two sets of data,production yield from the National Bureau of Statistics of China and experimental yield from literature,this study aims to(1)illustrate the increasing patterns of production yield among different provinces from 1978 to 2018 in China,(2)explore the genetic gain in yield and yield relevant traits through the variety replacement based on experimental yield from 1937 to 2016 in China,and(3)compare the yield gap between experimental yield and production yield.The results show that both the production and experimental yields significantly increased along with the variety replacement.The national annual yield increase ratio for the production yield was 1.67%from 1978 to 2018,varying from 0.96%in Sichuan Province to 2.78%in Hebei Province;such ratio for the experimental yield was 1.13%from 1937 to 2016.The yield gap between experimental and production yields decreased from the 1970s to the 2010s.This study reveals significant increases in some yield components consequent to variety replacement,including thousand-grain weight,kernel number per spike,and grain number per square meter;however,no change is shown in spike number per square meter.The biomass and harvest index consistently and significantly increased,whereas the plant height decreased significantly.展开更多
Background Rumen bacterial groups can affect growth performance,such as average daily gain(ADG),feed intake,and efficiency.The study aimed to investigate the inter-relationship of rumen bacterial composition,rumen fer...Background Rumen bacterial groups can affect growth performance,such as average daily gain(ADG),feed intake,and efficiency.The study aimed to investigate the inter-relationship of rumen bacterial composition,rumen fermentation indicators,serum indicators,and growth performance of Holstein heifer calves with different ADG.Twelve calves were chosen from a trail with 60 calves and divided into higher ADG(HADG,high pre-and post-weaning ADG,n=6)and lower ADG(LADG,low pre-and post-weaning ADG,n=6)groups to investigate differences in bacterial composition and functions and host phenotype.Results During the preweaning period,the relative abundances of propionate producers,including g_norank_f_Butyricicoccaceae,g_Pyramidobacter,and g_norank_f_norank_o_Clostridia_vadin BB60_group,were higher in HADG calves(LDA>2,P<0.05).Enrichment of these bacteria resulted in increased levels of propionate,a gluconeogenic precursor,in preweaning HADG calves(adjusted P<0.05),which consequently raised serum glucose concentrations(adjusted P<0.05).In contrast,the relative abundances of rumen bacteria in post-weaning HADG calves did not exert this effect.Moreover,no significant differences were observed in rumen fermentation parameters and serum indices between the two groups.Conclusions The findings of this study revealed that the preweaning period is the window of opportunity for rumen bacteria to regulate the ADG of calves.展开更多
We investigate the higher-order topological laser in the two-dimensional(2D) coupled-cavity array. By adding staggered on-site gain and loss to the 2D Hermitian array with a trivial phase, the system will emerge degen...We investigate the higher-order topological laser in the two-dimensional(2D) coupled-cavity array. By adding staggered on-site gain and loss to the 2D Hermitian array with a trivial phase, the system will emerge degenerate topological corner modes, which are protected by bulk band gap. For such a non-Hermitian model, by adjusting the parameters of the system and introducing the pumping into the cavity at the corner, a single-mode lasing with topological protection emerges.Furthermore, single-mode lasing exists over a wide range of pumping strengths. No matter where the cavity is initially stimulated, after enough time evolution, all the cavities belonging to the topological corner mode can emit a stable laser.展开更多
Collisions between a moving mass and an anti-collision device increase structural responses and threaten structural safety.An active mass damper(AMD)with stroke limitations is often used to avoid collisions.However,a ...Collisions between a moving mass and an anti-collision device increase structural responses and threaten structural safety.An active mass damper(AMD)with stroke limitations is often used to avoid collisions.However,a strokelimited AMD control system with a fixed limited area shortens the available AMD stroke and leads to significant control power.To solve this problem,the design approach with variable gain and limited area(VGLA)is proposed in this study.First,the boundary of variable-limited areas is calculated based on the real-time status of the moving mass.The variable gain(VG)expression at the variable limited area is deduced by considering the saturation of AMD stroke.Then,numerical simulations of a stroke-limited AMD control system with VGLA are conducted on a high-rise building structure.These numerical simulations show that the proposed approach has superior strokelimitation performance compared with a stroke-limited AMD control system with a fixed limited area.Finally,the proposed approach is validated through experiments on a four-story steel frame.展开更多
Security during remote transmission has been an important concern for researchers in recent years.In this paper,a hierarchical encryption multi-image encryption scheme for people with different security levels is desi...Security during remote transmission has been an important concern for researchers in recent years.In this paper,a hierarchical encryption multi-image encryption scheme for people with different security levels is designed,and a multiimage encryption(MIE)algorithm with row and column confusion and closed-loop bi-directional diffusion is adopted in the paper.While ensuring secure communication of medical image information,people with different security levels have different levels of decryption keys,and differentiated visual effects can be obtained by using the strong sensitivity of chaotic keys.The highest security level can obtain decrypted images without watermarks,and at the same time,patient information and copyright attribution can be verified by obtaining watermark images.The experimental results show that the scheme is sufficiently secure as an MIE scheme with visualized differences and the encryption and decryption efficiency is significantly improved compared to other works.展开更多
开展脉冲重复间隔(Pulse Repetition Interval,PRI)模式识别工作是电子支援系统的一项重要任务。现代复杂电磁环境下,受雷达辐射源部署和接收设备本身影响,雷达脉冲丢失率极高,导致分选后PRI序列调制规律被破坏,现有的PRI模式识别方法...开展脉冲重复间隔(Pulse Repetition Interval,PRI)模式识别工作是电子支援系统的一项重要任务。现代复杂电磁环境下,受雷达辐射源部署和接收设备本身影响,雷达脉冲丢失率极高,导致分选后PRI序列调制规律被破坏,现有的PRI模式识别方法准确率不足。针对上述问题,从PRI序列还原角度出发,并结合PRI序列本质是时序序列的特点,提出GAIN-LSTM(Generative Adversarial Imputation Nets and Long Short Term Memory)网络架构,其先对丢失脉冲位置进行补全操作,恢复PRI调制规律,然后对还原后PRI序列进行调制模式识别。仿真结果表明,提出的GAIN-LSTM网络架构在脉冲丢失率70%时仍保持95%的正确识别率。展开更多
BACKGROUND In 2016,the Food and Drug Administration approved the first hybrid closed-loop(HCL)insulin delivery system for adults with type 1 diabetes(T1D).There is limited information on the impact of using HCL system...BACKGROUND In 2016,the Food and Drug Administration approved the first hybrid closed-loop(HCL)insulin delivery system for adults with type 1 diabetes(T1D).There is limited information on the impact of using HCL systems on patient-reported outcomes(PROs)in patients with T1D in real-world clinical practice.In this independent study,we evaluated glycemic parameters and PROs over one year of continuous use of Medtronic’s 670G HCL in real-world clinical practice.AIM To assess the effects of hybrid closed loop system on glycemic control and quality of life in adults with T1D.METHODS We evaluated 71 patients with T1D(mean age:45.5±12.1 years;59%females;body weight:83.8±18.7 kg,body mass index:28.7±5.6 kg/m2,A1C:7.6%±0.8%)who were treated with HCL at Joslin Clinic from 2017 to 2019.We measured A1C and percent of glucose time-in-range(%TIR)at baseline and 12 months.We measured percent time in auto mode(%TiAM)for the last two weeks preceding the final visit and assessed PROs through several validated quality-of-life surveys related to general health and diabetes management.RESULTS At 12 mo,A1C decreased by 0.3%±0.1%(P=0.001)and%TIR increased by 8.1%±2.5%(P=0.002).The average%TiAM was only 64.3%±32.8%and was not associated with A1C,%TIR or PROs.PROs,provided at baseline and at the end of the study,showed that the physical functioning submodule of 36Item Short-Form Health Survey increased significantly by 22.9%(P<0.001).Hypoglycemia fear survey/worry scale decreased significantly by 24.9%(P<0.000);Problem Areas In Diabetes reduced significantly by-17.2%(P=0.002).The emotional burden submodules of dietary diversity score reduced significantly by-44.7%(P=0.001).Furthermore,analysis of Clarke questionnaire showed no increase in awareness of hypoglycemic episodes.WHO-5 showed no improvements in subject’s wellbeing among participants after starting the 670G HCL system.Finally,analysis of Pittsburgh Sleep Quality Index showed no difference in sleep quality,sleep latency,or duration of sleep from baseline to 12 mo.CONCLUSION The use of HCL in real-world clinical practice for one year was associated with significant improvements in A1C,%TIR,physical functioning,hypoglycemia fear,emotional distress,and emotional burden related to diabetes management.However,these changes were not associated with time in auto mode.展开更多
In recent years,switched inductor(SL)technology,switched capacitor(SC)technology,and switched inductor-capacitor(SL-SC)technology have been widely applied to optimize and improve DC-DC boost converters,which can effec...In recent years,switched inductor(SL)technology,switched capacitor(SC)technology,and switched inductor-capacitor(SL-SC)technology have been widely applied to optimize and improve DC-DC boost converters,which can effectively enhance voltage gain and reduce device stress.To address the issue of low output voltage in current renewable energy power generation systems,this study proposes a novel non-isolated cubic high-gain DC-DC converter based on the traditional quadratic DC-DC boost converter by incorporating a SC and a SL-SC unit.Firstly,the proposed converter’s details are elaborated,including its topology structure,operating mode,voltage gain,device stress,and power loss.Subsequently,a comparative analysis is conducted on the voltage gain and device stress between the proposed converter and other high-gain converters.Then,a closed-loop simulation system is constructed to obtain simulation waveforms of various devices and explore the dynamic performance.Finally,an experimental prototype is built,experimental waveforms are obtained,and the experimental dynamic performance and conversion efficiency are analyzed.The theoretical analysis’s correctness is verified through simulation and experimental results.The proposed converter has advantages such as high voltage gain,low device stress,high conversion efficiency,simple control,and wide input voltage range,achieving a good balance between voltage gain,device stress,and power loss.The proposed converter is well-suited for renewable energy systems and holds theoretical significance and practical value in renewable energy applications.It provides an effective solution to the issue of low output voltage in renewable energy power generation systems.展开更多
This work details the development of a broad-spectrum LNA (Low Noise Amplifier) circuit using a 65 nm CMOS technology. The design incorporates an inductive degeneracy circuit, employing a theoretical approach to enhan...This work details the development of a broad-spectrum LNA (Low Noise Amplifier) circuit using a 65 nm CMOS technology. The design incorporates an inductive degeneracy circuit, employing a theoretical approach to enhance gain, minimize noise levels, and uphold low power consumption. The progression includes a shift to a cascode structure to further refine LNA parameters. Ultimately, with a 1.8 V bias, the achieved performance showcases a gain-to-noise figure ratio of 16 dB/0.5 dB, an IIP3 linearity at 5.1 dBm, and a power consumption of 3 mW. This architecture is adept at operating across a wide frequency band spanning from 0.5 GHz to 6 GHz, rendering it applicable in diverse RF scenarios.展开更多
The joint beamforming design challenge for dual-functional radar-communication systems is addressed in this paper.The base station in these systems is tasked with simultaneously sending shared signals for both multi-u...The joint beamforming design challenge for dual-functional radar-communication systems is addressed in this paper.The base station in these systems is tasked with simultaneously sending shared signals for both multi-user communication and target sensing.The primary objective is to maximize the sum rate of multi-user communication,while also ensuring sufficient beampattern gain at particular angles that are of interest for sensing,all within the constraints of the transmit power budget.To tackle this complex non-convex problem,an effective algorithm that iteratively optimizes the joint beamformers is developed.This algorithm leverages the techniques of fractional programming and semidefinite relaxation to achieve its goals.The numerical results confirm the effectiveness of the proposed algorithm.展开更多
Objective:To investigate the effects of maternal body mass index(BMI)and gestational weight gain on maternal and neonatal outcomes in twin pregnancies.Methods:Five hundred cases of twin pregnancies were divided into a...Objective:To investigate the effects of maternal body mass index(BMI)and gestational weight gain on maternal and neonatal outcomes in twin pregnancies.Methods:Five hundred cases of twin pregnancies were divided into a low body weight group(68 cases),a normal weight group(355 cases),an overweight group(65 cases),and an obesity group(12 cases)according to the World Health Organization(WHO)Body Mass Index(BMI)classification guidelines Results:Comparison of weight gain during different pregnancies revealed that pregnant women were mainly of low weight and average weight.The higher the BMI before pregnancy,the higher the incidence of excessive weight gain during pregnancy.The incidences of gestational diabetes mellitus(GDM)and premature rupture of membranes in women with low weight gain were significantly higher than those in women with average weight gain and high weight gain(P<0.05).The incidences of gestational hypertension,preeclampsia,and anemia in women with high weight gain were significantly higher than those in women with low weight gain and average weight gain(P<0.05).The incidence of neonatal birth weight,fetal distress,and macrosomia in the high weight gain group was significantly higher than those in the low weight gain and average weight gain groups(P<0.05).The birth weight of newborns in low-weight gain mothers was significantly lower than that of normal-weight gain mothers(P<0.05).Conclusion:Poor maternal and infant outcomes were common in women with insufficient or excessive weight gain during pregnancy.Therefore,for women with twin pregnancies,weight management is crucial to ensure maternal and infant health.展开更多
提出一种基于人工磁导体(Artificial Magnetic Conductor, AMC)的高增益宽带天线,该天线由一个AMC超表面和一个微带贴片天线组成。利用AMC的同相反射特性,将天线的后向辐射反射与前向辐射叠加,从而提升了天线的增益。天线的整体尺寸为0....提出一种基于人工磁导体(Artificial Magnetic Conductor, AMC)的高增益宽带天线,该天线由一个AMC超表面和一个微带贴片天线组成。利用AMC的同相反射特性,将天线的后向辐射反射与前向辐射叠加,从而提升了天线的增益。天线的整体尺寸为0.6λ_(0)×0.6λ_(0)×0.12λ_(0) (λ_(0)为天线谐振频率对应的波长)。测试结果表明,在4.55~6.1 GHz (27.7%)的工作频段内,天线的峰值增益达到8.4 dB。与利用理想电导体(Perfect Electric Conductor, PEC)提升增益的方法相比,其剖面从0.37λ_(0)降低到0.12λ_(0)。该天线剖面低、尺寸小、增益高、成本低廉,可以应用于WLAN波段通信。展开更多
A four-stage monolithic microwave integrated circuits (MMIC) low noise amplifier (LNA) operating from 23 to 36GHz is reported using commercially available 0.15μm PHEMT technology. The LNA is self-biased. To achie...A four-stage monolithic microwave integrated circuits (MMIC) low noise amplifier (LNA) operating from 23 to 36GHz is reported using commercially available 0.15μm PHEMT technology. The LNA is self-biased. To achieve a low noise characteristic, careful optimizations of gate width are performed to reduce gate resistance. Absorption circuits and an elaborate bias structure with a resistor-capacitor network are employed to improve stability. Multiple resonance points and negative feedback technologies are used to widen the bandwidth. Measurements show a noise figure (NF) of less than 2.0dB,and the lowest NF is only 1.6dB at a frequency of 31GHz. In the whole operation band,the LNA has a gain of higher than 26dB,and an input return loss and output return loss of more than 11 and 13dB,respectively. The output power at ldB compression gain of 36GHz is about 14dBm. The chip area is 2.4mm ×1mm.展开更多
文摘A type of single neuron adaptive PID regulator with auto-tuning gain is proposed and applied to the work control of fans, waterpumps and air-pressers etc. in Handan Iron & Steel Compel China. The robusthess of induStrial parameter closed-loop process controlsystems is improved, and the work quality of the systems bettered.
基金This research was financially supported by the Natural Science Basic Research Program of Shaanxi,China(2022JM-126)the National Natural Science Foundation of China(52079132).
文摘The replacement of winter wheat varieties has contributed significantly to yield improvement worldwide,with remarkable progress in China.Drawing on two sets of data,production yield from the National Bureau of Statistics of China and experimental yield from literature,this study aims to(1)illustrate the increasing patterns of production yield among different provinces from 1978 to 2018 in China,(2)explore the genetic gain in yield and yield relevant traits through the variety replacement based on experimental yield from 1937 to 2016 in China,and(3)compare the yield gap between experimental yield and production yield.The results show that both the production and experimental yields significantly increased along with the variety replacement.The national annual yield increase ratio for the production yield was 1.67%from 1978 to 2018,varying from 0.96%in Sichuan Province to 2.78%in Hebei Province;such ratio for the experimental yield was 1.13%from 1937 to 2016.The yield gap between experimental and production yields decreased from the 1970s to the 2010s.This study reveals significant increases in some yield components consequent to variety replacement,including thousand-grain weight,kernel number per spike,and grain number per square meter;however,no change is shown in spike number per square meter.The biomass and harvest index consistently and significantly increased,whereas the plant height decreased significantly.
基金funded by National Key R&D Program of China(2022YFA1304204)Agricultural Science and Technology Innovation Program(CAAS-ASTIP-2017-FRI-04)Beijing Innovation Consortium of livestock Research System(BAIC05-2023)。
文摘Background Rumen bacterial groups can affect growth performance,such as average daily gain(ADG),feed intake,and efficiency.The study aimed to investigate the inter-relationship of rumen bacterial composition,rumen fermentation indicators,serum indicators,and growth performance of Holstein heifer calves with different ADG.Twelve calves were chosen from a trail with 60 calves and divided into higher ADG(HADG,high pre-and post-weaning ADG,n=6)and lower ADG(LADG,low pre-and post-weaning ADG,n=6)groups to investigate differences in bacterial composition and functions and host phenotype.Results During the preweaning period,the relative abundances of propionate producers,including g_norank_f_Butyricicoccaceae,g_Pyramidobacter,and g_norank_f_norank_o_Clostridia_vadin BB60_group,were higher in HADG calves(LDA>2,P<0.05).Enrichment of these bacteria resulted in increased levels of propionate,a gluconeogenic precursor,in preweaning HADG calves(adjusted P<0.05),which consequently raised serum glucose concentrations(adjusted P<0.05).In contrast,the relative abundances of rumen bacteria in post-weaning HADG calves did not exert this effect.Moreover,no significant differences were observed in rumen fermentation parameters and serum indices between the two groups.Conclusions The findings of this study revealed that the preweaning period is the window of opportunity for rumen bacteria to regulate the ADG of calves.
基金supported by the National Natural Science Foundation of China (Grant Nos. 12274326 and 12174288)the National Key R&D Program of China (Grant No. 2021YFA1400602)。
文摘We investigate the higher-order topological laser in the two-dimensional(2D) coupled-cavity array. By adding staggered on-site gain and loss to the 2D Hermitian array with a trivial phase, the system will emerge degenerate topological corner modes, which are protected by bulk band gap. For such a non-Hermitian model, by adjusting the parameters of the system and introducing the pumping into the cavity at the corner, a single-mode lasing with topological protection emerges.Furthermore, single-mode lasing exists over a wide range of pumping strengths. No matter where the cavity is initially stimulated, after enough time evolution, all the cavities belonging to the topological corner mode can emit a stable laser.
基金This research was founded by the Funds for Creative Research Groups of National Natural Science Foundation of China(Grant No.51921006)the National Natural Science Foundations of China(Grant No.51978224)+2 种基金the National Major Scientific Research Instrument Development Program of China(Grant No.51827811)the National Natural Science Foundation of China,(Grant No.52008141)the Shenzhen Technology Innovation Program(Grant Nos.JCYJ20170811160003571,JCYJ20180508152238111 and JCYJ20200109112803851).
文摘Collisions between a moving mass and an anti-collision device increase structural responses and threaten structural safety.An active mass damper(AMD)with stroke limitations is often used to avoid collisions.However,a strokelimited AMD control system with a fixed limited area shortens the available AMD stroke and leads to significant control power.To solve this problem,the design approach with variable gain and limited area(VGLA)is proposed in this study.First,the boundary of variable-limited areas is calculated based on the real-time status of the moving mass.The variable gain(VG)expression at the variable limited area is deduced by considering the saturation of AMD stroke.Then,numerical simulations of a stroke-limited AMD control system with VGLA are conducted on a high-rise building structure.These numerical simulations show that the proposed approach has superior strokelimitation performance compared with a stroke-limited AMD control system with a fixed limited area.Finally,the proposed approach is validated through experiments on a four-story steel frame.
基金Project supported by the National Natural Science Foundation of China(Grant No.62061014)the Natural Science Foundation of Liaoning province of China(Grant No.2020-MS-274).
文摘Security during remote transmission has been an important concern for researchers in recent years.In this paper,a hierarchical encryption multi-image encryption scheme for people with different security levels is designed,and a multiimage encryption(MIE)algorithm with row and column confusion and closed-loop bi-directional diffusion is adopted in the paper.While ensuring secure communication of medical image information,people with different security levels have different levels of decryption keys,and differentiated visual effects can be obtained by using the strong sensitivity of chaotic keys.The highest security level can obtain decrypted images without watermarks,and at the same time,patient information and copyright attribution can be verified by obtaining watermark images.The experimental results show that the scheme is sufficiently secure as an MIE scheme with visualized differences and the encryption and decryption efficiency is significantly improved compared to other works.
文摘开展脉冲重复间隔(Pulse Repetition Interval,PRI)模式识别工作是电子支援系统的一项重要任务。现代复杂电磁环境下,受雷达辐射源部署和接收设备本身影响,雷达脉冲丢失率极高,导致分选后PRI序列调制规律被破坏,现有的PRI模式识别方法准确率不足。针对上述问题,从PRI序列还原角度出发,并结合PRI序列本质是时序序列的特点,提出GAIN-LSTM(Generative Adversarial Imputation Nets and Long Short Term Memory)网络架构,其先对丢失脉冲位置进行补全操作,恢复PRI调制规律,然后对还原后PRI序列进行调制模式识别。仿真结果表明,提出的GAIN-LSTM网络架构在脉冲丢失率70%时仍保持95%的正确识别率。
文摘BACKGROUND In 2016,the Food and Drug Administration approved the first hybrid closed-loop(HCL)insulin delivery system for adults with type 1 diabetes(T1D).There is limited information on the impact of using HCL systems on patient-reported outcomes(PROs)in patients with T1D in real-world clinical practice.In this independent study,we evaluated glycemic parameters and PROs over one year of continuous use of Medtronic’s 670G HCL in real-world clinical practice.AIM To assess the effects of hybrid closed loop system on glycemic control and quality of life in adults with T1D.METHODS We evaluated 71 patients with T1D(mean age:45.5±12.1 years;59%females;body weight:83.8±18.7 kg,body mass index:28.7±5.6 kg/m2,A1C:7.6%±0.8%)who were treated with HCL at Joslin Clinic from 2017 to 2019.We measured A1C and percent of glucose time-in-range(%TIR)at baseline and 12 months.We measured percent time in auto mode(%TiAM)for the last two weeks preceding the final visit and assessed PROs through several validated quality-of-life surveys related to general health and diabetes management.RESULTS At 12 mo,A1C decreased by 0.3%±0.1%(P=0.001)and%TIR increased by 8.1%±2.5%(P=0.002).The average%TiAM was only 64.3%±32.8%and was not associated with A1C,%TIR or PROs.PROs,provided at baseline and at the end of the study,showed that the physical functioning submodule of 36Item Short-Form Health Survey increased significantly by 22.9%(P<0.001).Hypoglycemia fear survey/worry scale decreased significantly by 24.9%(P<0.000);Problem Areas In Diabetes reduced significantly by-17.2%(P=0.002).The emotional burden submodules of dietary diversity score reduced significantly by-44.7%(P=0.001).Furthermore,analysis of Clarke questionnaire showed no increase in awareness of hypoglycemic episodes.WHO-5 showed no improvements in subject’s wellbeing among participants after starting the 670G HCL system.Finally,analysis of Pittsburgh Sleep Quality Index showed no difference in sleep quality,sleep latency,or duration of sleep from baseline to 12 mo.CONCLUSION The use of HCL in real-world clinical practice for one year was associated with significant improvements in A1C,%TIR,physical functioning,hypoglycemia fear,emotional distress,and emotional burden related to diabetes management.However,these changes were not associated with time in auto mode.
基金This work was supported by China Railway Corporation Science and Technology Research and Development Project(P2021J038).
文摘In recent years,switched inductor(SL)technology,switched capacitor(SC)technology,and switched inductor-capacitor(SL-SC)technology have been widely applied to optimize and improve DC-DC boost converters,which can effectively enhance voltage gain and reduce device stress.To address the issue of low output voltage in current renewable energy power generation systems,this study proposes a novel non-isolated cubic high-gain DC-DC converter based on the traditional quadratic DC-DC boost converter by incorporating a SC and a SL-SC unit.Firstly,the proposed converter’s details are elaborated,including its topology structure,operating mode,voltage gain,device stress,and power loss.Subsequently,a comparative analysis is conducted on the voltage gain and device stress between the proposed converter and other high-gain converters.Then,a closed-loop simulation system is constructed to obtain simulation waveforms of various devices and explore the dynamic performance.Finally,an experimental prototype is built,experimental waveforms are obtained,and the experimental dynamic performance and conversion efficiency are analyzed.The theoretical analysis’s correctness is verified through simulation and experimental results.The proposed converter has advantages such as high voltage gain,low device stress,high conversion efficiency,simple control,and wide input voltage range,achieving a good balance between voltage gain,device stress,and power loss.The proposed converter is well-suited for renewable energy systems and holds theoretical significance and practical value in renewable energy applications.It provides an effective solution to the issue of low output voltage in renewable energy power generation systems.
文摘This work details the development of a broad-spectrum LNA (Low Noise Amplifier) circuit using a 65 nm CMOS technology. The design incorporates an inductive degeneracy circuit, employing a theoretical approach to enhance gain, minimize noise levels, and uphold low power consumption. The progression includes a shift to a cascode structure to further refine LNA parameters. Ultimately, with a 1.8 V bias, the achieved performance showcases a gain-to-noise figure ratio of 16 dB/0.5 dB, an IIP3 linearity at 5.1 dBm, and a power consumption of 3 mW. This architecture is adept at operating across a wide frequency band spanning from 0.5 GHz to 6 GHz, rendering it applicable in diverse RF scenarios.
基金supported in part by the National Natural Science Foundation of China under Grant No.62201266in part by the Natural Science Foundation of Jiangsu Province under Grant No.BK20210335.
文摘The joint beamforming design challenge for dual-functional radar-communication systems is addressed in this paper.The base station in these systems is tasked with simultaneously sending shared signals for both multi-user communication and target sensing.The primary objective is to maximize the sum rate of multi-user communication,while also ensuring sufficient beampattern gain at particular angles that are of interest for sensing,all within the constraints of the transmit power budget.To tackle this complex non-convex problem,an effective algorithm that iteratively optimizes the joint beamformers is developed.This algorithm leverages the techniques of fractional programming and semidefinite relaxation to achieve its goals.The numerical results confirm the effectiveness of the proposed algorithm.
文摘Objective:To investigate the effects of maternal body mass index(BMI)and gestational weight gain on maternal and neonatal outcomes in twin pregnancies.Methods:Five hundred cases of twin pregnancies were divided into a low body weight group(68 cases),a normal weight group(355 cases),an overweight group(65 cases),and an obesity group(12 cases)according to the World Health Organization(WHO)Body Mass Index(BMI)classification guidelines Results:Comparison of weight gain during different pregnancies revealed that pregnant women were mainly of low weight and average weight.The higher the BMI before pregnancy,the higher the incidence of excessive weight gain during pregnancy.The incidences of gestational diabetes mellitus(GDM)and premature rupture of membranes in women with low weight gain were significantly higher than those in women with average weight gain and high weight gain(P<0.05).The incidences of gestational hypertension,preeclampsia,and anemia in women with high weight gain were significantly higher than those in women with low weight gain and average weight gain(P<0.05).The incidence of neonatal birth weight,fetal distress,and macrosomia in the high weight gain group was significantly higher than those in the low weight gain and average weight gain groups(P<0.05).The birth weight of newborns in low-weight gain mothers was significantly lower than that of normal-weight gain mothers(P<0.05).Conclusion:Poor maternal and infant outcomes were common in women with insufficient or excessive weight gain during pregnancy.Therefore,for women with twin pregnancies,weight management is crucial to ensure maternal and infant health.
文摘A four-stage monolithic microwave integrated circuits (MMIC) low noise amplifier (LNA) operating from 23 to 36GHz is reported using commercially available 0.15μm PHEMT technology. The LNA is self-biased. To achieve a low noise characteristic, careful optimizations of gate width are performed to reduce gate resistance. Absorption circuits and an elaborate bias structure with a resistor-capacitor network are employed to improve stability. Multiple resonance points and negative feedback technologies are used to widen the bandwidth. Measurements show a noise figure (NF) of less than 2.0dB,and the lowest NF is only 1.6dB at a frequency of 31GHz. In the whole operation band,the LNA has a gain of higher than 26dB,and an input return loss and output return loss of more than 11 and 13dB,respectively. The output power at ldB compression gain of 36GHz is about 14dBm. The chip area is 2.4mm ×1mm.