In this paper, a co-polarized, co-located electric and magnetic dipoles(CCEMD) with high isolation is presented. The antenna consists of a loop based on segmented line and two independent feeding ports. Two modes of t...In this paper, a co-polarized, co-located electric and magnetic dipoles(CCEMD) with high isolation is presented. The antenna consists of a loop based on segmented line and two independent feeding ports. Two modes of the antenna are exited separately, the first one has a radiation pattern equivalent to an electric dipole by exciting anti-phase current with symmetric distribution, and the second one is like a magnetic dipole by exciting uniform and in-phase currents along the loop. The antenna is fabricated and tested. Its measured common-10 d B impedance bandwidth at two ports is 280 MHz(2.32-2.6 GHz) with isolation better than 41 d B. Its MIMO performance in terms of capacity gain(CG) over the SISO system is investigated in a multipath rich environment containing two parallel PEC planes by both measurements and image theory based simulations. Results show that, in free space, the CG results are just slightly larger than 1, however, in the multipath rich channel, the CG values are very close to 2, which indicates that two separate subchannels can be achieved by the proposed CCEMD. The measured results of CG agree well with that obtained by simulation.展开更多
采用HRGC/HRMS和同位素稀释定量技术对样品中17种4~8个氯原子取代的二嗯英和呋喃(PCDDs/Fs)与12种共平面多氯联苯(PCBs)定量分析。样品经索式抽提、FMS Power Prep系统净化、浓缩,利用高分辨气相色谱/高分辨质谱联用仪的多离子检...采用HRGC/HRMS和同位素稀释定量技术对样品中17种4~8个氯原子取代的二嗯英和呋喃(PCDDs/Fs)与12种共平面多氯联苯(PCBs)定量分析。样品经索式抽提、FMS Power Prep系统净化、浓缩,利用高分辨气相色谱/高分辨质谱联用仪的多离子检测方式,同位素稀释技术对样品中的目标化合物进行定性和定量。该方法的检出限为pg/g水平。^13同位素内标回收率范围为47%~100%。对3个CRM鱼样中17个PCDDs/Fs和4个PCBs的检测值均在标准定值允许误差范围内。对5个不同的实际样品鱼进行测定表明,样品的回收率在48%~100%之间,回收率的相对标准偏差小于20%;对同一样品进行定量检测的精密度测试结果表明,17种PCDDs/Fs浓度的RSD低于16%,12种PCBs浓度的RSD低于11%。本方法定量分析重现性良好。展开更多
基金supported by the National Natural Science Foundations of China (61771435)
文摘In this paper, a co-polarized, co-located electric and magnetic dipoles(CCEMD) with high isolation is presented. The antenna consists of a loop based on segmented line and two independent feeding ports. Two modes of the antenna are exited separately, the first one has a radiation pattern equivalent to an electric dipole by exciting anti-phase current with symmetric distribution, and the second one is like a magnetic dipole by exciting uniform and in-phase currents along the loop. The antenna is fabricated and tested. Its measured common-10 d B impedance bandwidth at two ports is 280 MHz(2.32-2.6 GHz) with isolation better than 41 d B. Its MIMO performance in terms of capacity gain(CG) over the SISO system is investigated in a multipath rich environment containing two parallel PEC planes by both measurements and image theory based simulations. Results show that, in free space, the CG results are just slightly larger than 1, however, in the multipath rich channel, the CG values are very close to 2, which indicates that two separate subchannels can be achieved by the proposed CCEMD. The measured results of CG agree well with that obtained by simulation.
文摘采用HRGC/HRMS和同位素稀释定量技术对样品中17种4~8个氯原子取代的二嗯英和呋喃(PCDDs/Fs)与12种共平面多氯联苯(PCBs)定量分析。样品经索式抽提、FMS Power Prep系统净化、浓缩,利用高分辨气相色谱/高分辨质谱联用仪的多离子检测方式,同位素稀释技术对样品中的目标化合物进行定性和定量。该方法的检出限为pg/g水平。^13同位素内标回收率范围为47%~100%。对3个CRM鱼样中17个PCDDs/Fs和4个PCBs的检测值均在标准定值允许误差范围内。对5个不同的实际样品鱼进行测定表明,样品的回收率在48%~100%之间,回收率的相对标准偏差小于20%;对同一样品进行定量检测的精密度测试结果表明,17种PCDDs/Fs浓度的RSD低于16%,12种PCBs浓度的RSD低于11%。本方法定量分析重现性良好。