A novel electromagnetic induction detector with two inductors for CE was described here.The two inductors were used as signal detection and reference,respectively.The parameters affecting the detector performance(inc...A novel electromagnetic induction detector with two inductors for CE was described here.The two inductors were used as signal detection and reference,respectively.The parameters affecting the detector performance(including coil turns,detection distance, excitation frequency,voltage,etc.) were optimized.Under the optimum condition,the feasibility of the detector was examined by analyzing inorganic ions.The fabricated detector showed good linear relationship between the response and the analytes concentrations,with a detection limit of 13μmol/L for Na~+(S/N = 3).A variety of advantages,such as simple construction, ease of operation,and considerably universal response,suggested this novel detector a promising application prospect in analytical area.展开更多
Fiber strain sensors with robust sensing performance are indispensable for human-machine interactions in the electronic textiles.However,current fiber strain sensors are confronted with the challenges of unavoidable d...Fiber strain sensors with robust sensing performance are indispensable for human-machine interactions in the electronic textiles.However,current fiber strain sensors are confronted with the challenges of unavoidable deterioration of functional sensing components during wearable and extreme environments,resulting in unsatisfactory stability and durability.Here,we present a robust fiber strain sensor based on the mutual inductance effect.The sensor is assembled by designing coaxial helical coils around an elastic polyurethane fiber.When stretching the fiber sensor,the strain is detected by recording the voltage changes in the helical coils due to the variation in magnetic flux.The resultant fiber strain sensor shows high linearity(with a linear regression coefficient of 0.99)at a large strain of 100%,and can withstand various extreme environmental conditions,such as high/low temperatures(from-30℃to 160℃),and severe deformations,such as twisting and pressing(with a pressure of 500 N/cm).The long-term cyclic stability of our fiber strain sensor(100,000 cycles at a strain of 100%)is superior to that of most reported flexible resistive and capacitive strain sensors.Finally,the mass-produced fiber strain sensors are woven into a smart textile system to accurately capture gestures.展开更多
A calibrating device for the Rogowski coil is developed, which can be used to calibrate the Rogowski coil having a partial response time within tens of nanoseconds. Its key component is a step current generator, which...A calibrating device for the Rogowski coil is developed, which can be used to calibrate the Rogowski coil having a partial response time within tens of nanoseconds. Its key component is a step current generator, which can generate the output with a rise time of less than 2 ns and a duration of larger than 300 ns. The step current generator is composed by a pulse forming line (PFL) and a pulse transmission line (PTL). A TEM (transverse electromagnetic mode) coaxial measurement unit is used as PTL, and the coil to be calibrated and the referenced standard Rogowski coil can be fixed in the unit. The effect of the dimensions of the TEM unit is discussed theoretically as well as experimentally.展开更多
基金support from the National Natural Science Foundation of China(Nos20727006 and 21075139)
文摘A novel electromagnetic induction detector with two inductors for CE was described here.The two inductors were used as signal detection and reference,respectively.The parameters affecting the detector performance(including coil turns,detection distance, excitation frequency,voltage,etc.) were optimized.Under the optimum condition,the feasibility of the detector was examined by analyzing inorganic ions.The fabricated detector showed good linear relationship between the response and the analytes concentrations,with a detection limit of 13μmol/L for Na~+(S/N = 3).A variety of advantages,such as simple construction, ease of operation,and considerably universal response,suggested this novel detector a promising application prospect in analytical area.
基金financially by Ministry of Science and Technology of the People's Republic of China(2022YFA1203001,2022YFA1203002)National Natural Science Foundation of China(T2321003,22335003,T2222005,22175042)Science and Technology Commission of Shanghai Municipality(21511104900).
文摘Fiber strain sensors with robust sensing performance are indispensable for human-machine interactions in the electronic textiles.However,current fiber strain sensors are confronted with the challenges of unavoidable deterioration of functional sensing components during wearable and extreme environments,resulting in unsatisfactory stability and durability.Here,we present a robust fiber strain sensor based on the mutual inductance effect.The sensor is assembled by designing coaxial helical coils around an elastic polyurethane fiber.When stretching the fiber sensor,the strain is detected by recording the voltage changes in the helical coils due to the variation in magnetic flux.The resultant fiber strain sensor shows high linearity(with a linear regression coefficient of 0.99)at a large strain of 100%,and can withstand various extreme environmental conditions,such as high/low temperatures(from-30℃to 160℃),and severe deformations,such as twisting and pressing(with a pressure of 500 N/cm).The long-term cyclic stability of our fiber strain sensor(100,000 cycles at a strain of 100%)is superior to that of most reported flexible resistive and capacitive strain sensors.Finally,the mass-produced fiber strain sensors are woven into a smart textile system to accurately capture gestures.
文摘A calibrating device for the Rogowski coil is developed, which can be used to calibrate the Rogowski coil having a partial response time within tens of nanoseconds. Its key component is a step current generator, which can generate the output with a rise time of less than 2 ns and a duration of larger than 300 ns. The step current generator is composed by a pulse forming line (PFL) and a pulse transmission line (PTL). A TEM (transverse electromagnetic mode) coaxial measurement unit is used as PTL, and the coil to be calibrated and the referenced standard Rogowski coil can be fixed in the unit. The effect of the dimensions of the TEM unit is discussed theoretically as well as experimentally.