In order to simplify the structure of the cold end of the pulse tube refrigerator (PTR) and have a better utilization of the cold energy of the system, a one-stage four-valve pulse tube refrigerator (FVPTR) with an &q...In order to simplify the structure of the cold end of the pulse tube refrigerator (PTR) and have a better utilization of the cold energy of the system, a one-stage four-valve pulse tube refrigerator (FVPTR) with an "L" type pulse tube structure and two orifice valves at the hot end of pulse tube has been constructed. Verification experiments show that the two orifice valve structure performs better than one orifice valve structure. A lowest temperature of 67.5 K was obtained at a frequency of 2.5 Hz under a system average pressure of 1.5 MPa with 200 mesh bronze screens as regenerator material, 80 mesh copper screens as stuffing material of heat exchanger. Due to the difficulty in manufacturing the thin "L" type pulse tube, the wall thickness of the pulse tube in the experiment was relatively difficult for us to reach 0.5 mm as that of the ordinary pulse tube, which resulted in relatively big system loss and affected the minimum temperature of the system to some degree.展开更多
The real gas effect is dominant at high pressure and low temperature, and it is modeled by complex equations of state other than perfect gas law. In the vicinity of liquid-vapor critical point, the real gas exhibits u...The real gas effect is dominant at high pressure and low temperature, and it is modeled by complex equations of state other than perfect gas law. In the vicinity of liquid-vapor critical point, the real gas exhibits unusual gas dynamic behavior. In the present work, a transient wave fields in unilateral opening pulse tube is simulated by solving the Navier-Stokes equations incorporated with the Peng-Robinson thermodynamic model. The computational fluid dynamics (CFD) results show a remarkable deviation between perfect gas model and real gas model for contact interface and shockwave. The wave diagram based on the real gas model can help to solve the problem of offset design point.展开更多
A dynamic experimental apparatus to measure the instantaneous velocity and pressure in the multi-bypass pulse tube refrigerator (MPTR) was designed and constructed. Some theortant experimental results of the instantan...A dynamic experimental apparatus to measure the instantaneous velocity and pressure in the multi-bypass pulse tube refrigerator (MPTR) was designed and constructed. Some theortant experimental results of the instantaneous measurements of the velocity and the pressure in the MPTR with two-bypass tubes during actual operation are presented. The effects of the middle-bypass version on the dynamic pressure and mass flow rate at the cold end of the pulse tube are evaluated from experimental measurements.DC-flow phenomena are observed in this MPTR. The reasons of the multi-bypass version improved the performance of pulse tube refrigerator are given.展开更多
Stirling-type pulse tube refrigerators have at-tracted academic and commercial interest in recent years due to their more compact configuration and higher effi-ciency than those of G-M type pulse tube refrigerators. I...Stirling-type pulse tube refrigerators have at-tracted academic and commercial interest in recent years due to their more compact configuration and higher effi-ciency than those of G-M type pulse tube refrigerators. In order to achieve a no-load cooling temperature below 20 K, a thermally coupled two-stage Stirling-type pulse tube refrig-erator has been built. The thermally coupled arrangement was expected to minimize the interference between the two stages and to simplify the adjustment and optimization of the phase shifters. A no-load cooling temperature of 14.97 K has been realized with the two-stage cooler driven by one linear compressor of 200 W electric input. When the two stages are driven by two compressors respectively, with total electric input of 400 W, the prototype has attained a no-load cooling temperature of 12.96 K, which is the lowest temperature ever reported with two-stage Stirling-type pulse tube refrigera-tors.展开更多
The pulse tube refrigerator (PTR) is a promising small-scale cryocooler. This paper first briefly introduces the history of the pulse tube refrigerator. It has pointed out that technology improvements and theoretica...The pulse tube refrigerator (PTR) is a promising small-scale cryocooler. This paper first briefly introduces the history of the pulse tube refrigerator. It has pointed out that technology improvements and theoretical developments of the pulse tube refrig- erator closely relate with the internal streaming effects. Then the discovering history and classification of the streaming or DC (direct current) flow effect are summarized. It proposes for the first time that the physical significance of the streaming con- tains the driving mechanisms and the transport mechanisms. It demonstrates that the driving mechanisms are the asymmetry of fluid flow and temperature while the transport mechanisms are a loop or vorticity, which transmits nonlinear dissipations. The important advancements have been made over the past two decades all over the world in research of streaming of the pulse tube refrigerator including Gedeon DC flow, Rayleigb streaming, the third type of DC flow and the regenerator circulation. With regard to Gedeon DC flow, theoretical and experimental analyses have been made and different suppression methods are summarized. In the aspect of Rayleigh streaming, it mainly focuses on the analytical solution of the second-order mass flow and the research of tapered pulse tubes. In particular, limited research on the third type of DC flow and regenerator circulation is presented. The experimental measurement techniques of streaming also are summarized. Finally, this paper briefly discusses the key scientific and technical issues of the current research, and foretells the future development trends of streaming research in PTR.展开更多
A two-stage gas-coupled Stirling/pulse tube refrigerator(SPR),whose first and second stages respectively involve Stirling and pulse tube refrigeration cycles,is a very promising spaceborne refrigerator.The SPR has man...A two-stage gas-coupled Stirling/pulse tube refrigerator(SPR),whose first and second stages respectively involve Stirling and pulse tube refrigeration cycles,is a very promising spaceborne refrigerator.The SPR has many advantages,such as a compact structure,high reliability,and high performance,and is expected to become an essential refrigerator for space applications.In research regarding gas-coupled regenerative refrigerator,the energy flow distribution between the two stages,and optimal phase difference between the pressure wave and volume flow,are two critical parameters that could widely influence refrigerator performance.The effects of displacer displacement on the pressure wave,phase difference,acoustic power distribution,and inter-stage cooling capacity shift of the SPR have been investigated experimentally.Notably,to obtain the maximum first-stage cooling capacity,an inflection point in displacement exists.When the displacer displacement is larger than the inflection point,the cooling capacity could be distributed between the first and second stages.In the present study,an SPR was designed and manufactured to work between the liquid hydrogen and liquid oxygen temperatures,which can be used to cool small-scale zero boil-off systems and space detectors.Under appropriate displacer displacement,the SPR can reach a no-load cooling temperature of 15.4 K and obtain 2.6 W cooling capacity at 70 K plus 0.1 W cooling capacity at 20 K with 160 W compressor input electric power.展开更多
The computation with the theory of modified Brayton Cycle indicates that higher cooling power and coefficient of performance for a pulse tube refrigerator can be achieved with He-H2 mixture as working gas than those w...The computation with the theory of modified Brayton Cycle indicates that higher cooling power and coefficient of performance for a pulse tube refrigerator can be achieved with He-H2 mixture as working gas than those with pure He in the temperature region of 30 K. In addition, it is found that Er3Ni, a regenerative material, is able to absorb H2 and produces Er3NiHx. The computation presents that the regenerative performance of Er3NiHx is better than that of Er3Ni due to its higher volume specific heat. Experimental results show that the pulse tube refrigeration performance in 30 K temperature region is enhanced greatly with He-H2 mixture and Er3NiHx packing.展开更多
Thermoacoustically driven pulse tube refrigerator, a novel cryocooler without any moving components using heat energy as driving power, attracts much effortsfrom the researchers in the field of cryogenics and refriger...Thermoacoustically driven pulse tube refrigerator, a novel cryocooler without any moving components using heat energy as driving power, attracts much effortsfrom the researchers in the field of cryogenics and refrigeration in the past decades. After a short introduction of the history about thermoacoustics, we presented the key technology, followed by a detailed review on theoretical and experimental developments and advances of thermoacoustics.The prospective research emphases are also presented at the end of this review.展开更多
We designed and constructed a dynamic experimental apparatus to measure the instantaneous velocity and pressure in the multi-bypass pulse tube refrigerator with two-bypass tube. DC-flow phenomena are observed from exp...We designed and constructed a dynamic experimental apparatus to measure the instantaneous velocity and pressure in the multi-bypass pulse tube refrigerator with two-bypass tube. DC-flow phenomena are observed from experimental results. The reasons of multibypass version improved the performance of pulse tube refrigerator were given.展开更多
文摘In order to simplify the structure of the cold end of the pulse tube refrigerator (PTR) and have a better utilization of the cold energy of the system, a one-stage four-valve pulse tube refrigerator (FVPTR) with an "L" type pulse tube structure and two orifice valves at the hot end of pulse tube has been constructed. Verification experiments show that the two orifice valve structure performs better than one orifice valve structure. A lowest temperature of 67.5 K was obtained at a frequency of 2.5 Hz under a system average pressure of 1.5 MPa with 200 mesh bronze screens as regenerator material, 80 mesh copper screens as stuffing material of heat exchanger. Due to the difficulty in manufacturing the thin "L" type pulse tube, the wall thickness of the pulse tube in the experiment was relatively difficult for us to reach 0.5 mm as that of the ordinary pulse tube, which resulted in relatively big system loss and affected the minimum temperature of the system to some degree.
文摘The real gas effect is dominant at high pressure and low temperature, and it is modeled by complex equations of state other than perfect gas law. In the vicinity of liquid-vapor critical point, the real gas exhibits unusual gas dynamic behavior. In the present work, a transient wave fields in unilateral opening pulse tube is simulated by solving the Navier-Stokes equations incorporated with the Peng-Robinson thermodynamic model. The computational fluid dynamics (CFD) results show a remarkable deviation between perfect gas model and real gas model for contact interface and shockwave. The wave diagram based on the real gas model can help to solve the problem of offset design point.
文摘A dynamic experimental apparatus to measure the instantaneous velocity and pressure in the multi-bypass pulse tube refrigerator (MPTR) was designed and constructed. Some theortant experimental results of the instantaneous measurements of the velocity and the pressure in the MPTR with two-bypass tubes during actual operation are presented. The effects of the middle-bypass version on the dynamic pressure and mass flow rate at the cold end of the pulse tube are evaluated from experimental measurements.DC-flow phenomena are observed in this MPTR. The reasons of the multi-bypass version improved the performance of pulse tube refrigerator are given.
基金This work was supported by the National Natural Science Foundation of China(Grant No.50376055)DAAD of Germany.
文摘Stirling-type pulse tube refrigerators have at-tracted academic and commercial interest in recent years due to their more compact configuration and higher effi-ciency than those of G-M type pulse tube refrigerators. In order to achieve a no-load cooling temperature below 20 K, a thermally coupled two-stage Stirling-type pulse tube refrig-erator has been built. The thermally coupled arrangement was expected to minimize the interference between the two stages and to simplify the adjustment and optimization of the phase shifters. A no-load cooling temperature of 14.97 K has been realized with the two-stage cooler driven by one linear compressor of 200 W electric input. When the two stages are driven by two compressors respectively, with total electric input of 400 W, the prototype has attained a no-load cooling temperature of 12.96 K, which is the lowest temperature ever reported with two-stage Stirling-type pulse tube refrigera-tors.
基金supported by the National Natural Science Foundation of China(Grant No.51176198)
文摘The pulse tube refrigerator (PTR) is a promising small-scale cryocooler. This paper first briefly introduces the history of the pulse tube refrigerator. It has pointed out that technology improvements and theoretical developments of the pulse tube refrig- erator closely relate with the internal streaming effects. Then the discovering history and classification of the streaming or DC (direct current) flow effect are summarized. It proposes for the first time that the physical significance of the streaming con- tains the driving mechanisms and the transport mechanisms. It demonstrates that the driving mechanisms are the asymmetry of fluid flow and temperature while the transport mechanisms are a loop or vorticity, which transmits nonlinear dissipations. The important advancements have been made over the past two decades all over the world in research of streaming of the pulse tube refrigerator including Gedeon DC flow, Rayleigb streaming, the third type of DC flow and the regenerator circulation. With regard to Gedeon DC flow, theoretical and experimental analyses have been made and different suppression methods are summarized. In the aspect of Rayleigh streaming, it mainly focuses on the analytical solution of the second-order mass flow and the research of tapered pulse tubes. In particular, limited research on the third type of DC flow and regenerator circulation is presented. The experimental measurement techniques of streaming also are summarized. Finally, this paper briefly discusses the key scientific and technical issues of the current research, and foretells the future development trends of streaming research in PTR.
基金supported by the Hundred Talents Program of the Chinese Academy of Sciences,the National Natural Science Foundation of China(Grant No.51806231)the Strategic Priority Research Program of the Chinese Academy of Sciences(XDB35000000,XDB35040102)。
文摘A two-stage gas-coupled Stirling/pulse tube refrigerator(SPR),whose first and second stages respectively involve Stirling and pulse tube refrigeration cycles,is a very promising spaceborne refrigerator.The SPR has many advantages,such as a compact structure,high reliability,and high performance,and is expected to become an essential refrigerator for space applications.In research regarding gas-coupled regenerative refrigerator,the energy flow distribution between the two stages,and optimal phase difference between the pressure wave and volume flow,are two critical parameters that could widely influence refrigerator performance.The effects of displacer displacement on the pressure wave,phase difference,acoustic power distribution,and inter-stage cooling capacity shift of the SPR have been investigated experimentally.Notably,to obtain the maximum first-stage cooling capacity,an inflection point in displacement exists.When the displacer displacement is larger than the inflection point,the cooling capacity could be distributed between the first and second stages.In the present study,an SPR was designed and manufactured to work between the liquid hydrogen and liquid oxygen temperatures,which can be used to cool small-scale zero boil-off systems and space detectors.Under appropriate displacer displacement,the SPR can reach a no-load cooling temperature of 15.4 K and obtain 2.6 W cooling capacity at 70 K plus 0.1 W cooling capacity at 20 K with 160 W compressor input electric power.
文摘The computation with the theory of modified Brayton Cycle indicates that higher cooling power and coefficient of performance for a pulse tube refrigerator can be achieved with He-H2 mixture as working gas than those with pure He in the temperature region of 30 K. In addition, it is found that Er3Ni, a regenerative material, is able to absorb H2 and produces Er3NiHx. The computation presents that the regenerative performance of Er3NiHx is better than that of Er3Ni due to its higher volume specific heat. Experimental results show that the pulse tube refrigeration performance in 30 K temperature region is enhanced greatly with He-H2 mixture and Er3NiHx packing.
文摘Thermoacoustically driven pulse tube refrigerator, a novel cryocooler without any moving components using heat energy as driving power, attracts much effortsfrom the researchers in the field of cryogenics and refrigeration in the past decades. After a short introduction of the history about thermoacoustics, we presented the key technology, followed by a detailed review on theoretical and experimental developments and advances of thermoacoustics.The prospective research emphases are also presented at the end of this review.
文摘We designed and constructed a dynamic experimental apparatus to measure the instantaneous velocity and pressure in the multi-bypass pulse tube refrigerator with two-bypass tube. DC-flow phenomena are observed from experimental results. The reasons of multibypass version improved the performance of pulse tube refrigerator were given.